• Title/Summary/Keyword: 수은 이온

Search Result 97, Processing Time 0.035 seconds

A Highly Selective Mercury(II) Ion-Selective Membrane Sensor (고 선택성 수은(II) 이온 막 센서)

  • Ensafi, Ali A.;Meghdadi, S.;Allafchian, Ali R.
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.4
    • /
    • pp.324-330
    • /
    • 2007
  • A new ion selective PVC membrane electrode is developed as a sensor for mercury(II) ions based on bis(benzoylacetone) propylenediimine (H2(BA)2PD) as an ionophore. The electrode shows good response characteristics and displays, a linear Emf vs. log[Hg2+] response over the concentration range of 1.0×10-6 to 1.0×10-1 M Hg(II) with a Nernstian slope of 29.8±0.75 mV per decade and with a detection limit of 2.2×10-7 M Hg(II) over the pH range of 2.5-11.5. Selectivity concentrations for Hg(II) relative to a number of potential interfering ions were also investigated. The sensor is highly selective for Hg(II) ions over a large number of cations with different charge. The sensor has been found to be chemically inert showing a fast response time of 60 s and was used over a period of 3 months with a good reproducibility (S = 0.27 mV). The electrode was successfully applied to determine mercury(II) in real samples with satisfactory results.

고밀집 섬유집합체에 의해 유도된 모세관현상을 이용한 순환식 수은전극 전해계의 개발과 그 특성 연구

  • 김광욱;변기호;이일희;유재형;박현수
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.565-570
    • /
    • 1996
  • 본 연구에서는 고밀집 섬유다발체 내에 수은과 금속이온을 함유한 수용액을 동시에 주입시켜 최소 공간에서 최대한의 수은전극 면적을 갖는 수직형 순환식 수은 모세관 다발체 전극 전해반응 장치가 개발되었다. 이장치의 특성과 안정성을 평가하기 위해 수은과 수용액의 유량 변화에 따른 철(III)과 우라늄(IV)이온의 환원 voltammogram 이 측정되었다. 본 연구에서 개발된 수직형 순환식 수은 모세관 다발체 전극 전해계는 정확히 제어되는 수용액 유량조건에서 수용액내의 금속이온의 산화수 상태 및 농도의 연속적인 분석 및 전해반응 기구 해석에 효과적으로 사용될 수 있음을 알 수 있었다.

  • PDF

Selective determination of mercury (II) ion in aqueous solution by chemiluminescence method (화학발광법에 의한 수용액 중의 선택적 수은(II) 이온 정량)

  • Kim, Kyung-Min;Jang, Taek-Gyun;Kim, Young-Ho;Oh, Sang-Huyb;Lee, Sang-Hak
    • Analytical Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.243-248
    • /
    • 2011
  • A selective determination method of mercury (II) ion in aqueous solution by luminol-based chemiluminescence system (luminol CL system) has been developed. Determination of metal ions such as copper (II), iron (III), chromium (III) ion in solution by the luminol CL system using its catalytic role in the reaction of luminol and hydrogen peroxide has been reported by several groups. In this study, the catalytic activity of mercury (II) ion in the reaction of luminol and hydrogen peroxide was observed by the enhanced CL intensity of the luminol CL system. Based on this phenomenon, experimental conditions of the luminol CL system were investigated and optimized to determine mercury (II) ion in aqueous solution. While mercury (II) ion in mixed sample solution containing mercury (I) and (II) ions highly enhanced the CL intensity of the luminol CL system, the mercury (I) ion could not enhanced the CL intensity. Thus selective determination of the mercury (II) ions in a mixture containing mercury (I) and (II) ions could be achieved. Each concentration of mercury (I) and (II) ions in aqueous solution can be obtained from the results of the CL method that give the concentration of only mercury (II) ion and the inductively coupled plasma (ICP) method that give the total concentration of mercury ions. On the optimized conditions, the calibration curve of mercury (II) ion was linear over the range from $1.25{\times}10^{-5}$ to $2.50{\times}10^{-3}M$ with correlation coefficient of 0.991. The detection limit of mercury (II) ion in aqueous solution was calculated to be $1.25{\times}10^{-7}M$.

