• Title/Summary/Keyword: 수술 전 정보제공

Search Result 40, Processing Time 0.031 seconds

Evaluation of the Fetal Dose during Prophylactic Placement of Internal Iliac Artery Balloon Occlusion Catheters in Placenta Accreta (유착태반환자의 예방적 내장골동맥 풍선카테터 설치술 시행 시 태아선량 평가)

  • Kim, Dong-Sik;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.313-321
    • /
    • 2016
  • Placenta accrete patients whose mother mortality rates are rather high due to massive bleeding during childbirth need to have Prophylactic placement of Internal Iliac Artery Balloon Occlusion Catheters procedure to reduce amount of blood loss and inoperative transfusion. Nevertheless, studies for mothers inevitably exposed to dose during PIIABOCs procedure have not been published many yet. Therefore, this study is to investigate exact information on radiation dose exposed to fetus during PIIABOCs procedure. Average effective dose of fetus per organ is 2.38~8.83 mGy, measured highest at beam center and followed by eyeball, stomach and bladder. The result showed that the longer fluoroscopy time is used, the closer beam center is and the thicker abdominal thickness is, the more effective dose on fetus is increasing. When using the collimator and protection shown to decrease the effective dose and when using higher the patient table shown to decrease the effective dose. It has been reported that the threshold of deterministic effect is about 100mGy. Deterministic effect was regarded as a factor that would influence on fetus exposed by medical radiation than stochastic effect. Consequently, it concluded that dose exposed on fetus in PIIABOCs procedure was approximately 10% of threshold of deterministic effect with effective dose of 0.49~18.27 mGy.

Comparative Analysis of Countries based on Water Evaluation Indicators (국가별 수자원평가지표 비교 평가)

  • Choi, Si Jung;Lee, Dong Ryul;Kim, Hwi Rin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.839-843
    • /
    • 2004
  • 최근 들어 수자원 계획과 관리에 대한 평가를 위해 수문, 사회, 경제 및 환경 지표들을 이용하여 평가하고자 하는 노력들이 지속되고 있다. 이를 통해 수자원의 여건을 여러 지표들을 통합한 통합지표로 평가함으로서 객관적이고 투명한 결과로 도출하고자 하고 있다. 여러 국제기구 및 연구단체에서는 최근 논의가 되고 있는 지속가능한 발전을 평가하기 위해 각 국가별 자료를 수집하여 지표분석을 통해 각 국가별 상황을 제시하고 있다. 대표적인 통합지표로는 WPI(Water Poverty Index), HDI(Human Development Index)와 ESI(Environmental Sustainability Index) 등이 있으며 이 외에도 OECD, SEI 등과 같은 국제기구들이 여러개별 지표들을 통하여 지속가능성을 평가하고자 하고 있다. 또한 가상의 물 교역(virtual water trade)을 통해 개발된 지표들을 이용하여 각 나라의 수자원 현황을 평가하였다. 본 연구에서는 개발되었던 경제, 사회의 통합지표인 HDI, 환경 통합지표인 ESI, 수자원관련 통합지표인 WPI 등을 소개하고 이를 통해 우리나라의 지속가능성을 평가하여 보았다. 또한 Virtual Water Trade를 통해 국가별 수자원 현황을 평가하였고 여러 개별지표 등을 통해 수자원 뿐만 아니라 경제, 사회, 환경 등 여러분야에 대해 우리나라의 상황을 알아보았다. 이 연구를 통해 정확하게는 분석이 이루어진다고 말할 수는 없지만 정책결정에 도움을 줄 수 있는 정보를 제공하였다고 생각된다. 또한 국내, 외의 여러 지표를 통해 국내 실정에 맞는 우리나라의 수자원을 평가할 수 있는 통합적인 수자원관련 지표 개발에 많은 도움을 주었으리라 사료된다.DEM 자료로 변환하였다. 또한 유역의 고도차를 이용한 흐름특성 분석을 위해 수치고도자료를 이용하여 유역흐름특성을 분석할 수 있는 TOPAZ(Topographic PArameteri-Zation) 프로그램을 이용하였다. TOPAZ 프로그램을 통해 분석된 각 격자별 분포형 수문 매개변수는 적합한 관계식을 통해 분포형 유출량을 모의하는데 적용된다.다 정확한 유입량 예측이 가능할 것으로 사료된다.이 작은 오차를 발생하였으며, 전체적으로 퍼프 모형이 입자모형보다는 훨씬 적은 수의 계산을 통해서도 작은 오차를 나타낼 수 있다는 것을 알 수 있었다. 그러나 Gaussian 분포를 갖는 퍼프모형은 전단흐름에서의 긴 유선형 농도분포를 모의할 수 없었고, 이에 관한 오차는 전단계수가 증가함에 따라 비선형적으로 증가하였다. 향후, 보다 다양한 흐름영역에서 장${\cdot}$단점 분석 및 오차해석을 수행한 후에 각각의 Lagrangian 모형의 장점만을 갖는 모형결합 방법을 제시할 수 있을 것으로 판단된다.mm/$m^{2}$로 감소한 소견을 보였다. 승모판 성형술은 전 승모판엽 탈출증이 있는 두 환아에서 동시에 시행하였다. 수술 후 1년 내 시행한 심초음파에서 모든 환아에서 단지 경등도 이하의 승모판 폐쇄 부전 소견을 보였다. 수술 후 조기 사망은 없었으며, 합병증으로는 유미흉이 한 명에서 있었다. 술 후 10개월째 허혈성 확장성 심근증이 호전되지 않아 Dor 술식을 시행한 후 사망한 예를 제외한 나머지 6명은 특이 증상 없이 정상 생활 중이다 결론: 좌관상동맥 페동맥이상 기시증은 드물기는 하나, 영유아기에 심근경색 및 허혈성 심근증 또는 선천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심

