Influence of Stack Effect in High-Rise Buildings on Wind Effect in Jeju (Comparative Analysis of Seoul and Jeju) (제주지역 고층건축물에서의 바람의 영향이 굴뚝효과에 미치는 영향 분석 (서울과 제주지역간의 비교 분석))

  • Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.6-12
    • /
    • 2015
  • This study used CONTAM modeling to analyzed analyze the stack effect in high-rise buildings for the terrain and weather conditions of Seoul and Jeju. The differential pressure caused by the stack effect is a function of the indoor and outdoor temperature difference and the height of the vertical shaft. Jeju is considered more stable than Seoul, because it is warmer than Seoul in winter. The differential pressure in Jeju is about 60% that of Seoul in for the same height of buildings in winter. However, Jeju is an island and the neutral plane is raised by over 56% by strong winds, although there is less differential pressure caused by the stack effect in Jeju than in Seoul. Due to the raised neutral plane, the region and magnitude of negative pressure in the lower part is larger in Jeju than in Seoul.

A Sensitivity Study of the Number of Parcels to the Numerical Simulation of Sprinkler Sprays (통계적 액적군집수에 따른 스프링클러 분무해석의 민감도에 관한 연구)

  • Kim, Sung-Chan;Lee, Sang-Woo;Park, Won-Ju
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.48-54
    • /
    • 2009
  • The present study has been performed to investigate the effect of statistical number of droplets on the simulation of the sprinkler spray using fire field model. In order to simulate the sprinkler spray characteristics, the present study uses NIST Fire Dynamics Simulator version 5.2. A group of Lagrangian particles with similar droplet characteristics, such as diameter, velocity, temperature and so on, is represented by parcel concept to decrease the total number of droplets tracked in the simulation. The present study introduces a new parameter to represent the ratio between real number of droplets and computational parcels. The dependency of the number of parcels on the fire suppression characteristics and spray patterns is quantitatively examined for different ratio between the real number of droplets and computational parcels.

Assessment of the Usefulness of the Water Spray for Fire Extinguishing in Case of Fire in Tunnels (터널 화재시 수분무 소화설비의 효용성 평가)

  • Rie, Dong-Ho;Lim, Kyung-Bum;Yoo, Ji-Oh
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.55-60
    • /
    • 2008
  • In this study, we conducted an FDS numerical simulation for the purpose of carrying out a basic assessment of the usefulness of the water spray for fire extinguishing. We analyzed the effect of securing the stability in temperature and smoke density in case of fire according to fire intensities (20MW, 50MW) and changes in wind speed. When there was no wind speed in tunnels, it was effective in securing the safety of people because the cooling effect of the water spray system had an excellent effect on reducing temperatures and smoke densities there. The higher a fire intensity is, the less effect it has on reducing smoke flows. When an air current exists in tunnels, its cooling effect disturbs the smoke stratification and lowers the visibility degree during evacuation. Therefore, the water spray for fire extinguishing should be put into action only after people take shelter during fire.

Performance Evaluation of a Natural Smoke Ventilator in Jeju (배연창의 개방층 설정방식에 따른 배연성능 평가 연구(제주지역 중심으로))

  • Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.6-11
    • /
    • 2016
  • This study analyzed the performance of smoke exhaustion installed to secure the life safety from the smoke each opening modes, as performing the simulation on the Jeju regions generating to strong windy using CONTAM. We assessed the effectiveness of the system under conditions of high external winds as well as an ambient wind conditions. It also assessed the relative effectiveness of opening all vents versus opening only those vents which served rooms in which the fire was located. This study revealed external winds exerted a substantial impact on the performance of the smoke ventilation system. It was found that opening the ventilation system in the room containing the fire resulted in a greater performance than opening vents in both fire in all rooms. The reduced performance of the smoke ventilation system upon the opening of all vents is thought to be due to the intrusion of outside air, and the establishment of unfavorable air circulation, caused by the negative pressure generated in the building.

A Study on the Fire Characteristics of Palletized Unit-Load Commodities on Racks (랙크 내 파렛트단위 적재물품의 화재특성에 관한 연구)

  • Cho, Gyu-Hwan;Yeo, In-Hwan
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.23-30
    • /
    • 2016
  • A fire extinguishing system for a rack warehouse was recently designed, which only consider the gross area and number of stories. However, the design of such a system should take into account not only the planar structuree, but also the elevation perspectives due to its vertical structure. Moreover, the fire load of the commodities palletized on the racks should be considered, in order to design a performance-based fire safety system that is appropriate for these environmental conditions. For this reason, this study analyzed the fire characteristics of the commodities palletized on the racks (pallet + the commodities in a box unit + vinyl packing material), taking into consideration the results of a field investigation conducted in Korea, as well as the Hazard Classifications of Commodities used in other countries. Through this analysis, the heat release rate (HRR) and smoke production rate (SPR) were derived.

