• Title/Summary/Keyword: 소형콘

Search Result 38, Processing Time 0.018 seconds

Study on the Measurement of Liquid Limit Using a Penetration Resistance of Small Cone in Clay Soil (소형콘의 관입저항력을 이용한 점토의 액성한계측정에 관한 연구)

  • Son, Moorak;Lee, Jaeyong
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.10
    • /
    • pp.5-15
    • /
    • 2016
  • This study investigated both water content and penetration resistance of small cone of various clay soils that were made of Kaolinite and Bentonite with different mixing ratios and compared the results with those of the existing dynamic (Casagrande test) and static (fall cone test) tests directly. The comparison showed that the water content at the inflection point on a curve of water content and penetration resistance was very similar to the liquid limit from a fall cone test. The penetration resistance of small cone at the inflection point was 0.2 kPa, and it was ascertained that the water content at the inflection point represents a liquid limit of clay soils. From the study results, it was found that the penetration resistance of 0.2 kPa with the small cone can be an indicator of the liquid limit of clay soils in practice. Finally a test procedure to measure the liquid limit of clay soil based on a penetration resistance of small cone was proposed.

Development of Miniature Cone and Characteristics of Cone Tip Resistance in Centrifuge Model Tests (원심모형실험용 소형 콘 개발 및 콘 선단저항치 특성에 관한 연구)

  • Kim, Jae Hyun;Kim, Dong Joon;Kim, Dong Soo;Choo, Yun Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.631-642
    • /
    • 2013
  • The standard CPT(Cone Penetration Test), which can be easily performed to investigate in-situ soil engineering properties, has been widely used. CPT are also widely being utilized in centrifuge model tests. In this study, a miniature cone with 10mm diameter was developed and its applicability in the centrifuge was evaluated. The developed miniature cone was equipped with a four degree-of-freedom in-flight robot. A series of cone penetration tests was performed under four centrifuge acceleration levels. As results, the cone resistances measured at the same confining stress within shallow penetration depth were affected by the centrifugal accelerations. The critical depth was proportional to the cone diameter and relative density. Cone resistances results below the critical depth and soil parameters obtained from the laboratory tests were compared with those by previously proposed empirical relations.

Study of Temperature Compensation method in Mini-Cones (소형 콘의 온도보상 기법 연구)

  • Yoon, Hyung-Koo;Jung, Soon-Hyuck;Cho, Se-Hyun;Lee, Jong-Sub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1C
    • /
    • pp.29-38
    • /
    • 2011
  • The smaller diameter cone penetrometer has been widely used to estimate the characteristics of local area due to high vertical resolution. The half-bridge cirucits have been adopted to measure the mechnical strength of soil through the smaller diameter cone penetrometer due to the limitation of the areas for configuring the full-bridge circuit. The half-bridge circuit, however, is known as being easily affected to the temperature variation. The objective of this study suggests the temperature-compensated method in mini-cones. The diameter and length of the mini-cone is designed to 15mm and 56mm. The load cell of the mini-cone is extended about 54mm on the behind of the mini-cone to reflect the only temperature variation. The full-bridge circuit is installed to measure the temperature-compensated values in the mini-cone and the half-bridge circuit is also organized to compare the temperature compensated values with uncompensated values. The seasonal variation tests are performed to define the effect of temperature variation under summer and winter temperature condition. The densification tests are also carried out to investigate temperature effects during penetration. The measured mechanical resistances with temperature-compensated method show more reliable and reasonable values than those measured by thermal uncompensated system. This study suggests that the temperature-compensated method of the mini-cone may be a useful technique to obtain the more reliable resistances with minimizing the temperature effect.