  • PDF

Diagnostic Performance of Rectal CT for Staging Rectal Cancer: Comparison with Rectal MRI and Histopathology (직장암 병기결정에서 직장 CT의 진단능: 직장 MRI 및 병리결과와의 비교분석)

  • Seok Yoon Son;Yun Seok Seo;Jeong Hee Yoon;Bo Yun Hur;Jae Seok Bae;Se Hyung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1290-1308
    • /
    • 2023
  • Purpose To compare the diagnostic performance of rectal CT with that of high-resolution rectal MRI and histopathology in assessing rectal cancer. Materials and Methods Sixty-seven patients with rectal cancer who underwent rectal CT with rectal distension using sonographic gel and high-resolution MRI were enrolled in this study. The distance from the anal verge/anorectal junction, distance to the mesorectal fascia (MRF), extramural depth (EMD), extramesorectal lymph node (LN) involvement, extramural venous invasion (EMVI), and T/N stages in rectal CT/MRI were analyzed by two gastrointestinal radiologists. The CT findings of 20 patients who underwent radical surgery without concurrent chemoradiotherapy were compared using histopathology. Interclass correlations and kappa statistics were used. Results The distance from the anal verge/anorectal junction showed an excellent intraclass correlation between CT and MRI for both reviewers. For EMD, the distance to the MRF, presence of LNs, extramesorectal LN metastasis, EMVI, T stage, and intermodality kappa or weighted kappa values between CT and MRI showed excellent agreement. Among the 20 patients who underwent radical surgery, T staging, circumferential resection margin involvement, EMVI, and LN metastasis on rectal CT showed acceptable concordance rates with histopathology. Conclusion Dedicated rectal CT may be on par with rectal MRI in providing critical information to patients with rectal cancer.

