• Title/Summary/Keyword: 소독공정

Search Result 123, Processing Time 0.041 seconds

The Implementation of a HACCP System through u-HACCP Application and the Verification of Microbial Quality Improvement in a Small Size Restaurant (소규모 외식업체용 IP-USN을 활용한 HACCP 시스템 적용 및 유효성 검증)

  • Lim, Tae-Hyeon;Choi, Jung-Hwa;Kang, Young-Jae;Kwak, Tong-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.3
    • /
    • pp.464-477
    • /
    • 2013
  • There is a great need to develop a training program proven to change behavior and improve knowledge. The purpose of this study was to evaluate employee hygiene knowledge, hygiene practice, and cleanliness, before and after HACCP system implementation at one small-size restaurant. The efficiency of the system was analyzed using time-temperature control after implementation of u-HACCP$^{(R)}$. The employee hygiene knowledge and practices showed a significant improvement (p<0.05) after HACCP system implementation. In non-heating processes, such as seasoned lettuce, controlling the sanitation of the cooking facility and the chlorination of raw ingredients were identified as the significant CCP. Sanitizing was an important CCP because total bacteria were reduced 2~4 log CFU/g after implementation of HACCP. In bean sprouts, microbial levels decreased from 4.20 logCFU/g to 3.26 logCFU/g. There were significant correlations between hygiene knowledge, practice, and microbiological contamination. First, personnel hygiene had a significant correlation with 'total food hygiene knowledge' scores (p<0.05). Second, total food hygiene practice scores had a significant correlation (p<0.05) with improved microbiological qualities of lettuce salad. Third, concerning the assessment of microbiological quality after 1 month, there were significant (p<0.05) improvements in times of heating, and the washing and division process. On the other hand, after 2 months, microbiological was maintained, although only two categories (division process and kitchen floor) were improved. This study also investigated time-temperature control by using ubiquitous sensor networks (USN) consisting of an ubi reader (CCP thermometer), an ubi manager (tablet PC), and application software (HACCP monitoring system). The result of the temperature control before and after USN showed better thermal management (accuracy, efficiency, consistency of time control). Based on the results, strict time-temperature control could be an effective method to prevent foodborne illness.

Evaluation Model of the Automation Level of Smart Water Treatment Plant (스마트 정수처리장의 자동화수준 평가모델)

  • Son, Sang Hyeok;Kim, Sun Woo;LEE, Jong Yun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.05a
    • /
    • pp.285-288
    • /
    • 2021
  • 4차 산업혁명의 출현과 함께 스마트공장, 스마트시티, 스마트러닝 등이 등장하면서 스마트 물관리시스템과 그 평가지표의 연구개발이 주요 사회문제로 대두되고 있다. 따라서 본 논문에서는 스마트 물 관리시스템의 자동화 수준 평가지표를 제안하고자 한다. 그 세부 연구내용은 다음과 같다. 첫째, 기존의 CMM과 SPICE 소프트웨어 프로세스 평가모델과 스마트공장의 평가지표를 검토하고, 스마트 정수처리장의 개념을 살펴본다. 둘째, 제안하는 스마트 물관리시스템의 평가지표에는 정수장의 주요 공정에 따라 착수 공정, 약품투입 공정, 혼화·응집 공정, 침전 공정, 여과 공정, 소독 공정의 6개 평가영역으로 세분화 하였고, 각 평가영역별로 0에서 4까지의 5단계 평가수준으로 구분하여 제안하였다.

전기분해수의 특성과 수산가공분야에의 응용

  • 어명희;김옥선;주동식;조순영
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2001.10a
    • /
    • pp.173-174
    • /
    • 2001
  • 최근 식품제조 및 유통과 관련하여 HACCP(위해요소분석과 중점관리)라는 새로운 개념의 도입으로 위생관리의 중요성이 더욱 고조되고 있다. 지금까지 제조 공정 중의 위생관리는 가열처리나 소독 살균이 주된 매체였으나, 위생 처리에 대한 현시점의 요구는 기존에 이용해오던 위생 대책을 획기적으로 대체할 만한 수단과 기술이 요구되고 있는 시점이다. (중략)

  • PDF

Comparative Study on Removal Characteristics of Disinfection By-products by Air Stripping and Flotation Processes (탈기와 부상 공정에 의한 소독부산물의 제거특성에 관한 비교 연구)

