• Title/Summary/Keyword: 세척용액

Search Result 267, Processing Time 0.038 seconds

Soil flushing of Pesticide-Contaminated Soil (Soil flushing 기법을 이용한 농약 오염토양 정화)

  • 전민하;최상일;장윤영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1999.10a
    • /
    • pp.87-89
    • /
    • 1999
  • 본 연구에서는 Sorfactant/Cosolvent 혼합용액을 적용한 Soil flushing 기법에 의해 농약(Endosulfan(6,7,8,9,10,10-Hexachlor-1,5,5a,6,9,9a-hexahydro-6,9-methane-2,3,4benzo (e)dioxathiepin-3-oxide))으로 오염된 토양의 정화효율을 알아보았으며, 회분식 및 연속식 실험을 통하여 최적의 운전조건을 도출하고자 하였다. 세척용액의 적정 사용조건을 알아보기 위한 회분식 실험은 Jar tester를 사용하여 진탕비 (토양 중량 : 세척용액 부피), Surfactant(SDS + POE$_{5}$, POE$_{9}$ + POE$_{14}$, POE$_{5}$ + POE$_{14}$, POE$_{14}$)와 보조용매(water, ethanol, methanol, ethanol+methanol)의 혼합비 및 농도 조건을 변화시켜가며 토양세척을 수행하였다. 세척용액은 보조용매에 Surfactant의 농도를 0.5%, 1%로 용해하여 적용하였다. 연속식 실험은 회분식 실험에서 얻어진 최적 세척용액 사용조건 즉, 계면활성제 SDS + POE$_{5}$(1:1, 용액농도 1%), 보조용매 ethanol을 일정 비율로 혼합한 세척용액을 오염된 토양이 충진된 유리칼럼에 여러 유량조건에서 1 - 20 pore volume까지 통과시켜 각 통과된 pore volume에서의 토양세척 효율을 알아보았다. 본 실험조건에서 얻어진 세척용액의 최적 통과 속도는 0.31 ㎤$cm^{-2}$$min^{-1}$ 이었으며, 세척온도의 증가에 따른 세척효율의 향상은 2$0^{\circ}C$이상에서 크게 둔화되었다. 또한 보조용매의 사용량을 줄이기 위해 에탄올을 물로 1:3까지 희석한 결과 세척효율에 큰 영향이 없음을 알 수 있었다.

  • PDF

Development of the Soil Washing System for the Remediation of Oil-Contaminated Soil (유류 오염토양 복원을 위한 토양세척 공정의 개발)

  • Gong, Jun;Cho, Jang-Hwan;Lee, Ji-Hui;Choi, Sang-Il
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.60-63
    • /
    • 1998
  • 본 연구에서는 유류 오염토양 복원을 위한 효율적인 세척공정을 구성하여 현장적용 가능성을 검토하였다. 토양세척공정은 co-current식 전세척장치와 counter -current식 세척조로 구성된다. 물이 주입되는 co-current식 전세척장치에서는 스크류 축의 회전력에 의한 토양 이송 및 스크류의 각 pitch 사이에 부착된 임펠러의 기계적 교반력에 의한 세척이 동시에 이루어진다. 전세척장치를 통과한 토양과 물은 세척조로 유입되어 세척용액과 반대방향으로 이동하게 된다. 세척조의 내벽에 부착된 나선형 웨어에 의해 적정 운전조건하에서 일정 크기를 기준으로 토양이 분리되며, 각 웨어 사이에 부착된 임펠러의 교반력에 의해 오염토양이 세척된다. 실험결과, 운전시 고려해야 할 주요 영향인자들은 전세척장치에서의 토양주입량은 1 kg/min, 진탕비는 1, 회전속도는 50 rpm에서 최대 세척효율(#4-, 83.6%)을 보였으며, 세척조에서는 토양.물 주입위치 15 cm, 회전속도 5 rpm, 경사각 6$^{\circ}$, 세척용액 주입유량이 0.8 L/min일 때 최대 세척효율인 97.9%(#4-)를 나타냈다.

