• Title/Summary/Keyword: 소음차단

Search Result 173, Processing Time 0.024 seconds

Examination for Structural Safety of Floating Slab Design and Shear Connector (플로팅 슬래브 설계와 전단연결재의 구조안전성 검토)

  • Park, Sung-Jae;Ma, Chang-Nam;Lee, Jong-Ho;Lee, Du-Hwa
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.374-374
    • /
    • 2011
  • Recently the construction of railway sections passing the central area of cities and stations under railway lines are increasing, and then it is urgently required to take the countermeasures against the railway vibration and the second-phase noise radiated from it. The most efficient countermeasure, out of technologies developed up to now, is the floating slab track which is the track system isolated from the sub-structure by springs. In other countries, the source technologies for anti-vibration design and vibration isolator - one of key components - have been developed and many installation experiences have been accumulated. However, in Korea, since the system design technology and technologies for key components are not yet developed, the foreign system are being introduced without any adjustment, and the key component, vibration isolator, depends on imports. In this study, based on the results of previous studies of the dust-control device installation using the slab and go through time after lifting impressive when stepped on power generated by the cross-section of the slab and shear connection re-examined the structural stability.

  • PDF

A Stdy on Clutch-disc Torsional Characteristics for Torsional Vibration Reduction at Idling (공회전시 비틀림 진동 저감을 위한 클러치 비틀림 특성 연구)

  • 홍동표;정태진;김상수;태신호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.04a
    • /
    • pp.82-87
    • /
    • 1994
  • 자동차 엔진의 주기적인 연소과정 동아네 생성된 힘에 의해 엔진의 크랭크 샤프트에 회전 불균일성이 나타난다. 이것은 엔진 플라이휘일 부분에 비틀림 변동토크를 발생시키고, 이 토크는 클러치를 통하여 변속기의 인풋기어(input gear)에 전달되어 변속기에 비틀림 진동을 일으키는 주요 원인이 된다. 공회전시 변속기에서 기어의 충돌은 주로 이 비틀림 변동토크에 의해 발생하며, 이 충돌은 차내 소음의 원인이 된다. 또한 엔진의 경량화 및 고출력화에 따른 회전수 변동의 증가는 비틀림 변동토크를 증가시켜 변속기에 커다란 진동을 초래한다. 시뮬레이션을 사용한 클러치 비틀림 기구의 적절한 특성치를 구하는 것은 클러치 설계에 효율적이고, 이미 여러 연구 결과들이 보고되었다. H.Arai은 2자유도 비선형 모델을 사용하여 클러치 접속시 발생하는 외란과 계의 안정성을 고려하여 치타음 저감을 위한 시뮬레이션을 수행하였고, S.Ohnuma은 비선형 2단 비틀림 특성을 가진 클러치 디스크의 설계에 대해서, 그리고, T.Fujimoto와 R.J.Comparin는 치타음의 발생구조와 특성을 고찰하고 비선형 비틀림 공진 저감에 의한 치타음 저감 기법에 대하여 연구하였다. 그리고, Wu Hui-Le는 자동차 동력전달계의 비틀림 진동 현상을 실험과 이론적인 계산을 통해 연구하였고, G.J.Fudala는 다자유도 모델을 이용하여 클러치의 비틀림 특성에 따라 주파수분석을 수행하여 치타음 저감 방법을 연구하였다. 또한, T.Sakai는 5자유도 모델을 이용하여 엔진 공회전시 발생하는 치타음에 대해 이론과 실험을 통해 해석하고, 엔진 회전수 변동, 클러치 특성, 변속기의 드래그(drag) 토크의 영향과 치타음 저감을 위한 개선된 클러치 특성을 제시하였다. 클러치는 동력을 전달 또는 차단하는 기능 뿐만 아니라 엔진이나 변속기에서 발생하는 소음이나 진동을 저감시키는 기능을 가지고 있다. 따라서 엔진 공회전시에 발생하는 치타음(rattle noise)이나 비틀림 진동을 저감시키는 방법으로는 여러가지가 있으나 클러치 디스크(clutch disc)의 비틀림 기구의 설계 인자들을 적절히 조절함으로써 변속기의 인풋기어에 전달되는 비틀림 진동을 저감시키는 방법이 일반적으로 수행되어지고 있다. 본 연구는 4 실린더 4 싸이클 1.5L 엔진을 장착한 경승용차의 실차실험을 통해 공회전시 엔진 플라이휘일과 인풋기어에서의 회전수 변동을 측정하고, 이 실험 데이타를 기초로 하여 엔진 토크 및 변속기에서의 드래그 토크를 계산하여 엔진-변속기 인풋기어의 반한정계 2자유도 진동모델과 비틀림 특성을 가진 클러치 디스크의 프리댐퍼 영역에 대해 시뮬레이션을 수행하여 클러치 비틀림 기구의 설계인자인 비틀림 강성, 히스테리시스 토크에 따른 비틀림 진동 저감 효과를 연구하고자 한다.

