• Title/Summary/Keyword: 수의 영상진단

Search Result 1,908, Processing Time 0.027 seconds

The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning (18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과)

  • Cha, Sangyoung;Cho, Yonggwi;Lee, Yongki;Song, Jongnam;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • In this study, among various factors having influence on SUV, we intended to compare and analyze the change of SUV using CT(4 type) and MRI(3 type) contrast agents which are commercialized now. We used Discovery 690 PET/CT(GE) and NEMA NU2 - 1994 PET phantom as experimental equipment. We have conducted a study as follows; first, we filled distilled water to phantom about two-thirds and injected radioisotope(18F-FDG 37 MBq), contrast agent. Second, we mixed CT contrast agent with distilled water and MRI contrast agent with that water separately. And then, we stirred the fluid and filled distilled water fully not to make air bubble. In emission scan, we had 15minutes scanning time after 40 minutes mixing contrast agent with distilled water. In transmission scan, we used CT scanning and its measurement conditions were tube voltage 120 kVp, tube current 40 mA, rotation time 0.5 sec, slice thickness 3.27 mm, DFOV 30 cm. Analyzing results, we set up some ROIs in 10th, 15th, 20th, 25th, 30th slice and measured SUVmean, SUVmax. Consequently, all images mixed 3 types of MRI contrast agent with distilled water have high SUVmean as compared with pure FDG image but there was no statistical significance. In SUVmax, they have high score and there was statistical significance. And other 4 images mixed 4 types of CT contrast agent with distilled water have significance in both SUVmean and SUVmax. Attenuation correction in PET/CT has been executed through various methods to make high quality image. But we figured out that using CT and MRI contrast agents before PET/CT scanning could make distortion of image and decrease diagnostic value. In that reason, we have to sort out the priority of examination in hospital not to disturb other examination's results. Through this process, we will be able to give superior medical service to our customers.

Influence of Gating and Attenuation-correction for Diagnostic Performance of Usual Rest/stress Myocardial Perfusion SPECT in Coronary Artery Disease (게이트 방법과 감쇠보정이 심근 관류 SPECT의 관상동맥질환 진단 성능에 미치는 영향)

  • Lee, Dong-Soo;Yeo, Jeong-Seok;So, Young;Cheon, Gi-Jeong;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.131-142
    • /
    • 1999
  • Purpose: Either gated myocardial perfusion SPECT or attenuation corrected SPECT can be used to improve specificity in the diagnosis of coronary artery disease. We investigated in this study whether gating or attenuation correction improved diagnostic performance of rest/stress perfusion SPECT in patients having intermediate pre-test likelihood of coronary artery disease. Materials and Methods: Sixty-eight patients underwent rest attenuation-corrected T1-20l/dipyridamole stress gated attenuation-corrected Tc-99m -MIBI SPECT using an ADAC vertex camera (M:F=29:39, aged $59{\pm}12$ years, coronary artery stenosis ${\geq}70%$, one vessel: 13, two vessel: 18, three vessel: 8, normal: 29). Using a five-point scale, three physicians graded the post-test likelihood of coronary artery disease for each arterial territory (1:normal, 2: possibly normal, 3:equivocal, 4. possibly abnormal, 5: abnormal). Sensitivity, specificity and area under receiver-operating-characteristic curves were compared for each operator between three methods : (A) non-attenuation-corrected SPECT; (B) gated SPECT added to (A): and (C) attenuation-corrected SPECT added to (B). Results: When grade 3 was used as the criteria for coronary artery disease, no differences in sensitivity and specificity were found between the three methods for each operator. Areas under receiver-operating-characteristic curves for diagnosis of coronary artery disease revealed no differences between each modality (p>0.05). Conclusion: In patients at intermediate risk of coronary artery disease, gated SPECT and attenuation- corrected SPECT did not improve diagnostic performance.

  • PDF

Change of Cerebral Blood Flow Distribution and Vascular Reserve according to Age in Koreans Measured by Tc-99m HMPAO Brain SPECT (한국 정상인에서 연령에 따른 뇌혈류분포와 혈류예비능의 변화: Tc-99m HMPAO SPECT에 의한 연구)

