• Title/Summary/Keyword: 수냉

Search Result 206, Processing Time 0.038 seconds

Changes in Quality of 'Mipung' Chestnut during Storage by Pre-treatment Methods after Harvest (수확 후 전처리 방법에 따른 '미풍' 밤의 저장 중 품질 변화)

  • Oh, Sung-Il;Park, Yunmi;Kim, Mahn-Jo
    • Journal of Korean Society of Forest Science
    • /
    • v.104 no.4
    • /
    • pp.558-563
    • /
    • 2015
  • The effects of pre-treatment methods (water cooling, water cooling+ozone, precooling+microbubble, water cooling+ozone+microbubble) after harvest on the quality of 'Mipung' chestnut were studied. Changes in quality of chestnut were greater precooling treatments effect than washing treatments. But, decaying rate and total microorganism were significantly differences among treatments. The decaying rate after 12 weeks storage was highest at 20.0% in non-treatments and lowest at 3.3% in water cooling+ozone and water cooling+ozone+microbubble treatments. The total microorganism immediately after washing treatments was in the order non-treatments (4.4 log CFU/g) > water cooling treatments (4.0 log CFU/g) > water cooling+ozone+microbubble treatments (3.5 log CFU/g) > water cooling+ozone treatments (3.4 log CFU/g) > water cooling+microbubble treatments (3.3 log CFU/g), and after 12 weeks storage was increased within 4.7 to 5.9 log CFU/g. Thus, the washing treatments, especially ozone treatments, extended the shelf-life of the 'Mipung' chestnut by inhibiting the decaying.

CFD Analysis of CPU Water Cooler Jacket (CPU 수냉식 쿨러 자켓의 유동해석)

  • Lee Jong-sun;Park Dong-Seuk
    • Proceedings of the KAIS Fall Conference
    • /
    • 2005.05a
    • /
    • pp.75-78
    • /
    • 2005
  • 본 논문은 CPU의 수냉식 쿨러 자켓에 대하여 CFD(computational fluid dynamics) 해석을 수행하여 내부면적이 큰 쿨러 자켓의 효율이 어느 정도 좋은 지를 내부면적이 작은 쿨러 자켓과 비교 분석한다. 쿨러 자켓이 냉각수와 열 교류를 원활히 할 수 있도록 쿨러 자켓의 온도분포를 통하여 적절한 형상을 설계하여 CPU 수냉식 쿨러 자켓의 제작시 설계 자료로 이용하고자 한다.

  • PDF

Maximum Efficiency Point Tracking Method for Liquid Cooled Inverter (수냉형 인버터의 최대 효율 출력 추적 방법)

  • Kim, Sang-Hyun;Kim, Kwang-Seob;In, Dong-Seok;Lee, Jong-Hak;Park, Young-Min;Won, Seon-Min
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.538-539
    • /
    • 2012
  • 수냉형 인버터는 냉각 시 칠러를 사용하게 되는데 칠러는 입력 냉각수의 온도가 높을수록 열교환 효율이 높아져 소비전력이 감소한다. 하지만 인버터는 입력 냉각수의 온도가 높을수록 손실이 증가하게 되므로 수냉형 인버터는 각각의 출력 부하에 따라 최대 효율 점이 존재한다. 본 논문에서는 각각의 출력 부하에서 냉각수 온도 제어를 통해 수냉형 인버터의 최대 효율점을 추적하는 방법을 제안한다.

  • PDF

Development and Operation of Air Cooling System for 154kV Power Transformer (154kV 변압기 공냉형 수냉식 냉각설비 개발 및 운전)

  • Min, Byeong-Wook;Shin, Myoung-Sik;Cho, Hwan-Gu;Choi, Joon-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.932-933
    • /
    • 2011
  • 지속적인 경제발전 및 이상 기후변화 등으로 인한 전력수요의 지속적 증가로 2010년에 최대 66,511MW, 2011년에는 4월 현재까지 최대 68,154MW를 기록하고 있어 원활한 전력공급을 위한 전력설비의 지속적인 건설이 요구되고 있다. 그러나 건설지역 주민들의 민원 등으로 인해 건설은 갈수록 어려워지고 있는 실정이다. 한전에서는 변전소 건설의 경제성을 확보하고 변전소 건설 부지면적 및 건물면적을 최소화한 154kV Compact형 변전소를 개발하게 되었다. 이를 위해서는 변전소 면적의 상당부분을 차지하고 있는 변압기 설치면적 최소화가 필수적이다. 이를 위해 변압기 설치공간 최소화하고 냉각효율 및 민원 등을 고려한 냉매냉각방식(HCFC:Hydro Chloro Carbons, 수소화염화불화탄소)의 적용을 추진하였으나 HCFC는 오존파괴물질로 규정되어 생산과 수입이 규제될 예정으로 한전은 냉매냉각방식의 대안으로 기존 수냉식 냉각방식의 환경문제, 냉각탑 관리의 어려움 등과 물 비산에 따른 상하수도 이용요금 부담 등의 단점을 개선한 공냉형 수냉식 냉각방식을 개발하게 되었다. 본 논문에서는 154kV 변압기 공냉형 수냉식 냉각방식의 개발내용 및 운전현황에 대해 기술하고자 한다.

