프로판/이소부탄 혼합냉매를 적용한 가정용 냉장고의 성능에 관한 연구 (Performance Evaluation of Propane(R290)/Isobutane(R600a) Mixture as a Substitute for CFC12 in Domestic Refrigerators)

  • 임병한;박윤범;유환규;정동수;김종보
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.249-265
    • /
    • 1995
  • The performance of a refrigerant mixture of propane(R290)/isobutane(R600a) as a substitute for CFC12 was investigated in a domestic refrigerator with single evaporator. A thermodynamic cycle simulation indicated an increase in COP of a 1.7 to 2.4% with R-290/600a in the composition range of 0.2 to 0.6 mass fraction of R290 compared to CFC12. For the tests, two units($299{\ell}$, $465{\ell}$) were used. All refrigeration components remained the same throughout the tests, except that the length of capillary tube and amount of charge were changed for the mixture. The refrigerators were fully instrumented with more than 20 thermocouples, 2 pressure transducers, and watt/watt-hour meter for each refrigerator. 'Energy consumption test' and 'no load pulldown test' were performed under the same condition. The experimental results obtained with the same compressor indicated that R-290/600a mixture at 0.6 mass fraction of R290 showed a 3 to 5% increase in energy efficiency and a faster cooling speed compared to CFC12. The R-290/600a mixture showed a shorter compressor on-time and a lower compressor dome temperature than CFC12. In conclusion, the proposed hydrocarbon mixture seems to be an appropriate candidate to replace CFC12 without causing more environmental problems.

  • PDF

열압축기를 채용한 다중효용 담수설비의 운전특성에 관한 연구(1보) (A Study on the MED-TVC Operating Performance Characteristics of using the Thermo-Compressor)

  • 최두열;김창복;송영호;최순호;정한식;김필환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권8호
    • /
    • pp.1185-1191
    • /
    • 2008
  • The core design technology for the multi-effect desalination plant using the thermo compressor (MED-TVC) was investigated by the performance test of multi effect desalination plant in this paper. The final G.O.R (gain of output ratio) of MED-TVC type desalination plant is strongly affected by the performance of thermo-vapor compressor. The present experiments for the desalinating capacity and G.O.R were obtained for the range of the motive steam pressure, 266.0, 250.0, 230.0 and 200.0 kPa. And as a practical problem, to investigate the influence of the sea water temperature to the G.O.R, the inlet steam temperature of the suction water vapor was changed in the range of $311.2{\sim}324.2$ K in the present experiment. Through the experiments, the maximum value of G.O.R was 8.5 at the condition of the motive steam pressure, 136.0 kPa and the minimum value of G.O.R was 8.1 at the condition of the motive steam pressure, 266.0 kPa. And it was confirmed that the range of desalination capacity was $355.2{\sim}264.0$ ton/day in the normal operation condition.

산삼배양추출물의 ICR 마우스 골수세포를 이용한 복강 투여 소핵시험 (Micronucleus Test of Wild Ginseng Culture Extract Using the Marrow Cells in ICR Mice)

  • 송시환;양덕춘;정세영
    • 한국식품위생안전성학회지
    • /
    • 제20권1호
    • /
    • pp.58-63
    • /
    • 2005
  • 시험물질 산삼배양추출물의 유전독성 평가를 위해 수컷 ICR 마우스 골수세포를 이용한 소핵시험을 실시하였다. 1 회 투여 최고량은 예비 시험에서 결정하였다. 약 7주령의 수컷 마우스에 시험물질 0, 500, 1,000 및 2,000 mg/kg의 용량을 1일 1회 2일간 복강내 투여하고, 최종 투여로부터 약 24시간 후에 골수세포를 수거하여 소핵 유발과 세포독성을 평가하였다. 개체당 2,000개의 다염성적혈구(michromatic erythrocyte, PCE)중에 나타나는 소핵을 가진 다염성적혈구(micronucleated polychromatic erythrocyte, MNPCE)의 수를 계수한 결과, 모든 시험물질 투여군은 음성 대조군에 비해 통계학적으로 유의한 증가는 나타나지 않았으며 일반 증상에서도 모든 시험군은 투여로 인한 것으로 판단되는 증상은 관찰되지 않았다. 부검시 체중에 있어서는 시험물질 최고 용량군에서 유의한 감소가 관찰되었다. 따라서 산삼배양추출물은 위 시험 조건에서, 본 시험에 사용한 마우스 골수세포에 소핵을 유발하지 않는 것으로 사료된다.