  • PDF

Consideration on Rating Method for Heavy Impact Sound Taking Account of the Characteristics of Floor Vibration and Impact Sources (바닥 진동 거동 및 충격원 특성을 고려한 바닥 중량 충격음 평가방법 고찰)

  • Lee, Min-Jung;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.69-79
    • /
    • 2017
  • The purpose of this study is to reconsider the rating method for the floor impact sound insulation performance in current criterion. Although there are some arguments about proper standard heavy impact source with reproducibility of actual impact source in residence building, bang machine is adopted as the only standard heavy impact source in domestic criterion. To inspect the rating methods of evaluation criteria, this study conducted vibration test for both of standard heavy impact sources and actual impact sources. Using the test results, the floor impact sound insulation performance levels were assessed by each of several criteria. In addition, low frequency noise beyond current criteria was evaluated. Consequently, the floor impact sound levels have different performance levels according to adopted criteria, and measured floor impact sounds are bound to annoy the neighbors in the low frequency range. Current criteria does not consider the spectrum characteristics of floor impact sound according to impact sources and low frequency noise. This may cause the difference between the floor impact sound insulation performance level and human perception. Thus current criterion needs to be complemented to reflect the spectrum characteristics of floor impact sound levels according to impact sources and sound pressure levels in low frequency range.

New Mount with Moving-Coil-Type Electromagnetic Actuator for Naval Shipboard Equipment (가동코일형 전자기식 작동기를 결합한 함정 탑재장비용 마운트 개발)

  • Shin, Y.H.;Moon, S.J.;Jung, W.J.;Jeon, J.J.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.10
    • /
    • pp.885-894
    • /
    • 2013
  • In this study, a new hybrid mount with a moving-coil-type electromagnetic actuator is developed to reduce the vibration transmitted from naval shipboard equipment to the ship hull structure. The detailed design of the hybrid mount is determined through several design stages with electromagnetic numerical analysis using Maxwell software. The hybrid mount, which combines a rubber mount with an electromagnetic actuator, has a fail-safe function for shock resistance. The mount is fabricated and tested using a universal testing machine to check the design specifications. Finally, control tests are carried out on the hybrid mount to confirm its performance and applicability.

Comparison of Impact Sound Insulation Performances of Apartment Floors Against Heavy-weight Impact Sources via Field Measurement Data (공동주택 현장 측정자료를 활용한 중량충격원의 바닥충격음 차단성능 비교)

  • Yun, Chang-Yeon;Yeon, Jun-Oh;Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.8
    • /
    • pp.651-658
    • /
    • 2014
  • Notification 2013-611 of MOLIT has come into effect. It relates primarily to new standard impact source. In this study, an in-depth experimental analysis of the difference between a bang machine and an impact ball was performed via field testing of shear wall and flat plate structure at 51 sites. This paper focuses on the difference in single number quantities between a bang machine and an impact ball. At wall thicknesses of 180 and 210 mm in shear wall structure, the single number quantities exhibited differences of 3.1 and 4.5 dB, respectively, and at thicknesses exceeding 250 mm in flat plate structure, the difference was constant at 4.6 dB. With regard to flat plate structures, the single-index difference increased up to 11 dB as the thickness of the floor slab increased. In general, the highest level of contribution for the bang machine was 63 Hz, irrespective of thickness determining bandwidth. The highest level for the impact ball were 63 Hz and 125 Hz. In future research, when reviewing additional field performance measurement data, it will be necessary to consider a detailed examination instead of the current method of uniformly adding 3 dB for all thicknesses and types of structures.

Comparison of the Effect of Music and Noise Blocking on Postoperative Pain, Length of Stay at Post Anesthetic Care Unit and Satisfaction after a Laparoscopic Colectomy (음악요법과 소음차단요법이 수술 후 통증, 진통제 투여량, 회복실 체류시간 및 만족도에 미치는 효과 비교)

