• Title/Summary/Keyword: 수직 평균거리

Search Result 100, Processing Time 0.032 seconds

Prostate Object Extraction in Ultrasound Volume Using Wavelet Transform (초음파 볼륨에서 웨이브렛 변환을 이용한 전립선 객체 추출)

  • Oh Jong-Hwan;Kim Sang-Hyun;Kim Nam-Chul
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.67-77
    • /
    • 2006
  • This thesis proposes an effi챠ent method for extracting a prostate volume from 3D ultrasound image by using wavelet transform and SVM classification. In the proposed method, a modulus image for each 2D slice is generated by averaging detail images of horizontal and vertical orientations at several scales, which has the sharpest local maxima and the lowest noise power compared to those of all single scales. Prostate contour vertices are determined accurately using a SVM classifier, where feature vectors are composed of intensity and texture moments investigated along radial lines. Experimental results show that the proposed method yields absolute mean distance of on average 1.89 pixels when the contours obtained manually by an expert are used as reference data.

Calculation of Photon Spectra from the Tungsten Target for 10 MeV Electron Beam (10 MeV의 전자선이 텅스텐 표적에 충돌하여 생성되는 광자선 스펙트럼의 계산)

  • 이정옥;정동혁;문성록;강정구;김승곤
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.55-62
    • /
    • 1999
  • In an effort to study the characteristics of x-rays utilized in radiation therapy, we calculated the energy distribution and the mean energy of x-rays generated from a tungsten target bombarded by 6, 10, and 15 MeV electron beams, using a Monte Carlo technique. The average photon energies calculated as a function of the beam radius lied in 1.4 ∼ 1.6, 2.1 ∼ 2.5 and 2.8 ∼ 3.3 MeV ranges for 4, 10, and 15 MV electron beams, respectively, which turned out to have no strong dependence on the radius. Using the energy distributions of 6,10, and 15 MV x-rays obtained for the target distance of 100 cm, percentage depth doses were determined using Monte Carlo calculations. For the case 10 MV, a comparison was made between our calculation and measurement performed by others. The calculated percentage depth dose appeared somewhat smaller than the measured one except in the surface region. We conclude that this is due to the fact that the beam hardening effect resulting from the flattening filter was not properly allowed for in our Monte Carlo calculations.

  • PDF

Evaluation of Fire Investigation as the Separation Distances for Several Types of Insulation Panels (단열패널 종류별 이격거리에 따른 화재감식 평가)

  • Kim, Jeong-Hun;Kim, Da-Seul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.403-412
    • /
    • 2021
  • Despite strengthening requirements for fire retardancy and applied buildings of insulation panels, the number of fires and influence of damage have increased. In this study, the thermal effects were evaluated as the separation distances, and three types of EPS panel, glass wool panel, and gypsum board panel were then selected. Temperature sensors on the panels were installed vertically from the ground. The fire source on the lamination layer of lumber was ignited by changes in the separation distances (0 cm, 25 cm, 50 cm) from the panels. The test results suggested that the maximum temperature was 349 ℃ in the EPS panel. The inside/outside shape changes were limited by the height of the low and middle positions until the critical point of a 25 cm separation distance. Furthermore, the combustion marks appeared after 500 s on average, and then the EPS panel with a high fire strength showed a broad "U type" pattern, glass wool panel, and gypsum board panel showed medium or narrow "V type" pattern. Therefore, the acquired data can provide valuable information for evaluating the fire risks and verifying fire investigation from buildings composed of these insulation panels.

Oceanic Skin-Bulk Temperature Difference through the Comparison of Satellite-Observed Sea Surface Temperature and In-Situ Measurements (인공위성관측 해수면온도와 현장관측 수온의 비교를 통해 본 해양 피층-표층 수온의 차이)