The Influence of Butyl Alcohol on the Distribution Coefficients of Metal Ions (금속이온의 분포계수에 미치는 부틸알코올의 영향)

  • Dong Won Kim
    • Journal of the Korean Chemical Society
    • /
    • v.25 no.1
    • /
    • pp.21-25
    • /
    • 1981
  • A study was made of the influence of butyl alcohol on the distribution coefficients of barium and mercury ions between the ion exchange resin, Dowex 50w-x8, 200~400 mesh and solutions containing hydrochloric acid, butyl alcohol and water. The determination of the distribution coefficients of barium and mercury are made by using the batch method. The distribution coefficients of metal ions decrease generally as the number of branches of carbon in the molecule of butyl alcohol increase. It shows that solubility in water and stereo-isomerism of the butyl alcohol have influence upon the distribution coefficient of barium and mercury.

  • PDF

Studies on the Metal-Exchange Reaction of Tetrahedral Cu(II) Complex with Mercuric Ion and Mercury Metal (정사면체 구조를 갖는 Cu(II) 착물과 수은(II) 및 수은(0)과의 금속 교환반응 연구)

  • Young Tae Gong;Sung Nak Choi;Yoon-Bo Shim
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.2
    • /
    • pp.223-229
    • /
    • 1992
  • Mechanistic studies on the metal-exchange reactions of sparteine copper(II) dichloride [$SpCuCl_2$] with Hg(II) ion and Hg(0) metal have been carried out with the aid of Cyclic Voltammetry and UV-visible spectrophotometry. The metal exchange reaction of $SpCuCl_2$ with both Hg(II) ion and Hg(0) metal follows pseudo-first order kinetics. Rate constants and activation parameters of metal exchange reaction have been evaluated and reported. Experimental results indicate that the rate determining step for the exchange reaction is the cleavage of Cu(II)-N bond in the transient binuclear complex of Cu(II) and mercury(II) bound to sparteine ligand.

  • PDF

A Study on the Development of Electrolysis System with Vertically Circulating Mercury Capillary Bundle Electrode and its Characteristics (수직형 순환식 수은 모세관 다발체 전극 전해계의 개발과 그 특성 연구)

  • Kim, Kwang-Wook;Lee, Eil-Hee;Shin, Young-Joon;Yoo, Jae-Hyung;Park, Hyun-Soo
    • Applied Chemistry for Engineering
    • /
    • v.7 no.2
    • /
    • pp.228-236
    • /
    • 1996
  • An electrolysis system with a vertically circulating mercury capillary bundle electrode was developed with a very large electrode area in a minimum space. This system was operated by forcedly feeding mercury and aqueous solution containing metal ion into a fiber bundle packed densely within a small porous glass tube. In order to test the characteristics and stability of the electrolysis system, the reduction voltammograms of uranyl and ferric ions were measured with changes of the mercury flow rate and the aqueous flow rate. The aqueous flow rate had a large effect on the electrochemical reaction of metal ion occurring at the interface between the mercury and the aqueous solution and had to be regulated as an appropriate value to have a good limiting current shape. The limiting current was linearly proportional to the aqueous flow rate, and complete reductions of uranyl and ferric ions were rapidly and continuously accomplished at the potential showing limiting current. With a mercury flow rate high enough to keep a capillary continuum of mercury in the fiber bundle, the mercury flow rate had almost no effect on the electrochemical reaction. This system was confirmed to be effective and stable enough to control rapidly and continuously the oxidation state of metal ions fed into the system under an appropriate aqueous flow rate.

  • PDF

Influence of Mercury on the Repair of Ionizing Radiation-induced DNA Damage in Coelomocytes of Eisenia fetida (이온화 방사선에 의해 손상된 Eisenia fetida 체강세포의 DNA 수복에 수은이 미치는 영향)

  • Ryu, Tae-Ho;Nili, Mohammad;An, Kwang-Guk;Kim, Jin-Kyu
    • Korean Journal of Environmental Biology
    • /
    • v.29 no.3
    • /
    • pp.236-240
    • /
    • 2011
  • Mercury known as quicksilver, is the most common cause of heavy metal toxicity. Toxicity caused by excessive mercury exposure is now being recognized as a widespread environmental problem and is continuing to attract a great deal of public concerns. The mercury genotoxicity could be its effect on DNA repair mechanisms, which constitute the defense system designated to protect genome integrity. The objective of this study is to confirm that mercuric chloride inhibits the repair of gamma ray-induced DNA damage. The earthworm of Eisenia fetida was chosen for this study because it is an internationally accepted model species for toxicity testing with a cosmopolitan distribution. Experiments were done to identify the levels of DNA damage and the repair kinetics in the coelomocytes of E. fetida irradiated with 20 Gy gamma rays alone or with gamma rays after 40 mg $kg^{-1}$ $HgCl_2$ treatment by means of the single cell gel electrophoresis assay. The Olive tail moments were measured during 0~96 hours after irradiation. The repair time in the animals treated with the combination of $HgCl_2$ and ionizing radiation was nearly five times longer than that in the animals treated with ionizing radiation alone. Also, E. fetida exposed to mercury showed a statistically lower repair efficiency of gamma ray-induced DNA damage. The results suggest that the mercury could even have deleterious effects on the DNA repair system. Influence of mercury on the DNA repair mechanisms has been confirmed by this study.

