• Title/Summary/Keyword: 수직이상점

Search Result 160, Processing Time 0.028 seconds

Trend Analyses of B777 FLCH Usage Beyond FAF Events (B777 항공기 Final Approach Fix(FAF) 이후 Flight Level Change(FLCH) 사용 이벤트 경향성 분석)

  • Chung, Seung Sup;Kim, Hyeon Deok
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.3
    • /
    • pp.248-255
    • /
    • 2021
  • The main causes of the July 2013 OZ 214 accident were poorly performed approach and the failure to recognize the autothrottle in the HOLD position which the automated speed control was not provided. The pilots late decision for go-around was also a critical factor leading to the accident. The B777 POM restricts the use of FLCH mode beyond the FAF. This research utilized the QAR data of an airline's B777 fleet in the period of two years where 44 cases were found. In many cases, the FLCH mode was used for rapid descent from an higher than normal situation. In addition, in the base turn, continuous use of FLCH mode even when the path was below the glide path were observed. Airports with elevation above 500 ft MSL had a higher rate of occurrence. In this research, the proper descent planning and vertical path monitoring, and the adherence to the limitation set in the manuals and the stabilized approach criteria were re-emphasized as mitigation to reduce event occurences.

A study on the validity of reference points for edentulous patient (무치악 환자를 위한 참고점들의 효용성에 대한 연구)

  • Park, Jeong-Jae;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.310-317
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the validity of reference points for edentulous patient by examining the correlation of teeth and face, and intraoral anatomic landmarks. Materials and methods: We examined a facial outline, length, bizygomatic width, nasion - gnathion length, glabella - nasion distance in 270 men and 280 women satisfied with inclusion criteria from Seoul National School of Dentistry. The shape of maxillary central incisor, mesiodistal crown width and length of maxillary 6 incisors, distance from incisive papilla to labial surface of maxillary central incisor, and perpendicular distance from incisive papilla to intercanine line were measured in the stone model. We analyzed the ratio and relevant relation statistically. Results: The probability on having the same shape of face and the relative same shape maxillary incisor was 55.56% and 46.43% for men and women. The facial length proved to be a more valuable measurement in women in the tooth selection. The ratio of bizygomatic width to mesiodistal width of maxillary central incisor, and the ratio of bizygomatic width to width of maxillary 6 incisors were 16.8 : 1 and 3.0 : 1 and were positively correlated with each other. The distance of the canines from the maxillary incisal papilla was $1.33{\pm}1.28mm$. The distance between the center of the incisal papilla and the labial surface of their maxillary central incisor was $9.23{\pm}1.20mm$. Conclusion: It was showed that anatomical reference points in tooth selection and arrangement for edentulous patient are useful and have validity in our limited study.

Subjective Evaluation about Ideal Position of the Subnasale on Lateral Photos (측모 사진상에서 Subnasale의 이상적인 위치에 관한 주관적 평가)

  • Kim, Yi-Dong;Chung, Dong-Hwa;Cha, Kyung-Suk;Lee, Jin-Woo;Lee, Sang-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.347-358
    • /
    • 2013
  • When analyzing soft tissue of the profile, Subnasale is often used as an important reference point. But there are few studies on the ideal position of the Subnasale. Therefore, the purpose of this study is to present an objective reference of the esthetic face relating to the change of Subnasale position in Koreans' profile, and also to determine whether there is concordance between professionals and laypersons in their perception of facial attractiveness. The one determined as appropriate profile portion by experts of pictures taken in women in 20s was selected. The photograph was modified changing the Subnasale anteroposteriorly on the plane perpendicular to the true vertical line, while maintaining the nasolabial angle. The photographs were presented to a group of professionals (9 orthodontists) and 126 laypersons, who were asked to assess the facial attractiveness of the photographs on a VAS independently. The conclusion was obtained. 1. The ideal position of the Subnasale is when the ratio of the distance Lateral canthus~Subnasale : Subnasale~Pronasale is 1.769 : 1. 2. The ideal degrees between the true vertical line passing through Nasion and Subnasale is $5.5^{\circ}$ 3. The professionals recognized every change in the ratio, but the laypersons couldn't differentiate between the change from 1.571 : 1 to 1.769 : 1.

Web-based Moving Object Tracking by Controlling Pan-Tilt Camera using Motion Detection (움직임 검출의 캠 제어에 의한 웹기반 이동 객체 추적)

  • 박천주;박희정;이재협;전병민
    • The Journal of the Korea Contents Association
    • /
    • v.2 no.2
    • /
    • pp.17-26
    • /
    • 2002
  • In this paper, we suggest a method to acquire the moving object centered video by panning and tilting a camera automatically according to motion vectors calculated by detecting the motion of a moving object on video steam. We create a difference image by estimating the intensity difference at the grid points of neighboring frames. And we detect the motion using both horizontal projection histogram and vertical projection histogram and decide the center of motion part. Then we calculate a new direction and degree of the motion by comparing coordinates at the center of current motion and the center of previous motion. By controling the RCM using these Motion vectors, we can get video stream positioned unwire object on the center of video frame. Through the experiments, we could get a moving object centered video stream continuously arid monitor remotely by implementing sever/client architecture based on the web.