  • Park, Kyung-Ae;Sakaida, Futoki;Kawamura, Hiroshi
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.4
    • /
    • pp.273-287
    • /
    • 2008
  • Characteristics of skin-bulk sea surface temperature (SST) differences in the Northeast Asia seas were analyzed by utilizing 845 collocated matchup data between NOAA/AVHRR data and oceanic in-situ temperature measurements for selected months from 1994 to 2003. In order to understand diurnal variation of SST within a few meters of the upper ocean, the matchup database were classified into four categories according to day-night and drifter-shipboard measurements. Temperature measurements from daytime drifters showed a good agreement with satellite MCSST (Multi-Channel Sea Surface Temperature) with an RMS error of about $0.56^{\circ}C$. Poor accuracy of SST with an rrns error of $1.12^{\circ}C$ was found in the case of daytime shipboard CTD (Conductivity, Temperature, Depth) measurements. SST differences between MCSST and in-situ measurements are caused by various errors coming from atmospheric moist effect, coastal effect, and others. Most of the remarkable errors were resulted from the diurnal variation of vertical temperature structure within a few meters as well as in-situ oceanic temperatures at different depth, about 20 cm for a satellite-tracked drifting buoy and a few meters for shipboard CTD or moored buoy. This study suggests that satellite-derived SST shows significant errors of about ${\pm}3^{\circ}C$ in some cases and therefore it should be carefully used for one's purpose on the base of in-depth understanding of skin-bulk SST difference and vertical temperature structure in regional sea.

Effect of Vertically Rising Pressure Providing Spinal Canal Segment Motion on Symptom Relief in Patients with Parkinson's Disease (척추관 분절운동을 제공하는 수직 상승 압력이 파킨슨병 환자의 증상 완화에 미치는 영향)

  • Do-Hyun, Ahn;Hyeun-Woo, Choi;Kyung-Mi, Jung;Na-Young, Kim;Jong-Min, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.787-797
    • /
    • 2022
  • The purpose of this study was to confirm the reduction of pain and symptom relief of Parkinson's disease by vertically stimulating the spine through the application of a mechanical bed capable of thermal and massage stimulation. For this purpose, after confirming the segmental motion of the spine due to the use of a medical combination stimulation bed for Parkinson's disease patients, VAS, ODI, gait ability, and spiral drawing tests were performed, and the relationship between the variables was identified. In the 10-day visual analog scale and evaluation of low back pain dysfunction, the average trend of decreasing after bed use was confirmed. For walking ability, a decrease in the moving time and an increase in the moving distance were observed. In the spiral drawing test, the mean test time after using bed was significantly lower than before. As a result, it suggested the possibility of using it as an auxiliary method for recovery and pain relief of Parkinson's disease patients due to spinal segmental movement with mechanical heating and massage. However, this study is a preliminary study, and there is a small number of subjects, so additional research is needed that considers the number and condition of future subjects in detail.

The Comparison of Lens Movement by the Fitting States of Soft Contact Lenses in Normal and Dry Eyes (정상안과 건성안에서 피팅상태에 따른 각막에서의 소프트렌즈 움직임 비교)

  • Jung, Da I;Lim, Shin Kyu;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.21-30
    • /
    • 2011
  • Purpose: The study was performed to compare the differences in lens rotation, lens movement by blinking and lens centration with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified into the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment fitting or steep fitting. Lens rotation, lens movement by blinking and lens centration were separately measured immediately after lens wearing and after stabilization of tear film and compared by fitting states of soft contact lenses. Results: With steep fitting of soft contact lens in dry eyes, averaged lens rotation immediately after lens wearing was not significantly different from that of the normal eye group with alignment fitting however, lens rotation after stabilization in dry eyes was significantly larger than that in normal eyes. Any significant difference in lens movement by blinking was not shown in normal eyes. However, lens movement by blinking in dry eyes was increased with steep fitting. The range of lens centration on cornea in normal eyes with alignment fitting was more vertically distributed. On the other hand, the range of lens centration on cornea in dry eyes with alignment fitting was more horizontally distributed. Lens centration was shown to be changed by stabilization of tear film. That is, lens centrations were somewhat vertically widespread immediately after lens wearing and restrictively distributed in horizontal direction, respectively, with steep fitting in dry eyes. Conclusions: These results suggested that lens movements and centration in dry eyes were different from those of normal eyes. Especially, those differences between normal and dry eyes were much bigger with steep fitting of soft contact lenses. Thus, those differences should be considered for the comfortable and safe fitting of soft contact lens in dry eyes.

The Study of Relationship between Orofacial Pain and Natural Head Position or Life Stress. (두부 자세, 스트레스 정도에 따른 구강안면통증)

  • Lee, You-Mee;Lim, Hyun-Dae
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.2
    • /
    • pp.147-154
    • /
    • 2006
  • This paper studies natural head position and orofacial pain. For this study. 27 persons with dental service were selected, we examine head & neck pain, factor affecting pain severity, stress, stressful facial symptom with questionarre and interview. We have photograph for natural head position in front of 5cm posture scale pate. Data obtained were statistically processed by the SPSS Windows program and the results of this study were as follows: 1. There were significant difference from plum line to acromion line, from plum line to tragus line, eye- tragus angle, SCM angle. 2. Between group with head and neck pain and group without head and neck pain, the study shows no significant difference on average NHP measurement and NHP amount. 3. Between group with head and neck pain and group without head and neck pain, the study shows no significant difference on SRRS. 4. In this paper we indicate more stressful symptom in group with head and neck pain than group without head and neck pain. 5. There have no difference in head and neck pain level according to hobby.

