• Title/Summary/Keyword: 세정제

Search Result 164, Processing Time 0.026 seconds

Survey of Actual Conditions of Material Safety Data Sheet and Quantitative Risk Assessment of Toxic Substances : Substitutes for Degreasing Agents (일부 대체세정제 제조업체의 물질안전보건자료의 실태와 그 화학물질의 유해성 평가에 관한 연구)

  • Yoon, Chong-Guk;Jeon, Tae-Won;Chung, Chin-Kap;Lee, Myung-Hee;Lee, Sang-Il;Cha, Sang-Eun;Yu, Il-Je
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.2
    • /
    • pp.18-26
    • /
    • 2000
  • Since the regulation of MSDS (Material Safety Data Sheets) had started from July 1996, employers were required to furnish MSDS for the chemicals in use in their workplace. However, many MSDS did not contain upright information for the chemicals, and they were not updated regularly, and were not written in the standard format required by the Industrial Safety and Health Act (ISHA). The purposes of this study were 1) to examine the reliability of MSDS for mixed solvents, 2) to provide reliable MSDS to employers or employees, 3) to find out any difficulties in implementing MSDS after the initiation, and 4) to promote regular MSDS updating and to ensure the reliability of MSDS for chemical manufacturers. To check the reliability of MSDS of mixed chemicals, 21 samples of mostly degreasing solvents were collected along with their MSDS from the work place. The samples were analyzed by gas chromatography-mass selective detector(GC-MSD). Their components were classified as saturated hydrocarbon, cyclic hydrocarbon, aromatics, and halogen containing hydrocarbon, and the amount of each class were measured. Manufacture's MSDS were compared with the actual composition of the collected samples, and further examined the reliability by checking whether the chemicals analyzed were included in the MSDS correctly. Finally, each item of MSDS was evaluated whether the MSDS correspond to the regulation required by ISHA. The results were following: 1) most of the degreasing solvents in MSDS were incorrect in their composition and contents, 2) the information in the MSDS including hazard classification, exposure level, toxicity, regulatory information were incorrectly provided, and 3) some MSDS did not disclose carcinogens in their MSDS. Continuous monitoring of MSDS was required to ensure reliability of MSDS. The Chemicals containing hydrocarbons from C10-C15 need to be tested to provide toxicity data. In addition, governmental support for providing correct MSDS was recommended to ensure reliability of MSDS. The MSDS regulation relating to the confidential business information may need to be revised to ensure reliability of MSDS.

  • PDF

Adolescents' Purchasing Behavior for Hair-care Products (청소년의 헤어제품 구매 행동에 관한 연구)

  • Song, Yean-Hwa;Oh, Kyung-Wha
    • Journal of Korean Home Economics Education Association
    • /
    • v.23 no.2
    • /
    • pp.1-16
    • /
    • 2011
  • This study investigates the relationship between the purchasing behavior for hair-care products and the attitude toward hair-care products by adolescents. A total of 412 middle and high school students located in Seoul and Gyunggi-do province participated in this research. SPSS 12.0 for Windows Program was utilized for statistical analysis. As a result, the hair concerns and the satisfaction of adolescents as well as their attitudes towards hair-care products were significantly affected by gender, school level, and educational experiences. Female high school students with some degree of educational experiences had a more rational and brand-oriented attitude. Students having a higher rational and brand-oriented attitude bought hair-care products in regards to the quality of the product and environmental impact. On the other hand, those having a conspicuous and fashion pursuit attitude showed an image and fashion concern purchasing behavior. Adolescents usually purchased styling and dyeing products at a cosmetic specialty store and hair-care cleaning products from a discount store. They obtained the information about hair-care products from relatives, personal experiences, and TV advertisements.

  • PDF

A Study on Clean Agents for Halon Replacement in the Portable Extinguisher with CO2 as an Expellant Gas (이산화탄소를 가압원으로 하는 할론대체 소화기용 청정소화약제에 대한 연구)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.51-55
    • /
    • 2019
  • To prevent ozone depletion caused by CFCs, the replacement of Halon with clean agents has been developed in the fire protection field along with refrigerants, detergents, and foaming agents. The alternatives for Halon 1211 have been developed in the portable fire extinguisher area and HCFC-123 is used widely as a clean fire extinguishing agent. The type of expellant gas is important because their own vapor pressure is low. In this study, HCFC-123, HCFC-124, HFC-125, and Novec-1230 were selected as fire extinguishing agents and CO2, which is expected to improve the fire extinguishing ability, was chosen as the expellant gas. For each agent, experiments changing the agent and CO2 amount were carried out and HCFC-123 showed a good result, as expected. The extinguisher, HCFC-123 of 1.5 kg, showed the same ability to suppress a class A and B fire as the extinguisher, HCFC-123 of 2.5 kg, which is currently sold on the market. According to this result, the expellant gas has a subsidiary fire extinguish effect. This can reduce the amount of HCFC fire extinguishing agent, which is categorized in the phase-out alternatives, and is a more eco-friendly and economical fire extinguisher than the previous one. This study can also help solve the problems of CO2 fire extinguishers for class B and C fires, and can be used to extinguish electric and electron facilities fire, which contains large amounts of class A fire combustibles.