A Study of the Pattern of Skeletal Metastases and Renal Uptakes on Bone Scan in Renal Cell Carcinoma (골스캔상 신세포암의 골전이 양상과 신장섭취 형태에 관한 연구)

  • Chun, Hae-Kyung;Yang, Seoung-Oh;Shin, Joung-Woo;Won, Kyoung-Sook;Choi, Yun-Young;Ryu, Jin-Sook;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.524-531
    • /
    • 1996
  • Purpose : To evaluate the pattern- of skeletal metastases and to classify the pattern of renal uptakes on bone scans in renal cell carcinoma. Materials and Methods : We reviewed the bone scans of 158 patients with RCC established pathologically. In order to identify individual scan lesion as a bone metastasis, we reviewed all available correlative radiological studies, follow-up bone scans, and biopsies for each lesion. The metastatic bone lesions were divided into seven anatomic regions; skull, spine, shoulder girdle, sternum, ribs, pelvis, and long bones of extremities. The individual scan lesions were divided into two groups as the pattern of uptakes, hot and cold lesion. In addition, the contours and uptakes of kidneys with RCC were classified into 6 groups ; normal uptake, photon-deficient lesion, faint up-take with enlargement, uneven uptake with enlargement, lateralization with crescentic shape, and increased uptake. Results : Twenty out of 158(12.7%) patients with RCC at varying stages showed 71 metastatic bone lesions at presentation and on follow- up bone scans. Nearly 80% of all metastatic lesions were in the axial skeleton with predominantly increased uptake of the radioactivity However a considerable number(22.5%) showed cold lesions on bone scan. A half of bone scans revealed abnormal uptake of involved kidney and much more(82.4%) in case of bone metastases. Two common patterns of abnormal renal uptake were photon-deficient lesion (50%) and faint uptake with enlargement(24.3%). In four patients with bone pain or pathologic fracture, bone scans were useful for the serendipitious localization of previously unrecognized primary lesion of RCC as well as for the detection of bone metastases from RCC. Conclusion : The understanding of the pat-terns of skeletal metastases and renal uptakes on bone scans in RCC is important for the useful information about primary lesion(RCC) as well as detection of bone metastases.

  • PDF

Usefulness of Breast Lymphoscintigraphy after Whole Body Bone Scan (유방암 환자에서 전신 뼈 검사 후 감시림프절 위치 파악 검사의 유용성)

  • Jang, Dong-Gun;Bahn, Young-Kag;Chung, Seok;Park, Hoon-Hee;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.133-137
    • /
    • 2010
  • Purpose: Breast cancer is known to be more vulnerable to bone metastasis and lymph node metastasis than other types of cancer, and nuclear examinations whole body bone scan and lymphoscintigraphy are performed commonly before and after breast cancer operation. In case whole body bone scan is performed on the day before lymphoscintigraphy, the radiopharmaceutical taken into and remaining in the bones provides anatomical information for tracking and locating sentinel lymph nodes. Thus, this study purposed to examine how much bone density affects in locating sentinel lymph nodes. Materials and Methods: The subjects of this study were 22 patients (average age $52{\pm}7.2$) who had whole body bone scan and lymphoscintigraphy over two days in our hospital during the period from January to December, 2009. In the blind test, 22 patients (average age $57{\pm}6.5$) who had lymphoscintigraphy using $^{57}Co$ flood phantom were used as a control group. In quantitative analysis, the relative ratio of the background to sentinel lymph nodes was measured by drawing ROIs on sentinel lymph nodes and the background, and in gross examination, each of a nuclear physician and a radiological technologist with five years' or longer field experience examined images through blind test in a five-point scale. Results: In the results of quantitative analysis, the relative ratio of the background to sentinel lymph nodes was 14.2:1 maximum and 8.5:1 ($SD{\pm}3.48$) on the average on the front, and 14.7:1 maximum and 8.5:1 ($SD{\pm}3.42$) on the average on the side. In the results of gross examination, when $^{57}Co$ flood phantom images were compared with images containing bones, the score was relative high as 3.86 ($SD{\pm}0.35$) point for $^{57}Co$ flood phantom images and 4.09 ($SD{\pm}0.42$) for bone images. Conclusion: When whole body bone scan was performed on the day before lymphoscintigraphy, the ratio of the background to sentinel lymph nodes was over 10:1, so there was no problem in locating lymph nodes. In addition, we expect to reduce examination procedures and improve the quality of images by indicating the location of sentinel lymph nodes using bone images as body contour without the use of a source.