  • Cha, Hwa-Jeong;Won, Chan-Hee;Lee, Kang-Hag;Oh, Won-Kyu;Kwak, Dong-Heui
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.9
    • /
    • pp.513-520
    • /
    • 2016
  • It is well known that volatile compounds including disinfection by-products as well as emissive dissolved gas in water can be removed effectively by air stripping. The micro-bubbles of flotation unit are so tiny as microns while the diameter of fine bubbles applied to air stripping is ranged from hundreds to thousands of micrometer. Therefore, the micro-bubbles in flotation can supply very wide specific surface area to transfer volatile matters through gas-liquid boundary. In addition, long emission time also can be gained to emit the volatile compound owing to the slow rise velocity of micro-bubbles in the flotation tank. There was a significant difference of the THMs species removal efficiency between air stripping and flotation experiments in this study. Moreover, the results of comparative experiments on the removal characteristics of THMs between air stripping and flotation revealed that the mass transfer coefficient, $K_La$ showed obvious differences. To overcome the limit of low removal efficiency of dissolved volatile compounds such as THMs in flotation process, the operation range of bubble volume concentration is required to higher than the operation condition of conventional particle separation.

Development of Optimal Chlorination Model and Parameter Studies (최적 염소 소독 모형의 개발 및 파라미터 연구)

  • Kim, Joonhyun;Ahn, Sooyoung;Park, Minwoo
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.6
    • /
    • pp.403-413
    • /
    • 2020
  • A mathematical model comprised with eight simultaneous quasi-linear partial differential equations was suggested to provide optimal chlorination strategy. Upstream weighted finite element method was employed to construct multidimensional numerical code. The code was verified against measured concentrations in three type of reactors. Boundary conditions and reaction rate were calibrated for the sixteen cases of experimental results to regenerate the measured values. Eight reaction rate coefficients were estimated from the modeling result. The reaction rate coefficients were expressed in terms of pH and temperature. Automatic optimal algorithm was invented to estimate the reaction rate coefficients by minimizing the sum of squares of the numerical errors and combined with the model. In order to minimize the concentration of chlorine and pollutants at the final usage sites, a real-time predictive control system is imperative which can predict the water quality variables from the chlorine disinfection process at the water purification plant to the customer by means of a model and operate the disinfection process according to the influent water quality. This model can be used to build such a system in water treatment plants.

A Study on Removal of Disinfection By-products in High Concentration Powdered Activated Carbon Membrane Bio-reactor Process for Advanced Water Treatment (고도정수처리를 위한 HCPAC-MBR 공정에서의 소독부산물 저감에 관한 연구)

  • Lee, Song-Hee;Jang, Sung-Woo;Seo, Gyu-Tae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.27-34
    • /
    • 2006
  • This study was conducted to evaluate the performance of a membrane bioreactor filled with high concentration of powdered activated carbon (HCPAC-MBR) to reduce DBPs at the drinking water treatment. The pilot system was installed after the rapid sand filtration process whose plant was the conventional treatment process. The removal efficiencies of DBPs were measured during pilot operation period of 2 years. HAA and THM removal rates could be maintained around 80~90% without any troubles and then tremendous reduction of HAA and THM reactivity were observed more than 52%. The average removal rate of HAA formation potential (FP) and THM formation potential (FP) were 70.5% and 67.6% respectively. It is clear that the PAC membrane bioreactor is highly applicable for advanced water treatment to control DBPs.

Formation Characteristics and Control of Disinfection Byproducts in a Drinking Water Treatment Plant Using Lake Water (호소수를 원수로 사용하는 정수장의 소독부산물 생성 특성 및 제어 방안)

  • Lee, Kichang;Gegal, Bongchang;Choi, Ilhwan;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.5
    • /
    • pp.269-276
    • /
    • 2015
  • This study investigated the influence of characteristics of natural organic matter (NOM) on the formation of disinfection by-products (DBPs), and proposed the control strategies of DBPs formation in a drinking water treatment plant using lake water in Gyeongsangbuk-do. The fluorescence excitation-emission matrix analysis results revealed that the origins of NOM in raw waters to the plant were a mixture of terrestrial and microbial sources. Molecular size distributions and removals of NOM fractions were evaluated with a liquid chromatography-organic carbon detector (LC-OCD) analysis. Humic substances and low molecular weight organics were dominant fractions of NOM in the raw water. High molecular weight organics were relatively easier to remove through coagulation/precipitation than low molecular weight organics. The concentrations of DBPs formed by pre-chlorination increased through the treatment processes in regular sequence due to longer reaction time. Chloroform (74%) accounts for the largest part of trihalomethanes, followed by bromodichloromethane (22%) and dibromochloromethane (4%). Dichloroacetic acid (50%) and trichloroacetic acid (48%) were dominant species of haloacetic acids, and brominated species such as dibromoacetic acid (2%) were minimal or none. Dichloroacetonitrile (60%) accounts for the largest part of haloacetonitriles, followed by bromochloroacetonitrile (30%) and dibromoacetonitrile (10%). The formation of DBPs were reduced by 16~44% as dosages of pre-chlorine decreased. Dosages of pre-chlorine was more contributing to DBPs formation than variations of dissolved organic contents or water temperature.

