• Title/Summary/Keyword: 수면효율

Search Result 302, Processing Time 0.03 seconds

Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff (Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong;Hong, Sung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone is widely used in industry, because of its simplicity in design, high capacity, low maintenance and operational cost. The separation action of a hydrocyclone treating particulate slurry is a consequence of the swirling flow that produces a centrifugal force on the fluid and suspended particles. In spite of hydrocyclone have many advantage, the application for treatment of urban stormwater case study were rare. We conducted a laboratory scale study on treatable potential of micro particles using hydrocyclone filter (HCF) that was a combined modified hydrocyclone with perlite filter cartridge. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particles sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin, road sediment, commercial area manhole sediment, and silica gel particles. Experimental studies have been carried out about the particle separation performance of HCF-open system and HCF-closed system. The principal structural differences of these HCFs are underflow zone structure and vortex finder. HCF was made of acryl resin with 120 mm of diameter hydrocyclone and 250 mm of diameter filter chamber and overall height of 800 mm. To determine the removal efficiency for various influent concentrations of suspended solids (SS) and chemical oxygen demand (COD), tests were performed with different operational conditions. The operated maximum of surface loading rate was about 700 $m^3/m^2$/day for HCF-open system, and 1,200 $m^3/m^2$/day for HCF-closed system. It was found that particle removal efficiency for the HCF-closed system is better than the HCF-open system under same surface loading rate. Results showed that SS removal efficiency with the HCF-closed system improved by about 8~20% compared with HCF-open system. The average removal efficiency difference for HCF-closed system between measurement and CFD particle tracking simulation was about 4%.

A study of prostate symptom, sleep quality and quality of life in the community-dwelling korean elderly (남성 노인의 전립선 증상, 수면의 질, 삶의 질에 관한 연구)

  • Shin, Kyung-Rim;Kang, Younhee;Shin, Mee-Kyung
    • 한국노년학
    • /
    • v.28 no.4
    • /
    • pp.1041-1054
    • /
    • 2008
  • This study aimed to identify the severity and types of prostate symptom, to identify the relationship of prostate symptom, sleep quality and quality of life of the elderly in korea, so to provide basic data for developing nursing interventions for the elderly's prostate symptom management. This study used a descriptive correlational research design. The subjects of this study were 100 elderly men over 65yr in an urban city. Data were collected through personal interviews using questionnaires from September 2006 to March 2007. The IPPS, PSQI and SF-36-K were administered. The collected data were analyzed by descriptive statistics and Pearson's correlation. The major findings of this study were as follows: 1) 44% of the participants have moderate to severe Prostate symptom(IPSS>7). 2) Prostate symptom has positive relationship with sleep quality(r=.272, p=.006) and negative relationship with health related quality of life(r=-.197, p=.049). The results of this study indicate that prostate symptom is related to sleep quality and quality of life. So it is necessary to give information to the elderly about the effective coping method of prostate symptom and about the life style which have positive effect to prostate symptom.

A Comparison of the Effects between Eye-Mask and Light-Off Conditions on Psychiatric Patient Sleep (야간 조명 하 안대와 소등의 수면에 대한 효과 비교)

  • Shin, Juyong;Lim, Kyoung-Ok;Cho, Seongnam;Jang, Soyeong;Cha, Seung-Min;Han, Songyi;Kim, Moojin
    • Sleep Medicine and Psychophysiology
    • /
    • v.28 no.1
    • /
    • pp.27-33
    • /
    • 2021
  • Objectives: The purpose of this study is to investigate the difference in the effects of eye-mask and light-off on sleep status according to a commercial fitness tracker and a sleep diary of psychiatric in-patients in correctional facilities where nocturnal light is compulsory. Methods: This study was conducted over 3 consecutive nights. In-patients of the National Forensic Psychiatric Hospital (n = 29) were assigned random subject numbers and slept as usual in the light-on condition on the first night. The subjects slept with eye-masks in the light-on condition on another night and without an eye-mask in the light-off condition on the other night. Subjects were asked to sleep wearing a commercial fitness tracker and to keep a sleep diary. The order of these changes in bedroom lighting condition on the second and third nights was assigned randomly to participants. Results: In comparison of the sleep variables between the light-on condition and the eye-mask condition, the Wakefullness After Sleep Onset (WASO) was shorter and sleep satisfaction was higher in the latter.(respectively, Z = 3.66, p < 0.017 ; Z = 2.69, p < 0.017) In comparison of the sleep variables between the light-on and light-off conditions, the WASO was shorter and sleep efficiency and sleep satisfaction were higher in the latter (respectively, Z = 2.40, p < 0.017 ; Z = 3.02, p < 0.017 ; Z = 3.88, p < 0.017). However, there were no differences in the sleep variables between the eye-mask condition and the light-off condition. Conclusion: Subjective improvements in sleep variables were noted in sleep diaries of institutionalized psychiatric patients under either the 'eye-mask' or 'light-off' condition. However, there were no significant differences between the 'eye-mask' and 'light-off' conditions. Therefore, we suggest that psychiatric patients in correctional facilities use eye-masks when sleeping.

