• Title/Summary/Keyword: 손상원인

Search Result 1,050, Processing Time 0.032 seconds

Durability Evaluation and Defect Pattern Analysis in Railway Bridge Through Field Investigation (현장조사를 통한 철도 고가교 구조물의 내구성 평가 및 결함 패턴 분석)

  • Kwon, Seung Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.1
    • /
    • pp.10-20
    • /
    • 2013
  • Because of the defect in design, damage in using period, and deterioration in long term exposure to severe environmental condition, degradation of performance in RC (Reinforced Concrete) structures has occurred. This paper contains durability performance evaluation in railway bridges which covers eight districts through field investigation. For the target structures, durability performance is evaluated and the critical problems in use are derived. Additionally, service lifes for the deteriorated structures are evaluated through Durability-Environment index method based on the results from field investigation, and the results are compared with those from the condition assuming the structures without defect, damage, and deterioration. The target structures which consist of RC T girder, PSC girder, RC box, and Rahmen are investigated and the critical damage patterns are derived. They are evaluated to be cracks in PSC girder end, flexural cracks in PSC girder, crack around EPT anchor, and flexural cracks in RC T girder and RC box. The reasons for the critical patterns are also investigated. This study can be utilized for the repair planning considering the different district and the structure types.

A Sunglasses Design to Prevent Snow Blindness at High Altitude (설맹 방지를 위한 고소등반용 선글라스 디자인)

  • Choi, Byung-Jin;Jang, Joon-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.19-22
    • /
    • 2007
  • Recently, the population of people exploring High Mountain trekking or expedition is increasing as an increase in the backpackers. Many accidents occurring at High Mountain above 6,000 m are the results of snow blindness. The damage of cornea and/or retina is direct cause of snow blindness. The UV intensity increases on the hand, along with the altitude caused by decrease in the atmospheric pressure, on the other hand the reflections by bright snow at high mountain area. And it increases approximately 3 times and 4 times higher than the ground level at altitude of 4,000 m and 8,000 m, respectively. The use of sunglasses is more favorable than goggles for the protection of snow blindness at High Mountains. The eye frames that have high mechanical strength and the plastic lenses which can protect UV 100% are recommended. The attachable shielding pads are needed to prevent the incident UV light reflected or scattered from the gap between glasses frame and face. The sunglasses must have flexible and long temples to wind the ears adequately for the prevention of detachment during climbing and it is recommended that the metal frame to be coated with plastics to prevent the eye surroundings from frostbite.

  • PDF

A case of severe transient hyperammonemia in a newborn (신생아의 심한 일과성 고암모니아혈증 1례)

  • Hwang, Min-Woo;Yu, Seung-Taek;Oh, Yeon-Kyun
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.4
    • /
    • pp.598-602
    • /
    • 2010
  • Transient hyperammonemia in a newborn is an overwhelming disease manifested by hyperammonemic coma. The majority of affected newborns are premature and have mild respiratory syndrome. The diagnosis may be difficult to determine. This metabolic disorder is primarily characterized by severe hyperammonemia in the postnatal period, coma, absence of abnormal organic aciduria and normal activity of the enzymes of the urea cycle. Hyperammonemic coma may develop within 2-3 days of life, although its etiology is unknown. Laboratory studies reveal marked hyperammonemia (>$4,000{\mu}mol/L$). The degree of neurologic impairment and developmental delay in this disorder depends on the duration of hyperammonemic coma. Moreover, the infant may succumb to the disease if treatment is not started immediately and continued vigorously. Hyperammonemic coma as a medical emergency requires dialysis therapy. Here, we report a case of severe transient hyperammonemia in a preterm infant (35 week of gestation) presented with respiratory distress, seizure, and deep coma within 48 hours and required ventilatory assistance and marked elevated plasma ammonia levels. He survived with aggressive therapy including peritoneal dialysis, and was followed 2 years later without sequelae.

