• Title/Summary/Keyword: 수평관

Search Result 295, Processing Time 0.024 seconds

A Study on Standards for Pressure Relief Valve Vent Pipes from LPG Storage Tanks (LPG용 압력방출밸브 방출관 설치기준 개선방안)

  • Lee, Jin-Han;Eom, Suk-Hwa;Kim, Lae-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.59-64
    • /
    • 2012
  • The dispersion of gas discharged from the vent pipes of pressure relief valves attached LPG (Liquefied Petroleum Gas) storage tank was studied. In general, vent pipes should be positioned so that they discharge vertically upwards in a safe place, and installed so that, in the event of ignition of discharged gas, flame impingement on any vessel, equipment or piping is avoided[1][2]. In Korea, on the other hand, there are various type of the end of vent pipes because there is no rule for discharge directions from the vent pipes. In this paper, we took 4 types of vent directions from the pipes in to account, such as vertically upward, vertically downward, vertically 4-way and horizontally 2-way direction. A software package, FLACS, was adopted to simulate gas dispersion from the vent pipes. We found that vertically downward, vertically 4-way and horizontally 2-way discharge from vent pipes were undesirable to avoid ignition on near ground. Therefore, it was obvious that vertically upward opening of a vent pipe is the best option to discharge in a safe place.

Inchworm-Like Robotic Colonoscope UsingLegs for Clamping (다리를 이용한 클램핑 방식의 자벌레 이동방식 대장내시경로봇)

  • Park, Hyun-Jun;Leem, Sang-Hyuck;Kim, Byung-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.789-795
    • /
    • 2010
  • For the reliable clamping of a robotic colonoscope inside the colon, we propose a clamping module consisting of six legs at the front and a trigger at the rear. In addition, a pneumatic-line based locomotive mechanism, which was developed previously for in-pipe inspection, is adopted to reduce the friction force between the pneumatic lines and the locomotion environment. In order to evaluate locomotion performance, a robot with a diameter of 15 mm and a length of 110.250 mm is used. Based on control signal from LabVIEW, it is tested in acrylic pipe and pig's colon. The proposed robot is able to move in the curved path which has a radius of over 25 mm. The speed of the robot is 33 mm/s in a straight path and 12.1 mm/s on a vertical path. The proposed robot, which has one pneumatic line and two clamping modules, conclusively shows reliable locomotion performance under in vitro condition.

Assessment and Improvement of the Horizontal In-Tube Condensation Heat Transfer Model in the MARS code (MARS 코드의 수평관내부 응축열전달 모델 평가 및 개선)

  • Lee, Hyun Jin;Ahn, Tae Hwan;Yun, Byong Jo;Jeong, Jae Jun
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.56-68
    • /
    • 2016
  • Extensive researches have been carried out for enhancing the safety of nuclear power plants and, especially, the development of passive cooling systems, such as passive containment cooling system (PCCS) and passive residual heat removal system, is increasingly important, where condensation is a crucial heat transfer mechanism. Recently, Ahn & Yun et al. developed a horizontal in-tube condensation heat transfer model as one of the activities for the PCCS development. In this work, we implemented the Ahn & Yun 's condensation heat transfer model into the MARS code and assessed it using the PASCAL experimental data. Based on the results of the assessment, we identified the limitations of the Ahn & Yun 's model and suggested a modified Ahn & Yun 's model, and assessed the model using various experimental data.

A Study on the Anisotropic Characteristics of Permeability of a Remolded Decomposed Mudstone Soil in Pohang (재성형된 포항 이암풍화토의 투수에 관한 이방성 연구)

  • Kim, Young-Su;Jung, Sung-Gwan;Kim, Dae-Man;Kwon, Yong-Min
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.3
    • /
    • pp.5-17
    • /
    • 2003
  • Using Rowe cell for vertical and lateral consolidate test, we concerned characteristics of vertical and lateral consolidation, and permeability on the remolded Decompoed Mudstone Soil in Phoang, and then, compared it with Oedometer test results. Indirect coefficients of permeability were calculated by the results of the coefficient of consolidation that were derived from 9 different kinds of methods. The values of indirect coefficients of permeability derived from ${\sqrt{t}}$ method and hyperbolic method were similar to the results of direct coefficients of permeability with respect to vertical drainage, but, in the case of lateral drainage, for all kinds of methods, the values of indirect coefficients of permeability showed overestimated ones. With vertical and lateral direct coefficient of permeability, by investigating the anisotropic effect with respect to permeability on Decomposed mudstone soil, we obtained average value, 13, with respect to anisotropic characteristics for all kinds of consolidation loadings.

  • PDF

Evaporation kent transfer characteristics of R-290 and R-600a in the horizontal tubes (수평관내 R-290과 R-600a의 증발 열전달 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.264-269
    • /
    • 2008
  • This paper presents the experimental results of evaporation heat transfer coefficients of HC(e.g. R290 and R600a), R-22 as a HCFCs refrigerant in horizontal double pipe heat exchangers, having four different inner diameters of 10.07 mm and 6.54 mm respectively. The experiments of the evaporation process were conducted at mass flux of $35.5{\sim}210.4\;kg/m^2s$ and cooling capacity of $0.95{\sim}10.1\;kW$. The main results were summarized as follows : The average evaporation heat transfer coefficient of R-290 and R-600a was higher value than that of R-22. In comparison with R-22, the evaporation heat transfer coefficient of R-290 and 600a is approximately $56.7{\sim}70.1$ and $46.6{\sim}59.7%$ higher, respectively. In comparison with experimental data and some correlations, the evaporation heat transfer coefficients are well matched with the Kandlikar's correlation regardless of a type of refrigerants and tube diameters.