  • Song, Ho-Cheon;Bom, Hee-Seung;Sohn, Hye-Kyung;Jeong, Hwan-Jeong;Min, Jung-Jun;Kim, Ji-Yeul;Lee, Jae-Tae;Moon, Dae-Hyuk;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.247-261
    • /
    • 1999
  • Purpose: The aim of this study was to evaluate the normal values of regional cerebral blood flow (rCBF) and cerebrovascular reserve (CVR) in normal children to aged volunteers using Tc-99m HMPAO, Materials and Methods: Thirty four right-handed normal volunteers (20 males, 14 females, mean age $40.3{\pm}24.9$ years, range 4 to 82 years) were underwent rost/acetazolamide (ACZ) brain SPECT using Tc-99m HMPAO and the sequential injection and subtraction method. rCBF was estimated on the basis of a semiquantitative approach by means of right/left ratio, region/cerebellum and region to whole brain ratios in (rental, parietal, temporal, and occipital lobes, basal ganglia, thalami, and cerebellum. CVR was measured by means of % perfusion increase calculated as % mean count change compared to rest rCBF in each regions. Results: Mean values of right to left ratios range from 1.004 to 1.018, rCBF was highest in cerebellum and lowest in basal ganglia and thalami. Frontal and temporal rCBF decreased while occipital and thalamic rCBF increased according to age. No sexual difference of rCBF was noted. Mean CVR was $29.9{\pm}12.9%$. Mean CVR significantly increased to late teens, and declined thereafter. After 6th decade, CVR in both frontal lobes, left parietal lobe and right basal ganglia decreased significantly with advancing age. There was no sexual difference of CVR. Conclusion: Quantitative assessment of CVR was possible by ACZ Tc-99m HMPAO brain SPECT. It revealed that rCBF and CVR changed according to age in normal Korean volunteers. There was no sexual difference.

  • PDF

Risk Factors and Prognosis for Periventricular Leukomalacia According to Neuroimage in Preterm Infants (미숙아 뇌실주위 백질연화증에서 뇌영상 분류에 따른 예후와 위험인자)

  • Ahn, Jung-Hee;Seo, Yoo-Jin;Yoon, Jung-Rim;Shim, Gyu-Hong;Kim, Seong-Hee;Cho, Woo-Ho;Chey, Myoung-Jae
    • Neonatal Medicine
    • /
    • v.17 no.1
    • /
    • pp.64-74
    • /
    • 2010
  • Purpose : The aim of this study was to determine the risk factors, clinical characteristics and prognosis for the development of periventricular leukomalacia (PVL) in preterm infants according to the extent and site of the PVL. Methods : The medical records of infants (under 36 weeks of gestational age) delivered from January 1999 to December 2008 were reviewed. Twenty-five preterm infants with were PVL were diagnosed by brain magnetic resonance imaging (MRI) and an addition 50preterm infants with no brain lesions were enrolled in this study. The perinatal and neonatal risk factors for the development of PVL was determine in these infants. Mental and Psychomotor Developmental Indices (MDI, PDI) were assessed by a clinical psychologist using the Bayley Scales of Infant Development II. We compared the differences of the clinical characteristics and prognosis according to brain MRI findings. Results : Maternal fever, young maternal age, extended oxygen use, hypotension within the first week of birth, use of inotropics within the first week of birth, and respiratory distress syndrome were the risk factors associated with PVL (P <0.05). In the multivariate analysis, maternal fever and extended oxygen use were statistically significant independent risk factors (P <0.05). The mean MDI and PDI scores of the PVL group (74.4$\pm$ 27.8 and 58.0$\pm$17.7) were significantly lower than those of the control group (103.5$\pm$8.9 and 101.7$\pm$16.1, P <0.05). Conclusion : Maternal fever and extended oxygen use were independent risk factors for PVL. We should pay attention to infants who had the risk factors and follow them up closely by brain imaging study and Bayley Scales of Infant Development II.

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

Comparison of digital models generated from three-dimensional optical scanner and cone beam computed tomography (3차원 광학 스캐너와 콘빔CT에서 생성된 디지털 모형의 비교)

  • Kwon, Hyuk-Jin;Kim, Kack-Kyun;Yi, Won-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.60-69
    • /
    • 2016
  • Purpose: The objective of this study was to compare the accuracy of digital models from 3 dimentional (3D) optical scanner and cone beam computed tomography (CBCT). Materials and Methods: We obtained digital models from 11 pairs of stone casts using a 3D optical scanner and a CBCT, and compared the accuracy of the models. Results: The error range of average positive distance was 0.059 - 0.117 mm and negative distance was 0.066 - 0.146 mm. Statistically (P < 0.05), average positive distance was larger than $70{\mu}m$ and shorter than $100{\mu}m$, and that of negative distance was larger than $100{\mu}m$ and shorter than $120{\mu}m$. Conclusion: We concluded that the accuracy of digital models generated from CBCT is not appropriate to make final prostheses. However, it may be acceptable for provisional restorations and orthodontic diagnoses with respect to the accuracy of the digitalization.

