• Title/Summary/Keyword: 속도검정장치

Search Result 11, Processing Time 0.031 seconds

An Analysis of Pedestrians' Speed according to Pedestrian Countdown Signal Systems (보행신호 잔여시간 표시장치에 따른 보행속도 분석)

  • Jang, Myeong-Sun;Im, Sam-Jin;Kim, Gyeong-Hui
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.4 s.90
    • /
    • pp.43-53
    • /
    • 2006
  • Pedestrian countdown signals were newly introduced to make Pedestrians feel more comfortable and safer in crossing the streets This Paper analysed pedestrian walking-speed through a before-after behavior study Data was collected from 22 sites. and the total number of pedestrians was 19,800. The results showed that the average Pedestrian walking-speed of existing pedestrian signal, an inverted triangle countdown signal and a numeric countdown signal were 1.44, 1.39 and 1.42m/sec. The difference between the three methods was statistically significant. The results showed that the distribution of the walking-speed of existing signal. an inverted triangle countdown signal and a numeric countdown signal were statistically Erlang(0.117, 10) distribution. Weibull(1.17, 3.72) distribution and Gamma(0.137, 8.18) distribution at 95% confidence level.

A Comparison Between the Tape Switch Sensor and the Video Images Frame Analysis Method on the Speed Measurement of Vehicle (차량 속도 측정의 실무적용을 위한 테이프스위치 센서 방식과 영상 프레임 분석방법의 비교연구)

  • Kim Man-Bae;Hyun Cheol-Seung;Yoo Sung-Jun;Hong You-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.9 s.351
    • /
    • pp.120-127
    • /
    • 2006
  • In Korea the vehicle enforcement system(VES) detects speeding vehicle using two inductive loop detectors. And the speed reliability of theirs are evaluated through the analysis of image frame which is captured from video camera. This method is validated to evaluate VES on Korea Laboratory Accreditation Scheme(KOLAS) but it needs much time and expense for the analysis of image frame. Because the number of VES are increasing rapidly, the requirement of new evaluation method is necessary. On this paper, the tape switch sensor as a substitution of existing method was introduced and its application on the site are discussed. On the site test we compared the tape switch sensor on the speed measurement of vehicle with the video image frame. As a result we have founded that the tape switch sensor is evaluated to be feasible system on site in respect to measure the overspeed vehicle.

The Effects of Virtual Reality-based Exercise on Energy Expenditure during Gait in Chronic Stroke Patients (가상현실을 이용한 재활운동이 뇌졸중 환자의 보행시 에너지 소모에 미치는 효과)

  • Lee, Dong-Yeop;Shin, Won-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3826-3832
    • /
    • 2010
  • This study was aimed at determining the effect of virtual reality(VR) based exercise programs on energy expenditure during gait in chronic stroke patients. Thirty-two stroke patients were participated for this study. They underwent stroke for more than 6 months and were assigned to a VR-exercise group (n=16) or a control group (n=16). The VR-exercise group executed a rehabilitation exercise three times a week during 6 weeks. The VR-exercise was performed by PS2 for one hour. Control group maintained their usual life without application of exercise. Energy expenditure index(EEI) during gait was calculated from heart rate and gait velocity. After the completion of the VR-exercise, the EEI was decreased significantly (p<0.05). These results showed that the rehabilitation exercise using a virtual reality is effective in the improvement of energy efficiency during gait in chronic stroke patients.

Determination of Rare Earth Elements by Inductively Coupled Plasma Mass Spectrometry with Introduction of Organic Phase Using Ultrasonic Nebulizer (초음파 분무기를 이용한 유기상의 주입에 의한 희토류 원소의 유도결합 플라스마 질량분석법적 정량)

