• Title/Summary/Keyword: 소자 결함

Search Result 2,472, Processing Time 0.032 seconds

Influence to the Doppler Images by the Defects of SAE in the Probe of Medical Ultrasonic Scanners (초음파 프로브에서 인접 단위 소자군(SAE) 결함이 도플러 영상에 미치는 영향)

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.7-15
    • /
    • 2015
  • A ultrasonic probe is very important in medical ultrasonic image, but the frequency of probe defects are often. Therefore practical tools for probe based ultrasonic QA should be developed. Advanced research on the effects of the probe defects on the quality of ultrasonic images is required. This study has investigated the effects of the defects in the probe elements influence Doppler images in the medical ultrasonic scanners. Especially the defects in a set of adjacent elements(SAE) electrically disconnected influence Doppler images were tested. The results show Doppler brightness and velocity became rapidly reduced as the defected elements is located centrally, as the defected elements is activated. The more the defected elements increased, the more Doppler brightness and velocity increased. As a set of the element disconnected moved, it appeared Doppler velocity starting to decrease and then was followed by brightness. The strength is not consistent with the velocity in the number and location of the defected elements. The defects in the probe elements influence Doppler velocity when the defected elements got out of the elements activated at Doppler mode.

BTS 측정 분석을 통한 MLCC 소자의 결함 여부 판단

  • Choe, Pyeong-Ho;Kim, Sang-Seop;Choe, Byeong-Deok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.298-298
    • /
    • 2012
  • 본 연구에서는 Bias Temperature Stress (BTS) 측정을 통한 다층세라믹커패시터(Multi-Layer Ceramic Capacitor, MLCC) 소자 분석에 대한 연구를 진행하였다. BTS 분석은 소자 내부에 존재하는 Na+, K+ 등의 mobile charge 검출을 위한 방법으로 positive bias와 negative bias stress에 따른 C-V 특성 곡선으로부터 mobile charge의 정량적 해석이 가능하다. 실험 결과 positive bias stress 후의 C-V 특성 곡선이 stress 전 C-V 특성 곡선과 비교해 negative bias 영역으로 0.0376 V 만큼 shift 하였다. 또한 수식(QM = $Cox{\cdot}{\triangle}V$)으로부터 $1.7{\times}1,011$개의 mobile charge가 존재함을 확인하였다. 본 연구는 MLCC 소자 내의 금속 오염물 존재 여부에 따른 소자의 전기적 특성 변화 분석을 위해 진행되었으며, BTS 분석은 반도체 소자 뿐 아니라 본 연구에서와 같이 커패시터 소자의 결함 여부 판단에도 이용 가능함을 확인하였다.

  • PDF

Influence to the Doppler Images by the Defects of Piezoelectric Elements of the Probe of Medical Ultrasonic Scanners (Focusing on the Impact of an Increase in the Defects of Piezoelectric Elements) (초음파 프로브 소자 결함이 도플러 영상에 미치는 영향 (소자 결함 증가에 따른 영향을 중심으로))

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.117-124
    • /
    • 2014
  • This study has investigated the effects of the defects in the probe elements influence Doppler images in the medical ultrasonic scanners. This work was implemented that the quality of Doppler images depended on the extent and location of the probe element defected. The probe performance was rated in terms of the number of piezoelectric elements lost and this was studied in the experiment by electrical disconnection to the elements. The results showed that Doppler velocity became rapidly reduced as the defected elements encountered with the element group activated at the Doppler mode, not as the flow velocity. The effect of the probe defect is decreased when the defects occurred at the element group activated for Doppler mode, as was increased the number of the elements. It was observed that the higher the flow velocity of Doppler flow phantom is, the wider the spectrum of Doppler is. And the Doppler velocity soared up and the dispersion of image brightness is increased when the defected elements got out of the elements activated at Doppler mode. The result showed that TADVP(time-average-Doppler-velocity-profile) is decreased with the increase of the probe element defect, especilly in the region of high frequency. It is expected that the research of various defects of probe elements are needed, and this study can be practical tools for probe based ultrasonic QA in the future.