  • PDF

Empirical Study on water wall tube corrosion mechanism for Tangential type coal fired power plant boiler (석탄화력발전소 보일러의 수냉벽튜브 부식 메카니즘에 대한 실증적 고찰)

  • Baek, Sehyun;Kim, HyunHee;Park, Hoyoung;Ko, SungHo
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.49-55
    • /
    • 2014
  • In this study, boiler tube thickness measurement and numerical analysis were conducted for standard 500MW coal-fired power plant in order to research the mechanism of tangential-fired boiler corrosion empirically. The most dominant corrosion mechanism of tangential-fired boiler waterwall was corrosion by sulfur contained in the unburned carbon. And the secondary mechanism was $H_2S$ gas corrosion at localized reducing atmosphere. It is required to decrease the air-stage combustion operation in order to mitigate the waterwall tube corrosion. Also stringent coal pulverization quality control and reinforcing work for corrosion susceptible area such as anti-corrosion coatings is required

Water Cooling Pipe Optimal design for Heat-Dissipation of wind power converter system (풍력발전용 전력변환기의 방열을 위한 수냉식 배관 최적 설계)

  • Choi, Jin-Ho;Oh, Seung-Yeol;Choi, Jung-Sik;Yang, Seung-Hak;Kim, Dae-Kyong
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.485-486
    • /
    • 2011
  • 대용량 전력변환기에서 대부분의 열은 IGBT 소자에서 발생한다. 따라서 소자의 방열을 위한 방열시스템은 전력변환기의 구동 뿐 아니라 각 장치들에 대한 소형, 경량화의 추세에 있어서도 중요한 부분을 차지한다. 본 논문에서는 소자의 냉각을 위해 수냉식 방법을 선정하였으며, 배관 구조에 따른 방열판의 방열특성을 비교하여 최적의 배관 구조를 가진 수냉식 방열판을 제안하였다.

  • PDF

Fin Patterns For Heat Sinks in Water Cooling Loops of Power Converter System (휜유로 구조를 갖는 전력변환 시스템 방열판 설계)

  • Song, Sung-Geun;Choi, Jin-Ho;Kim, Do-Hyoung;Jang, Mi-Geum;Kim, Dae-Kyong
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.487-488
    • /
    • 2011
  • 본 논문에서는 풍력발전용 전력변환기 내부 소자의 방열에 사용되는 수냉식 방열판의 관 형상을 제안한다. 최근 대용량 전력변환기는 소형화 및 효율성이 중요시 되고 있으며, 이에 따라 기구의 안정적이고 장기적인 운영을 위한 수냉식 방열설계가 필수적이라 할 수 있다. 수냉식 방열판는 다수의 원형관으로 구성되며, 이 원형관의 형상은 방열판의 열전달 성능에 직접적인 영향을 주게 된다. 따라서 본 논문에서는 열전달 촉진을 위한 방열판의 관 형상들을 모델링하고 열해석 시뮬레이션을 진행하여 모델링된 방열판들의 방열특성을 비교/분석하였다.

  • PDF

Water-Cooling System of HVDC System (HVDC 시스템의 수냉식 냉각 시스템)

  • 김찬기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.257-267
    • /
    • 1999
  • This paper deals with the water cooling system of HVDC(High Voltage Direct CUlTentJ. It is generally accepted that water is a veη effective medium to remove heat losses from any type of equipment. Because of this benefits the water cooling method is used in HVDC. The water cooling system consists of a heat exchanger, circulation pump and a connecting pipe. According to thYI1stor temperature level. thyristor junction temperature is controlled by controlling the f fan of exchanger. In this paper. the water cooling system of HVDC system is analyzed and estimated.

  • PDF

Simulation of Remote Field Scanner for Defect Evaluation of Water Wall Tube Within the Fluidized Bed Boiler (유동층보일러 수냉벽튜브 결함평가를 위한 원격자장 스캐너 시뮬레이션에 관한 연구)

  • Gil, Doo-Song;Jung, Gye-Jo;Seo, Jung-Seok;Kim, Hak-Joon;Kwon, Chan-Wool
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.145-150
    • /
    • 2020
  • Water wall tube is one of the major factors consisting of a fluidized bed boiler and it plays very important role for the generation of electricity within the boiler. But these water wall tubes within the fluidized bed boiler are subject to the ware and corrosion caused by the high temperature gas and the flowing medium. If water leak is occurred, the secondary damage by the water leak will occur. As a result of that, the power generation efficiency decreases noticeably. Therefore, the maintenance of the water wall tube is very important. In this study, we designed a exciter sensor based on simulation and composed a remote field eddy current system for the defect evaluation of the outer water wall tube. Starting from the shape design of exciter, we conducted simulations for various design factors such as the water wall tube size, material, frequency, lift-off and so on. Based on the results, we designed the optimum exciter sensor for the water wall tube test within the fluidized bed boiler.

Design and Performance Evaluation for the 2MVA Water-Cooled PCU (2MVA 수냉형 PCU 설계 및 성능검증)

  • Kim, Sang-Hyun;Lim, Chang-jin;Han, Jong-Hee;Kim, Yun-hyun;Kim, Kwang-Seob
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.506-507
    • /
    • 2011
  • 본 논문에서는 신재생에너지의 에너지 백업용으로 사용되어지는 2MVA BESS(Battery Energy Storage System)의 수냉형 PCU(Power Conditioning Unit)을 설계하고 3D 모델링 및 열해석을 통해 열적 안정성을 확인하고 이를 실험으로서 검증한다.

  • PDF