• Title/Summary/Keyword: 수소이온 농도

Search Result 399, Processing Time 0.04 seconds

Active Transport Characteristics of K+-Na+ Pumping System in Cell Membrane Model which Irradiated by High Energy X-ray (고에너지 엑스선을 조사한 세포막모델에서 K+-Na+ 펌프 시스템의 능동적 전달 특성)

  • Ko, In-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.157-165
    • /
    • 2017
  • The active transport characteristics of $K^+$ and $Na^+$ pumping system of cell membrane model which irradiated by high energy x-ray(linac 6MeV) was investigated. The cell membrane model used in this experiment was a $Na^+$ type sulfonated copolymerized membrane of styrene and divinylbenezene. The initial flux of the ion was increased with increase of both $H^+$ ion concentration. In this experiment range(pH 1.5-5, temperature $36.5^{\circ}C$), the initial flux of $K^+$ which was not irradiated by radiation was found to be from $2.09{\times}10^{-4}$ to $1.32{\times}10^{-3}mole/cm^2{\cdot}h$ and that of $Na^+$ from $7.09{\times}10^{-4}$ to $1.09{\times}10^{-3}mole/cm^2{\cdot}h$. the initial flux of $K^+$ which was irradiated by radiation was found to be from $21.0{\times}10^{-4}$ to $16.7{\times}10^{-3}mole/cm^2{\cdot}h$ and that of $Na^+$ from $62.0{\times}10^{-4}$ to $20.6{\times}10^{-3}mole/cm^2{\cdot}h$. The ratio $K^+$/$Na^+$ of membrane was about 1.10. And the driving force of pH of irradiated membrane was significantly increased about 9-20 times than membrane which was not irradiated. As active transport of $K^+$ and $Na^+$ of cell membrane model were abnormal, cell damages were appeared at cell.

Effect on active transport of cell membrane model which irradiated by radiation (방사선이 조사된 세포막 모델이 물질의 능동수송에 미치는 영향)

  • Ko, In-Ho;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.103-110
    • /
    • 2011
  • The effect on active transport of $K^+$ and $Na^+$ of cell membrane model which irradiated by radiation was investigated. The cell membrane model used in this experiment was a $Na^+$ type sulfonated copolymerized membrane of styrene and divinylbenezene. The initial flux of the ion was increased with increase of both $H^+$ ion concentration. In this experiment range(pH $0.5^{-3}$), the initial flux of $K^+$ which was not irradiated by radiation was found to be from $7.9{\times}10^{-4}$ to $7.49{\times}10^{-3}mole/cm^2{\cdot}h$ and that of Na+ from $10.6{\times}10^{-4}$ to $7.68{\times}10^{-3}mole/cm^2{\cdot}h$. The initial flux of $K^+$ which was irradiated by radiation was found to be from $35.0{\times}10^{-4}$ to $42.4{\times}10^{-3}mole/cm^2{\cdot}h$ and that of $Na^+$ from $52.0{\times}10^{-4}$ to $43.3{\times}10^{-3}mole/cm^2{\cdot}h$. The membrane was selective for $K^+$ and the ratio $K^+/Na^+$ was about 1.10. And the driving force of pH of irradiated membrane was significantly increased about 4-5 times than membrane which was not irradiated. As active transport of $K^+$ and $Na^+$ of cell membrane model were abnormal, cell damages were appeared at cell.

Effect of Surfactant Types on Washing of Diesel-contaminated Soil (디젤 오염 토양 세척시 계면활성제 종류의 영향)

  • Yang, Jung-Seok;Lee, You-Jin;Kim, Seong-Hye;Shin, Hyun-Jae;Yang, Ji-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.3
    • /
    • pp.8-14
    • /
    • 2008
  • The effects of surfactant types and the ratio of nonionic and anionic surfactants on the washing of diesel contaminated soil were investigated. In batch tests, the nonionic surfactant, which has HLB within 12-13, showed a high diesel removal efficiency and Tergitol 15-S-7 (T15S7) with 20 g/L concentration exhibited the highest removal efficiency of 79-88% among the tested nonionic surfactants. Anionic surfactants, in general, showed lower removal efficiency than nonionic surfactants. In case of mixed surfactant system, the removal efficiency increased with nonionic surfactant concentration. With mixed surfactants of T15S7 and SDS as 3 : 1 ratio, diesel removal was enhanced to 76% with 10 g/L of the mixed surfactants. These results could be used in the selection of proper surfactants for remediation of diesel contaminated soils.