Narcolepsy Variant Presented with Difficult Waking (각성장애로 발현한 기면증의 변종)

  • Lee, Hyang-Woon;Hong, Seung-Bong
    • Sleep Medicine and Psychophysiology
    • /
    • v.7 no.2
    • /
    • pp.115-119
    • /
    • 2000
  • Objectives Summary: A 20-year-old man was presented with a history of difficult waking for 10 years. He suffered from morning headache, chronic fatigue and mild daytime sleepiness but had no history of irresistible sleep attack, cataplexy, hypnagogic hallucination or sleep paralysis. Methods: Night polysomnography (PSG), multiple sleep latency test (MSLT) and HLA-typing were carried out. Results: The PSG showed short sleep latency (4.0 min) and REM latency (2.5 min), increased arousal index (15.7/hour), periodic limb movements during sleep (PLMS index=8.1/hr) with movement arousal index 2.1/hr and normal sleep efficiency (97.5%). The MSLT revealed normal sleep latency (15 min 21 sec) and 4 times sleep-onset REM (SOREM). HLA-typing showed DQ6- positive, that corresponded at the genomic level to the subregion DQB1*0601, which was different from the usual locus in narcolepsy patients (DQB1*0602 and DQA1*0102). Conclusion: Differential diagnosis should be made with circadian rhythm disorder and other causes of primary waking disorder. The possibility of a variant type of narcolepsy could be suggested with an unusual clinical manifestation and a new genetic marker.

  • PDF

A Study on the Development of Sleep Monitoring Smart Wear based on Fiber Sensor for the Management of Sleep Apnea (수면 무호흡증 관리를 위한 섬유센서 기반의 슬립 모니터링 스마트 웨어 개발에 관한 연구)

  • Park, Jin-Hee;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.22 no.1
    • /
    • pp.89-100
    • /
    • 2019
  • Sleep apnea, a medical condition associated with a variety of complications, is generally monitored by standard sleep polysomnography, which is expensive and uncomfortable. To overcome these limitations, this study proposes an unconstrained wearable monitoring system with stretch-fiber sensors that integrate with the wearer's clothing. The system allows patients to undergo examinations in a familiar environment while minimizing the occurrence of skin allergies caused by adhesive tools. As smart clothing for adult males with sleep apnea, long-sleeved T-shirts embedding fibrous sensors were developed, enabling real-time monitoring of the patients' breathing rate, oxygen saturation, and airflow as sleep apnea diagnostic indicators. The gauge factor was measured as 20.3 in sample 4. The maximum breathing intake, measured during three large breaths, was 2048 ml. the oxygen saturation was measured before and during breath-holding. The oxygen saturation change was 69.45%, showing a minimum measurable oxygen saturation of 70%. After washing the garment, the gauge factor reduced only to 18.0, confirming the durability of the proposed system. The wearable sleep apnea monitoring smart clothes are readily available in the home and can measure three indicators of sleep apnea: respiration rate, breathing flow and oxygen saturation.