Evaluation of Usefulness of Image by Using New Compression Paddle for Mammoplasty Patient During Mammography (유방촬영 시 유방보형물 환자에 대한 새로운 압박대 적용의 유용성 평가)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.229-235
    • /
    • 2015
  • Mammoplasty is currently increasing not only for cosmetic surgery, but as well as for the recovery after breast cancer surgery. The prostheses inserted into the breasts of women who have undergone mammoplasty, hide the breast substances and it is becoming increasingly difficult to diagnose breast disease, and fear is growing by the concern of the prostheses bursting by the strap. So we want to develop a strap applicable to women with prostheses inserted, to determine the usefulness, and we also want to compare the utility by comparing the total area of the Inner and Outer parts of the breast and Posterior Nipple Line (PNL), after obtaining video by applying the existing strap and the developed strap to phantom of the prostheses inserted patient shape. When the pressure by the developed pressure, the total area increased by 10.09% from CC view to $9,813.797mm^2$, 3.88% from CC-ID view to $7,621.531mm^2$, PNL increased by 3.41% from CC view to $90.916mm^2$, 1.64% from CC-ID view to$75.357mm^2$. And the breast tissue of the thorax side increased 3.53% from CC view to $177.725mm^2$, and 6.57% from CC-ID view to $152.510mm^2$, and we could verify that the prostheses were completely eliminated in the CC-ID images of developed strap, compared with the existing strap.

Development of inside-out probes for both Nuclear Magnetic Resonance Imaging and Nuclear Magnetic Resonance Spectroscopy (핵자기공명 영상법과 핵자기공명 분광법을 위한 뒤집음-탐침의 개발에 대한 연구)

  • Lee, Dong-Hun;Go, Rak-Gil;Jeong, Eun-Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.309-316
    • /
    • 1995
  • RF (radio-frequency) probes of Nuclear Magnetic Resonance are one of the important factors and should be designed and built properly depending upon the geometry of the samples and the information. In general there are two kinds of rf probes : one encircles the sample while the other is placed on the surface of the sample. However, in case that the samples on human internal organs have a tube shape, the two kinds of rf probes, as specified above, are usually unsuitable for the internal imaging due to the degradation of signal-to-noise ratios (SNR's). In this case a probe should be positioned as close to the area as possible by putting the probe in the tubelike sample to improve filling factor In the present study inside-out probes have been constructed in the three different shapes such as an anti-solenoidal, a saddle and a dual surface types. RF-field distributions have also been calculated depending upon the geometrical changes of anti-solenoid probes. Moreover, the performance of the inside-out probes has been checked by measuring SNR's of the images acquired. The inside-out probes constructed in this study produced better SWR's and rf-field uniformity in the area close to the probes in comparing with any other commercial probes. There is a high feasibility that the constructed probes in the present study are applicable to the diagnosis of human bodies.

  • PDF

A Case of Ependymoma in a Dog; Computed Tomography, Histopathological and Immunohistochemical Findings (개에서 발생한 뇌실막종 증례; 컴퓨터 단층영상, 조직병리학적 그리고 면역조직화학적 소견)

  • Lee, Hee-Chun;Kim, Na-Hyun;Cho, Kyu-Woan;Jung, Hae-Won;Moon, Jong-Hyun;Kim, Ji-Hyun;Sur, Jung-Hyang;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.31 no.2
    • /
    • pp.117-120
    • /
    • 2014
  • An 11-year-old intact female Maltese was referred because of 1 week history of cluster seizure episodes. Based on brain CT scan, brain tumor was strongly suspected. The patient was euthanized according to client's request and we performed necropsy after euthanasia. The gross findings of the postmortem coronal sections of the brain showed that the mass was relatively well-demarcated, reddish in colored, and was present inside the left lateral ventricle and compressed adjacent tissues. The tumor mass had 2 distinct histopathological features: perivascular pseudorosette-like structures and a whirl-like arrangement of fibrillary cells. The immunohistochemical profile showed strong GFAP positivity and moderate S-100 expression, sparsely dotted staining with Ki-67. Based on the histopathological and immunohistochemical findings, the present case diagnosed to ependymoma.

A Prostate Segmentation of TRUS Image using Average Shape Model and SIFT Features (평균 형상 모델과 SIFT 특징을 이용한 TRUS 영상의 전립선 분할)

  • Kim, Sang Bok;Seo, Yeong Geon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.1 no.3
    • /
    • pp.187-194
    • /
    • 2012
  • Prostate cancer is one of the most frequent cancers in men and is a major cause of mortality in the most of countries. In many diagnostic and treatment procedures for prostate disease, transrectal ultrasound(TRUS) images are being used because the cost is low. But, accurate detection of prostate boundaries is a challenging and difficult task due to weak prostate boundaries, speckle noises and the short range of gray levels. This paper proposes a method for automatic prostate segmentation in TRUS images using its average shape model and invariant features. This approach consists of 4 steps. First, it detects the probe position and the two straight lines connected to the probe using edge distribution. Next, it acquires 3 prostate patches which are in the middle of average model. The patches will be used to compare the features of prostate and nonprostate. Next, it compares and classifies which blocks are similar to 3 representative patches. Last, the boundaries from prior classification and the rough boundaries from first step are used to determine the segmentation. A number of experiments are conducted to validate this method and results showed that this new approach extracted the prostate boundary with less than 7.78% relative to boundary provided manually by experts.