Effect of Operating Parameters on Ozone Generation in Dielectric Barrier Discharge Process (무성방전내에서 오존 발생에 미치는 운전변수의 영향)

  • 이현돈;이은영;이용환;최유리;정재우
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.383-384
    • /
    • 2003
  • 오존은 산업적으로 널리 활용되고 있으며 특히, 매우 넓은 환경공학적 응용분야를 가지고 있다. 오존의 산업적 적용은 1900년대 초부터 음용수 처리를 위해 시작되었으며 현재까지 폐수처리, 화학물질 합성, 재료의 부식 정도 측정, 수영장 소독, 치료용 목적, 냉각수 살균, pulp bleaching, 악취 및 대기 오염물질 처리 등의 광범위한 산업적 응용분야를 가지고 있다. 오존을 생성시키기 위한 대표적인 공정으로는 무성방전(dielectric barrier discharge, DBD) 공정, 전기 분해법(electrolysis), 자외선 조사법(UV irradiation)을 들 수 있으며 가장 널리 활용되고 있는 공정은 1857년 Simens에 의해 개발된 DBD 공정이다. (중략)

  • PDF

Speciation of THMs, HAAs (THMs, HAAs의 종분포)

  • Kim, Jin-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.11
    • /
    • pp.1135-1140
    • /
    • 2006
  • Concentration and speciation of trihalomethanes(THMs) and haloacetic acids(HAAs) that can be created during chlorine disinfection as disinfection by-products(DBPs) in Korean water treatment plants(WTPs) were investigated. 4 WTPs that adopted conventional water treatment processes were chosen for investigation and each represented a typical WTP on the Han, Keum, Sumjin and Nakdong Rivers. The average concentration of THMs was 26.9 ppb, and the maximum and minimum concentrations were 47.6 ppb and 11.0 ppb respectively, while the average concentration of HAAs was 25.4 ppb, and the maximum and minimum concentrations were 57.1 ppb and 9.7 ppb respectively. DBPs concentration was lower in the winter than the summer. The major species of THMs was chloroform and its average percentage was 77%, and the second highest was bromodichloromethane(20%), while the concentration of bromoform was below detection limits. The sum of dichloroacetic acid(DCAA) and trichloroacetic acid(TCAA) was 97% of $HAA_5 $ on average base. But its percentage was 90% in the Han River WTP, especially it was the lowest during the winter. On the other hand, the concentration of DCAA was higher than TCAA except during the summer.

Establishment of Resilient Infrastructures for the Mitigation of an Urban Water Problem: 2. Robustness Assessment of Structural Alternatives for the Problems of Water Pollution (도시 물 문제 저감을 위한 회복탄력적 사회기반시설 구축: 2. 수질오염 문제 구조적 대안의 내구성 평가)

  • Jung, Jihyeun;Lee, Changmin;An, Jinsung;Kim, Jae Young;Choi, Yongju
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.3
    • /
    • pp.182-188
    • /
    • 2016
  • This study evaluated structural alternatives for managing water quality problems by reinterpreting and then applying the robustness-cost index (RCI) for urban flood problems. Cases of endogenous hormone pollution in treated sewage and proliferation of protozoa in intake-water were chosen as representative examples because they have different types of regulation standards for the treatment. Current facilities and structural alternatives with robustness indices (RIs) greater than unity were determined to be robust. The RI was combined with the cost index (CI) to obtain the RCI values. For the endogenous hormone pollution in treated sewage, a human-oriented estrogen $17{\beta}$-estradiol was selected as a target pollutant. The RI and RCI values for a structural alternative, extension of the current sewage treatment facility for advanced treatment, were greater than the values for the current practice of conventional activated sludge process. For the intake-water pollution by protozoa, UV and ozone disinfection facilities were evaluated for inactivation of Cryptosporidium parvum. The RCI values for ozone disinfection were greater than those for UV disinfection. Based on the results and the logics involved in the calculation of RCI for water quality issues we studied, we proposed procedures for establishing and implementing structural alternatives for the restoration from and prevention of outbreaks of water quality problems.