• Title/Summary/Keyword: 수용인원

Search Result 66, Processing Time 0.021 seconds

A Study on Civil Defense Evacuation Facilities (전국의 대피시설 실태조사를 통한 민방위 대피시설 표준 정립 모델 구축 연구)

  • Park, Namhee;Yeo, Wookhyun;Kim, Taewhan
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.1
    • /
    • pp.56-70
    • /
    • 2012
  • Civil defense evacuation facilities currently installed in our country are necessary to survey the operating status. The purpose of this study is to survey on the current facility for civil defense evacuation facilities equipment, management, and problem analysis, research and to build a facility model of the standard formulation through the analysis on the actual condition of the civil defense evacuation facility. The conclusions of this study are as follows. First, the civil defense evacuation facilities are most in Seoul. Second, civil defense evacuation facilities proved to be checked periodically without a systematic management. Many facilities do not have communication facilities appear to be evacuated in an emergency situation is expected to have difficulty in contact with the outside world. Fourth, the old civil defense evacuation facilities are in the center of the metropolitan area.

An Analysis on the Appropriation of Chemical Accident Evacuation Facility Using GIS - focused on Ulsan metropolitan city - (GIS 기법을 활용한 화학사고 대피시설의 적정성 분석 - 울산광역시를 대상으로 -)

  • SONG, Bong-Geun;LEE, Tae-Wook;KIM, Hyun-Ju;KIM, Tai-Hoon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.1
    • /
    • pp.71-82
    • /
    • 2018
  • The purpose of this study is to minimize damage of chemical accidents through the appropriation analysis of evacuation facility position focused on Ulsan metropolitan city. For analysis, informations such as pollutant release and transfer registers(PRTR), population census, and evacuation facilities were used. After then, damage assessment of chemical accidents, accessibility and appropriation of evacuation facilities were analyzed. Damage of chemical accidents is high in around 5km of industrial complex there is dense of chemical facility and population. Evacuation facilities were mainly situated in hazard area of chemical accidents, but accessibility of evacuation facilities was vulnerable in chemical plant neighborhood. Therefore, safety check of deteriorated plants is important for prevention of chemical accidents. Also, effective evacuation plan considering capacity and scale of evacuation facilities will be established.

A study on the Comparison of High-rise building Egress Safety Rule in Countries for improvement of High-rise evacuation safety design criteria (초고층 피난안전설계 기준 개선을 위한 국내외 피난관계법령 비교에 관한 연구)

  • Hwang, EunKyung;Park, SuRoh
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.429-438
    • /
    • 2013
  • In this study, compare and analyze for high-rise evacuation safety design criteria improvement about internal high-rise building egress safety rule. To the result, high-rise evacuation safety design criteria improvement data can be summarized as follows. First, should compute the evacuation capacity about the number of persons and when more than 2 exits are requested, over 50% of evacuation capacity must be satisfied even approaching to 1 exit is unable. Second, 2 ways of evacuation can be made smoothly by the stair or exit separation-distance standard regulation. Third, regulate the length limitation of dead-end corridor or passageway and it should give grades in limitation of whether the spring-cooler has been installed. Fourth, must secure the evacuation way and do the evacuee guidance when it's safety area and elevator or stair. Also needs to provide extra safety area to secure horizontal direction Escape Safety except fire escaping floor.

Analysis of Temporary Housing for the Displaced People in Rural Area Emergencies (농촌지역 이재민 임시주거시설 지정 현황 및 개선 방안)

  • Lim, Changsu;Lee, Seung-chul;Kim, Eun-Ja;Park, Mi-Jung
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.413-421
    • /
    • 2017
  • This study intends to conduct a thorough research and analysis on the designated temporary residential facilities for the disaster victims in order to bridge the gap between the temporary residential facilities for the disaster victims in country and city, and understand the current status of the designated temporary residential facilities for the disaster victims in rural and urban areas. As a result, the designated temporary residential facilities for the disaster victims in urban areas are bigger and have higher capacity, implying the necessity to designate facilities in rural areas that can accommodate larger number of people. As to the analysis of the representative temporary residential facilities for the disaster victims in rural areas, different regions had different types of designated facilities and the number of facilities also showed big difference depending on regions. So it is believed that local governments should improve the process and system of designating temporary residential facilities for the disaster victims.

The Legal Problems and Improvement in the Performance Based Design of Fire-fighting (성능위주소방설계의 법적문제 및 개선방안)

  • Yi, Jong-Yeong;Baek, Ok-Sun
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.54-63
    • /
    • 2010
  • The buildings relevant to the law should be designed performance-based necessarily according to "Fire-Fighting System Installation Business Act" amended, January 1. 2009. Performance based design means that building design reflects structure, size, purpose, and building capacity to achieve the most effective design of fire-fighting system. Performance based design has meaning to buildings that it is insufficient to control fire-fighting by previous law-oriented design or inappropriate by uniform design, because of buildings becoming bigger and higher. However, it is difficult to implement the system actually, because laws relevant to fire-fighting prescribe only the object and the required qualifications of performance based design, but they don't have rules to enforce performance based design for specific parts. This study suggests improvements for a desirable implementation of performance based design in legal aspects, by analyzing the current legal regulations related to performance based design.