Application of Lime Stone, Sand, and Zeolite as Reactive Capping Materials for Marine Sediments Contaminated with Organic Matters and Nutrients (유기물 및 영양염류로 오염된 해양퇴적물 정화를 위한 석회석, 모래, 제올라이트의 반응성 피복 소재로서 적용성 평가)

  • Kang, Ku;Park, Seong-Jik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.8
    • /
    • pp.470-477
    • /
    • 2017
  • In this study, the applicability of calcite, sand, and zeolite for the remediation of sediments contaminated with organics and nutrients were investigated. Sediments and seawater for water tank experiments were sampled from Pyeongtaek harbor, and 1 cm or 3 cm of calcite, sand, and zeolite were capped on the sampled sediments. pH, electric conductivity (EC), dissolved oxygen (DO), chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP) were monitored for 63 days. The sampled sediments were highly contaminated with organic matter and total nitrogen. DO in uncapped condition was exhausted within 10 days but DO in capping condition except 3 cm of zeolite capping was prolonged above 2 mg/L. Capping efficiency for interrupting COD release from sediments was in the following order: zeolite 1 cm > calcite 1 cm > calcite 3 cm > sand 3 cm ${\cong}$ zeolite 3 cm ${\cong}$ sand 1 cm. Zeolite was found to be effective for interrupting nitrogen release. T-P was not observed in both uncapped and capped sediment, i.e., all experimental conditions. It can be concluded that zeolite can be effectively used for the remediation of sediments highly contaminated with organic matter and nitrogen.

Transfer of Genetic Substance Through the Cell Wall of Geranium (Pelargonium zonale hybrids, 'Pinto Scarlet') Callus (제라니움 세포벽을 통한 유전물질의 전이)

  • 유장걸;소인섭;홍경애
    • Korean Journal of Plant Tissue Culture
    • /
    • v.21 no.1
    • /
    • pp.29-34
    • /
    • 1994
  • The possibility that DNA could move out of the single cells isolated from geranium (Pelargonium zonale hybrids, 'PintoScarlet') callus was determined by the elechophoretic DNA analysis after treatment of low pH, various concentrations of KNO$_3$, 2,4-D, and GA$_3$ followed by the centrifugal force, all of which are hewn to and the physico-chemical properties of the cell wall. The centrifugal force of l,800 xg was need for DNA migration after the above treatment, but 7k300 xg was required without the treatments. In this experiment the optimum concentration (300 mg/L) of sodium dodecyl sulfate (SDS) used as an anion detergent to collect the negatively charged DNA was very critical not to damage the cell wall It can be concluded that the centrifugal force played a key role for the DNA migration through the cell wall, and the treatments of low pH (4.0), 0.5% KNO$_3$, 1.5 mg/L GA$_3$and 1mg/L 2,4-D further increased the DNA migration.

  • PDF

Fraction and Mobility of Heavy Metals in the Abandoned Closed Mine Near Okdong Stream Sediments (폐광산 지역 옥동천 퇴적물내에 포함된 중금속의 존재형태 및 이동성)