Scale Effects and Field Applications for Continuous Intrusion Miniature Cone Penetrometer (연속관입형 소형콘관입시험기에 대한 크기효과 및 현장적용)

  • Yoon, Sungsoo;Kim, Kyu-Sun;Lee, Jin Hyung;Shin, Dong-Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2359-2368
    • /
    • 2013
  • Cone penetration tests (CPTs) have been increasingly used for site characterizations. However, the site investigations using CPTs are often limited due to soil conditions depending on the cone size and capacity of the CPT system. The small sectional area of a miniature cone improves the applicability of the CPT system due to the increased capacity of the CPT system. A continuous intrusion system using a coiled rod allows fast and cost effective site investigation. In this study, the performance of the continuous intrusion miniature cone penetration test (CIMCPT) system has been evaluated by comparison tests with the standard CPT system at several construction sites in Korea. The results show that the CIMCPT system has a same performance with the CPT system and has advantages on the mobility and applicability. According to field verification tests for scale effect evaluation, the cone tip resistance evaluated by CIMCPT overestimates by 10% comparing to standard CPTs. A crawler mounted with the CIMCPT system has been implemented to improve accessibility to soft ground, and has shown improvement over the truck type CIMCPT system. Therefore, the improved CIMCPT system can be utilized as a cost effective and highly reliable soil investigation methodology to detect the depth of soft ground and to evaluate soil classification.

Determination of Undrained Shear Strength using Miniature Cone and T-bar Penetrometers for Kaolin Clay (소형콘과 T-bar 관입기를 이용한 카올린 점토의 비배수전단강도 산정에 관한 연구)

  • Sespene, Shemelyn;Choo, Yun Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.429-438
    • /
    • 2018
  • Cone and T-bar penetrometers have been frequently used to estimate the undrained shear strength of clay. For small-size model tests, miniature penetrometers should be used but their correlation factors have not been well published. In this study, a testing setup was developed to derive empirical factors of the miniature cone and T-bar penetrometers. A 350mm-diameter chamber and kaolin clay were utilized to prepare soil specimens consolidated under four different pre-consolidation pressures controlling undrained shear strength. Two miniature cones with two diameters of 10-mm and 16-mm and a T-bar penetrometer with 10-mm diameter were used to investigate boundary effect, penetration rate effect, and diameter and shape effect. Unconsolidated-undrained triaxial tests were carried out with samples taken from the specimens to measure undrained shear strength. Finally, empirical factors for the penetrometers were constructed to correlate tip resistance to undrained shear strength.

A Study on the Field Application of a Small Dynamic Cone Penetration Tester Using Hammer Automatic Strike and Penetration Measurement (해머 타격과 관입량 측정이 자동화된 소형 동적콘관입시험기의 현장 적용성 연구)

  • Hwiyoung Chae ;Soondal Kwon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.12
    • /
    • pp.5-11
    • /
    • 2023
  • Economic damage is occurring due to landslides and debris flows that occur when the ground artificially created for roads or photovoltaic power generation facilities is weakened by rainfall such as torrential rain. In order to understand the stability of the artificially created ground, it is very important to check the ground information such as the compositional state and mechanical characteristics of the stratum. However, since most of the investigation sites are steep slopes or there are no access roads, it is not easy to enter the drilling equipment commonly used to check ground information and perform standard penetration tests. In this study, a dynamic cone penetration test (DCP) device using a miniaturized auger drilling equipment and an automatic drop device was developed to check the cone resistance value and the dynamic cone penetration test value and analyze the correlation with the standard penetration test value to confirm its applicability at the mountain solar power generation site. As a result, the cone resistance value is qd = 0.46 N and the dynamic cone penetration test value is Nd = 1.58 N, confirming a value similar to the results of existing researchers to secure its reliability.