간호대학생의 비판적 사고, 셀프리더십이 학습 몰입에 미치는 영향 (Influence of Critical Thinking and Self Leadership on Learning Commitment of Nursing Students)

  • 이미영;김소명
    • 한국응용과학기술학회지
    • /
    • 제37권4호
    • /
    • pp.915-924
    • /
    • 2020
  • 본 연구는 간호대학생의 비판적 사고, 셀프리더십과 학습 몰입 정도를 파악하고, 학습 몰입에 미치는 영향을 확인하고자 시도 되었다. 연구 대상자는 D 광역시, G 광역시에 소재한 2개 간호학과 2학년 학생 196명을 대상으로 하였으며, 2018년 11월 26일부터 12월 7일까지 자료수집하였다. 수집된 자료는 SPSS 21.0 프로그램을 사용하여 기술 통계, t-test, ANOVA, Pearson 상관계수, 다중회귀분석으로 분석하였다. 연구결과 일반적 특성에 따른 학습 몰입은 학교 성적, 전공 만족도, 대인관계에 따라 유의한 차이를 보였고, 학습 몰입은 셀프리더십(r=.738, p<.001)과 유의한 양의 상관관계가 있는 것으로 나타났다. 또한, 학습 몰입에 영향을 미치는 요인은 학교 성적(β=-.212, p=.011), 전공 만족도(β=.248, p=.001), 셀프리더십(β=.598, p<.001)으로 나타났으며, 학습 몰입에 대한 이들 변인의 설명력은 58%로 나타났다. 본 연구 결과를 토대로 간호대학생의 학습 몰입을 향상시키기 위해서는 전공 만족도와 셀프리더십을 증진시킬 수 있는 프로그램 개발이 필요할 것으로 생각한다.

기초의학 통합강의 운영을 위한 가상강의(Cyber Lecture)의 개발 및 적용 - 기초신경과학 통합강의의 운용과 설문을 통한 학생들의 의견을 중심으로 - (Development of Cyber Lecture Contents and Application to the Basic Neuroscience Integrative Lecture for Medical Students)

  • 김지희;박정현;이영일
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2011년도 춘계학술논문집 2부
    • /
    • pp.655-658
    • /
    • 2011
  • 기초의학 강의 요원의 부족은 교육에 대한 부담과 연구활동 위축이라는 이중고를 초래하고 있다. 기초의학 강의의 효율성을 높이기 위하여 다양한 연구 및 해결책이 제시되어 왔으며, 통합강의 역시 그 대안의 하나로서 대두되고 있다. 따라서 본 연구에서는 새롭게 부각되고 있는 기초의학 통합강의에 대한 가상강의(cyber lecture) 적용의 실효성과 타당성을 설문조사와 교과목 운영의 경험을 중심으로 분석하였다. 설문조사에 대해 학생들은 가상강의의 내용, 난이도, 진행 및 멀티미디어 컨텐츠 등에 대해 대체로 만족스러운 의견을 제시하였다. 또한 가상강의가 통합강의 운영을 보완해주는데 효율적일 것이라는 의견과 더불어, 향후 통합강의에서 가상강의의 비중을 학대할 필요성에 대해서도 찬성의견이 반대의견보다 지배적임을 알 수 있었다. 뿐만 아니라, 통합강의 실습의 일부분을 가상강의에서 운영하는 방안에 대해서도 대체로 긍정적이었다. 통계분석 결과, 가상강의에 대해 긍정적이거나 부정적인 의견들은 기초신경학 통합강의 성적이 우수한 학생과 보통이하인 학생들 사이에 유의한 차이를 보이지 않았으나 (${\chi}^2$ 검증 결과), 성적이 우수한 학생일수록 가상강의의 효율성에 대해 긍정적이라는 경향은 알 수 있었다(Spearman 등위상관계수를 산출한 결과). 본 연구결과를 통해 제시된 개선방안과 축적된 경험을 바탕으로 점차 가상강의의 비중을 높이고 강의교수들 간의 유기적 협조가 이루어진다면 가상강의는 향후 기초의학 통합강의 운영의 새로운 패러다임(paradigm)이 될 것으로 사료된다.

