• Title/Summary/Keyword: 수평관

Search Result 295, Processing Time 0.023 seconds

Effect of Horizontal Pitch-to-Diameter Ratio on the Natural-Convection Heat Transfer of Two Staggered Cylinders (엇갈리게 배열된 두 개의 수평관에서 수평 피치-직경비에 따른 자연대류 열전달 영향)

  • Chae, Myeong-Seon;Heo, Jeong-Hwan;Chung, Bum-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.259-268
    • /
    • 2012
  • This study measured the natural-convection heat transfer of two vertically staggered cylinders with varying vertical pitch-to-diameter ($P_v$/D) and horizontal pitch-to-diameter ($P_h$/D) ratios. The measured heat-transfer rates for the lower cylinder agreed well with the existing heat-transfer correlations for a single cylinder. At the smallest $P_v$/D, the rising plume from the lower cylinder provides the upper cylinder with a preheated flow, and the heat-transfer rates of the upper cylinder decrease, but increase very sensitively with $P_h$/D. However, at the largest $P_v$/D, the velocity effect dominates, and the heat-transfer rates of the upper cylinder are larger than that of a single cylinder, and decrease less sensitively with $P_h$/D. Even if $P_h$/D is increased, the heat-transfer rate of the upper cylinder is higher than that of the lower cylinder because of the chimney and side flow effects. This work expanded the flow ranges to turbulent flows. The cupric acid-copper sulfate ($H_2SO_4-CuSO_4$) electroplating system was adopted for the measurements of the mass-transfer rates instead of the heat-transfer experiments based on the analogy concept. The measurements were made by varying $P_v$/D (1.02-5) and $P_h$/D (0-2) in both laminar and turbulent flows. The Rayleigh number ranged from $1.5{\times}10^8$ to $2.5{\times}10^{10}$, and the Prandtl number was 2,014.

The Effect of Pitch-to-Diameter Ratio on Natural Convection Heat Transfer of Two In-Line Horizontal Cylinders (나란히 수직으로 배열된 두 개의 수평관에서 피치-직경비에 따른 자연대류 열전달 영향)

  • Chae, Myeong-Seon;Kang, Gyeong-Uk;Chung, Bum-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.417-424
    • /
    • 2011
  • Natural convection heat transfer experiments from two parallel horizontal cylinders were performed varying the Pitch-to-Diameter ratio (P/D) of 1.02-9 at Sc of 2,014 to 8,334 and $Ra_D$ of $1.5{\times}10^8$ to $4.5{\times}10^{10}$. Mass transfer experiments that are analogous to the heat transfer experiments were performed using copper electroplating system. In all cases, the measured heat transfer rates for the lower cylinder agreed well with the existing heat transfer correlations developed from a single cylinder. For laminar flows, the measured heat transfer rates of the upper cylinder were less than those of the lower cylinder at P/D less than about 1.5. However, as the P/D increased, the heat transfer rates of the upper cylinder increased. For turbulent flows, the heat transfer rates of the upper cylinder were considerably similar to those of the lower cylinder when the P/D is approximately unity. In contrast, as the P/D increased, the heat transfer rates of the upper cylinder were always higher than those of the lower cylinder.

A Study on the Distribution of Hydraulic Head Along the Lateral in a Pilot-Scale Riverbank Filtration (강변여과에서 파일럿규모 수평집수관의 수두분포 연구)

  • Jeong, Jae-Min;Park, Jae-Young;Lee, Jong-Jin;Kim, Yong-Woon;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.334-339
    • /
    • 2013
  • A pilot-scale sand-box experiment simulating a lateral of collector well used in riverbank filtration was performed, and hydraulic head distributions along the lateral were measured according to the various drawdowns at the well. The results of this experiment were compared to the predicted values obtained using a theory previously developed by Kim in order for its validation. This theory predicts the head loss in a large-scale lateral given the loss in a small-scale one, and to have actual values for comparison, the results from a lab-scale experiment previously performed by Kim were employed. Comparing the experimental values to the extrapolated value indeed confirmed the validity of the theory. A procedure to determine the hydraulic head distribution of a practical-scale lateral was also presented applying the theory to the experimental result of this study in an effort to show the process of lateral design for riverbank filtration.