Experimental and Numerical Study of the Thermal Decomposition of an Epoxy-based Intumescent Coating (실험과 계산을 통한 에폭시 계열 내화도료의 열분해에 관한 연구)

  • Kim, Yangkyun
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • This study investigates the characteristics of thermal decomposition of an epoxy-based intumescent paint using thermogravimetric analysis (TGA) and numerical simulation. A mathematical and numerical model is introduced to describe mass loss profiles of the epoxy-based intumescent coating induced by the thermal decomposition process. The decomposition scheme covers a range of complexity by employing simplified 4-step sequential reactions to describe the simultaneous thermal decomposition processes. The reaction rates are expressed by the Arrhenius law, and reaction parameters are optimized to fit the degradation behavior seen during thermogravimetric (TG) experiments. The experimental results show a major 2-step degradation under nitrogen and a 3-step degradation in an air environment. The experiment also shows that oxygen takes part in the stabilization of the intumescent coating between 200 and $500^{\circ}C$. The simulation results show that the proposed model effectively predicts the experimental mass loss as a function of time except for temperatures above $800^{\circ}C$, which were intentionally not included in the model. The maximum error in the simulation was less than 3%.

CCDP Evaluation of the Eire Areas in NPP Applying CEAST Model (II) (화재모델 CFAST를 이용한 원전 화재구역의 CCDP평가(II))

  • Lee Yoon-Hwan;Yang Joon-Eon;Kim Jong-Hoon;Kim Woon-Byung
    • Fire Science and Engineering
    • /
    • v.19 no.3 s.59
    • /
    • pp.20-27
    • /
    • 2005
  • This paper evaluates the fire safety level of eight pump rooms in the nuclear power plant using a fire model, CFAST We estimate the Conditional Core Damage Probability (CCDP) of each room based on the analyzed results of CFAST Eight rooms located on the primary auxiliary building of the nuclear power plant are high pressure safety injection pump room A/B, low pressure safety injection pump room Am. containment sprdy pump room A/B, and motor-driven auxiliary feed water pump room A/B. The upper layer gas temperature of each room is estimated and the integrity of cable is reviewed. Based on the results, the integrity of the cable located at the upper part of compartment is maintained without thermal damage. The Conditional Core Damage Probability Is reduced to half of the old values. Accordingly, the fire safety assessment for eight pump rooms using the fire model will be capable of reducing the uncertainty and to develop a more realistic model.

A study on the assessment of wildland fire hazard through statistic examination and calorie analysis according to the geographical distribution of vegetation (통계적 고찰과 수목분포에 따른 열량분석을 통한 산림화재 위험성 평가에 관한 연구)

  • 김광일;김동현
    • Fire Science and Engineering
    • /
    • v.14 no.3
    • /
    • pp.27-32
    • /
    • 2000
  • The assessment of wildland fire hazard is the first priority to be considered in the prevention, extinction and control of wildland fire. For the standard to measure wildland fire hazard, the wildland fire Warning System is currently being used in Korea which computes the wildland fire occurrence hazard index through a stick weight to moisture conversion formula. It shows the risk of fuel substance being exposed to fire by meteorological factors. For a comprehensive assessment of wildland fire hazards by area, the major factors'hazards need to be measured and the assessment of wildland fire needs to be conducted through historical statistic examination. Therefore, the wildland (ire outbreak frequency and its seriousness of damage are analyzed through historical statistic examination to conduct the assessment of a wildland fire hazard, and then the calorific value of a forest is analyzed through differential scanning calorimeter measurement which assesses the comparative calorific hazard according to the geographical distribution of vegetation.

  • PDF

A Study on the Flame Retardant Performance of MDF Wood According to Flame Retardant Treatment Method (방염처리 방법에 따른 MDF 목재의 방염성능에 관한 연구)

  • Cha, Jung-Min;Hyun, Seong-Ho;Kim, In-Beom;Yoon, Myung-O
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.146-155
    • /
    • 2011
  • In the study, test was carried out to compare the flame retardant performance for the specimen of MDF wood to which field flame retardant treatment (post processing flame retardant) is applied, which is coated with flame retardant film of 5 companies, locally distributed, and MDF wood (nontreated, flame retardant film non-coated) to which aqueous or oil-based fire-retardant paint is applied. As a result of combustion test of MDF wood which was coated with flame retardant film of 5 companies, 2 products showed suitable values in 4 criteria, but other 3 products showed 10~40 % disqualification rate. In regard of characteristics of fire-retardant paint, oil-based fire-retardant paint is better than aqueous fire-retardant paint in flame retardant performance criteria, but MDF wood to which oilbase fire-retardant paint was applied was shown to have higher toxicity index grade than MDF wood to which aqueous fire-retardant paint was applied relatively.

The Research of the Analysis of Movement from a Fire using RTLS System (RTLS 시스템을 활용한 화재시 행동분석 연구)

  • Lim, Kyung-Bum;Kim, Ha-Young;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.98-103
    • /
    • 2010
  • The design disaster prevention of first consideration is security for the people in the buildings. However, it is difficult to make a project for considering variable cases, declined visibility of smoke, distance from another person, mentality, knowledge of clearway etc. This study purpose is, analysis variable cases and modularization of pattern movement to practice basic information for evacuation of simulation which is used RTLS (Real Time Location System) system. It is useful to sense the electric waves from the Tag and grasp the real-time position. The pattern movement of evacuation were analyzed prescription eyeglasses which is used RTLS system to consider following 3 actions; analysis of relations that declined visibility effect the decline of movement velocity, analysis rate of flow with the size of door to estimate the optimum size of door in building and analysis the pattern movement that a bottleneck situation with abundant of people passed together to these exit. The confirmed of propriety of the interpretation about the actual people to evacuate is expected applying the numerical formula in various situation.