  • PDF

Three-Dimensional Brain Surface Rendering Imaging of Cortical Dysplasia (뇌피질 이형성증의 3차원 뇌표면 연출영상)

  • Hwang, Seung-Bae;Kwak, Hyo-Sung;Lee, Sang-Yong;Jin, Gong-Yong;Han, Young-Min;Chung, Gyung-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.2
    • /
    • pp.126-133
    • /
    • 2010
  • Purpose : The study was to evaluate the localization of the abnormal gyral and sulcal patterns obtained by means of brain surface rendering imaging. Materials and Methods : Nineteen patients with cortical dysplasia who underwent brain surface rendering MR imaging were included in this study. We acquired MP-RAGE sequence and created the 3-D surface rendering MR images by using $VoxelPlus^{(R)}$. Anatomical locations and configurations of abnormal gyri and sulci were reviewed. Results : Abnormal gyral and sulcal patterns were seen 18 in 19 patients. The configuration and orientation of affected gyri and sulci were clearly evaluated in the brain surface rendering images. In a lissencephaly, the a cortex was not delineated and showed markedly thick and smooth gyral pattern. In a schizencephaly, there were wheel shaped broad gyral pattern around the cleft. In a hemimegalencephaly, an affected hemisphere were enlarged and displayed thick and wide gyral pattern. In CBPS, the insular cortex was exposed and the gyri of the lesion were thickened. In focal cortical dysplasia, there were irregular serrated or thick and enlarged gyri. Conclusion : Brain surface rendering MR imaging is useful for the evaluation of a detailed gyral pattern and accurate involvement site of abnormal gyri.

Analysis of the artifact reduction rate for the types of medical metals in CT with MAR algorithm (CT의 MAR알고리즘 적용 시 의료용 금속 물질별 인공물 감소율 분석)

  • Kim, Hyeon-ju;Yoon, Joon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.655-662
    • /
    • 2016
  • We investigated on the usefulness of MAR algorithm by making a comparison of the CT value between before and after applying the MAR algorithm in dual energy CT, using the various kinds of medical metals, causing the artifact to lead to the low image quality. As a result, the artifact was reduced in most cases (P<0.05); in particular, the artifact was highly reduced (P<0.05) using high density material, like alloy-stainless (reduced by 78.1%) and platinum, for example GDC coil (reduced by 76.1%). The effect of decreasing the Black hole artifact was outstanding in both the alloy-stainless and alloy-titanium (P<0.05). However, in case of GDC coil-a type platinum, white streak artifact was reduced effectively (P<0.05). Therefore, in case of patients who have medical metals inserted, we think that high-quality image information can be provided by decreasing the artifact caused by high density material through MAR algorithm in dual energy CT.

Thromboelastographic Analysis of the Coagulation System During Cardiopulmonary Bypass -Analysis of the Effect of Low-Dose Aprotinin (심폐바이패스시 혈액응고체계 변화의 혈전탄성검사 분석 - 단일 저용량 아프로티닌 투여 효과 분석 -)

