• 제목/요약/키워드: 송전선용

검색결과 14건 처리시간 0.04초

국내외 정보

  • 한국전기산업진흥회
    • NEWSLETTER 전기공업
    • /
    • 95-6호통권127호
    • /
    • pp.17-47
    • /
    • 1995
  • PDF

송전선용 현수애자 양생공정에서 발생하는 접착부의 응력변화 (Stress Response of Cement Interface on Manufacturing Process of a Suspension Insulator)

  • 우병철;한세원;조한구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1448-1450
    • /
    • 2003
  • The suspension insulators are subjected to harsh environment in service for a long time. Long term reliability of the insulators is required for both mechanical and electrical performances. We studied an analysing method to find out a deformation of brittle porcelain with a thermal expansion of simulation analysis and experimental results show that cement volume growths affect severely to be mechanical failure ageing.

  • PDF

송전선용 고질소강선의 비틀림 특성에 미치는 열처리의 영향 (Effect of Heat Treatment on Torsion Characteristics of High Nitrogen Steel Wire for Overhead Conductors)

  • 김정훈;김봉서;박수동;김병걸;이희웅
    • 한국전기전자재료학회논문지
    • /
    • 제17권2호
    • /
    • pp.190-195
    • /
    • 2004
  • The effect of heat treatment on torsion characteristics of high nitrogen steel wire has been studied by torsion test, tensile test, specific resistivity, X-ray diffraction and scanning electron microscopy. After heat treatment at 600∼$700^{\circ}C$, torsion cycle was increased with increasing temperature. Especially, in case of high nitrogen steel wire heat teated at $650^{\circ}C$, torsion cycle was sharply increased. It is estimated that cold worked high nitrogen steel wire started to recrystallize and phase transform at 64$0^{\circ}C$ in air atmosphere.

내뢰성 향상을 위한 154 kV 송전선용 피뢰기의 성능 시험 (A Type Test of 154 kV Transmission Line Arrester for improvement of lightning performance)

  • 곽주식;강연욱;우정욱;심응보;박윤석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.454-456
    • /
    • 2003
  • This paper describes a type test results of 154 kV transmission line arrester with external gap. The test was carried on surge arrester unit and line arrester with external gap, respectively. Withstand voltage test demonstrate the voltage withstand capability of the line arrester with external series gap under the dry and wet conditions. In insulation coordination test external series gap shall be discharged every time when lightning impulse voltage with the steepness of more than 1500 $kV/{\mu}s$ are applied under the wet condition.

  • PDF

Al-0.24Zr 합금 도체의 물성향상에 미치는 제 3원소의 영향 (Effects of 3rd Element Addition on the Property Improvement of Al-Zr Conductor Wire)

  • 박수동;현석규;김병걸;김봉서;이희웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1244-1247
    • /
    • 2004
  • 본 연구에서는 송전선용 내열 Al합금인 Al-Zr합금의 내열성과 도전율을 동시에 향상시키기 위해 제 3원소(Mm(misch metal), Ag, Be)를 첨가하고 이것에 의한 물성변화를 공정별로 추적분석 하였다. 본 연구에 의해 측정된 주요 물성은 공정에 따른 미세조직 변화와 경도 및 도전율 둥이 측정, 조사되었다. 연구결과, Mm첨가에 의해 주조조직은 미세화 되었으며 경도와 도전율은 향상되었다. Be첨가에 의해서는 급냉 후 주조조직이 조대화 하였고 주조상태에서 이미 60%IACS에 근접하는 우수한 도전율을 나타내었다. 또한 주조 후 열처리 과정에서 주조조직의 분해는 촉진되었으며 시효석출과정에서는 $Al_3Zr$상의 석출은 억제되었다. 그러나 Al-Zr합금에 대한 Ag의 첨가는 경도와 도전율 모두에서 큰 영향을 주지 않는 것으로 판단되었다.

  • PDF

송전선용 비접촉식 커플러의 설계와 적용연구 (Study on Design and Application of an Inductive Coupler for Power Transmission Line)

  • 김현식;이동철;김민호;이진;오영우;민병훈
    • 한국전기전자재료학회논문지
    • /
    • 제23권3호
    • /
    • pp.234-239
    • /
    • 2010
  • An inductive coupler, which feeds communication to the electric power transmission line, is required to establish Power Line Communication(PLC). The electro-magnetic property of magnetic core and design technology for coupler are very important to manufacture an inductive coupler for power transmission line. The magnetic core with superior electro-magnetic property was manufactured by using nanocrystalline alloy and an inductive coupler, which can operate at the maximum 2,000 A current, was designed and manufactured by establishment of current saturation, signal out winding, and electromagnetic simulation in this study. Communication speed of 14 Mbps in 600 meter communication distance of the real electric power transmission line was obtained by using the inductive coupler and application possibility of the inductive coupler for the electric power transmission line was certified.

송전선용 대용량 신호결합장치의 설계 (Design of an Inductive Coupler for Power Transmission line)

  • 김현식;변우봉;김종령;배을록;이동철;이해연;이준희;지민권
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.439-440
    • /
    • 2008
  • An inductive coupler, which feeds communication to the electric power transmission line, is required to establish Power Line Communication(PLC). The electro-magnetic property of magnetic core and design technology for coupler are very important to manufacture an inductive coupler for power transmission line. The magnetic core with superior electro-magnetic property was manufactured by using nano-crystalline alloy and an inductive coupler, which can operate at the maximum 2,000 A current, was designed and manufactured by establishment of current saturation, signal out winding, and electro-magnetic simulation in this study. Communication speed of 14 Mbps in 600 m communication distance of the real electric power transmission line was obtained by using the inductive coupler and application possibility of the inductive coupler for the electric power transmission line was certified.

  • PDF

전도도 센서를 이용한 송전선용 애자의 염분량 검출 (A Detection of Salt Contamination on the Transmission Line Insulator Using Conductivity Sensor)

  • 강연욱;심응보;권동진;곽주식;정창수;이옥배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.189-193
    • /
    • 2002
  • Outage caused by contaminated insulator on high voltage transmission line and in substation is major concern for utility world-wide. To prevent these outages, it is necessary to develop an automatic salt contamination detecting device which provide the information about contamination level on utility for engineer to meet the emergency in advance. For that purpose, we have been developing an automatic salt contamination detecting device to monitor a salt amount on operating power utility area. In the salt contamination detecting device development, the most important thing is the sensor which can detect a salt amount and the understanding of sensor' s detecting principle. This paper describes the operating principle of the sensor and the experimental results about the detecting of salt amount. The results of this experiment wi1l be useful for detecting the contamination level.

  • PDF

가공송전선용 고질소강의 시효시간에 따른 기계적 특성의 변화 (Mechanical Properties with Aging Time in High Nitrogen Steel for Transmission Line)

  • 김봉서;유경재;권해웅;이희응;김병걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1664-1666
    • /
    • 1999
  • In order to study the mechanical properties of high nitoren steel with ageing time, hardness, tensile stress several basic properties of Fe-Mn-Cr-Ni-N steel have been studied. With increasing partial pressure of nitrogen and ageing time to 10h, hardness and tensile stress are increased, but decreased beyond 10h because of over ageing. It is considered that the main factor related with mechnical properties is carbide precipitate, $M_7C_3$ which is precipitated with ageing time in matrix and optimum ageing time is 10h in $60^{\circ}C$.

  • PDF