  • PDF

미활용 에너지원으로서의 지하철 배열이용에 관한 연구 (Research on using the exhausted heat from subway tunnel as unused energy)

  • 김종렬;금종수;최광환;윤정인;박준택;김동규;김보철;정용현
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.695-701
    • /
    • 1998
  • Researches on unused energy are being continued because of the limited fossil fuel and the destruction of environment. Therefore this study was peformed as follows. The collectable amount of exhausted heat for an air-conditioning was calculated by the subway thermal environment prediction program. And the electric power needed by conventional heat source equipments was compared with one by unused heat source equipments when the exhausted heat was used by heat pump in heating and hot water supplying. The results are summarized as follows; 1) Forced ventilation should be conducted to keep optimal temperature in subway tunnel in summer as well as in winter. According to the simulation, temperature in tunnel was higher than that on the ground in summer when the forced ventilation was conducted only in winter. 2) Ventilating time should be calculated out to the optimal condition for not only saving power of ventilation fan but reusing exhausted heat. By the simulation, it is certain that the exhausted heat should be eliminated in air-conditioning time. 3) The use of exhausted heat source heat pump could save 8% of electric power per hour in comparison with existing heat pump. It was based on a present heat generation and traffic for ventilating time of general air-conditioning, but could be different by ventilating time. 4) As the traffic increases up to 1.5 or 2 times, electric power consumption of the conventional heat pump increases to 11% or 13.5% per mean hour in comparison with that of the exhausted heat source heat pump, though all-day ventilation.

  • PDF

Psychosocial Wellbeing Index의 신뢰도 및 타당도 (Reliability and Validity of PWI(Psychosocial Wellbeing Index))

  • 이채용;이종영
    • Journal of Preventive Medicine and Public Health
    • /
    • 제29권2호
    • /
    • pp.255-264
    • /
    • 1996
  • 정상적으로 일상생활을 영위하는 사람들을 대상으로 스트레스 수준을 가늠하고, 스트레스에 대한 조정기전을 밝히고자 하는 목적으로 개발된 사회 심리적 건강 측정 도구(PWI)의 신뢰도 및 타당도를 평가하기 위하여, 의과 대학생을 대상으로 4주간격으로 두 차례의 설문 조사를 실시하였다. 내적 일치도를 나타내는 Crohnbach's $\alpha$계수가 0.93의 값을 보였다. 4주의 간격을 둔 검사-재검사 신뢰도는 1차조사의 성적과 2차조사의 성적 사이 Pearson상관계 수가 0.72의 값을 보였다. 탐색적 인자 분석을 통해 고유값 1이상의 인자는 13개였다. 인자의 수를 4개로 지정하여 주축인자법과 직교 회전법으로 분석하여 인자 구조를 비교한 결과 첫번째 인자는 거의 일치하였으나, 3번째와 4번째 인자는 거의 일치하지 않았다. 확증적 인자분석을 통해 선행 연구의 4인자 모형과 이 연구의 탐색적 분석 결과에 나타난 4인자 모형의 적합도를 구한 결과 RMR값이 0.1미만인 것을 제외하고는 모든 적합도 지수가 부적합하게 나왔다 각 인자를 측정 변수로 간주하고 그 하부에 이론 변수로서 단일 인자가 존재하는 것으로 구성한 일차원적 단일 인자 모형에 대한 적합도는, 비록 이 모형이 오차 항의 상관성을 지닌 것이긴 하나 적합한 지수를 많이 보여, PWI가 2차원적 측정 구조를 가졌을 가능성을 제시하였다.