Comparisons of Subjective and Actigraphic Measurements of Sleep between Shift-working and Daytime Psychiatric Nurses (정신과 교대근무와 주간근무 간호사에서 수면의 주관적 및 활동기록기 평가의 비교)

  • Kwak, Jun;Yoon, Bo-Hyun;Jeon, Bong-Hee;Sea, Young-Hwa;Song, Jye-heon;Park, Su-hee;Kim, Kyung-Min;Jung, Ha-ran;Jeong, Yu-Ran;Park, Jinhyeong
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.25 no.2
    • /
    • pp.166-175
    • /
    • 2017
  • Objectives: Shiftwork is known to be one of the common causes of sleep and health problems and finally causes the decreased quality of life. The purpose of this study was to investigate the sleep patterns of shift-working and daytime psychiatric nurses using actigraphy and compare it with subjective assessment for sleep. Methods : Twenty-three shift-working and 25 daytime nurses were enrolled. They rated their sleep quality using Pittsburgh Sleep Quality Index(PSQI) and other self-rating scales were measured for psychosocial aspects. Actigraphy was applied to the subjects for a total of 7 days to measure the sleep parameters. They also wrote sleep diaries during the period of wearing actigraphy. Sleep-related parameters of actigraphy, global score and components of PSQI, and the results of other self-rating scales were compared between shift-working and daytime nurses. Results : Although the global score of PSQI did not show significant difference, the PSQI components showed significant differences between two groups: the shift-working nurses showed lower sleep quality, more sleep disturbance and hypnotic medication use, and worsened daytime dysfunction than daytime nurses. The shift-working nurses showed significantly shorter total time in bed and total sleep time, lower sleep efficiency, and longer average awakening time than those of daytime nurses in actigraphy. Conclusions : The results showed that shift-working nurses experienced more sleep disturbances in both subjective and objective aspects of sleep than daytime nurses. This study also suggests that actigraphy may be useful to measure the objective aspects of sleep that are difficult to assess with subjective questionnaires alone.

The Effects of Obstructive Sleep Apnea Syndrome on Periodic Limb Movements in Sleep (폐쇄성 수면무호흡증이 주기성 사지운동증에 미치는 영향)

  • Seo, Cheon-Seok;Youn, Tak;Kim, Eui-Joong;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.7 no.1
    • /
    • pp.34-42
    • /
    • 2000
  • Objectives: Periodic limb movements in sleep(PLMS) is a moderately prevalent disorder, of which pathophysiology remains largely unknown. PLMS has been reported to be common in patients with obstructive sleep apnea syndrome(OSAS), but reports on their relationship have been inconsistent in previous studies. Inconsistency of results may be attributable to insufficient number of the study subjects. We attempted to explore the influence of OSAS on PLMS in a large number of subjects. Methods: Three hundred and twenty subjects(M : F=192:128) with PLMS, as identified by the nocturnal polysomnography, were studied. Sample mean age was 53.1(SD=15.1) years and their mean periodic limb movement index(PLMI) is 25.2/hr (SD=24.8). PLMS subjects were divided into two groups, based on the presence or absence of OSAS. Periodic limb movement indices and sleep parameters between two groups were analyzed to evaluate the effects of OSAS on PLMS. Results: Each of PLMI and PLMI with arousal(PLMAI) correlated positively with age. PLMI of men was larger than that of women (p<0.01). The presence of comorbid OSAS independently had influence on PLMI(t=-2.20, p<0.05), but not PLMAI. There were no significant differences between the two groups in their PLMI, PLMAI and sleep parameters. However, the two groups differed in PLMI-correlated sleep parameters. In PLMS subjects with comorbid OSAS, PLMI was negatively correlated with each of slow wave sleep time and REM sleep time. In subjects without comorbid OSAS, PLMI was negatively correlated with sleep efficiency. Conclusion: PLMS patients with OSAS turned out to have increased PLMI than those without OSAS We suggest that OSAS patients may have subtle autonomic arousals and these arousals could, in part, express themselves as PLM.