  • Seo, Eunju;Yoon, Haesang
    • Journal of Korean Biological Nursing Science
    • /
    • v.17 no.4
    • /
    • pp.315-323
    • /
    • 2015
  • Purpose: This study compared the effect of music and noise blocking on the vital signs, postoperative pain, analgesic use, length of stay in the Post Anesthesia Care Unit (PACU) and satisfaction after a laparoscopic colectomy. Methods: This randomized controlled trial was performed in a 555-bed National Cancer Center, from February 13 through May 31, 2012. Subjects consisted of 69 patients who underwent a laparoscopic colectomy under general anesthesia, and were recruited by informed notices. The inclusion criteria were patients between the ages of 35-75, with an American Society Anesthesiologist physical classification I or II. The subjects were randomly allocated to three groups; music therapy group (MTG), noise blocking group (NBG) and control group (CG). Collected data were analyzed using Repeated measures ANOVA, one-way ANOVA and Kruskal-Wallis test through IBM SPSS (Version 19.0). Results: There were no significant differences in vital signs among the three groups. Postoperative pain in MTG (p<.05) and NBG (p<.05) was significantly decreased compared to CG. The amount of analgesics (p=.030) and length of stay at PACU (p=.021) in MTG was significantly decreased compared to NBG or CG; satisfaction in MTG and NBG was significantly higher compared to CG. Conclusion: Music seems to reduce postoperative pain, the amount of analgesics, and the length of stay at PACU. Therefore, music therapy is considered to be included in nursing intervention for postoperative patients at PACU.

Crime Prevention by Using CPTED and Improvement (환경설계를 통한 범죄예방 및 개선방안)

  • Park, Kwang-Hyun
    • Journal of Digital Contents Society
    • /
    • v.18 no.4
    • /
    • pp.733-738
    • /
    • 2017
  • This study is to find out empirically how the fear of crime is affected by the level of recognition of people. CPTED elements including natural surveillance, access control, utilization enhancement, territoriality securement, etc. Safety of residents could be considered and then increased when we plan, design, and operate a city. In Korea, CPTED is currently being applied to every town. However, it is not systemized and neither efficient, for there are no constraint provisions, and the foreign cases are not specifically customized to the current situation of the country. This study, therefore, aims to find the limits from analyzing related laws and regimes, administrative regulations, and applied cases, and to deduct improvement plans based on examined foreign cases.

Acoustic insertion loss by a bubble layer for the application to air bubble curtain and air masker (기포층 음향 삽입손실 연구: 기포커튼과 에어마스커)

  • Park, Cheolsoo;Jeong, So Won;Kim, Gun Do;Moon, Ilsung;Yim, Geuntae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.4
    • /
    • pp.227-236
    • /
    • 2020
  • This paper derives the insertion loss for the bubble layer of an air bubble curtain and an air masker which are used to reduce ocean anthropogenic noise such as the piling noise and the ship noise. The air bubble curtain is considered as a 'fluid-air bubble layer-fluid' model and the environment for the air masker is simplified as an 'vacuum-thin plate-fluid-air bubble layer-fluid' model. The air bubble layer in each model is assumed as the effective medium which has the complex wavenumber and the complex impedance corresponding to the bubble population distribution. The numerical simulations are performed to examine the insertion loss depending on the bubble population, the void fraction, and the thickness of the layer.

Analysis of Shear Behavior of Reinforced ALWAC Beam Using Interface Elements (계면요소를 이용한 경량철근콘크리트 보의 전단거동해석)

  • Rhee, Inkyu;Kim, Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.107-115
    • /
    • 2006
  • A challenging topic was and still is the failure behavior of concrete beams without shear reinforcement. In spite of substantial experimental and theoretical efforts in the past, the mechanism of shear failure is not entirely understood. ALWAC is of importance to the current construction industry. Most of present concrete research focuses on high performance concrete, by which in meant a cost effective material that satisfies demanding performance requirements, including durability. The advantages of ALWAC are its reduced mass and improved thermal and acoustic insulation properties, while maintaining adequate strength. In spite of these advantages, its ultimate failure behavior has not been well defined for adequate design process. This paper will investigate mainly the shear behavior of reinforced ALWAC beam without web reinforcements numerically with experimental evidences.

Unsteady Wind Pressure Analysis on PSD Considering Subway Station Configurations (지하철 역사 형상을 고려한 PSD 비정상 풍압해석)

  • Kim, Yu-Sung;Kim, Yo-Han;Shin, Kwang-Bok;Lee, Eun-Kyu;Kim, Dong-Hyun
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2008
  • In this study, unsteady wind pressure analyses on platform screen door (PSD) have been conducted considering the flow intereference effects between the moving train and the configuration of subway station. The major role of PSD prevents passenger accidents, wind pressure, polluted dust and noise when the train is entering the station platform. Computational fluid dynamic method with moving gird algorithm has been adopted to accurately predict unsteady pressure levels exerted on the PSD. Closed and open type station configuration are considered. Also, wind pressure levels for passing and stopping drive motion of the entering train are presented and practically compared each other.