• Title/Summary/Keyword: 소각로 배가스

Search Result 20, Processing Time 0.023 seconds

A Study on the Entrance Region Fouling of Sludge Incinerator Air-preheater at IronWorks (제철슬러지 소각로의 공기예열기 입구의 파울링특성 연구)

  • 박상일;김정근
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.557-562
    • /
    • 2003
  • 산업체 소각로의 고온 배가스에는 소각물질의 특성에 따라 다양한 성분의 오염물질이 함유되어 있다. 고온 소각배가스의 후처리를 위하여 배가스냉각용 열교환기가 사용되고 있다. 그러나, 소각로 열교환기의 입구와 전열면에 파울링 현상이 발생하여 열교환기의 전열성능이 감소하고 또한 심한 경우, 유로면적이 줄어들어 통풍저항이 증대된다.(중략)

  • PDF

A Characteristics of Hg, Pb, As and Se Emitted from Small and Medium Size Waste Incinerator Stacks (중.소형 폐기물 소각시설에서 배출되는 수은, 납, 비소, 셀렌 배출특성)

  • Lee, Han-Kook;Moon, Bu-Shik;Lee, Dong-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1205-1214
    • /
    • 2005
  • This study was carried out to investigate the emission characteristics of volatile metals(Hg, As, Se) and semi volatile metals such as Pb from small and medium size municipal solid waste incinerators(MSWIs). The concentrations of Hg, Pb, As and Se in emission gas from small size waste incinerators were higher than those of medium size waste incinerators. This is probably due to less air pollutant control devices and high emission gas temperature of the small size waste incinerators relative to the medium size waste incinerators. Emission gas temperature from small and medium size waste incinerators were divided into 2 groups. The first group was about $100^{\circ}C$ and the second roup in the range of $400{\sim}700^{\circ}C$. The concentrations of emission gas at the second group were Hg $70.43\;{\mu}g/Sm^3$, Pb $0.94\;{\mu}g/Sm^3$, As $9.83\;{\mu}g/Sm^3$ and Se $5.05\;{\mu}g/Sm^3$. The concentrations of Hg, Pb, As and Se at the first group were lower than those found at the second group. Besides, the removal efficiencies of Hg in medium size waste incinerators were $55.2{\sim}95.9%$. Emission gas temperature reduction from waste heat boiler(WHB) contribute to control of Hg. Based on above results, we postulate that the temperature of flue gas should play a very important role in volatile metal control in small and medium size MSWIs. In order to improve the volatile metals removal efficiency, the temperature of cooling system must be controlled and the air pollution control device should be operated properly.

A Study on the Heat Exchanger Fouling Characteristics of Sludge Incinerator at the IronWorks (제철슬러지 소각로 열교환기에서의 파울링특성 연구)

  • 박상일;김정근;김기홍;박용준;조성문
    • Journal of Energy Engineering
    • /
    • v.12 no.3
    • /
    • pp.223-230
    • /
    • 2003
  • A study was performed to measure and analyze the gas-side fouling of heat exchanger to cool the exhaust gas from sludge incinerator at ironworks. The incinerator gas passes through inside of the vertical tubes of heat exchanger to preheat the combustion air. This kind of fouling occurs at the entrance region of the heat exchanger and thus the perforated fouling plate was designed to measure the gas-side fouling and to analyze the particulate deposit. As a result of analysis, the particulate deposition rate was influenced by temperature, particulate composition and size and also the deposition patterns were different according to the location of perforated fouling plate. The computational analysis was performed to obtain the deposition rates at the perforated fouling plate and the calculation showed that the deposition rate was varied with the hole size and particulate size. It was proved that the fouling at the entrance region of heat exchanger could be measured by the perforated fouling plate designed in this study.

Experimental Study on Thermal Resistant Properties of Synthetic Fiber Dust Filters Coated by Ceramic Materials (세라믹코팅 합성섬유 집진여과포의 내열성능 특성에 대한 실험적 연구)

  • 박현설;김상도;최호경;임정환;박석주;박영옥
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.99-100
    • /
    • 2001
  • 보일러, 소각로 등의 연소공정이나, 금속 용융과정 중에 발생하는 분진은 대부분 여과집진장치에 의해 처리된다. 이러한 연소, 금속용융 공정의 배가스는 매우 고온이기 때문에 공냉식이나 수냉식의 배가스 냉각장치를 거친 후 여과집진장치로 유입된다. 고온 배가스 냉각장치는 집진장치의 설치비를 가중시킬 뿐만 아니라 운전유지비의 상승을 초래한다. 따라서 고온에서도 집진성능을 유지할 수 있는 여과포의 개발이 요구되었고, 국외 유명 여과포 제조업체를 중심으로 고온적용 여과포 개발이 활발히 진행되어 왔다. (중략)

  • PDF

Simulation of the flue gas treatment processes of an industrial-waste incinerator using Aspen plus (Aspen plus를 이용한 산업폐기물 소각로의 배가스 처리 공정 모사)

  • Lee, Ju-Ho;Jung, Moon-Hun;Kwon, Young-Hyun;Lee, Gang-Woo;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3246-3252
    • /
    • 2009
  • The interest on the recovery of thermal energy using the waste has been rising to solve the problems of continuous increase of waste generation and the depletion of the fossil fuel recently. The incineration has been used most popularly as a treatment process of the waste for the energy recovery. However, it is expected that incineration and design cost will increase in the treatment of air contaminant emitted from incinerator. This research has simulated the actual incinerator and the flue gas treatment system using the Aspen plus which is the software to simulate the chemical process. The incineration process is composed of the 1st and 2nd combustor to burn the waste, SNCR process to reduce the $NO_x$ using the urea, and the steam generation process to save the energy during incineration. The $Ca(OH)_2$ slurry was used as an acid gas (HCl, $SO_2$) treatment materials and the removal efficiency for the products from the neutralization of acid gas in SDA and combustion ash was simulated at the bag filter. The simulation result has been corresponded with the treatment efficiency of emitted gas from the actual industrial waste incinerator and it is presumed to be used to forecast the efficiencies of flue gas treatment system in the future.

