• Title/Summary/Keyword: 소음감소대책

Search Result 30, Processing Time 0.027 seconds

A Study on Noise Reduction of Quiet Pavement through the Noise Level Prediction and the Economic Analysis (저소음 포장의 소음예측 및 경제성 분석을 통한 소음 저감방안)

  • Jo, Shin Haeng;Jang, Jung Soon;Kim, Wan Sang;Kim, Nakseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1143-1151
    • /
    • 2013
  • Reasonable methods are needed to predict the noise level of new/existing roads and to select means of noise reduction. In this study, the noise reduction effects of both soundproof walls and quiet pavements were predicted. The noise reduction effects of quiet pavements were predicted by measurement data obtained using the CPX method in test pavements. The noise reduction effect was predicted by KHTN program when applied to soundproof walls and quiet pavement. As a result, the predicted noise level was similar to the measured one. The design method was suggested by an economic analysis using noise benefit of predicted noise reduction. The research suggests that the optimum alternative has to be determined using noise prediction method and life-cycle cost analysis.

An experimental research on the heating characteristics and the elimination of noise in electric ondol for off-peak storage use (축열형 전기온돌의 난방특성과 진동소음 제거에 관한 실험적 연구)

  • 현경호;오명환;채성기
    • 전기의세계
    • /
    • v.22 no.2
    • /
    • pp.75-86
    • /
    • 1973
  • 본 연구에서는 전기온돌의 안방열손실을 감소시키고 축열효과를 향상시키기 위한 방법을 검토하였으며 전기온돌에서 발생하는 진동소음을 감살시킬 수 있는 대책을 제시하였다. 저육들은 6.6[m$^{2}$] 크기의 전기온돌 model을 이용하여 건물의 구조차이와 하향열단열층의 설치유무에 따른 보온특성의 차이를 기록분석하였으며 그 결과 열전도계수가 0.03[kcal/m.hr.deg. C]정도인 내열성 Styropol과 지석 Mortar로 구성된 하향열단열층을 전기온돌의 마닥에 설치할 경우 난방부하의 감소로 인하여 축열효율이 약 2배나 향상된다는 결론을 얻었다. 또한 전기온돌공사시에 발열선을 지지할 수 있는 대각선형 Spacer를 설치하고 발열선이 매설콘크리트가 완전히 양생된 이후에 전력을 인가하면 흔히 전기온돌에서 발생하는 120-960[Hz]의 가청진동소음을 방지할 수 있다는 사실을 실험적으로 확인하였다.

  • PDF

Vibration Control of Press for soundproof barrier (타공형 방음벽 프레스의 방진대책)

  • 정정교;박진일;박해동;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.656-661
    • /
    • 2001
  • 생산 현장의 진동환경은 부품생산활동과 관련된 공정변수중 대표적인 것으로 기계 부품 생산의 품질 및 생산품의 불량률에 큰 영향을 미치며 또한 주변으로 전파된 진동은 우수한 진동환경을 요하는 다른 생산장비에 나쁜 영향을 미치기도 한다. 본 연구의 대상은 공장의 이전으로 인한 환경변화에 의해 발생한 타공형 방음벽 생산 프레스의 진동을 제어하기 위해 바닥의 진동가속도 레벨을 측정하고 DIN 5140에 제시된 기준에 적합하도록 방진 시스템을 설계하였으며 그 결과 방진전과 비교하여 약 20 ㏈ 가량의 바닥 진동 가속도 레벨이 감소하였다.

  • PDF

Investigation of the surface treatment method for silent pavement in tunnels (터널 내 주행소음 저감을 위한 포장표면처리공법에 관한 조사연구)

  • Park, Tae-Soon;Ko, Seok-Beam
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.4
    • /
    • pp.371-388
    • /
    • 2003
  • The tunnels that longer than 2km which have been recently constructed have serious noise problems resulting from the friction of vehicle wheels and pavement. In special, concrete pavement inside tunnels with a closed characteristic increases discomfort due to the traffic noise and the dust of pavement pollutes the air in tunnels. Therefore, it is urgent that we find out ways to cope with. This study purported to reduce noise inside tunnels covers the investigation of various pavement surface treatment methods adapted in developed countries, the analysis of the effect in noise reduction and construction methods and cases. The surface treatment method for silent pavement in tunnels reduced noise to 5dB (A)~10dB (A). Aggregate treatment method is evaluated the most appropriate method in that, related with other surface treatment method, it reduces noise and improves skid resistance. It is necessary for us to introduce equipments and design and rearrange of specification for the development of the silent pavement method in Korea.

  • PDF

Analysis of Traffic Noise for Single and Double Layered Porous Pavement with SPB Method -National Route 1, Sejong-Si Section- (SPB측정법에 의한 복층 및 단층 다공성포장의 소음분석 -국도 1호선 세종시 구간-)

  • Yoo, In-Kyoon;Lee, Su-Hyung;Han, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.92-102
    • /
    • 2020
  • Porous pavement (PP) has attracted attention as a new alternative measure against road traffic noise. PP refers to pavement that reduces the fines in the asphalt mixture to form voids. These voids can reduce traffic accidents and friction noise. For active application, verification of the noise reduction effect is required. In this study, the noise reduction of single-layer PP(SLPP) and double layer PP(DLPP) was analyzed. First, the Sejong section was selected, and traffic noise was measured using the SPB method on the roadside. The traffic volume, speed, and mixing ratio of large vehicles were measured. As a result, the DLPP was evaluated to be 7.95 dB(A) smaller on average and 7.57dB(A) smaller at the 95% reliability level than the SLPP. The traffic volume was more influential than the speed and the mixing rate of large vehicles. As the traffic volume increased, the noise increased, but the difference in noise between the two pavements decreased gradually. The results showed that the most effective way to reduce road traffic noise is to change the road pavement rather than reduce traffic speed, restrict traffic for heavy vehicles, or reduce traffic volume.