Cone resistance and electrical resistivity with Depth at Dredged Sea Sand Region (준설해사로 다짐된 방조제 제체 성토부의 콘저항치와 전기비저항 관계)

  • Song, Sung-Ho;Kang, Mi-Kyung
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.37-40
    • /
    • 2008
  • We have measured resistivities for undisturbed soil samples collected from dredged bank with sea sand, and analyzed with one-dimensional inversion results from small-loop electromagnetic survey data. From the relationship between the two resistivities, it appeared that calculated resistivities were remarkably consistent with measured resistivities. Correlation relationships between resistivity values and cone resistance were analyzed after comparing inversion results with cone resistance. It turns out that the region with below 1 ohm-m is correspondent to that of with less than $50\;kgf/cm^2$ in dredged bank with sea sand. From the study result, resistivity monitoring of small-loop EM periodically is proved to be more effective to maintain the stability of embankment dike.

  • PDF

Study on Shear Strength Using a Portable Dynamic Cone Penetration Test and Relationship between N-Nc (소형동적콘관입시험을 이용한 전단강도 산정 및 N-Nc 상관관계 연구)

  • Kim, Hyukho;Lim, Heuidae
    • Economic and Environmental Geology
    • /
    • v.50 no.2
    • /
    • pp.145-157
    • /
    • 2017
  • Because of Recent intensive rainfall, nationally landslides and slope failure phenomenon has been frequently occur. Providing proposed-measures to the natural disasters that occur in these localities and the slope, must be derived ground of strength parameters(shear strength) as a design input data. However, it is such as extra deforestation and a lot of economic costs in order to make the access to the current area and the slopes ground survey is required. Thus, by small dynamic cone penetration test machine using the human to carry in the field, it is possible to easily measure the characteristics and strength constant of the ground of more than one region. In this study through researching analysis of the domestic and foreign small dynamic cone penetration test method, it has proposed a cone material and test methods suitable for the country. Cone penetration test Nc in the field has comparated with analysis of the value and the standard penetration test N value. And, in addition to this, direct shear test and borehole shear test were performed by depth, bedrock, and soil type and passing #200 and the correlation of the Nc value. In particular, in the present study, for the sandy soil that has distict distribute in mountain, it is proposed relation of shear strength corresponding to the Nc value (cohesion and internal friction angle) in order to calculate such effective ground shear strength.

Study on Establishing the Subgrade Compaction Control Methods Based on the In-situ Elastic Modulus (현장 탄성계수에 근거한 노상 다짐관리방안 연구)

  • Choi, Jun-Seong;Han, Jin-Seok;Kim, Jong-Min
    • International Journal of Highway Engineering
    • /
    • v.14 no.3
    • /
    • pp.49-58
    • /
    • 2012
  • In many countries including Korea, the design concept of pavement structure has been converted from empirical method to mechanisticempirical method since the advent of compaction control based on resilient modulus proposed by AASHTO in 1986. Studies of last decades indicates that the classical compaction control method based on relative compaction and plate bearing test(PBT) will necessarily move to the methods taking advantage of light falling weight deflectometer(LFWD) and dynamic cone penetrometer(DCP) in addition to PBT. In this study, the validity of resilient modulus prediction equation proposed by Korean Pavement Design Guide is verified by comparison with physical properties of subgrade soil and the results of structural analysis. In addition, correlational equations between elastic modulus measured by various field tests and resilient modulus estimated by empirical model are proposed. Finally, a field test-based compaction control procedure for subgrade is suggested by using proposed correlational equations.

精密計測 에 利용되는 센서 (II)

  • 한응교
    • Journal of the KSME
    • /
    • v.22 no.6
    • /
    • pp.424-433
    • /
    • 1982
  • 근년의 각종 센서의 발전은 급속히 측정기의 성능향상을 가져왔다. 즉 전출감도의 향상, 변환률의 향상, 소형화, 응답성의 향상, 신뢰성의 향상등이다. 더욱이 이들의 뛰어난 자동화와 마이콘의 적극적인 활용에 의해 계측의 자동화를 지향하고 있는 것이 많다. 이하에 설명하는 것은 소제 목으로한 측정에 포함되는 센서를 전부 망라한 것은 아니고 구래의 것과 대비하여 독자적인 것을 각각 예시한 것이다.

  • PDF