Infiltration Measurement and Prediction of Soil Water Flow Redistribution (침투율 측정과 재분배시의 토양수분흐름의 추정)

  • 정상옥
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.29 no.2
    • /
    • pp.74-81
    • /
    • 1987
  • 지표에서 토양속으로 흐르는 물의 침수를을 동심원관형침수계를 사용하여 측정하였다. 내부관과 외부관을 비교함으로서 침투율 측정시 침투계 바깥쪽으로 흐르는 수평방향으로 흐름을 예상할수 있으며 서로 다른 초기함수조건에서 침투율을 측정, 비교함으로써 초기함수 상태의 침투율에 대한 영향을 고찰하였다. 측정치를 분석한 결과 예상한 대로 바깥쪽으로 흐르는 수평방향의 토양수분으로 인하여 외부관에서의 침투율이 내부관에서 보다 평균90% 컸으며, 또 초기 함수량이 작은 경우가 큰 경우보다 침투율이 켰다. 침수가 끝난 후 재분배시의 토양 수분 흐름은 수리지표를 검사함으로써 추정하였다.수평 및 수직방향의 수리지표는 다단 텐시오미터(multiple-depth tensiometer)를 사용하여 토양속의 공극수압을 측정하여 계산하였다 수리지표를 검사한 결과 재분배시 수평방향의 토양수분 흐름은 일정한 방향이 아니라 경우에 따라서 원관 침투계의 중심쪽으로 또는 바깥쪽으로 흘렀다. 이느 토양의 물리적 성질이 장소에 따라서 균일하지 않았음에 기인한 것이라 판단된다. 재분배시 수평 및 수직방향의 평균수리지표의 비율을 검사한 결과 시간이 경과할수록 비율이 감소 되었으며 또 깊이가 깊어질수록 감소하였다.이는 즉 시간이 지날수록 깊이가 깊어질수록 토양수분 흐름의 수평방향 성분이 감소한다는 것을 나타낸다.

  • PDF

An Experimental Study on the Performance of Multi-Diameter Lateral for Riverbed Filtration (하상여과용 다직경 수평집수관의 효능에 대한 실험연구)

  • Bae, Gha-Ram;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.359-364
    • /
    • 2012
  • In order to prevent the decrease in well efficiencies due to friction in the axial flow in long, large-diameter laterals, a multi-diameter lateral was devised and tested through lab-scale sand-box experiments to assess its performance. In the experiment, three different production rates were applied over the multi-diameter and the three single-diameter laterals to obtain the hydraulic head distributions for each, which was used to assess the performance of the laterals. Results elucidated that the multi-diameter lateral reduced the material cost by more than a third, in comparison to the single-diameter lateral, while maintaining the production rate at higher than 93%, proving its superiority. Furthermore, results indicated that exit velocities exceeding 0.8 m/sec in horizontal wells tended to distort the hydraulic head distribution near the exit, providing evidence of its inefficiency.

A Study on the Monitoring Case of the Soil Blocking Facilities Due to Water Pipe Rupture Accident (상수관 파열 사고로 인한 흙막이 가시설 계측사례 연구)

  • Woo, Jong-Tae
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.244-246
    • /
    • 2023
  • 아파트 신축공사 흙막이 가시설 현장에 근접 매설된 상수관의 누수 및 파열 사고로 인접 건물이 공사현장 방향으로 58~188mm 기울어졌으며, 지중수평경사계 계측결과 21.07.20일 22.64mm가 21.10.18.일 101.46mm로 급격하게 78.82mm의 큰 수평 변위가 발생되었으며, 이로 인해 흙막이 가시설의 사보강재가 변형되고 토류판 일부가 파손되었다.

  • PDF

A Study on the Optimum Design of Horizontal Collectors in Floodplain Filtration (홍수터여과에서 집수관의 최적설계 연구)

  • Pi, Seong-Min;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.430-437
    • /
    • 2012
  • In order to obtain information on the design parameters of the horizontal laterals in floodplain filtration, laboratory-scale sand-box experiments were performed where the head distributions on the laterals and the groundwater profiles were measured according to the change in parameters including lateral diameter, hydraulic conductivity of the sand, water level at the well and raw-water supply rate. Measured data were analyzed using a numerical code in order to identify the discharge intensity distribution along the laterals. It was observed from the result that the lowering of the water level at the well had minimal adverse effect on the performance of the floodplain filtration. Results also elucidated that the low conveyance of the laterals to transmit the filtrate was compensated and supplemented by a natural augmentation in horizontal conveyance through the aquifer when the raw-water supply rate exceeded the adequate recovery rate. With this mechanism, the water quality is expected to improve further since the travel distance through the aquifer is amplified. Based on these findings it can be suggested that the diameter of the lateral used in the floodplain filtration may be smaller than those in riverbank/bed filtration. It was also found that the ratio between the head loss occurring in a lateral and the total head loss in the floodplain filtration was proportional to the exit velocities of the laterals, which may be used to design and/or evaluate the lateral in floodplain filtration.