Accuracy assessment of implant placement using a stereolithographic surgical guide made with digital scan (디지털 스캔을 이용하여 제작된 임플란트 수술가이드의 정확도)

  • Jeong, Seung-Mi;Fang, Jeong-Whan;Hwang, Chan-Hyeon;Kang, Se-Ha;Choi, Byung-Ho;Fang, Yiqin;Jeon, Hyongtae;An, Sunghun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.111-119
    • /
    • 2015
  • Purpose: The objective of this study was to evaluate the accuracy of a stereolithographic surgical guide that was made with information from intraoral digital impressions and cone beam CT (CBCT). Materials and methods: Six sets of resin maxilla and mandible models with missing teeth were used in this study. Intraoral digital impressions were made. The virtual models provided by these intraoral digital impressions and by the CBCT scan images of the resin models were used to create a surgical guide. Implant surgery was performed on the resin models using the surgical guide. After implant placement, the models were subjected to another CBCT scan to compare the planned and actual implant positions. Deviations in position, depth and axis between the planned and actual positions were measured for each implant. Results: The mean deviation of the insertion point and angulation were 0.28 mm and $0.26^{\circ}$, apex point were 0.11 mm and 0.14 mm respectively. The implants were situated at a mean of 0.44 mm coronal to the planned vertical position. Conclusion: This study demonstrates that stereolithographic surgical guides created without the use of impressions and stone models show promising accuracy in implant placement.

Anatomical Characteristics of the Mandibular Median Lingual Foramen: the Assessment of the CBCT (CBCT를 이용한 하악 정중설공의 해부학적 평가)

  • Lee, Go-Woon;Kim, Ok-Su
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.337-346
    • /
    • 2013
  • It is necessary to consider the median lingual foramen carefully to prevent the bleeding due to the damage of the sublingual artery for implant surgery. This study is to evaluate the frequency, location, diameter and the number of the Mandibular median lingual foramen regarding gender and age in the CBCT. Sixty two images of cone beam computed tomography (CBCT) whose visited the Chonnam National University Dental hospital from Sept. 2010 to Apr. 2011 were evaluated. Frequency, number, location and the diameter of Mandibular median lingual foramen shown in the CBCT image were evaluated. Sixty two patients (100%) had at least one median lingual foramen and fifty six patients (90.32%) had multiple foramens. Forty patients (66.13%) showed the median lingual foramen on the location between Mn. central incisors. The mean vertical position of the genial spine and the median lingual foramen was 24.21 mm and 14.52 mm, respectively. And the relative mean vertical dimension of median lingual foramen was 0.45. The mean diameter of the foramen was 0.93 mm. CBCT demonstrated the frequency, location, diameter and the number of median lingual foramen. It is necessary to take CBCT before implant placement to prevent the bleeding.

Efficiency on the Field Edge Block which was used at Junction Field of Head & Neck Cancer in the Radiotherapy (두경부 종양의 방사선치료 시 접합 조사야에 사용된 조사면 끝단 차폐물의 유용성)

  • Lee, Jae-Seung;Kim, Jung-Nam
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.235-241
    • /
    • 2008
  • If the target volume cannot be included with one field at head and neck cancer, we commonly used two or more field. It is very important to irradiate uniform dose at junction area of the fields. However, according to body shape of patient or general condition of patient, skin junction area can be matched incorrect, So overdose area or underdose area can be appeared in the junction area. This study researched therapy technique which can give uniform dose at skin junction owing to applying the edge block of lateral field at head and neck cancer. We measured the changed distance and rotational angle between central line of anterior supraclavicle lymph node and low margin of right lateral field on simulation process using the shielding block of variable rotation. As a result, the changed distance between central line of anterior supraclavicle lymph node and low margin of right lateral field was below 2mm to ${\pm}$10cm distance at central line of Y axis, changed angle was average 1.28 degree. But by using it the shielding block of variable rotation, the incorrect match at junction can be minimized. We think that this technique is very efficient one to apply this technique at head and neck cancered by the movement of organs can be not included, Therefore we have to pay attention on the process to imput MLC layer