박막 두께변화에 따른 ZnO 저항 메모리소자의 특성 변화

  • Gang, Yun-Hui;Choe, Ji-Hyeok;Lee, Tae-Il;Myeong, Jae-Min
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.28.1-28.1
    • /
    • 2011
  • 비휘발성 저항 메모리소자인 ReRAM은 간단한 소자구조와 빠른 동작특성을 나타내며 고집적화에 유리하기 때문에 차세대 메모리소자로써 각광받고 있다. 현재, 이성분계 산화물, 페로브스카이트 산화물, 고체 전해질 물질, 유기재료 등을 응용한 저항메모리소자 응용에 대한 연구가 활발히 진행되고 있다. 그 중 ZnO 박막은 이성분계 산화물로써 조성비가 간단하고, 빠른 동작특성을 나타내며, 높은 저항 변화율을 보이기 때문에 ReRAM에 응용 가능한 재료로써 기대되고 있다. 또한 가시광선 영역에서 광학적으로 투명한 특성을 보이기 때문에 투명소자 응용에도 많은 연구가 진행되고 있다. 본 연구에서는 Metal/Insulator/Metal (Al/ZnO/Al) 구조의 소자를 제작하여 저항 메모리 특성을 평가하였다. Radio frequency (RF) sputter를 이용하여 ZnO 박막을 합성하고 박막의 결정성을 평가하였으며, resistive switching 효과를 관찰하였다. 합성된 박막 내부의 결정성은 메모리 구동 저항에 영향을 주며, 이를 제어하여 신뢰성있는 메모리 효과를 얻을 수 있었다. 특히 박막의 두께를 제어함으로써 구동전압의 변화를 관찰하였으며 소자에 적합한 두께를 평가할 수 있었다. 또한, ZnO 박막 내의 결함에 따른 on/off 저항의 변화를 관찰할 수 있었다. 제작된 저항 메모리소자는 unipolar 특성을 보였으며, 높은 on/off 저항의 차이를 유지하였다. Scanning electron microscope(SEM)을 통해 합성된 박막의 형태를 평가하였고, X-ray diffraction (XRD) 및 transmission electron microscopy (TEM)을 통해 결정성을 평가하였으며, photoluminescence (PL) spectra 분석을 통하여 박막 내부의 결함 정도를 평가하였다. 제작된 소자의 전기적 특성은 HP-4145를 이용하여 측정하고 비교 분석하였다.

  • PDF

The Impacts of Piezoelectric Elements' Defects On Color & Power Doppler Images (초음파 프로브에서 소자결함이 컬러 및 파워 도플러 영상에 미치는 영향)

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.443-449
    • /
    • 2015
  • An ultrasound probe has a big impact on Doppler images even though it has very high risk of frequent function-breakdowns occurring in medical ultrasound scanners. This study experimentally analyses the impacts of an ultrasonic probe's defected elements on power & color Doppler images. The results show that, the bigger the size of defected probe elements is, and the closer a group of action elements is to the center, the more the brightness of images and the velocity of Doppler diminish. When elements' defects increase in color & power Doppler images, false images are formed to be mistaken for blood-vessel plaque in neighboring regions. Accordingly, whenever element defects are suspected, we need check-up process in B-mode. From this respective, it is advisable to have primary interest in a probe and carry out continuous probe QA for ultrasonography.

나노공정기반 광소자 기술개발 현황

  • 정명영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.10-10
    • /
    • 2004
  • 유전율이 서로 다른 물질을 나노 크기로 주기적으로 배열하여 황자 띠간격(Photonic bandgap)을 이루게 하는 광결정(Photonic crystal)에 인위적인 결함을 부가하여 광파워 분배 및 Mux/Demux 등 광회로 기능 수행을 할 수 있도록 집적화한 광도파로 소자가 미래형 정보통신사회를 위한 초고집적화, 초고속화, 저전력 및 신기능 등의 특성을 위하여 요구된다. 이러한 나노 광결정 소자는 다양한 방법으로 제작이 시도되고 있는데, 나노 임프린트 기술은 실장밀도가 높으며, 수십 나노급의 패턴이 주기적으로 배열된 구조물의 성형에 큰 장점이 있어서 본 연구에서 다루어졌다.(중략)

  • PDF

A Study on Fault Diagnosis for Planar Active Phased Array Antenna (평면 능동위상배열안테나 결함소자 진단방법에 관한 연구)

  • Jin-Woo Jung;Seung-Ho Kang
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.1
    • /
    • pp.11-22
    • /
    • 2023
  • A radiating elements fault diagnosis method with simplified radiation pattern measurement procedure was presented for planar active phased array antenna system. For presenting the mentioned method, the technique for linear approximation based on the radiation characteristics of a planar array configuration and a technique for solving a unique solution problem that occur in process of diagnosing a fault in a radiating elements were presented. Based on the presented method and a genetic algorithm, experimental simulations were performed for radiating element defect diagnosis according to various planar active phased array antenna configurations. As a result, it was confirmed that the presented radiating element fault diagnosis method can be smoothly applied to planar active phased antennas having various configurations.