Laser Intensity Dependence in Resonant Multiphoton Ionization of Hg Atoms (수은 원자에서의 공명 다광자 이온화 과정의 레이저 강도 의존성)

  • 한재민;정도영;차형기;김철중;이종민
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.7-11
    • /
    • 1990
  • Resonant multi photon ionization (RMPD of Hg atoms is studied by focusing a high-power laser into the ionization cell. The intermediate resonant state is taken as $6d^1D_2$ with the 4-photon resonance wavelength of 560.7 nm. The ionization signal is measured as Hg vapor pressure (0.1-3.0 Torr), laser intensity $(10-120GW/\textrm{cm}^2)$, and laser wavelength (559-569 nm) vary. AC Stark shift and line broadening of the resonant state $(6d^1D_2)$ are observed and the shift factor is measured to be $-0.6(cm^{-1}/GW/\textrm{cm}^2$. It is also observed that the ionization signal increases as the Hg vapor pressure increases up to a certain value of pressure, however, if the pressure further increases, the signal decreases. The order of non-linearity, which discribes the laser intensity dependence of ionization rate, is measured to be 3 at the resonance, and compared with the theoretical results.esults.

  • PDF

Effect of Salviae Radix on renal tubular reabsorption in rabbits with mercury-induced acute renal failure (수은으로 유발된 토끼의 신장 기능 손상에 대한 단삼(丹參)의 효과)

  • Hwang, Young-Geun;Jeong, Ji-Cheon
    • The Journal of Internal Korean Medicine
    • /
    • v.21 no.2
    • /
    • pp.227-234
    • /
    • 2000
  • 독성약물에 의한 급성신부전시 세뇨관세포의 물질 재흡수 장애에 대한 단삼(丹參) 추출액의 효과를 조사하였다. 토끼에 수은(HgCl2)을 10 mg/kg되게 피하 주사하여 급성신부전을 유발하였고, 단삼(丹參) 추출액의 효과는 수은을 주사하기 전 7일 동안 0.05% 액(液) 0.3 g/kg 용량을 경구 투여하여 관찰하였다. 수은을 주사하기 전 24시간 동안 요와 혈액을 채취하여 신장기능을 측정하여 대조기간(basal period)의 값으로 하였고, 수은을 주사한 후 24시간 동안 요와 혈액을 얻어 수은에 의한 신장기능 변화를 평가하였다. 수은을 처리한 후 사구체여과율이 대조값에 비해 감소하였고, 혈청내 creatinine 농도가 증가하였다. 이러한 결과들은 수은이 급성신부전을 유발하였음을 가리킨다. 수은을 처리한 동물에서 포도당 및 인산의 배설분율이 증가하였고, 이러한 변화는 brush-border membrane에서 물질의 이동장애와 Na-pump 활성의 감소에 기인하였다. 수은을 주사한 동물의 신장피질 절편에서 유기이온인 PAH와 TEA 이동이 억제되었다. 토끼의 신장조직에서 지질의 과산화가 수은을 주사한 후 증가하였다. 단삼(丹參) 추출액을 전 처리한 후 수은을 주사한 경우 수은에 의해 유발된 사구체여과율의 감소와 혈청내 creatinine 농도 증가 현상이 유의하게 완화되었다. 수은에 의한 세뇨관에서 물질의 재흡수 장애가 단삼(丹參) 추출액의 전처리에 의해 방지되었다. 단삼(丹參) 추출액은 수은에 의한 지질의 과산화를 억제하였다. 수은에 의한 급성신부전은 항산화제로 잘 알려진 DPPD에 의해 방지되었다. 이상의 결과를 종합하면 생체실험결과 수은에 의한 급성신부전의 유발과정에 지질의 과산화가 중요한 역할을 할 가능성을 보이고 있고, 단삼(丹參) 추출액은 수은에 의한 급성신부전을 방지하는 효과를 가지고 있으며, 그 효과는 단삼(丹參)의 항산화작용에 기인(起因)할 가능성이 많다.

  • PDF