THE EFFECTS OF DENTURE CLEANSERS AND DISINFECTANTS ON THE COLOR, SURFACE HARDNESS, SURFACE ROUGHNESS OF DENTURE BASE RESINS

의치세정제와 소독제가 의치상 레진의 색조, 표면경도, 표면조도에 미치는 영향에 대한 연구

  • Yang Hee-Jin (Division of Prosthodontics, Department of Dentistry, Catholic University) ;
  • Jang Bok-Sook (Division of Prosthodontics, Department of Dentistry, Catholic University) ;
  • Chung Dong-June (Department of High Polymer Engineering, Seongkyunkwan University) ;
  • Heo Seong-Joo (Department of Prosthodontics, College of Dentistry, Seoul National University) ;
  • Han Dong-Hoo (Department of Prosthodontics, College of Dentistry, Yonsei University) ;
  • Shim June-Sung (Department of Prosthodontics, College of Dentistry, Yonsei University) ;
  • Chang Myung-Woo (Department of Prosthodontics, College of Dentistry, University of Nebraska)
  • 양희진 (가톨릭대학교 치과학교실 보철과) ;
  • 장복숙 (가톨릭대학교 치과학교실 보철과) ;
  • 정동준 (성균관대학교 고분자공학과) ;
  • 허성주 (서울대학교 치과대학 치과보철학교실) ;
  • 한동후 (연세대학교 치과대학 치과보철학교실) ;
  • 심준성 (연세대학교 치과대학 치과보철학교실) ;
  • 장명우 (네브라스카 주립대 치과보철학교실)
  • Published : 2001.02.01

Abstract

The purpose of this study is to compare effects of denture cleansers and disinfectants on the color. surface hardness, and surface roughness of reinforced acrylic resin using polyhedral oligosilsesquioxane molecules(POSS resin) to those of common resins. According to manufacturer's instructions, 45 specimens were made from three denture resins(Luciton 199, Paladent 20, POSS resin), and polished. Five denture cleansers(distilled water, glutaraldehyde, alkaline hypochlorites, chlorhexidine, alkaline peroxides) in combination with three denture resins were evaluated before and after immersion for 7 days. Color data in $L^*a^*b^*$ system were measured with a colorimeter. Surface hardness data were measured with a microhardness tester. Surface roughness data were measured with a 3-dimensional surface analyzer. Data were analyzed with two-way ANOVA, one-way ANOVA, and t-test. The results were as follows : 1. All resins(Luciton 199, Paladent 20, POSS resin) showed significant differences in color after immersion in hypochlorites(p<0.05). 2. POSS resin showed significant differences in color compared with Paladent 20 in all denture cleansers, but no statistically significant differences with Luciton 199(p<0.05). 3. Luciton 199 showed significant differences of surface hardness in chlorhexidine, Paladent 20 showed significant differences in glutaraldehyde and chlorhexidine. POSS resin showed a little change of surface in all denture cleanser, but no statistically significant differences(p<0.05). 4. Luciton 199 and Paladent 20 showed significant differences of surface roughness in hypochlorites and glutaraldehyde, and POSS resin showed no statistically significant differences in all denture cleansers(p<0.05).