Surface changes of denture base resin according to two toothpastes and a kitchen detergent (일부 세치제와 주방세제 사용에 의한 의치상 레진의 표면변화)

  • Kang, Jae-Kyoung;Kim, Soo-Hwa;Yoo, Eun-Mi;Choi, Hye-Sook;Choi, Yu-Ri;Kim, Kwang-Mahn
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.3
    • /
    • pp.611-620
    • /
    • 2012
  • Objectives : This study evaluated the changes in surface roughness of denture base resin according to the types of denture cleansers. Methods : A denture base resin(Vertex RS, Dentimax, Netherland) was used. Two toothpaste(Antiplaque, Bukwang, Korea; 2080, Aekyung, Korea) and a kitchen detergent(Trio, Aekyung, Korea) were used as a denture cleanser. The specimens were put on the V8 crossbrushing machine(Sabri enterprises, Downers grove, IL, USA) to reproduce toothbrushing and the toothbrushes were flat, round end and soft type. The surfaces of denture base resin specimens were observed by profilometer(SJ-400, MITUTOYO, Japan) and SEM(S-3000N, Hitachi Co., Ibaraki, Japan). Results : 1. According to the result of measuring surface roughness, there was statistically significant difference in Ra, Rq, and Rz(p<0.05). 2. As for Ra, Rq and Rz, Antiplaque toothpaste showed the highest roughness, and there was significant difference from other groups(p<0.01). 2080 toothpaste, Trio, and distilled water were classified as the same group. 3. According to the result of observation with the SEM, the surfaces of the Antiplaque toothpaste group after toothbrushing showed the greatest roughness, and the surfaces of 2080 toothpaste, Trio, and distilled water groups were rough in order. Trio and distilled water had the surfaces similar to those before toothbrushing. Conclusions : Studies to compare the efficacy of denture management methods and examine the effects of denture cleansers on denture materials will be helpful for dental hygienists and dentists providing patients with proper information and education. And it will be also useful for denture users' oral health.

Toxicity study of GC-100X in rats and beagles (랫드와 비글에서 GC-100X 세정제의 독성에 대한 연구)

  • Kang, Kyung-Sun;Cho, Sung-Dae;Ahn, Nam-Shik;Jung, Ji-Won;Yang, Se-Ran;Park, Joon-Suk;Park, Ki-Soo;Hong, In-Sun;Seo, Min-Soo;Jo, Eun-Hye;Nguyen, Ba Tiep;Lee, Yong-Soon
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.1
    • /
    • pp.29-40
    • /
    • 2004
  • Because cleaning products are part of our everyday lives, it is essential that they should not present significant risks to health. However, many petrochemicals in most soaps and detergents can be absorbed through the scalp and skin and, over time, accumulate in the organs and tissues. This accumulation may result in brain, nerve, and liver damage. Therefore, it is interested in developing non-harmful detergent. According to Korea Research Institute of Chemical Technology, GC-100X may be non-harmful and non-corrosive alkaline ionic water (pH 12). It is composed of hydroxyl radicals and supplemented with xylitol. To evaluate influence of GC-100X on rats and beagles, GC-100X was diluted with distilled water (25%, 50%, and 100% solution respectively). Each of diluted GC-100X was daily treated per oral. In body weight analysis, urinary analysis, ophthalmological test and autopsy, we did not find any significance, but in serum biochemical analysis and hematological analysis, we found some significances in middle dose group compared with control group. These significances in serum biochemical analysis and hematological analysis may be not induced by GC-100X, because it was not found to be significant from control group in histopathological examination. Thus, it is concluded that NOEL(No Observed Effect Level) of GC-100X may be higher than all treatment doses used in this study, and GC-100X may be a non-toxic detergent.