Splicing Techniques in the PES System Layer for the Editing at a GOP Module of The MPEG-2 based Images (MPEG-2 기반영상 GOP 단위 편집을 위한 PES 시스템 영역에서의 스트림 접함 방법)

  • 김동준;최윤식
    • Journal of Broadcast Engineering
    • /
    • v.7 no.4
    • /
    • pp.355-361
    • /
    • 2002
  • In this paper, several methods which guarantee the seamless editing when the splicing is applied to the MPEG-2 system streams are described. In the MPEG-2 system standard, it is recommended that the splicing technique is applied in the Transport Stream(TS) domain. However, in view of the video editing, the splicing at an arbitrary picture unit can not be guaranteed. The splicing in the PES domain is only considered in this paper because the PES is one of the MPEG-2 system streams and this result could be directly extended to the video splicing techniques in the TS or PS domain. Thus. the problems that might occur when different two PES streams are spliced and its effects to the video quality are compared and analyzed. Based on this analysis. several methods that can resolve these problems directly in the PES domain are proposed. Consequently, the computer simulation demonstrates that the splicing at a GOP modulo is guaranteed to have good video quality even without considering the state of the PES packet only if the PES_packet_length field of the PES packet header is used.

Ultrasonographic Diagnosis of Retained Wood Foreign Body in the Finger (초음파를 이용하여 진단한 수지 잔존 식물성 이물질 - 증례 보고 -)

  • Kim, Joo Yong;Choi, Jang Seok;Kim, Jung Han;Jeong, Dong Woo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.1
    • /
    • pp.20-23
    • /
    • 2011
  • Penetrating injury and retained foreign substances in human body are the main causes of visiting to the emergency room. In hand, foreign substances are caused by trauma. The most common plant pieces, the glass fragments and metal fragments should occur in the order. Especially, it's hard to find fragments of plants and plastic materials because of their radiolucency. And although these fragments are removed, it's difficult to differentiated clearly whether residual foreign bodies are in human hand or not. This study reports the authors' experience in the treatment of a patient from whom he removed a residual tree thorn in the operating room. The thorn was found 4 weeks after the trauma by ultrasonography and then the patients' symptoms were improved.

  • PDF

3D Analysis of Crack Growth in Metal Using Tension Tests and XFEM (인장 실험과 XFEM을 이용한 금속 균열 성장의 3 차원적 분석)

  • Lee, Sunghyun;Jeon, Insu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.4
    • /
    • pp.409-417
    • /
    • 2014
  • To prevent the occurrence of fractures in metal structures, it is very important to evaluate the 3D crack growth process in those structures and any related parts. In this study, tension tests and two simulations, namely, Simulation-I and Simulation-II, were performed using XFEM to evaluate crack growth in three dimensions. In the tension test, Mode I crack growth was observed for a notched metal specimen. In Simulation-I, a 3D reconstructed model of the specimen was created using CT images of the specimen. Using this model, an FE model was constructed, and crack growth was simulated using XFEM. In Simulation-II, an ideal notch FE model of the same geometric size as the actual specimen was created and then used for simulation. Obtained crack growth simulation results were then compared. Crack growth in the metal specimen was evaluated in three dimensions. It was shown that modeling the real shape of a structure with a crack may be essential for accurately evaluating 3D crack growth.

Photodegradation Characterization of Polyolefin Composite (폴리올레핀 복합소재의 UV 광열화 특성)

  • Weon, Jong-Il;Shin, Sei-Moon;Choi, Kil-Yeong
    • Applied Chemistry for Engineering
    • /
    • v.20 no.5
    • /
    • pp.511-516
    • /
    • 2009
  • Photodegradation characteristics of polyolefin composites were studied. Thermogravimetric analysis results suggest that the polyolefin blends used in this study have different amounts of talc. The mechanical behaviors of polyolefin blends, which experienced UV-irradiation in accordance with SAE J1960, are investigated using tensile and Izod impact tests. These results show that as the UV-exposure time increases, a significant drop in the elongation at break and impact strength at a low temperature are observed. This may be explained by the decreases in elastic energy derived from the scission of polymer molecular chains and the low density of entanglement after UV- photodegradation. Scanning electron microscopy observations indicate that no crack and surface damage are observed, while the additional talc particles are exposed, on the UV-exposed surfaces. The exposure of talc particles may be responsible for the discoloration of UV-exposed polyolefin blend surface. Observation using Fourier transform infrared spectroscopy (FT-IR) confirms the presence of photodegradation on the surface of UV-exposed polyolefin blend.