  • Lee, Sang Hak;Son, Bum Mok
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.127-134
    • /
    • 2002
  • Analytical method to determine rare earth elements which were extracted to organic phase by inductively coupled plasma mass spectrometry(ICP-MS) was investigated. Organic phase which had extracted rare earth elements was directly aspirated into ICP-MS by ultrasonic nebulizer(USN) in order to reduce solvent load to the plasma. Then, the count rate increased when MIBK(methyl isobutyl ketone) was added to EtOH(ethanol) but decreased when 0.03 M HEH(2-ethylhexyl-2-ethylhexyl phosphonic acid, $P_{507}$, PC88A) was added to solvent which mixed MIBK with EtOH. The optimal temperatures of desolvation system were -10 $^{\circ}C$ for the condenser and 150 $^{\circ}C$ for the heating tube. The optimal nebulizer flow rate which gave maximum count rate and minimum reflect power was 0.7 L/min. The optimal pH and extraction time were 4.3 and 10 min for MIBK-0.03 M HEH system. Detection limits which were obtained through calibration curves at the range of 0.2 ${\sim}$ 20 ng/mL were 0.02 ${\sim}$ 0.05 ng/mL under the optimal experimental conditions.

Thin Layer Drying Model of Black Soybean (검은콩의 박층건조모델)

  • Lee, S.K.;Kim, H.;Kim, W.;Jeon, M.J.;Byun, J.S.;Han, J.W.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.99-99
    • /
    • 2017
  • 국내 콩의 소비량은 계속적으로 증가하고 있다. 재배 면적은 1995년 10,000ha에서 2013년 8,000ha까지 계속적으로 감소하였으며, 수입은 2009년 644.9백만 달러에서 2013년 883.3백만 달러까지 계속적인 증가 추세에 있다. 건조는 품질 손상을 최소화 및 수분을 제거하는 공정이다. 모든 곡물에는 건조 조건에 따라서 품질이 크게 변화하며, 건조 과정을 해석하여 해당 곡물의 적정 건조 조건을 구명하여 품질을 유지하는 위해서는 중요하다(Keum, 등 1977). 얇은 두께의 곡물층을 단층으로 하여 건조속도 및 건조공기의 조건을 나타내는 것을 박층(Thin layer)건조모델이라 한다. 박층건조모델을 계속적으로 쌓은 모델을 후층(Deep layer)모델이라 하며, 건조기 개발 및 건조조건 구명에 가장 기본이 된다(Basunia and Abe, 1998). 그러나 해외에서 만들어진 콩 박층건조 모델은 국내의 검은콩과 물성이 상이하여 건조조건이 다르게 설정 되어야 한다. 따라서, 본 연구목적은 건조온도 2수준, 상대습도 3수준에 대하여 검은 콩의 건조속도 측정하고, 곡물건조방정식으로 많이 이용되고 있는 4개의 건조방정식에 대하여 모델 적합성을 검정하여 검은콩 건조에 적합한 박층건조모델 결정하는데 있다. 공시재료는 2015년 강원도지역에서 생산된 검은콩을 실험에 사용하였으며, 초기 함수율은 14.7%,w.b.였다. 박층 건조공기 조성은 공기조화장치(MTH4100, SANYO, UK)를 사용하여 조성하였으며, 송풍기에 의해 공기충만실을 통과하여 건조 층을 통과하도록 구성하였다. 목표 평형함수율에 도달하면 실험을 종료하였다. 건조 층의 초기중량 및 경시적 변화는 전자저울(GF-4000, AND, Japan)을 이용하여 10분 간격 측정하여 저장하였다. 적정 박층건조모델을 결정하기 위하여 기존의 곡물건조방정식 중 널리 사용되고 있는 4개(Lewis, 1921; Page, 1949; Thompson, 1967; Moisture diffusion, 1975)의 건조모델을 이용하여 비교 검증하였다. 건조 초기 2시간 까지는 급격히 감소하다가 건조속도에 영향을 미치는 반건조시간(MR=0.5) 이후에는 완만하게 건조되는 것으로 나타났고 건조조건으로 건조온도 및 상대습도 모두의 영향이 미치는 것으로 나타났다. 4가지 건조 모델과 비교한 결과 Thompson 모델이 전체 건조 영역에서 비교적 잘 일치하였다.