  • PDF

Evaluation of Contact Lens Care Regimens in Removing Tear Lipids on Silicone Hydrogel Lens (콘택트렌즈 관리방법에 의한 실리콘하이드로겔렌즈의 지방침전물 제거효과)

  • Kang, You-Sun;Lee, Koon-Ja;Ju, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.347-353
    • /
    • 2010
  • Purpose: An in vitro study was conducted to compare the lipid cleaning efficacy of care solutions on balafilcon A silicone hydrogel (SiHy) lens. Methods: Lipid spoilation was performed by incubating balafilcon A SiHy lenses in phosphate buffered saline (PBS) containing oleic acid, oleic acid methyl ester and cholesterol. Spoiled contact lenses rinsed with PBS were cleaned with surfactant cleaner, alcohol containing cleaner and multipurpose solution (MPS) respectively and repetitive spoilation and cleaning was conducted up to 14 times. To observe the cleaning effect of ultrasonic wave on the lipid deposit, each spoiled lens was ultrasonicated and then compared with non-sonicated lens. Lipids deposit on the contact lenses was extracted by methanol:chloroform (1:1, v/v) solution. High performance liquid chromatography was used to analyze and quantify lipid deposit extracts. Results: The effectiveness of alcohol containing surfactant cleaner on the lipid deposits was better than that of surfactant cleaner and MPS, and the cleaning efficacy was significantly higher in the ultrasonic wave treated group. Lipid deposits were not removed completely by contact lens care solutions so that lipid deposits increased continuously and cumulatively. Conclusions: The cleaning efficacy of contact lens care solutions was not satisfactory to remove lipid deposits on the SiHy lens that new cleaning products specially designed for SiHy lenses are needed to develop.

$H_2$$O_2$Enhanced Washing of Lubricant-Contaminated Soil ($H_2$$O_2$를 이용한 윤활유 오염토양 세척 효율 향상에 관한 연구)

  • 정민정;최상일;장윤영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1999.10a
    • /
    • pp.99-102
    • /
    • 1999
  • 본 연구에서는 대표적인 물리 화학적 토양정화방법인 토양세척기법의 효율증진을 위하여, Fe를 다량 함유한 고농도 윤활유 오염토양을 대상으로 알카리 용액과 산성용액의 세척효율을 비교 검토하고, 과산화수소의 첨가에 따른 세척효율의 향상효과를 알아보았다. 세척용제인 NaOH와 HCl를 이용하여 세척효율 검토 결과 NaOH를 이용한 경우에 약 60% 의 세척효율을 나타냈다. 또한 NaOH 농도에 따른 정화 효율은 각각 0.5% > 1% $\geq$ 2% 순서로 증가하였다. 기존의 세척효율을 향상시키기 위하여 과산화수소를 첨가하고 오염토양의 정화효율을 비교 검토한 결과 NaOH용액에서는 과산화수소의 농도가 증가할수록 정화효율이 증가하였으나 NaOH의 농도증가에 대해서는 큰 영향을 보이지 않았으며, NaOH 3%의 농도에서 과산화수소 1%를 첨가했을 때 85%의 정화효율을 나타냈다. 또한 과산화수소 주입시기에 따른 영향을 검토한 결과 세척 후 과산화수소를 주입한 경우에 정화효율이 높았다. 반면에 HCl의 경우는 HCl의 농도가 증가할수록 정화효율이 증가하였고, 세척하지 않고 과산화수소를 주입한 경우에 정화효율이 증가하였다. 고농도의 윤활유 오염토양의 세척효율을 증진시키기 위한 처리로서 과산화수소의 주입은 NaOH 상태에서 그 효율이 약 15%정도 증진되었으며, 일정시간에 이르면 정화효율이 평형에 도달하는 것을 알 수 있었다. HCl 상태에서는 25%의 정화효율이 증진되는 것을 알 수 있었다.

  • PDF

The Difference of the Cleaning and Wettability-maintaining Efficacy of Lens Care Solution to RGP Lens (관리 용품에 따른 RGP 렌즈의 세척효과 및 습윤성 차이)

  • Kim, Myoung-Hea;Park, Mi-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.27-34
    • /
    • 2006
  • We investigated the question whether the efficacy of cleaning tear components on RGP lens and preserving the superior wettability of RGP lens depended on the different type of contact lens care system - RGP lens care solution, SCL care solution, combined solution both for SCL and RGP lens or saline solution. The removal efficacy of the deposited protein was examined by Lowry protein assay and Scanning Electro Microscope(SEM) and residual lipid concentration on RGP lens was determined by High Pressure Liquid Chromatology(HPLC). Wettability was assessed with an equilibrium water-in-air contact angle method. When cared by RGP lens solution, it was demonstrated that 62 percent out of the adhered protein on RGP lens were removed and the removal efficacy of RGP lens solution was not only 4 times than saline solution and the alternative but also higher twice than SCL solution. Contrarily, the SCL solution had the most excellent removal efficacy of the adhered protein on SCL. These results suggest that the cleaning efficacy is thought to be affected by the other factors like the viscosity of care solutions, which mutual contact between RGP lens and care solutions is on the increase due to the viscosity enhancer in RGP lens care solution. RGP lens solution had the greatest removing efficacy to cholesterol and the residual cholesterol concentration was decreased to 50%. It is significant for RGP lens to preserve the superior wettability which means the predictive value for comfortable wearing and it showed that the RGP lens solution offered the most excellent efficacy to maintain the surface wettability. Combined solution both for SCL and RGP lens had weak efficacy of cleaning and maintaining wettability for RGP lens compared to RGP lens care solution.