Source Estimation and Concentration Levels of PCBs in Ambient Air of an Industrial Area (공단지역 대기 중 PCBs의 오염농도 및 발생원 추정)

  • Kim, Kyoung-Soo;Song, Byung-Joo;Park, Seok-Un;Kim, Jong-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.385-389
    • /
    • 2005
  • To understand the pollution level by polychlorinated biphenyls (PCBs) in ambient air of industrial area, PCBs concentrations were measured at Sihwa and Banwol industrial region, Korea. The concentrations of total PCB and WHO-TEQ ranged from 2,080 to $5820\;pg/m^3$ (median value is 2,760) and from 0.19 to $1.01\;pgTEQ/m^3$ (median value is 0.42), respectively. In terms of homologues composition the fraction of highly chlorinated biphenyls(from hexa-CB to deca-CB) were higher than the air samples of other regions such as jeonju and yokohama area. The cluster analysis was conducted to study the relation between the air samples and sources such as incinerator flue gases and Aroclor samples. The isomer fractions in the homologue were used as input variables. Based on the results, the industrial ambient air samples were divided from source samples with long Euclidian distance. This suggest that the ambient air samples of Sihwa and Banwol were not on the influence of Aroclor and incinerators. Therefore, further investigation on systematical air monitoring will be required to estimate the sources of PCBs in the above industrial areas.

Nano Pulse Plasma Power Supply (나노 펄스 플라즈마 전원 장치)

  • Yoo, Hyo-Yol;Shim, Eun-Yong;Lee, Seung-Yun;Park, Hyung-Jin;Jo, Seong-Man
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.283-284
    • /
    • 2010
  • 소각로 배가스 탈황탈질 동시처리 시스템의 주요 장치인 나노 펄스 플라즈마 전원 장치(일명, Magnetic Pulse Compressor)의 상용화 성공과 향후 개선 방향에 대하여 논의한다.

  • PDF

Estimation of air pollutants generated in the industrial-waste incinerator using Aspen plus (Aspen plus를 이용한 산업폐기물 소각공정시 발생 오염물질 예측)

  • Lee, Ju-Ho;Jung, Moon-Hun;Kwon, Young-Hyun;Kim, Min-Choul;Lee, Jae-Jeong;Lee, Gang-Woo;Shon, Byung-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.1046-1049
    • /
    • 2009
  • 최근 화석에너지 고갈 문제와 폐기물의 지속적인 발생량 증가로 인해 폐기물을 이용한 열에너지 회수가 이슈화 되고 있다. 폐기물처리를 통한 에너지 회수 공정 가운데 소각이 가장 많이 이용되고 있으나 소각시 발생하는 대기오염 물질을 처리하기 위한 설계 및 설치비용에 많이 소요 된다. 본 연구에서는 화학공정 모사기인 Aspen plus를 이용해 소각공정 및 배가스 처리 공정모사를 실시하였다. 폐기물 소각 공정으로는 1 2차 연소실과 NO2를 환원하는 SNCR공정, 산성가스(HCl, SO2)를 제거하는 SDA공정, 입자상 물질을 처리 하는 bag filter공정을 모사하였다. 공정모사 결과 실제 산업폐기물 소각로의 처리효율과 일치 하였고 이를 바탕으로 동일한 공정 및 조건하에 소각로에 투입되는 폐기물의 조성비를 달리하여 공정 모사한 결과 오염물질의 배출량을 예측할 수 있었다. 이러한 오염물질 발생량 예측은 소각장의 폐기물 투입이 일정하지 않을 경우 조업 조건의 변경에 도움 뿐만아니라 공정개선의 효과적일 것으로 판단된다.

  • PDF

Simulation of flue gas treatment section in RDF combustion process using Aspen Plus (Aspen Plus를 이용한 RDF 소각시 발생하는 배가스 처리 공정 모사)

  • Lee, Ju-Ho;Jung, Moon-Hun;Kwon, Young-Hyun;Kim, Min-Choul;Lee, Gang-Woo;Shon, Byung-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.848-850
    • /
    • 2009
  • 화석에너지 고갈로 인한 유가 상승으로 폐기물 에너지화가 이슈화 되고 있다. 폐기물 고형 연료 RDF는 에너지 문제를 해결하기위한 대안 중 하나로 수송성, 저장성, 연소안정성이 우수하나 환경오염 물질의 발생이 문제가 된다. 이러한 오염물질을 처리하기 위한 배가스 오염 물질처리를 위한 plant 설비 비용과 시간이 많이 투자된다. Aspen plus는 mass energy balance와 화학적평형, 열역학을 이용하여 공정 모사를 할 수 있는 프로그램으로 검증되었다. RDF의 삼성분, 원소분석, 발열량을 입력을 통해 HCl, SOx, NOx, CO의 배출량을 예측하고 이에 맞는 SNCR, SDA 등과 같은 반응기를 적용 하므로써 다양한 배가스 처리를 모사 할 수 있다. NOx를 제어하기위에 urea주입과 SOx와 HCl을 제거하기 위한 CaO를 주입을 모사 하므로써 실제 운영 적용 전 단계에 역할로 유용한 도구로 판단된다.

  • PDF