A study on the Measurement Algorithm for the Ball Height of BGA Device Using Stereo Vision (스테레오 비젼을 이용한 BGA 소자의 볼 높이 측정 알고리즘에 관한 연구)

  • Kim, Joon-Seek;Park, Young-Soon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.26-34
    • /
    • 2006
  • In this paper, We proposed he algorithm for defect extraction and a study of the stereo image modeling o inspect defect for the ball height of BGA(ball grid way) device using 2-dimensional images captured by the BGA device of using the high resolution CCD cameras. This paper propose the package/ball area extraction of BGA device part, the FOV(field of view) calibration part, the top point matching part, and ball height measurement method. Each BGA device propose extraction method by defect, Through the experiment, we verified the result.

OLED 소자의 열화현상에 따른 휘도 효율 특성평가

  • Choe, Seong-Ho;Lee, Gyeong-Su;Choe, Byeong-Deok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.246-246
    • /
    • 2012
  • 최근의 디스플레이 시장에서는 고효율 저전력, 자발광 소자인 OLED가 차세대 디스플레이 시장의 블루칩으로써 연구되고 개선되어 왔다. 고효율, 고휘도 구현이 가능한 OLED 소자는 초기 발광 시 수명감소, 저전류 구동 효율 개선 및 소자의 유기 재료 개선의 문제점에 직면해 있기 때문에 많은 가능성을 아직 현실화 하지 못하고 있다. 본 연구에서는 전기적 스트레스를 가한 OLED 소자의 전기적, 광학적 성질을 측정함으로써 열화에 따른 소자의 특성 변화를 확인하여 문제점을 개선하는데 기여하고자 한다. $2{\times}2$ inch Glass에 $2{\times}2$ mm 크기의 발광면적을 갖는 Red OLED 소자를 제작한 후 Source Measure Unit을 이용, 8 V의 과전압을 72시간 동안 인가하여 소자의 열화현상을 가속시켰다. 이후 I-V-L 장비를 이용하여 전기적 특성 및 휘도 특성을 측정하였다. 측정된 결과는 휘도가 8 V에서 10,620 cd/$m^2$ > 9,849 cd/$m^2$ (약 7.2% 감소)로 변화한 것을 확인 하였으며, 휘도 효율과 전력 효율을 측정해본 결과 8 V 에서의 소비전력 효율 역시 16%에서 > 15%로(약 1%감소) 변화하였으나 안정적으로 발광이 유지되는 3 V~6 V 구간에서는 효율이 약 13%가 감소하였다. 또한 휘도 효율은 8 V 기준으로 1% , 3 V~6 V 구간에서는 약 8% 감소하였다. 본 연구 결과를 통하여 OLED 소자의 열화 현상은 소자의 휘도 감소뿐만 아니라 소비전력증가, 열화현상의 촉진으로 이어지는 것으로 확인 되었다.

  • PDF

Optimization of Chromatographic Separation of Lysozyme from Homogenate of Hen Egg White by Comparison of Breakthrough Behavior (파과분석(Breakthrough behavior) 비교에 의한 난백으로부터 라이소자임 크로마토그래피 분리 최적화)

  • 김원경;정봉현
    • KSBB Journal
    • /
    • v.14 no.3
    • /
    • pp.279-283
    • /
    • 1999
  • We have compared the breakthrough behavior of lysozyme contained in fresh han egg white on various cation exchagers, and the adsorbent, known by the trade name Cellufine C-200 (Amicon), has shown the best performance. The effects of ion strength, pH, and linear flow rate on the breakthrough behavior were examined using the Cellufine C-200 adsorbent. The optimal conductivity, pH and linear flow rate were determined from the breakthrough behavior and found to be 2.75 mS/cm, 7.0, and 0.635 cm/min, respectively.

  • PDF