Natural Convection Heat Transfer from a Horizontal Heat Exchanger Tube with a Fin (單一핀을 가진 水平管에서의 自然對流 熱傳達)

  • 정한식;권순석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.279-286
    • /
    • 1987
  • An numerical and experimental study has been performed on natural convection heat transfer from a horizontal heat exchanger tube with a fin. At s bare tube, by increasing $C_{T}$ (tube conduction parameter), mean Nusselt number and outer wall temperature are apparently increased at $C_{T}$.leq.300, slightly increased at $C_{T}$>300 and they can be represented in an exponential function of $C_{T}$. Natural convection heat transfer characteristics for the tube with a fin at given Rayleigh number are well agreed by those for an isothermal cylinder at a modified Rayleigh number. The local fin Nusselt number of the tube with a downward fin is much higher than that of the tube with an upward fin. The comparisons between numerical and experimental results showed good agreement.reement.

Visualization of Natural Convection Heat Transfer on Horizontal Cylinder Using the Copper Electroplating System (전기도금계를 이용한 수평관 외부 자연대류의 시각화)

  • Heo, Jeong-Hwan;Chung, Bum-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.1
    • /
    • pp.43-51
    • /
    • 2011
  • Natural convection heat transfer phenomena on a horizontal cylinder have been studied experimentally in order to investigate the applicability of analogy experimental methodology using a copper electroplating system and to visualize the local heat transfer rates depending on the angular position and the diameter of the horizontal cylinder. In the copper electroplating system, the copper ion produced at the anode moves by convection and diffusion to the cathode and reduces at the cathode, representing the heat transfer. By using aluminum cathode with a distinguishable color, the amount of copper plated could visualize the amount of heat transferred depending on the angular position of the cylinder. The diameter of the cylinder is varied from 0.01m to 0.15m, which correspond to Rayleigh numbers in the range of $1.73{\times}10^7$ to $5.69{\times}10^{11}$. The test results are in good agreement with existing heat transfer correlations.

Experimental Study on the Behavior of Two-phase Flow in Pipes Using Electrical Conductivity Meter (전기전도계를 이용한 관 내 이상류 거동에 대한 실험적 연구)

  • Lee, Kyungsu;Cho, Hanil;Lyu, Siwan;Rhee, Dong Sop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.456-460
    • /
    • 2016
  • 최근 기후변화의 영향과 급격한 도시화로 인한 하천 저류능력의 감소 및 부적절한 하수시설의 설계로 도시유역의 홍수 위험성이 증가하면서 적극적인 구조물적 홍수방어대책으로 대심도터널의 활용에 대한 필요성이 대두되고 있다. 일본을 비롯한 외국에서는 대심도터널의 활용이 적극적으로 고려되고 있으며 실제 설치 및 운영 사례 또한 증가하고 있다. 그러나 국내에서는 아직까지 홍수 방어용 대심도터널의 설치 및 운영된 사례가 없고 설계 및 시공과 관련한 기준 및 연구가 미미한 실정이다. 본 연구에서는 대심도터널 내부에서의 이상흐름 거동특성을 구명하기 위하여 터널을 모형화한 수평관에서 실험적 연구를 수행하였다. 직경 100 mm 투명 아크릴관으로 제작된 수평관 내부를 흐르는 물에 공기를 주입하여 기포를 발생시키고 전기전도계를 이용하여 유속변화에 따른 관에서의 물-공기 혼합 이상흐름의 거동특성에 대해 살펴보았다. 실험결과 터널 계통 전반에서의 물-공기(이상류) 거동 특성을 파악할 수 있었다. 이를 통해 대심도터널 내부 공기에 대한 효과적인 제어로 흐름의 안정화 및 그에 따른 수리성능의 개선효과를 기대할 수 있으며, 도시지역의 집중강우로 인한 수방재 대응 기술개발을 위한 기초자료로 활용할 수 있을 것으로 기대된다.

  • PDF