THE EFFECT OF DENTURE CLEANSERS ON SOFT LINING MATERIALS (의치 세정제가 탄성 의치상 이장재에 미치는 효과에 관한 연구)

  • Jang, Bok-Sook;Kim, Chang-Whe;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.219-235
    • /
    • 1993
  • To determine the compatibilities of soft liming materials with denture cleansers by measuring the flexibility and elasticity and investigating the surface changes, 4 self-curing acrylic resin soft lining materials and 1 heat-curing silicone soft lining material were evaluated. 3mm thick x 20mm diameter discs of soft lining materials were individually bonded to a hard acrylic resin base as per manufacturers’instructions. Using an Instron universal testing machine, a static stress of $2kg/cm^2$ was applied for 30secs., the strain in compression was measured, giving an indication of the material’s flexibility. Elastic recovery was measured at 10secs. After removal of stress. Surface changes were investigated with Stereomicroscope. Then the specimens were immersed in 4alkaline peroxide denture cleansers and water as control group, tests were carried out at 1 day, 2 days, 7 days, 14 days and 30 days. The results were as follows : 1. Alkaline peroxide denture cleansers caused considerable porosity on the surface of selfcuring acrylic resin soft lining materials, and the most affected by the cleansers were Viscogel, Coe-Soft, Coe-Comfort, Lynal, in that order. 2. There was significant difference in flexibility between each soft lining material except for Coe-Comfort and Visco-gel, and every soft lining material was significant difference in elasticity. Especially Molloplast-B and Lynal were less flexible and more elastic than other soft lining materials(p<0.05). 3. The denture cleansers increased the flexibility and elasticity of the soft lining materials compared with control group(p<0.05), and Denalan, Polident, Kleenite, Efferdent affected the soft lining materials in that order. 4. There was significant difference in flexibility between each denture cleanser except for Denalan and Polident(p<0.05). Though Denalan and Polident, Denalan and Kleenite did not show significant difference in elasticity, other denture cleansers showed significant difference among each other(p<0.05). 5. Clinically Coe-Comfort, Coe-Soft and Visco-gel were incompatible with alkaline peroxide denture cleansers, and Lynal would be used within only 2 weeks. But Molloplast-B was compatible with alkaline peroxide denture cleansers.

  • PDF

Examination and Quantification of Preservatives in Cosmetics for Children (어린이용 화장품에 사용되는 보존제 및 함유량 조사)

  • Jung, Sam Ju;Hwang, Young Sook;Choi, Chae Man;Park, Ae Suk;Kim, Su Un;Kim, Hyun Jung;Kim, Jung Hun;Jung, Kweon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.3
    • /
    • pp.219-227
    • /
    • 2015
  • This study was conducted to determine 10 preservatives (benzyl alcohol (BAl), phenoxyethanol (PE), benzoic acid (BA), sorbic acid (SA), methyl paraben (MP), ethyl paraben (EP), propyl paraben (PP), isopropyl paraben (IPP), butyl paraben (BP), isobutyl paraben (IBP)) levels in 125 cosmetics (n = 125) for children by the simultaneous analysis of HPLC. The detection ranges were as follows; 0.01 ~ 0.91% (n = 35) for PE, 0.01 ~ 0.48% (n = 28) for BA, 0.01 ~ 0.78% (n = 9) for BAl, 0.01 ~ 0.11% (n = 3) for SA, 0.04 ~ 0.21% (n = 8) for MP, 0.02 ~ 0.09% (n = 8) for PP, and 0.04% (n = 1) for EP. The order of detection rates was cleanser (63%) > cream (48%) > sunscreen (46%) > lotion (38%) > oil (13%). At least one of target preservatives was contained in 50% (63/125) of samples and the content of the detected preservatives was within maximum allowed amount established by KFDA. Phenoxyethanol and benzoic acid were used more frequently than paraoxybenzoate esters (parabens) in cosmetics for children and the detected parabens was mainly the mixture of methyl paraben and propyl paraben.