  • PDF

Isocenter Reproducibility with Mask Fixation System in Stereotactic Radiosurgery (정위 마스크 시스템을 사용한 방사선수술시 회전중심점의 재현성)

  • 이동준;손문준;이기택;최찬영;황금철;황충진
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.135-138
    • /
    • 2002
  • Fractionated stereotactic radiosurguy (FSRS) requires precise and reproducible patient set up. For these reasons non-invasive mask fixation methods have been used in Linac based FSRS. In this study, we measured and assessed the isocenter reproducibility using a commercial head mask fixation system based on thermoplastic materials. For the verification and the measurement of isocenter deviation a special acrylic brain phantom was designed. The designed phantom has 22 vertical rods and each rod has different lengths. At the end of the 8 rods, the monochromic film is attached and irradiated due to planned target position. Deviations of isocenter were measured separately for each direction. The mean deviation showed 0.4 mm in longitudinal direction, 0.1 mm in the lateral direction, 0.1 mm in the anterior-posterior direction of the treatment couch. The data demonstrates the high accuracy and reproducibility. This study reinforces previous literature published.

  • PDF

Calculation and measurement of optical coupling coefficient for bi-directional tancceiver module (양방향 송수신모듈 제작을 위한 광결합계수의 계산 및 측정)

  • Kim, J. D.;Choi, J. S.;Lee, S. H.;Cho, H. S.;Kim, J. S.;Kang, S. G.;Lee, H. T.;Hwang, N.;Joo, G. C.;Song, M. K.
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.500-506
    • /
    • 1999
  • We designed and fabricated a bidirectional optical transceiver module for low cost access network. An integrated chip forming a pin-PD on an 1.3 urn FP-LD was assembled by flip-chip bonding on a Si optical bench, a single mode fiber with an angled end facet was aligned passively with the integrated chip on V-groove of Si-optical bench. Gaussian beam theory was applied to evaluate the coupling coefficients as a function of some parameters such as alignment distance, angle of fiber end facet, vertical alignment error. The theory is also used to search the bottle-neck between transmittance and receiving coupling efficiency in the bi-directional optical system. Tn this paper, we confirmed that reduction of coupling efficiency by the vertical alignment error between laser beam and fiber core axis can be compensated by controlling the fiber facet angle. In the fabrication of sub-module, a'||'&'||' we made such that the fiber facet have a corn shape with an angled facet only core part, the reflection of transmitted laser beam from the fiber facet could be minimized below -35 dE in alignment distance of 2: 30 /J.m. In the same condition, transmitted output power of -12.1 dEm and responsivity of 0.2. AIW were obtained.

  • PDF

A Feasibility Study for Mapping Using The KOMPSAT-2 Stereo Imagery (아리랑위성 2호 입체영상을 이용한 지도제작 가능성 연구)

  • Lee, Kwang-Jae;Kim, Youn-Soo;Seo, Hyun-Duck
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.1
    • /
    • pp.197-210
    • /
    • 2012
  • The KOrea Multi-Purpose SATellite(KOMPSAT)-2 has a capability to provide a cross-track stereo imagery using two different orbits for generating various spatial information. However, in order to fully realize the potential of the KOMPSAT-2 stereo imagery in terms of mapping, various tests are necessary. The purpose of this study is to evaluate the possibility of mapping using the KOMPSAT-2 stereo imagery. For this, digital plotting was conducted based on the stereoscopic images. Also the Digital Elevation Model(DEM) and an ortho-image were generated using digital plotting results. An accuracy of digital plotting, DEM, and ortho-image were evaluated by comparing with the existing data. Consequently, we found that horizontal and vertical error of the modeling results based on the Rational Polynomial Coefficient(RPC) was less than 1.5 meters compared with the Global Positioning System(GPS) survey results. The maximum difference of vertical direction between the plotted results in this study and the existing digital map on the scale of 1/5,000 was more than 5 meters according as the topographical characteristics. Although there were some irregular parallax on the images, we realized that it was possible to interpret and plot at least seventy percent of the layer which was required the digital map on the scale of 1/5,000. Also an accuracy of DEM, which was generated based on the digital plotting, was compared with the existing LiDAR DEM. We found that the ortho-images, which were generated using the extracted DEM in this study, sufficiently satisfied with the requirement of the geometric accuracy for an ortho-image map on the scale of 1/5,000.