  • PDF

The Comorbidity of Periodic Limb Movements Disorder in Patients with Sleep-Related Breathing Disorder (수면관련 호흡장애 환자에서의 수면중 주기성 사지운동장애의 동반이환율)

  • Yang, Chang-Kook;Son, Choon-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1039-1046
    • /
    • 1998
  • Background: Sleep-related breathing disorders(SRBD) and periodic leg movements disorder(PLMD) are both common, and are considered as separate sleep disorders. However, both disorders show high comorbidity. SRBD and PLMD can result in excessive daytime sleepiness and insomnia due to frequent sleep fragmentation. So, it is very important to consider the presence of PLMD, when we are dealing with the diagnosis and management of SRBD. The objectives of this study were to determine the incidence of PLMD in patients with SRBD, and to describe any differences between patients with and without PLMD. Method: The authors reviewed the sleep recordings of 106 patients with a final diagnosis of SRBD(obstructive sleep apnea or upper airway resistance syndrome), who underwent full nocturnal polysomnography, including the monitoring of the anterior tibialis electromyogram. All sleep records were recorded and scored using the standard criteria. The data was analyzed by the student t-test. Result: 106 patients(M=76, F=30) were included in the analysis. Data revealed a mean age of $49.5{\pm}13.6$ years, a respiratory disturbance index(RDI) of $22.3{\pm}25.4$/hour sleep, a lowest oxygen saturation of $84.9{\pm}11.3%$, a maximal esophageal pressure of $-41.0{\pm}19.1cmH_2O$, and PLM index(PLMI) of $13.1{\pm}22.4$movements/hour sleep. Forty four percent(47 of 106 patients) had a PLMI of greater than 5 on this study. The mean age of the patients with PLMD was significantly higher than that of the patients without PLMD(p<0.005). Female patients with SRBD accompanied more PLMD(p<0.05). The apnea index of the patients with PLMD was significantly lower than that of the patients without PLMD(p<0.01). The percentage of stage 1 sleep in the patients with PLMD was significantly lower than that of the patients without PLMD(p<0.05). Conclusion: The prevalence of PLMD in the patients with SRBD was high at 44.3%. The patients with PLMD were older and had more high RDI in comparison to the patients without PLMD, which was consistent with previous findings. The authors recommend that more careful consideration of PLMD is required when diagnosing and treating SRBD.

  • PDF

Desingularized indirect boundary integral method를 이용한 2 차원 단면의 동유체력 계산

  • O, Seung-Hun;Yang, Jin-Ho;Kim, Da-Jeong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2015.10a
    • /
    • pp.100-103
    • /
    • 2015
  • 본 연구에서는 선박의 내항 및 조종성능평가를 위해 사용되는 2차원부가질량계수와 파랑감쇠계쉬를 desingularized indirect boundary integral method를 이용하여 주파수영역에서 계산하였다. 본 방법을 Rankine source를 유체경계면 전체에 분포하는 방법으로 수학적으로 간단하고 경계조건의 변경 및 적용이 용이하다는 장점이 있다. 하지만 물체표면, 자유수면 그리고 방사경계면의 계산영역 및 요소의 배치에 따라 계산정확도에 차이가 발생한다. 따라서 본 연구에서는 수치시험을 통해, 자유수면과 방사계면의 적절한 계산영역과 요소의 개수를 결정하였다. 계산의 정도와 효율성을 확보하기 위하여, 자유수면과 방사경계면의 계산영역과 요소의 분포를 파의주파수에 따라 달리 적용하였다. 본 연구에서 제안된 수치방법을 활용하여 계산된 동유체력과 실험에서 계측된 동유체력을 비교하여 본 방법의 정도를 확인하였다.

  • PDF

Wave Generation with a Hydrofoil by More Efficient Free-Surface Boundary Condition (고효율 자유표면 경계조건에 의한 수중익 주위의 파도생성)

  • Kwag, S.H.
    • Journal of Korean Port Research
    • /
    • v.12 no.1
    • /
    • pp.87-93
    • /
    • 1998
  • For the calculation of the free-surface elevation, a new finite difference scheme is studied where the third derivative term for the wave elevation is artificially added in the Eulerian expression of the free-surface boundary condition. The paper presents a comparative analysis with simulations performed by the classical MAC method. More schematic computations are carried out by changing the submergence-depth and angle-of-attack. The present study shows that this new method is very efficient for the simulation of free-surface elevation around the trailing edge.

  • PDF