  • 김관민;박계현
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.677-685
    • /
    • 1997
  • Thromboelastography(TEG) is the unique measure that gives rapid information about the whole clotting process. Simplifying the diagnosis of coagulopathy during operations, TEG can provide an adequate therapy for postoperative bleeding. Remarkable improvement in hemostasis after cardiopulmonary bypass(CPB) has been achieved by the treatment with proteinase inhibitor aprotinin, but the hemostatic mechanism of aprotinin during CPB is still unclear. This study was designed to evaluate the effects of aprotinin on coagulation system during CPB by using TEG. Forty patients who underwent CPB were divided into two groups: aprotinin(2u 106 kallikrein inhibition units, as a single dose into the cardiopulmonary bypass priming solution) treatment group(male 14, female 8, mean age=50.Byears) and no aprotinin treatment(control) group(male 10, female 8, mean age=53.4 years). TEG, activated clotting time, prothrombin time, activated partial thromboplastin time, platelet counts, fibrinogen an (ibrinogen degradation product(FDP) concentrations were checked before and after CPB(30 minutes after neutralization of heparin effect by protamine sulfate). There was no significant difference in other conventional coagulation tests of two groups except postcardiopulmonary bypass FDP concentration in control group, which was significantly increased compared to that in aprotinin group(p<0.05). In TEG variables of both groups, clot formation time(K) and alpha $angle(\alpha^{\circ})$ were significantly increased and decreased, respectively, after CPB(p<0.05), but fibrinolytic index(LYS60) was not changed during CPB. In aprotinin group, reaction time(R) was decreased significantly after CPB(p<0.05) but maximum amplitude(MA) was not changed(p>0.05). On the contrary, R was not changed markedly but MA was decreased significantly in control group after CPB(p<0.05). This result shows that main change in coagulation system during CPB is not hyperfibrinolysis but cecrease in clot strength by platelet dys unction, and the main effect of aprotinin during cardiopulmonary bypass is the maintenance of clot strength to the pre-CPB level by the preservation of platelet function.

  • PDF

The comparison of lesion localization methods in breast lymphoscintigraphy (Breast lymphoscintigraphy 검사 시 체표윤곽을 나타내는 방법의 비교)

  • Yeon, Joon ho;Hong, Gun chul;Kim, Soo yung;Choi, Sung wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.74-80
    • /
    • 2015
  • Purpose Breast lymphoscintigraphy is an important technique to present for body surface precisely, which shows a lymph node metastasis of malignant tumors at an early stage and is performed before and after surgery in patients with breast cancer. In this study, we evaluated several methods of body outline imaging to present exact location of lesions, as well as compared respective exposure doses. Materials and Methods RANDO phantom and SYMBIA T-16 were used for obtaining imaging. A lesion and an injection site were created by inserting a point source of 0.11 MBq on the axillary sentinel lymph node and 37 MBq on the right breast, respectively. The first method for acquiring the image was used by drawing the body surface of phantom for 30 sec using $Na^{99m}TcO_4$ as a point source. The second, the image was acquired with $^{57}Co$ flood source for 30 seconds on the rear side and the left side of the phantom, the image as the third method was obtained using a syringe filled with 37 MBq of $Na^{99m}TcO_4$ in 10 ml of saline, and as the fourth, we used a photon energy and scatter energy of $^{99m}Tc$ emitting from phantom without any addition radiation exposure. Finally, the image was fused the scout image and the basal image of SPECT/CT using MATLAB$^{(R)}$ program. Anterior and lateral images were acquired for 3 min, and radiation exposure was measured by the personal exposure dosimeter. We conducted preference of 10 images from nuclear medicine doctors by the survey. Results TBR values of anterior and right image in the first to fifth method were 334.9 and 117.2 ($1^{st}$), 266.1 and 124.4 ($2^{nd}$), 117.4 and 99.6 ($3^{rd}$), 3.2 and 7.6 ($4^{th}$), and 565.6 and 141.8 ($5^{th}$). And also exposure doses of these method were 2, 2, 2, 0, and $30{\mu}Sv$, respectively. Among five methods, the fifth method showed the highest TBR value as well as exposure dose, where as the fourth method showed the lowest TBR value and exposure dose. As a result, the last method ($5^{th}$) is the best method and the fourth method is the worst method in this study. Conclusion Scout method of SPECT/CT can be useful that provides the best values of TBR and the best score of survey result. Even though personal exposure dose when patients take scout of SPECT/CT was higher than another scan, it was slight level comparison to 1 mSv as the dose limit to non-radiation workers. If the scout is possible to less than 80 kV, exposure dose can be reduced, and also useful lesion localization provided.