  • PDF

The Actual Management State of Trial Contact Lenses and Lens Care Products in Local Optical Shops (안경원의 시험착용 콘택트렌즈 및 관리용품 관리 실태)

  • Park, Mijung;Lee, Unjung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.391-401
    • /
    • 2011
  • Purpose: In the present study, the actual management state of trial contact lenses and lens care products in local optical shops was surveyed and analyzed to reduce the risk of lens complication possibly induced by neglecting lens care. Methods: The feeling of contact lens wearers during the wear of trial contact lenses was surveyed. Futhermore, the actual management state of trial contact lenses such as cosmetic lens and RGP lens and lens care products was also investigated by surveying opticians who trade contact lenses in local optical shops. Results: It was found that consumers trusted the sanitary conditions of the lens since trial cosmetic contact lens and RGP lens were cleaned before and after trails by over 98% of opticians in local optical shops. For trial cosmetic lens, cleaning with normal saline, multipurpose solution for soft lens and combination of saline and multipurpose solution were 38.5%, 40.5% and 21%, respectively, before trials. After trials, cosmetic lenses were cleaned with normal saline, multipurpose solution for soft lens and a combination of saline and multipurpose solution were 13%, 75%, and 12%, respectively. On the other hand, cleaning with normal saline, multipurpose solution for RGP lens and combination of saline and multipurpose solution were 28.5%, 38.5% and 33%, respectively, before trying trial RGP lens. After trials, RGP lenses were cleaned with normal saline, multipurpose solution for RGP lens and a combination of saline and multipurpose solution were 2.5%, 70%, and 27.5%, respectively, indicating that relatively many opticians followed the lens cleaning regimen. In local optical shops, the cleaning trial cosmetic lens was mainly conducted at every 10 days or a month and the washing cycle of cosmetic lens case was in a month or 2~3 months. The cleaning interval of trial RGP lens was primarily in a month or 2~3 months. For those lens cases, more than 75% of opticians washed them with a surfactant and then rinsed with cold water. The storing periods of lens care products were primarily in a week for saline and in a month and 2~3 months indicating that storing period of lens care products was relatively well-kept in local optical shops. Conclusions: It is thought that the concern about any microbial infection is not that high since trial contact lenses and lens care products were generally well-managed by opticians in local optical shops from the results above. However, better public eye health and better public confidence in opticians may be possible if further strengthen in avoidance of lens cleaning with saline, keep of cleaning cycles within 2 weeks and rinsing of lens cases with hot water happens.

Characterization and Feasibility Study of the Soil Washing Process Applying to the Soil Having High Uranium Concentration in Korea (우라늄 함량이 높은 국내 토양에 대한 토양학적 특성 규명 및 토양세척법의 적용성 평가)

  • Chang, See-Un;Lee, Min-Hee
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.5
    • /
    • pp.8-19
    • /
    • 2008
  • The physicochemical properties of soils having high uranium content, located around Duckpyungri in Korea, were investigated and the lab scale soil washing experiments to remove uranium from the soil were preformed with several washing solutions and on various washing conditions. SPLP (Synthetic Precipitation Leaching Procedure), TCLP (Toxicity Characteristic Leaching Procedure), and SEP (Sequential Extraction Procedure) for the soil were conducted and the uranium concentration of the extracted solution in SPLP was higher than Drinking Water Limit of USEPA (30 ${\mu}g$/L), suggesting that the continuous dissolution of uranium from soil by the weak acid rain may generate the environmental pollution around the research area. For the soil washing experiments, the uranium removal efficiency of pH 1 solution for S2 soil was about 80 %, but dramatically decreased as pH of solution was > 2, suggesting that strong acidic solutions are available to remove uranium from the soil. For solutions with 0.1M of HCl and 0.05 M of ${H_2}{SO_4}$, their removal efficiencies at 1 : 1 of soil vs. washing solution ratio were higher than 70%, but the removal efficiencies of acetic acid, and EDTA were below 30%. At 1 : 3 of soil vs. solution, the uranium removal efficiencies of 0.1M HCl, 0.05 M ${H_2}{SO_4}$, and 0.5M citric acid solution increased to 88%, 100%, and 61% respectively. On appropriate washing conditions for S2 soil such as 1 : 3 ratio for the soil vs. solution ratio, 30 minute for washing time, and 2 times continuous washing, TOC (Total Organic Contents) and CEC (Cation Exchange Capacity) for S2 soil were measured before/after soil washing and their XRD (X-Ray Diffraction) and XRF (X-Ray Fluorescence) results were also compared to investigate the change of soil properties after soil washing. TOC and CEC decreased by 55% and 66%, compared to those initial values of S2 soil, suggesting that the soil reclaimant may need to improve the washed soils for the cultivated plants. Results of XRF and XRD showed that the structural change of soil after soil washing was insignificant and the washed soil will be partially used for the further purpose.