A Study on Characteristic of Underground Corrugated Steel Structure (파형강 지중구조물의 제특성 연구)

  • Park, Yeon Soo;Seo, Byoung Chal;Kim, Byong Ha;Park, Sun Joon
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.6
    • /
    • pp.693-702
    • /
    • 2001
  • Ductility pipes, like corrugated steel structures, are expected to reduce its deformation when they are arranged in a row. Verifying this assumption can help make economic designs possible. Though checking the deformation of ductility pipe structures, like corrugated steel structure, decreasing deformation was found when the pipes are arranged in a row. In this way, arranging a corrugated steel structures in a row shows decreased deformation compared to corrugated steel pipes arranged in a single structure because the bedding effect restrains deformation. The deformation rates of reduction are proportionate to the diameter of the corrugated steel structure.

  • PDF

Deformation Characteristics of Underground Pipe with In-situ Soil CLSM (현장발생토 CLSM을 이용한 지하매설관의 변형특성)

  • 박재헌;이관호;조재윤;김석남
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.3
    • /
    • pp.129-139
    • /
    • 2004
  • During the construction of circular underground pipe, the non-proper compaction along the pipe and the decrease of compaction efficiency have been the main problems to induce the failure of underground pipe or facility. The use of CLSM (controlled low strength materials) should be one of the possible applications to overcome those problems. In this research, the small-scaled model test and the numeric analysis using PENTAGON-3D FEM program were carried out for three different cases on the change of backfill materials, including the common sand, the soil from construction site, and the CLSM.. From the model test in the lab, it was found out that the use of CLSM as backfill materials reduced the vertical and lateral deformation of the pipe, as well as the deformation of the gound surface. The main reason for reducing the deformation would be the characteristics of the CLSM, especially self-leveling and self-hardening properties. The measured earth pressure at the surround of the corrugated pipe using the CLSM backfills was smaller than those in the other cases, and the absolute value was almost zero. Judging from the small-scaled model test and FEM analysis, the use of CLSM as backfill materials should be one of the best choices reducing failure of the underground pipes.

Transverse and Diagonal Mode Structures of Three-dimensional Detonation Wave (3차원 데토네이션 파의 수평 및 대각선 모드 파면 구조)

  • Cho Deok-Rae;Choi Jeong-Yeol
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.343-346
    • /
    • 2005
  • Three dimensional structures of detonation wave propagating through a square-shaped duct were investigated using computational method and parallel processing. Inviscid fluid dynamics equations coupled with $variable-{\gamma}$ formulation and simplified one-step Arrhenius chemical reaction model were analysed by MUSCL-type TVD scheme and four stage Runge-Kutta time integration. The unsteady computational results in three dimension show the detailed mechanism of transverse mode and diagonal mode of detonation wave instabilities resulting same cell length but different cell width in smoked-foil record.

  • PDF

The characteristics of heat transfer coefficient for falling-film evaporation on a horizontal tube with aqueous LiBr solution (LiBr 수용액의 수평관 유하액막 증발에 있어서의 열전달계수 특성)

  • Ji, Yong-Hae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.2
    • /
    • pp.294-302
    • /
    • 1997
  • Falling-film evaporation experiments for aqueous solution of lithium bromide (LiBr) were performed on a horizontal smooth 19.05-mm-dia copper tube. Average heat transfer coefficients were obtained with varied film Reynolds numbers, system pressures, LiBr concentrations and degrees of wall superheat. Heat transfer coefficients increase with increasing system pressure and decreasing concentration. For degrees of wall superheat, the heat transfer coefficient did not't show the distinct trend. For this experimental ranges, heat transfer coefficients showed maximum values at an optimal film Reynolds number. The results of this work were compared with pool boiling data reported previously, and it was shown that the heat transfer performance is superior to the pool boiling.

Characteristics of heat transfer and bubble around horizontal tube in a fluidized bed heat exchanger (유동층 열교환기의 수평관에서 열전달 및 기포특성)

  • 김성원;안정렬;김상돈
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2000.11a
    • /
    • pp.97-100
    • /
    • 2000
  • 유동층 열교환기 (Fluidized Bed Heat Exchanger; FBHE) 는 온도 균일성이라는 유동층의 특징을 이용하여 적당한 전열면적을 갖는 열교환관을 층 내 설치하여 일정한 양의 열을 전열시키는 것으로, 최근 순환유동층 연소로의 scale-up 을 통한 열용량 증대와 함께 고온의 재순환물질로부터 열을 회수, 연소로의 온도제어 및 열회수율의 극대화를 얻고자 재순환부에 연결하여 사용하고 있다. 또한, 가압순환유동층의 개발과 더불어 유효열전달 면적의 증대를 통한 상대적인 연소로 소형화를 위해 채택되고 있다. 특히, 유동층 열교환기는 전체 공정에서 20-60% 의 열을 회수할 수 있어, 열전달에 있어 매우 중요한 역할을 차지한다.(중략)

  • PDF