Browse > Article
http://dx.doi.org/10.5855/ENERGY.2014.23.4.049

Empirical Study on water wall tube corrosion mechanism for Tangential type coal fired power plant boiler  

Baek, Sehyun (KEPRI)
Kim, HyunHee (KEPRI)
Park, Hoyoung (KEPRI)
Ko, SungHo (Chungnam University)
Publication Information
Abstract
In this study, boiler tube thickness measurement and numerical analysis were conducted for standard 500MW coal-fired power plant in order to research the mechanism of tangential-fired boiler corrosion empirically. The most dominant corrosion mechanism of tangential-fired boiler waterwall was corrosion by sulfur contained in the unburned carbon. And the secondary mechanism was $H_2S$ gas corrosion at localized reducing atmosphere. It is required to decrease the air-stage combustion operation in order to mitigate the waterwall tube corrosion. Also stringent coal pulverization quality control and reinforcing work for corrosion susceptible area such as anti-corrosion coatings is required
Keywords
Corrosion; boiler; waterwall;
Citations & Related Records
연도 인용수 순위
  • Reference
1 EPRI : "Waterwall wastage in low NOx Boilers TR-111155", (2006)
2 EPRI : "Waterwall wastage mechanism in coal fired boilers TR-1004021", (2001)
3 Nava. Paz, J. C., Plumley, A. L. : "Chow, O. K. and Chen, W., "Waterwall corrosion mechanisms in coal combustion environments," Materials at High Temperatures, Vol.19, No. 3, pp.127-137. (2002)   DOI
4 서상일: "미분탄 보일러의 수냉벽 부식기구 규명 및 부식속도 예측에 관한 연구", 충남대학교 학위논문, pp. 26-48. (2009)
5 김태형 서상일 박호영 김영주 : "저 NOx 연소 환경에 의한 미분탄 연소로의 화염측 부식 연구", 대한기계학회 춘추학술대회 Vol.2006 No.6, (2006)
6 Kung,S.C.:"corrosion Studies for Low NOx Burner Technology,"EPRIReportTR-108750. (1997)
7 Bakker, W.T. : "The effect of deposits on waterwall corrosion in fossil fuel boilers", Materials at High Temperatures, Vol. 20, No. 2, pp.161-16(2003)   DOI