The Deposition of Tear Protein according to Soft Lens Materials and The Cleaning Efficacy of Multi-purpose Solution according to the Surfactant Types (소프트렌즈 재질 별 누액단백질 침착 및 계면활성제 종류에 따른 다목적용액의 세척효율)

  • Park, Mijung;Kwon, Young Dae;Lee, Wang Jae;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.179-188
    • /
    • 2014
  • Purpose: The present study was aimed to investigate the cleaning efficacy of multi-purpose solutions containing different types and content of surfactants and their effect on the visible light transmittance of soft lens. Methods: Soft lenses made of different materials (etafilcon A and hilafilcon B) were deposited tear proteins by using the artificial tear and then compared the resulting cleaning efficacy and visible light transmittance after cleaning the lens with 6 types of multi-purpose solutions containing different content of surfactants. Results: The cleaning efficacy of multi-purpose solutions was variously shown as approximately 23~43% according to the active concentration of surfactants and surface tension in multi-purpose solution when etafilcon A lens cleaned with rubbing. The highest cleaning efficacy was detected when cleaned with the multi-purpose solution containing hydrogen peroxide besides surfactant however, the amount of remaining protein was still high on the lens. After washed with multi-purpose solution, the visible light transmittance of lens was in 89.8 to 90.8%. The amount of protein deposited on hilafilcon B lens was very small compared with it on etafilcon A lens even though it was incubated in artificial tears for 7 days, which showed 5~10% of protein amount in etafilcon A lens and the decrease of visible light transmittance was also not significant. In case of rubbing with multi-purpose solution, the cleaning efficacy on hilafilcon B lens was in 45.4 to 67.4% however, the order of cleaning efficacy of multi-purpose solution was different from it on etafilcon A lens. The visible light transmittance of hilafilcon B lens has been restored to the level of new lens. Conclusions: From the result, it is concluded that the appropriate multi-purpose solution should be selected according to the lens material and the amount of protein deposit on the basis of understanding surfactants and active principle for proper care of protein deposit on soft lens and the cleaning with rubbing is more efficient for lens care regardless of manufacturer's guideline.

A Treatability Study on the Soil Washing Device for the Remediation of Oil-Contaminated Soil (유류 오염토양 복원을 위한 토양세척 장비의 적용성 연구)

  • Kong, Jun;Choi, Sang-Il
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.3
    • /
    • pp.109-116
    • /
    • 1998
  • Treatability tests of a soil washing device were performed for the remediation of eil-contaminated soil. The contaminant-containing soil with water was first fed into a oc-current screw conveyor and then into a counter-current washer. Surfactant was introduced into the washer and feeding soil was continuously separated on the basis of #40 mesh at the same time. A washing efficiency of 97.9% was achieved by the the soil washing device optimized.

  • PDF

The Effects of Ultrasonic Cleaner for Eye Glasses on Protein Deposits and Parameters in Soft Contact Lens (안경용 초음파세척기에 의한 소프트콘택트렌즈의 단백질 침전물 세척효과)

  • Ju, Eun-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.227-234
    • /
    • 2010
  • Purpose: The cleaning effect of protein deposit and the change of contact lens parameters by ultrasonic cleaner for eye glasses on the soft contact lenses were investigated. Methods: Etafilcon A contact lenses contaminated with protein, was ultrasonicated by ultrasonic cleaner for eye glasses and for the control group, spoiled contact lenses were cleaned by multi-purpose solution. The remaining protein deposits on the contact lenses were determined after extraction and the changes of overall diameter, base curve, center thickness power, and water contents on contact lenses were measured and surfaces of contact lenses were observed by scanning electron microscope. Results: The cleaning efficacies of multi-purpose solution on protein deposited etafilcon A contact lenses were 6.08%, and 23.73~33.92% in the group of ultrasonic cleaner for eye glasses with multi-purpose solution and 0~12.99% in the group of ultrasonic clear for contact lens with multipurpose solution depending on the treatment time. The changes of parameters and surface on contact lenses by ultrasonication were not observed. Conclusions: Ultrasonic cleaner for eye glasses can be used to eliminate protein deposits for the diagnostic soft contact lens in the office since it was effective to eliminate protein deposits and not caused change of parameters on soft contact lenses.