A Study of Public Library Makerspace Operations (공공도서관 메이커스페이스 운영 현황 조사 연구)

  • Chang, Yunkeum;Kim, Sehun;Jeon, Kyungsun
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.53 no.3
    • /
    • pp.161-183
    • /
    • 2019
  • This study explores the development strategies, impact, and limitations of public library makerspaces through active case studies. By examining related literature reviews, this study analyzes principles, objectives, programs, services, and strategies of public library makerspaces. Survey results from library staff and makerspace program participants show that both groups perceived the value and the effects of makerspaces positively; however, they suggested the need for greater program variety and accessibility. Additionally, this study evaluates makerspace programs through in-depth interviews with makerspace staff. Interview results raise diverse issues, including the need to further explore the justifications for and values of public library makerspaces, stable funding strategies, and phase-by-phase operating guidelines.

Investigating factors influencing the usage of Korea Immigration Smart Service (공항이용객의 자동출입국심사 시스템 사용의도에 관한 연구)

  • Choi, Jin-Ho;Park, Jin-Woo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.277-278
    • /
    • 2011
  • Traditionally airport users have presented their passport themselves to immigration for entering and leaving countries. To improve the inefficiency of this traditional immigration system, Incheon International Airport (IIA) has introduced automatic immigration system called Korea Immigration Smart Service (KISS). This research investigates airport users' behavioral intentions of KISS. To achieve the research purpose, the conceptual model is developed on the basis of the technology acceptance model. The result from this research can be used for improvement of KISS system.

  • PDF

A Study on the Diagnosis and Improvement of the Road Work Zone (도로점용공사장 교통관리방안의 문제점 및 개선방안 (서울시를 중심으로))

  • 김종민;이상용
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.5
    • /
    • pp.119-133
    • /
    • 2003
  • 도로는 교통기능 외에 여러 시설물을 수용할 수 있는 사회 인프라구축의 공간으로 활용될 수 있기 때문에 서울시뿐만 아니라 각 지방자치단체에서는 이러한 공간을 활용하기 위한 도로점용공사는 매년 전국적으로 수만 건에 달하고 있다. 따라서. 매년 발생하는 도로점용공사의 차로과다 점용, 교통시설물 설치 부적절, 보행자 안전무시, 공사안내표지 부적절, 공사구간에서의 불법 주.정차 등의 문제점이 계속하여 발생.지적되고 있으나 이에 따른 관련 규정이 미흡하여 도로점용공사 시행자의 불법을 초래하고 있는 실정이다. 또한 서울시의 경우 시스템적 접근방법인 관련조례에 의해서 수행되기보다는, 교통자문회의로 운영되고 있으며, 관련 인원 및 법적 제재조치가 미약하여 도로점용공사의 효과적인 관리가 어려운 실정이다. 따라서 서울시 및 각 지방자치단체에서는 도로점용공사로 인한 보행자와 운전자의 통행권 확보와 안전상의 문제 등을 하루빨리 인식하여 도로점용공사에 따른 도로공사장 교통관리 규정을 법규화 하여 체계적으로 관리할 필요가 있다. 이에 따라, 본 논문에서는 도로점용공사에 따른 관련법 및 적용대상, 관련보고서 검토, 서울시를 사례로 한 공사중 교통처리방안 운영실태 및 문제점의 진단을 통하여 향후 도로공사장 교통관리 규정의 운영적 및 제도적 측면의 개선방안과 향후 추진방향을 제시하고자 한다.

A Study on Risk Assessment for Fire Onboard a Naval Vessel (해군함정 화재 위험도 평가에 관한 연구)

  • Jeon, Gae-Ryong;Kim, Dong-Jin
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.35-42
    • /
    • 2008
  • With the huge navy projects such KDX-III, LPX, bigger and more complicated vessel constructions are being underway in navy. In this paper, considering these trends, we performed a risk analysis on the navy vessel for the fatality of soldiers on board and presented the risk level with FN curve. Assuming a fire occurs in one of the soldier bedrooms, we established event tree to visualize the possible development scenarios and calculated the fatality for each scenario. The critical condition to survive inside the bedroom was obtained through CFAST program.

Numerical Analysis of Smoke Control for high-rise Building Considering with the Enthalpy Equation (Enthalpy Equation을 이용한 고층 건물의 제연해석)

  • Bae, Sung-Ryong;Ro, Kyoung-Chul;Ko, Gwon-Hyun;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.27-32
    • /
    • 2010
  • Recently, increases of population density due to the industrialization in the metropolitan cities has caused the high-density and integration of life environment. Then various high-rise buildings are constructed for accommodation. However, high-rise building fires can cause high casualties due to increases of smoke spread velocity through the vertical shaft. In this study, the new program based on the enthalpy conservation for analysis of energy transfer for smoke control system, CAU_ESCAP, was developed. CAU_ESCAP was validated by comparing with the result of ASCOS. The characteristic of smoke control was analysed by using CAU_ESCAP for high-rise building fires.