  • Kim Hee-Joung;Yang Jae-E;Lee Jai-Young;Jun Sang-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.2
    • /
    • pp.44-51
    • /
    • 2005
  • Fractional composition and mobility of some heavy metals in sediments from Okdong stream are investigated. The fractional scheme for heavy metals in the sediment was established for five chemically defined heavy metal forms as adsorbed fraction, carbonate fraction, reducible fraction, organic fraction, and residual fraction. The most abundant fraction heavy metals in the sediments is reducible and secondly abundant is organic fraction. Adsorbed fraction is minor part of the total heavy metals. Mobilization of heavy metals in the sediments from Okdong stream occur $19.8{\sim}56.7%$ of total cadmium concentrate. The most abundant fraction of the sediment metal is organic fraction in Cu, Pb metals investigated. Labile fraction of sediment metals are $0.5{\sim}48.5%$ of total Zn, $2.6{\sim}48.1%$ of total Pb, and $0.2{\sim}36.9%$ of total Cu, respectively. Most of labile fraction consists of reducible fraction for Cd, Zn, adsorbed fraction for Pb, reducible fraction for Cu, adsorbed fraction for Ni. The Mobilization of Zn and Cu is most likely to occur when oxygen depletes and that of Pb and Ni occurs when physical impact, oxygen depletion and pH reduction.

The Effects of Hydroxyl Radical Generation by Means of the Addition of $H_2O_2$ and $Fe^{3+}-EDTA$ in the Electron-beam Process (전자빔 공정에서 $H_2O_2$$Fe^{3+}-EDTA$의 첨가가 수산화라디칼 생성에 미치는 영향)

  • Kwon, Bumgun;Kwon, Joongkuen;Kim, Jongoh
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.10
    • /
    • pp.69-76
    • /
    • 2012
  • This study focuses both on the quantitative measurement of hydroxyl radicals formed by an electron beam (E-beam) process and on the decomposition of pentachlorophenol(PCP) in the presence of $H_2O_2$ and $Fe^{3+}-EDTA$ as additives. To attain this objective, the quantitative measurement of hydroxyl radical was performed with the hydroylation of benzoic acid (BA), producing hydroxybenzoic acid (OHBA). As a result, the concentrations of hydroxyl radical measured were lower than those of hydroxyl radical predicted. Probably, it indicates that the reactive species generated during E-beam irradiation are able to scavenge the hydroxyl radicals. In particular, the degradation of PCP was promoted by the addition of $H_2O_2$ (< 1mM). On the other hand, its degradation as well as the generation of chloride ions as a by-product was inhibited by the addition of $H_2O_2$ (> 1mM), and thus carbon yield(%) of oxalic acid as a by-product was increased. During E-beam irradiation the addition of $Fe^{3+}-EDTA$ effectively decomposed the PCP, thus increasing the G-values. Considering the formation of OHBA and the decomposition of PCP, these results suggest that the addition of $Fe^{3+}-EDTA$ in the E-beam process can produce the further hydroxyl radicals and enhance the efficiency of PCP decomposition at low dose.

Variation in the Properties of Contaminated Coastal Sediment with the Mixing of Alkaline Industrial By-product (알칼리성 산업부산물의 혼합에 따른 연안 오염퇴적물의 성상 변화)

  • Park, Seongsik;Woo, Hee-Eun;Lee, In-Cheol;Kim, Do-Hyung;Park, Jeonghwan;Kim, Jinsoo;Kim, Kyunghoi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.7
    • /
    • pp.914-919
    • /
    • 2019
  • A mesocosm experiment considering water exchange was conducted to evaluate the change in the properties of contaminated coastal sediment. The contaminated coastal sediment sample was prepared by mixing with granulated coal ash(GCA), which is an alkaline industrial by-product. During one month of observation time, the phosphate concentration of the GCA sample case was measured to be 19.0 and 0.4 mg/L lower than that of the control sample at the pore water and overlying water, respectively. The hydrogen sulfide concentration of the GCA sample case was 5.0 mg/L, which is significantly lower than that of the control sample(112.5 mg/L). Further addition of GCA in the sediment reduced the concentrations of phosphate and hydrogen sulfide, and could enhance the adsorption reaction, when compared to the sediment without GCA. The dissolved oxygen concentration in the overlying water of the GCA sample was measured to be 3.47 mg/L higher than the control sample. From the above results, we confirmed that GCA is an effective material for reducing pollutants in coastal sediment.