Changes of bite force and occlusal contacts after stabilization splint therapy (교합안정장치 사용후 교합력 및 교합접촉의 변화양상에 관한 연구)

  • Park, Hyung-Soo;Kim, Kwang-Won;Yoon, Young-Jooh
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.91-99
    • /
    • 2000
  • This study was done to identify the changes of bite force and occlusal contact between before and after stabilization splint therapy. 16 female patients, accepted for orthodontic treatment at the Department of Orthodontics, College of Dentistry, Chosun University, were selected as the sample of this investigation. For comparisons, the samples of 16 were divided into just before stabilization splint, 1 month after stabilization splint, 2 months after stabilization splint, and 3 months after stabilization splint and used the T-scan system to identify the bite force and occlusal contact changes for each group. Statistical analysis of the data was carried out ANOVA tests, and Turkey tests using $SPSS/PC^+$. The results were as follows : 1. Bite force change from just before treatment to 1 month after stabilization splint therapy was statistical significantly decreased (P<0.05). 2. Bite force changes from 1 to 3 months after stabilization splint therapy showed no statistical significance (p>0.05). 3. The changes of anterior occlusal contacts showed no statistical significance regardless of the wearing periods of stabilization splint (P>0.05). 4. The changes of posterior occlusal contacts from just before treatment to 1 month after stabilization splint therapy was statistical significantly decreased (P<0.05). 5. The changes of posterior occlusal contacts Outing 1 to 3 months after stabilization splint therapy showed no statistical significance (P>0.05). 6. Posterior teeth rather than anterior teeth were more influenced by the changes of the number of occlusal contacts. To sum up above results, we may respect to capturing and stabilizing centric relation Position just 1 month after stabilization splint therapy.

  • PDF

KSTAR 진공용기 시작품 제작관련 기술분석

  • 조승연
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.36-36
    • /
    • 1999
  • 한국중공업(주)에서 수행한 KSTAR 진공용기 시작품 제작이 완성됨에 따라 제작과 관련된 종합기술을 분석하여 보았다. KSTAR 진공용기 시작품(그림1)은 전체의 1/4섹터인 90도 부분으로서 NBI(Neutral Beam Injection) 포트를 포함하는 45도 섹터와 축소포트(Reduced Port)를 포함하는 45도 섹터를 각각 먼저 제작한 후 두 부분을 용접하여 최종 시작품을 완성하였다. 용접은 SMAW법과 GTAW법 등 두가지 방법을 사용하였으며, 초기 용접시는 용접 면적이 작기 때문에 GTAW법을 이용하였고, 마무리 용접과 같이 용접 면적이 넓고 거친 부분에는 SMAW법을 이용하여 용접하였다. 모든 용접이 완전통과 용접이기 때문에 구조적 안전 면에서 좋으나, 진공측면에서는 다소 미흡한 점이 있다. 시작품은 상하 대칭구조로서 원통부분, 원형부분, 원추부분, 너클부분 (그림2) 등으로 나뉘어 지며 이중 원형품은 금형을 이용하여 성형하였고, 나머지 부분은 굽힘가공 후 절단적업을 하였다. 진공용기 조립은 안쪽과 바깥쪽 내벽부터 용접한 후 폴로이달 리브를 용접하고 외벽을 용접한다. 수평포트와 수직포트를 위해 스터브를 용접한 후 미리 용접해둔 NBI 포트 및 축소포트를 부착시켰다. 용접부위의 누설시험을 위한 방법으로, 용접주위 표면에서 개구하고 있는 홈에 적색 침투액을 침투시켜 침투 후 이 액을 홈의 개구로부터 빨아 내어 용접부위 표면상태에서 실제의 홈의 폭보다 확대한 홈의 지시모양으로 나타내게 하여 누설여부를 알기 쉽게 하는 액체 침투 탐상법을 적용하였다. 지시모양의 크기가 5mm 이상인 부분에 대해서는 재용접을 하였다. 누설 시험으로 초음파 탐상시험이 본제품 제작시 수행되어야 한다. 완성된 시작품에 대해 3군데의 위치에서 각각의 부분들이 용접되기 전과 후에 치수를 각각 측정하여 비교하였다. 또한 포트들에 대해서도 용접 전후 치수를 각각 측정하였다. 이러한 측정은 줄자를 사용하여 측정하였으므로 차 후 3차원 정밀 측정이 수반되어야 한다. 이상과 같이 시작품 제작을 통하여 문제점을 파악하고 개선책을 마련함으로서 향 후 KSTASR 진공용기 본 제품 제작할 때 반영코자 한다.

  • PDF

Counter-Current Flow Limitation Model Based on the Hyperbolic Two-fluid Equations and Interface Shape Function (쌍곡선형 이상유동 방정식과 경계면 모양함수를 이용한 유체기계의 역류유동제한점 예측방법 개발)

  • 정지환
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.1
    • /
    • pp.15-22
    • /
    • 2000
  • There are lots of industrial machines of which functions are achieved by operation of multi-phase fluids. Some of them take advantage of the characteristics of counter-current two-phase flow The maximum flow rates of gas and liquid phases which flow in opposite-directions (counter-current flow) are limited by a phenomenon known as a Counter-Current Flow Limitation (CCFL or Flooding) The mass and momentum conservation equations for each Phase were established to build a first-order hyperbolic partial derivative equations system. A new CCFL model is developed based on the characteristic equation of the hyperbolic PDE system. The present model has its applicationto the case in which a non-uniform flow is developed around a square or sharp-edged entrance of liquid phase. The model is able to he used to Predict the operating-limit of components in which mass and heat transfer are taking place between liquid and gas phases.

  • PDF