Effects of the Wet Cleaning to the Color Change of the Dyed Fabrics with Natural Dyes (천연염색포의 습식세척에 의한 색상변화)

  • Baek, Young-Mee;Goto-Doshida, Sumiko;Saito, Masako
    • Journal of Conservation Science
    • /
    • v.28 no.1
    • /
    • pp.21-27
    • /
    • 2012
  • In the Chosun period, the noble class usually buried the dead bodies in the lime-covered tomb. Recently their costumes are excavated while maintaining the shape. However, the textiles discovered from the inside have been degradated by a body and moisture. To conserve these textiles one of the most important thing is how to clean these textiles right after the excavation. The purpose of this study is to examine the effects of wet cleaning to minimize the color change of textile remains. For this purpose, silk and cotton were dyed with natural dyes (7 red, 1 blue, 6 yellow, 4 green and 4 purple colors), then they were kept for 6 months with pork meat at $10^{\circ}C$, and were washed by four cleaning solutions (water, anionic surfactant (SDS), non-ionic surfactant (Triton X-100) and natural surfactant (saponin)) at $20^{\circ}C$ and $40^{\circ}C$. The color change was evaluated by color difference (${\Delta}E$) between non-treated and after washed samples. From the results, it was found that the color changes are significantly different depending on the washing temperature, textile material, the cleaning agents and the type of dyes.

THE EFFECTS OF DENTURE CLEANSERS AND DISINFECTANTS ON THE COLOR, SURFACE HARDNESS, SURFACE ROUGHNESS OF DENTURE BASE RESINS (의치세정제와 소독제가 의치상 레진의 색조, 표면경도, 표면조도에 미치는 영향에 대한 연구)

  • Yang Hee-Jin;Jang Bok-Sook;Chung Dong-June;Heo Seong-Joo;Han Dong-Hoo;Shim June-Sung;Chang Myung-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.105-113
    • /
    • 2001
  • The purpose of this study is to compare effects of denture cleansers and disinfectants on the color. surface hardness, and surface roughness of reinforced acrylic resin using polyhedral oligosilsesquioxane molecules(POSS resin) to those of common resins. According to manufacturer's instructions, 45 specimens were made from three denture resins(Luciton 199, Paladent 20, POSS resin), and polished. Five denture cleansers(distilled water, glutaraldehyde, alkaline hypochlorites, chlorhexidine, alkaline peroxides) in combination with three denture resins were evaluated before and after immersion for 7 days. Color data in $L^*a^*b^*$ system were measured with a colorimeter. Surface hardness data were measured with a microhardness tester. Surface roughness data were measured with a 3-dimensional surface analyzer. Data were analyzed with two-way ANOVA, one-way ANOVA, and t-test. The results were as follows : 1. All resins(Luciton 199, Paladent 20, POSS resin) showed significant differences in color after immersion in hypochlorites(p<0.05). 2. POSS resin showed significant differences in color compared with Paladent 20 in all denture cleansers, but no statistically significant differences with Luciton 199(p<0.05). 3. Luciton 199 showed significant differences of surface hardness in chlorhexidine, Paladent 20 showed significant differences in glutaraldehyde and chlorhexidine. POSS resin showed a little change of surface in all denture cleanser, but no statistically significant differences(p<0.05). 4. Luciton 199 and Paladent 20 showed significant differences of surface roughness in hypochlorites and glutaraldehyde, and POSS resin showed no statistically significant differences in all denture cleansers(p<0.05).

  • PDF

Cleansing effect of the alkaline ionized water on microorganisms of the denture surface (알칼리 이온수의 의치 미생물에 대한 세정효과에 관한 연구)

  • Kim, Young-Mi;Choi, Yu-Sung;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.138-144
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the cleansing effect of recently developed alkaline ionized water, e-WASH, on microorganisms of the denture surface. Materials and methods: Removable partial and complete dentures were randomly assigned to the experimental group of 41 dentures, and the control group of 26. The denture was immersed in the e-WASH solution (experimental group), or tap water (control group) for 5 minutes. The plaque was collected from the denture surface before and after immersion, and smeared on the slide glass. Amount and motility of microorganisms were compared according to the morphology and strain of microorganisms, using the phase contrast microscope. Statistical analysis was accomplished with paired t-test and independent t-test at 95% confidence level (P<.05). Results: 1. The amount of cocci, bacilli, filamentous, spiral/comma, and the motility of bacilli, filamentous, and spiral/comma were decreased after denture cleansing with the alkaline ionized water, e-WASH (P<.05). But in the control group, only the amount of cocci showed a significant difference (P<.05), but no difference from the others. There were no differences in other analysis. 2. In the experimental group, the amount of cocci, bacilli, filamentous, spiral/comma, and the motility of bacilli, filamentous, and spiral/comma were smaller and more inactive compared to the control group (P<.05). Conclusion: These results indicated that the alkaline ionized water, e-WASH could effectively reduce the amount and motility of the experimented microorganisms on the denture surface, and that e-WASH could be recommended as an effective denture cleanser.