Solvent Extraction of Li(I) from Weak HCl Solution with the Mixture of Neutral Extractants Containing FeCl3 (FeCl3를 함유한 중성추출제의 혼합용매로 약한 염산용액으로부터 리튬(I)의 용매추출)

  • Xing, Weidong;Lee, Seah;Lee, Manseung
    • Resources Recycling
    • /
    • v.27 no.6
    • /
    • pp.53-58
    • /
    • 2018
  • Solvent extraction of Li(I) from weak HCl solution was investigated by the mixture of TBP/MIBK with other neutral extractants such as Cyanex 923, TOPO and TOP. The TBP/MIBK organic phase was loaded with 0.1 M $FeCl_3$ at different HCl concentrations (1-9 M). Extraction of Li(I) from weak HCl solution is related to the stability of $FeCl_3$ in the organic mixture. As HCl concentration increased in preparing the loaded TBP phase, the stripping percentage of Fe(III) during the extraction of Li(I) became reduced and thus Li(I) could be extracted by ion exchange reaction with hydrogen ion in the organic. The concentration of TBP in the extractant mixture affected the stability of $FeCl_3$. Compared to TBP, Fe(III) was easily stripped from the loaded MIBK and thus no Li(I) was extracted by the mixture with MIBK. The nature of neutral extractant with TBP/MIBK showed little difference in the extraction of Li(I) and stripping of Fe(III).

표면효과에 의한 Si 나노와이어의 전류 전압 특성

  • Park, Seong-Ju;Go, Jae-U;Lee, Seon-Hong;Baek, In-Bok;Lee, Seong-Jae;Jang, Mun-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.409-409
    • /
    • 2012
  • 최근 나노크기의 미세구조 가공기술이 발달함에 따라 다양한 응용을 위한 나노소재/구조가 활발히 연구 되고 있다[1]. 그 중에서 실리콘 나노선은 태양전지, 메모리, 트랜지스터 그리고 광 공진기에 쓰일 수 있는 소재로서 기존의 실리콘 가공기술을 바로 사용할 수 있을 뿐 아니라[2], 비용 면에서 탁월한 잇점이 있기 때문에 주목 받고 있는 소재이다. 실리콘 나노선의 물리적 특성을 연구하기 위한 많은 연구가 진행되었지만, 매우 작은 크기와 높은 표면적-부피비율로 인해 생긴 독특한 특징을 완전히 이해하기에는 아직 부족한 점이 많다. 실리콘 나노선의 전류-전압특성에 영향을 미치는 요소는 도핑농도, 표면상태, 채널의 크기 등으로 다양한데, 이번 연구에서는 실리콘 나노선의 표면환경이 공기와 물 두 종류로 매질에 접하고 있을 경우에 대하여 각각 전류-전압을 측정하였다. 물이 공기와 다른 점은 크게 두 가지로 볼 수 있다. 첫째로 물의 경우에는 물에 용해된 수소이온과의 화학반응을 통하여 실리콘 표면전하가 유도되며 pH 값에 민감하게 변화한다. 둘째로 물의 유전율은 공기의 80배로서 표면부근에서의 전기장분포가 많이 왜곡된다. 이를 위하여 SOI를 기반으로 채널길이 $5{\mu}s$, 두께 40 nm, 너비 100 nm인 실리콘 나노선을 일반적인 반도체공정을 사용하여 제작하였다. 나노선의 전기적 특성 실험은 Semiconductor Parameter Analyzer (Agilent, 4155C)를 사용하여 전류-전압특성을 표면 상태를 변화시키면서 측정하였다. 실험을 통해 실리콘 나노선은 물과 공기 두 가지 표면환경에 따라 전류-전압특성이 확연히 변화하는 것을 볼 수 있었다. 동일한 전압 바이어스에서 표면에 물이 있을 때가 공기 있을 때 보다 훨씬 증가한 전류를 얻을 수 있었고(3V에서 약 2배), 비선형적인 전류-전압특성이 나타남을 관찰하였다. 본 발표에서는 이러한 실험결과를 표면에서의 전하와 정전기적인 효과로서 정성적으로 설명하고, 전산모사결과와 비교분석 하고자 한다.

  • PDF