  • PDF

Assessment of Bone Metastasis using Nuclear Medicine Imaging in Breast Cancer : Comparison between PET/CT and Bone Scan (유방암 환자에서 골전이에 대한 핵의학적 평가)

  • Cho, Dae-Hyoun;Ahn, Byeong-Cheol;Kang, Sung-Min;Seo, Ji-Hyoung;Bae, Jin-Ho;Lee, Sang-Woo;Jeong, Jin-Hyang;Yoo, Jeong-Soo;Park, Ho-Young;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.30-41
    • /
    • 2007
  • Purpose: Bone metastasis in breast cancer patients are usually assessed by conventional Tc-99m methylene diphosphonate whole-body bone scan, which has a high sensitivity but a poor specificity. However, positron emission tomography with $^{18}F-2-deoxyglucose$ (FDG-PET) can offer superior spatial resolution and improved specificity. FDG-PET/CT can offer more information to assess bone metastasis than PET alone, by giving a anatomical information of non-enhanced CT image. We attempted to evaluate the usefulness of FDG-PET/CT for detecting bone metastasis in breast cancer and to compare FDG-PET/CT results with bone scan findings. Materials and Methods: The study group comprised 157 women patients (range: $28{\sim}78$ years old, $mean{\pm}SD=49.5{\pm}8.5$) with biopsy-proven breast cancer who underwent bone scan and FDG-PET/CT within 1 week interval. The final diagnosis of bone metastasis was established by histopathological findings, radiological correlation, or clinical follow-up. Bone scan was acquired over 4 hours after administration of 740 MBq Tc-99m MDP. Bone scan image was interpreted as normal, low, intermediate or high probability for osseous metastasis. FDG PET/CT was performed after 6 hours fasting. 370 MBq F-18 FDG was administered intravenously 1 hour before imaging. PET data was obtained by 3D mode and CT data, used as transmission correction database, was acquired during shallow respiration. PET images were evaluated by visual interpretation, and quantification of FDG accumulation in bone lesion was performed by maximal SUV(SUVmax) and relative SUV(SUVrel). Results: Six patients(4.4%) showed metastatic bone lesions. Four(66.6%) of 6 patients with osseous metastasis was detected by bone scan and all 6 patients(100%) were detected by PET/CT. A total of 135 bone lesions found on either FDG-PET or bone scan were consist of 108 osseous metastatic lesion and 27 benign bone lesions. Osseous metastatic lesion had higher SUVmax and SUVrel compared to benign bone lesion($4.79{\pm}3.32$ vs $1.45{\pm}0.44$, p=0.000, $3.08{\pm}2.85$ vs $0.30{\pm}0.43$, p=0.000). Among 108 osseous metastatic lesions, 76 lesions showed as abnormal uptake on bone scan, and 76 lesions also showed as increased FDG uptake on PET/CT scan. There was good agreement between FDG uptake and abnormal bone scan finding (Kendall tau-b : 0.689, p=0.000). Lesion showed increased bone tracer uptake had higher SUVmax and SUVrel compared to lesion showed no abnormal bone scan finding ($6.03{\pm}3.12$ vs $1.09{\pm}1.49$, p=0.000, $4.76{\pm}3.31$ vs $1.29{\pm}0.92$, p=0.000). The order of frequency of osseous metastatic site was vertebra, pelvis, rib, skull, sternum, scapula, femur, clavicle, and humerus. Metastatic lesion on skull had highest SUVmax and metastatic lesion on rib had highest SUVrel. Osteosclerotic metastatic lesion had lowest SUVmax and SUVrel. Conclusion: These results suggest that FDG-PET/CT is more sensitive to detect breast cancer patients with osseous metastasis. CT scan must be reviewed cautiously skeleton with bone window, because osteosclerotic metastatic lesion did not showed abnormal FDG accumulation frequently.