Environmental Pollution in Korea and Its Control (우리나라의 환경오염 현황과 그 대책)

  • 윤명조
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.5-6
    • /
    • 1972
  • Noise and air pollution, which accompany the development of industry and the increase of population, contribute to the deterioration of urban environment. The air pollution level of Seoul has gradually increased and the city residents are suffering from a high pollution of noise. If no measures were taken against pollution, the amount of emission of pollutant into air would be 36.7 thousand tons per year per square kilometer in 1975, three times more than that of 1970, and it would be the same level as that of United States in 1968. The main sources of air pollution in Seoul are the exhaust has from vehicles and the combustion of bunker-C oil for heating purpose. Thus, it is urgent that an exhaust gas cleaner should be instaled to every car and the fuel substituted by less sulfur-contained-oil to prevent the pollution. Transportation noise (vehicular noise and train noise) is the main component of urban noise problem. The average noise level in downtown area is about 75㏈ with maximum of 85㏈ and the vehicular homing was checked 100㏈ up and down. Therefore, the reduction of the number of bus-stop the strict regulation of homing in downtown area and a better maintenance of car should be an effective measures against noise pollution in urban areas. Within the distance of 200 metres from railroad, the train noise exceeds the limit specified by the pollution control law in Korea. Especially, the level of noise and steam-whistle of train as measured by the ISO evaluation can adversely affect the community activities of residents. To prevent environmental destruction, many developed countries have taken more positive action against worsening pollution and such an action is now urgently required in this country.

  • PDF

Characteristics of noise generated during treatment in dental clinic

  • Choi, Mi-Suk;Ji, Dong-Ha
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.5
    • /
    • pp.181-188
    • /
    • 2022
  • In this paper, we proposed of the results of the noise level and appropriate conversation distance by applying the noise characteristics generated during treatment at a dental clinic to the NR-curve and PSIL. As a result of analyzing the noise characteristics during treatment at a dental clinic, it was analyzed that the noise level exceeded 60dB(A), which is the health preservation limit value caused by noise, and the noise level increased as the frequency increased. the result of evaluation applying it to the NR curve, some treatment exceeded the workplace noise standard, and as a result of analyzing the level of conversational disturbance between the worker and the patient, it is desirable to have the conversation at a distance of less than 1M for accurate communication. In order to improve the quality of medical service in dental clinic and to reduce dental fear, it is judged that soundproofing protective equipment is provided to workers, and soundproofing measures are needed for noise sources (treatment devices used in treatment) and sound sources (patients and workers).

Marine Environmental Impact Assessment on the Construction of Solar Plant near Shrimp Farms (새우양식장인근 태양광공사에 따른 소음저감방안연구)

  • Oh, Hyun-Taik;Kim, Yeong-Tae;Tac, Dae-Ho;Lee, Dae-In;Kim, Gi-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.2
    • /
    • pp.130-139
    • /
    • 2015
  • To assess the noise stress of shrimp farms reasonably, we need a noise observation data underneath the waters first. But, it did not collect yet and airborne noise transfers to water noise wave using transition calculation. In case of construction of solar energy without noise stress protection wall, the threshold values (140 dB) from circumstance of underwater noise exceed within 17m at $S_2$ (15m away from source) and $S_3$ (15m away from source). Considering additional way to decrease the construction noise, all cases including minimum mode(Case A), general mode(Case B), and maximum mode(Case C) meet the guideline of underwater noise for fish farms. In case of the underwater noise could affect the fish farm, it is necessary to understand about farming species such as shrimp, monitoring of present states, and protection way under the construction.

The Noise Level Assessment of Dental Equipment (치과 의료장비의 소음 수준 평가)

  • Lee, Jeong-Suk;Han, Ye-Seul;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.603-611
    • /
    • 2015
  • This research is aimed at cutting off hearing loss and other harmful factors due to noise and providing basic material for noise reduction plan. As the research method, this research assessed noise by measuring acoustic pressure level and frequency in various situation of non-treatment and treatment. As the measurement result, average noise degree of high speed handpiece of non-treatment, ultrasonic waves scaler, and low speed handpiece showed 58~66 dB(A). Average noise degree of scaling of treatment, tooth elimination, and denture adjust showed 73~81 dB(A). The result is inferior to recognized standards of noise induced hearing loss. But the result of assessing this with (noise rating) NR curve was NR-73~78, which exceeded general workplace noise standard. This level can cause hearing loss when exposed to a long time. Therefore, treatment office noise during dental treatment can cause psychological and physical damage in dental clinic employees, and it is urgently required to establish systematic and active noise reduction plan.

Analysis of sound power level of high-noise construction machinery excavator (고소음 건설기계 굴삭기의 소음도 현황 분석)

  • Park, Hyung-Kyu;Jung, Joon Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.240-246
    • /
    • 2019
  • The noise generated by construction machinery operating at construction sites is a major cause of environmental disputes with nearby residents. To reduce construction site noise, low noise construction machinery and low noise methods are recommended to be used first. In addition, the possible noise should be predicted and preventive measures suitable for the noise source should be taken. This study analyzed the sound power level of an excavator, which is used most frequently at construction sites. The sound power level of 297 excavators sold in Korea after 2008 were analyzed and the sound power level was classified according to the type, output (kW), and production site of the excavator engine based on the measured data. As a result, the sound power level decreased by 1 dBA depending on the change in engine type and the sound power level increased by approximately 3 dB (A) when the engine output was doubled. In addition, the sound power level was low in small-sized products of less than 55 kW for overseas products and medium and small-sized products of 55 to 104 kW for domestic products.