  • PDF

Determination of Glucose in Whole Blood by Chemiluminescence Method (화학발광법에 의한 전혈 중의 당 정량)

  • Lee, Sang Hak;Choi, Sang Seob
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.3
    • /
    • pp.223-229
    • /
    • 2001
  • A method for the determination of glucose in human whole blood by chemiluminescence method using a stopped flow injection system has been studied. The method is based on the differences in the chemiluminescence intensities of luminol due to the different amounts of hydrogen peroxide produced from the glucose oxidase catalyzed reaction. The enzyme reactor was prepared by immobilization of glucose oxidase on aminopropyl glass beads and the chemiluminescence from a flow cell was measured by means of an optical fiber bundle. In order to obtain the optimum experimental conditions, effects of pH for the chemiluminogenic solution and enzyme reactor, flow rate and temperature on the chemiluminescence intensity were investigated. The calibration curve obtained under optimum experimental conditions was linear over the range from $1.0{\times}10^{-1}$ mM to 7.0 mM and the detection limit was $6.0{\times}10^{-2}$ mM. The proposed method was applied to the determination of glucose in whole human blood sample and the results were compared with those obtained by an official method. The present method was also evaluated by the results of recovery experiments.

  • PDF

Clinical Effects of an Improved Pump Reaction Rate and Automatic Occlusion Sensing System in Phacoemulsification (수정체유화장치의 초음파 출력속도 및 자동막힘감지 기능 향상의 술 후 임상결과 비교)

  • Kim, You Na;Lee, Jin Ah;Kim, Jae Yong;Kim, Myoung Joon;Tchah, Hung Won
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1017-1023
    • /
    • 2018
  • Purpose: A recently introduced phacoemulsification system, the WhiteStar $Signature^{(R)}$ PRO, has demonstrated improved nucleus followability and cutting efficiency via an improved pump regulator with a higher reaction response and an automatic occlusion sensing system. In this study, we compared various phacoemulsification parameters between the new system and an older version of the device. Methods: A total of 80 eyes of 68 patients with cataracts who had undergone phacoemulsification by a single surgeon were included in this study. Forty eyes of patients underwent phacoemulsification using the older $Signature^{(R)}$ system (WhiteStar); these patients were classified as the control group. Another 40 eyes of patients underwent phacoemulsification with the newer enhanced system, the WhiteStar $Signature^{(R)}$ PRO; these patients were assigned to the experimental group. During the operation, operative parameters, including the effective phaco time (parameter of effective phaco time with a specific coefficient for the transversal movement expressed in seconds, EFX), ultrasound time (seconds [s]), effective phacoemulsification time (EPT, s), average phacoemulsification power (AVG, %), and balanced salt solution usage, were measured to determine the performance enhancement offered by the updated system. Central corneal thickness was measured before and after surgery to compare corneal edema. The relationships between the two groups were analyzed using an independent t-test. Results: The Signature $PRO^{(R)}$ system showed a lower EFX (p < 0.001), a shorter EPT (p < 0.001), and a smaller AVG (p < 0.001). Postoperative corneal thickness did not differ significantly between the two groups. Conclusions: Comparing the efficacy of the improved reaction speed of the device and automatic occlusion sensing system in performing phacoemulsification, the updated Signature $PRO^{(R)}$ system demonstrated superior followability and cutting efficiency regardless of nuclear cataract hardness.

Pesticide Degradation Activity of Several Isolates of Soil Bacteria and Their Identification (토양에서 분리한 수종 세균의 농약분해력 검정 및 동정)

  • Park, Kyung-Hun;Lee, Young-Kee;Lee, Su-Heon;Park, Byung-Jun;Kim, Chan-Sub;Choi, Ju-Hyeon;Uhm, Jae-Youl
    • The Korean Journal of Pesticide Science
    • /
    • v.10 no.2
    • /
    • pp.138-148
    • /
    • 2006
  • Two bacteria were isolated from the continuously pesticide-used soil under plastic film house and upland condition. The degradation test of several pesticides by the selected bacteria, B59 and B71, were conducted. The degradation rates for 6 pesticides, procymidone, chlorothalonil, ethoprophos parathior, alachlor and pendimethalin, in medium by the isolates were 21.1% to 53.2% higher than non-inoculated medium. Under shaking culture condition, 90% to 95% of procymidone was degraded after 21 days treatment. Parathion was degraded in the range of 60% to 100% by B71 and B59, respectively. Otherwise 70% of alachlor was degraded by the two isolated bacteria during same period. The pH was not significantly affected for degradation of pesticides. The bacterial strains, B59 and B71 was identified as Acinetobacter sp. and as Pseudomonas sp. based on morphological, biochemical and physiological characteristics, and identity and similarity of automatic identification system, Biolog and MIDI.

COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL (모형 레진 근관에서 수종의 전동 니켈-티타늄 파일에 대한 screw-in effect 비교)

  • Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.267-272
    • /
    • 2010
  • Screw-in effect is one of the unintended phenomena that occurs during the root canal preparation with nickel-titanium rotary files. The aim of this study was to compare the screw-in effect among various nickel-titanium rotary file systems. Six different nickel-titanium rotary instruments (ISO 20/.06 taper) were used: $K3^{TM}$ (SybronEndo, Glendora, CA, USA), $M_{two}$ (VDW GmbH, Munchen, Germany), NRT with safe-tip and with active tip (Mani Inc., Shioya-gun, Japan), ProFile$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland). For ProTaper$^{(R)}$, S2 was selected because it has size 20. Root canal instrumentations were done in sixty simulated single-curved resin root canals with a rotational speed of 300 rpm and single pecking motion. A special device was designed to measure the force of screw-in effect. A dynamometer of the device recorded the screw-in force during simulated canal preparation and the recorded data was stored in a computer with designed software (LCV-USE-VS, Lorenz Messtechnik GmbH, Alfdorf, Germany). The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. P value of less than 0.05 was regarded significant. ProTaper$^{(R)}$ produced significantly more screw-in effects than any other instruments in the study (p < 0.001). $K3^{TM}$ produced significantly more screw-in effects than $M_{two}$, and ProFile$^{(R)}$ (p < 0.001). There was no significant difference among $M_{two}$, NRT, and ProFile$^{(R)}$ (p > 0.05), and between NRT with active tip and NRT with safe one neither (p > 0.05). From the result of the present study, it was concluded, therefore, that there seems significant differences of screw-in effect among the tested nickel-titanium rotary instruments. The radial lands and rake angle of nickel-titanium rotary instrument might be the cause of the difference.

Influence of taper on the screw-in effect of nickel-titanium rotary files in simulated resin root canal (모형 레진근관에서 니켈-티타늄 전동 파일의 경사도가 screw-in effect에 미치는 영향)

  • Sung, Hye-Jin;Ha, Jung-Hong;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.380-386
    • /
    • 2010
  • Objectives: The introduction of nickel-titanium alloy endodontic instruments has greatly simplified shaping the root canal systems. However, these new instruments have several unexpected disadvantages. One of these is tendency to screw into the canal. In this study, the influence of taper on the screw-in effect of the Ni-Ti rotary instrument were evaluated. Materials and Methods: A total of 20 simulated root canals with an S-shaped curvature in clear resin blocks were divided into two groups. ProFile .02, .04, .06 (Dentsply-Maillefer) and GT rotary files .08, .10, .12 (Dentsply) were used in Profile group, and K3 .04, .06, .08, .10, and .12 (SybronEndo, Glendora) were used in K3 group. Files were used with a single pecking motion at a constant speed of 300 rpm. A special device was made to measure the force of screw-in effect. A dynamometer of the device recorded the screwin force during simulated canal preparation and the recorded data was stored in computer with designed software. The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. p value of less than 0.05 was regarded significant. Results: The more tapered instruments generated more screw-in forces in Profile group (p < 0.05). In K3 group, 0.08, 0.10. and 0.12 tapered instruments showed more screw-in force than 0.04 tapered one, and 0.08 and 0.12 tapered instruments showed more screw-in force than 0.06 tapered one (p < 0.05). Conclusions: The more tapered instruments seems to produce more screw-in force. To avoid this screw-in force during instrumentation, more attention may be needed when using more tapered instruments.