Effect of Harmonic Generation and Countermeasures (고조파발생에 따른 영향과 대책 연구)

  • Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.91-97
    • /
    • 2015
  • Skyscrapers, large business buildings, and IT consumers use many appliances, and the electrical power stems can cause fires by overheating. This can result in damaged capacitors, lost data, rising ground potential, and communication obstacles from linear or nonlinear high frequency. To make sure of that we investigated 7 spots of a building, among which 6-spots were fair but the other one needed high frequency control. Spots 3, 6, and 7 needed diagnostic workup, and spots 2, 3, and 5 considered 5 high frequency currents. A phase is all of good but the high frequency current is greater than the standard level except for spot 1. As a result, a zigzag transformer or active filter needs to be installed, and the efficiency needs to be upgraded by investigating load unbalance factors and power factors.

Tensile Adhesive Chracteristics of Waterproofing System for Concrete Bridge Decks (교량 바닥판 조건에 따른 교면방수 시스템의 인장접착 특성)

  • Lee, Byung-Duck;Shim, Jae-Won;Park, Sung-Ki;Kim, Kwang-Woo
    • International Journal of Highway Engineering
    • /
    • v.4 no.3 s.13
    • /
    • pp.15-23
    • /
    • 2002
  • The waterproofing system's performance is known to show a determing by complex interaction of material factors, design details, and the quality of construction, and the waterproofing integrity of waterproofing membranes is determined by the bond to the deck and the amount of damage to the waterproofing membrane. In this research, the basic properties of waterproofing membranes on market and the tensile adhesive chracteristics of waterproofing systems of concrete bridge deck have also been investigated in the view of the damages frequently reported from job site. For the tensile adhesive strength of sheet waterproofing membranes, the results after asphalt concrete paving tends to increase more than before those. The results of the liquid waterproofing membranes are upside-down, and the more concrete has strength, the more strength of tensile adhesive increase. The ambient temperature of asphalt concrete when application of the waterproofing membrane has considerable influence on the performance of waterproofing system. As described above, waterproofing system can be influenced by several factors. If they are not considered under construction, the overlooking will cause the damages of pavement and waterproofing system after traffic opening.

  • PDF

Computed Tomographic Features of Blunt Abdominal Trauma in a Dog (개에서 컴퓨터단층촬영을 이용한 복부 장기 열상 진단 1례)

  • Park, Hyun-young;Seo, Ji-won;Lee, Young-won;Choi, Ho-jung
    • Journal of Veterinary Clinics
    • /
    • v.33 no.1
    • /
    • pp.39-42
    • /
    • 2016
  • A 10 months old, male Poongsan dog was referred with a history of right forelimb lameness due to hit by a car a few hours before presentation. On the physical examination, the dog showed pale mucous membrane, respiration distress, and skin abrasions. The main laboratory finding was leukocytosis, while hematocrit was normal. Abdominal radiography revealed the loss of abdominal serosal detail, which was diagnosed as peritoneal hemorrhage on ultrasonography (US) and aspiration. On computed tomography (CT), hepatic and splenic injuries were seen characterized by the discontinuity of the capsule with irregular margin and lower density lesions than parenchyma. No contrast enhancing area were shown in the laceration lesion. The accessory spleen was incidentally found by US and CT. In this case, acute intra-abdominal hemorrhage from splenic and hepatic laceration was diagnosed using CT.