Study on the Validity of Recently Introduced Wrist Watch Type Heart Rate Monitoring Device (최근 소개된 손목형 심박수 측정 장치의 유용성에 관한 연구)

  • Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • There are several ways to analyse stress resulting from anxiety and fear within dental treatment for children. Surveying questionnaires and monitoring biologic reaction are the most common ways for evaluating stress. Pulse oximeter is a popular device for detecting heart rate but not appropriate for moving children. In this study, we compared a recently introduced wrist- watch type heart rate monitor(Alpha, MIO, USA) with a pulse oximeter(MP110, MECKIS, Republic of Korea) for 10 attendants with two conditions including resting state and excited state after exercise. Data were analyzed using Wilcoxon Signed Rank test and there is no statistical difference between two devices(p < 0.05).

The Assessment of Stress of Children under Dental Procedures Using Wrist Watch Type Heart Rate Monitoring Devices - Using New Device for Stress Assessment in Children During Restorative Dental Treatment (손목형 심박수 측정 장치를 이용한 어린이의 치과진료 시 스트레스 평가)

  • Oh, Jungeun;Kim, Jongsoo;Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.2
    • /
    • pp.119-125
    • /
    • 2015
  • Dental stress is suggested as a main reason for behavioral problems in dentistry, especially in children. Heart rate is a useful measure of dental stress. The purpose of the present study is to examine the effect of dental stress on children receiving restorative treatment under local anesthesia by using recently introduced a wrist-watch type heart rate monitoring device. Eighteen children with no previous dental experience, who needed dental treatment involving local anesthesia, were included in this study. In each session, heart rate was recorded. The largest increase was observed during local anesthesia and the highest values were recorded during preparation. However, no significant relationship was found between the measurements(p > 0.05). Regarding the number of visits, heart rate on the second session is significantly higher than the first session and the third session(p < 0.05). There was no significant different correlation between the first session and third session(p > 0.05). Based on the present study, children who have no previous dental treatment appeared to be more stressed at the second session and need at least 3 sessions to feel less stressed during dental treatment including dental injection.

A Study on the Implementation of Transmission type PPG Measurement Device in a Wrist Watch (손목시계 형태의 투과형 PPG 측정 장치의 구현에 관한 연구)

  • Kim, Namsub
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.2
    • /
    • pp.161-167
    • /
    • 2017
  • This paper presents an effective PPG measurement device in a wrist watch for smart healthcare. PPG can be acquired by measuring absorption of light and PPG measurement device is classified as transmission and reflection type. Reflection type is easy to implement but vulnerable to motion artifact. Moreover, reflection type must use 2 hands at once if the device is implemeted in a wrist watch. This paper describes the implementation of robust transmission type PPG measurement device by using previous developed reflection type device. PPG sensor is clip type and can be separated from the device so that the influence of motion artifact can be reduced. The proposed device can transmit the measured signal in real-time and is useful for smart healthcare. For evaluation of the proposed device, PPG signals are compared with reflection type in the same condition. The results show that the proposed device has 20% improvement in performance.

Design of A Portable Device for Measuring Heart Rate Using Harmonic Signal and Adaptive Filter (하모닉 신호와 적응 필터를 이용한 휴대형 심박수 측정 장치 설계)

  • Lee, Ju-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.723-728
    • /
    • 2010
  • This study proposed a design of a portable device for measuring heart rate using photoplethysmograph signal to minimize load of a nurse increased from insufficiency of an internal hospital nurse, and algorithm to measure reliable heart rate in PPG signals despite the existence of patient's motion artifacts. The proposed method for measuring heart rate is the method to minimize the motion interference by using the adaptive filter based on harmonic characteristic of PPG signal. To evaluate the performances of the a portable device implemented by the proposed method, we used several motion artifacts including finger and wrist movements; we then compared out results with the performance of the moving average filter. In this results, the proposed method showed a better performance than that of the moving average filter. Therefore, when nurses use the a portable device for measuring heart rate proposed in this study, it will enable to improve nurse work and to measure the reliable heart rate.

Design of the Blood Pressure Measurement System Using the Inflatable Oscillometric Method (가압식 오실로메트릭 방법을 사용한 혈압측정 시스템의 설계)

  • 노동곤;이윤선;지정호;박성빈;이계형;김해관
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.281-286
    • /
    • 2003
  • Blood Pressure is one of the most fundamental Parameters which reflects physical conditions medically and the blood pressure measurement system using oscillometric method is a Non-Invasive Blood Pressure measurement device by measuring arterial Pressure through a cuff. In this paper. we designed a inflatable wrist blood pressure system which measures blood Pressure during the stepping inflation in the wrist cuff. The hardware system consists of a main power unit, a bladder in cuff unit, signal detection units, signal Processing units. a wireless data transmission unit, and a data display unit. We evaluated the reliability of this system by comparing and analyzing systolic. diastolic blood Pressure, and heart rate with other commercial blood Pressure measurement devices. Characteristic ratio values used to determine systolic and diastolic blood Pressure using MAA(Maximum Amplitude Algorithm) were 0.436 and 0.671 respectively.