  • PDF

열음향 냉동기의 설계 및 개발 : I. 내부공간의 음향해석 및 에너지 변환 예측 (Design and Development of Thermoacoustic Rdfrierator : I. Acoustic Analysis of Resonator and Prediction of Energy Conversion)

  • 박철민;이정권
    • 한국음향학회지
    • /
    • 제15권5호
    • /
    • pp.44-52
    • /
    • 1996
  • 열음향 냉동기의 설계시 요구되는 냉동기의 내부음장 특성을 예측하기 위해, 냉동기를 이루는 공명기 구조 및 선형화된 스피커의 모델에 대행 전달행렬기법을 이용하여 해석을 수행하였다. 여러 가지 기본 음향요소들의 전달행렬을 이용하여 공명기를 음향학적 요소들로 분해하고, 스피커의 선형화된 동특성 방정식과 함께 해석함으로써 음향요소들이 직렬로 배열되어 있는 공명기에 대한 음향특성을 얻어 내었다. 또한, 열음향 냉동기의 개발에 있어서 중요한 목표중 하나인 모세관 스택에서의 온도차이를 에너지 방정식을 이용하여 수치적으로 예측하였다. 한 개의 모세관 기공내에서의 음향일의 흐름, 열음향 흐름, 단위 길이당 에너지 손실 등을 단면변화함수를 이용해 표시한 후, 전체 스택에서의 에너지 흐름과 열평형을 고려하였다. 전체 스택에서의 에너지 흐름에 관한 식에 대하여, 내부음장 예측에 의해 구한 물리량을 이용하여, 수치적인 반복계산을 수행함으로써 온도비 및 성적계수를 예측할 수 있었다. 실제 설계된 공명기의 음향 특성의 해석결과가 실험과 잘 일치함을 관찰한 후, Hofler의 열음향냉동기에 대한 열음향 해석을 수행하여 실험결과와 잘 부합됨을 확인할 수 있었다.

  • PDF

제 2종 LiBr-H2O 흡수식 히트펌프의 운전 변수에 따른 성능 특성 수치 해석 (Effects of Operation Conditions on the Performance of Type II LiBr-H2O Absorption Heat Pump)

  • 윤준성;권오경;차동안;배경진;김인관;김민수;박찬우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.7-14
    • /
    • 2017
  • This study carried out a numerical analysis of the effects of hot waste water supply on the performance of a Type II absorption heat pump. There are two types of hot waste water supply, regular series flow and reverse series flow. Also it investigated the interaction between each type of flow and heat exchange solutions. As the effectiveness of heat exchange solutions increase, the steam generation and (COP) increase as well. If the effectiveness of a heat exchange solution is lower than 0.566, the steam generation rate of the reverse flow is lower than that of the regular series flow. A high effectiveness of heat exchange solution is therefore required to make a larger amount of steam in reverse series flow than with ordinary series flow. The COP difference between the two types of flow decreases with the increasing effectiveness of the heat exchange solution. Thus, a reverse flow type absorption heat pump can match the high steam generation rate and COP of the ordinary flow type when a highly effective heat exchange solution is applied.

냉매 과냉각 시스템을 이용한 열펌프의 성능향상에 관한 연구 (Performance Enhancement of the Heat Pump Using the Refrigerant Subcooling System)

  • 손창효;윤찬일;박승준;이동건;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 춘계학술대회 논문집
    • /
    • pp.106-111
    • /
    • 2001
  • The performance characteristics of heat pump system using the new refrigerant subcooling system were investigated. The new heat pump system has the ice storage tank to accumulate the latent heat of the refrigerant during the night-time. The heat is released to subcool the saturated refrigerant liquid at the outlet of a condenser in the daytime. The experimental apparatus is a well-instrumented heat pump which consisted of a refrigerant loop and a coolant loop. The test sections(condenser and evaporator) were made of tube-in-tube heat exchanger with the horizontal copper tube of 12.7[mm] outer diameter and 9.5[mm] inner diameter. The evaporating temperatures ranged from $-5[^{\circ}C]$ to $0[^{\circ}C]$ and the subcooling degrees of the refrigerant varied from $15[^{\circ}C]$ to $25[^{\circ}C]$. The test of the ice storage was carried out at evaporating temperature of $-10[^{\circ}C]$ and the ice storage mode is an ice-on-coil type. The main results were summarized as follows ; The refrigerant mass flow rate and compressor shaft power of the heat pump system were independent of the subcooling degrees. The cooling capacity o the heat pump system increases as the evaporating temperature and subcooling degree increases. The cooling capacity of the heat pump system is about 25 to 30% higher than that of normal heat pump system. The COP of the heat pump system which subcooled the refrigerant liquid at the outlet of the condenser is about 28% higher than that of the normal heat pump system.

  • PDF