• Title/Summary/Keyword: 성능비

Search Result 17,183, Processing Time 0.058 seconds

Effects of Green Tea Catechin on Microsomal Phospholipase A2 Activity and Arachidonic Acid Cascade in Rat Lung Exposed to Microwave (마이크로웨이브를 조사한 흰쥐 폐조직의 Phospholipae A2 활성과 Arachidonic Acid Cascade계에 미치는 녹차 Catechin의 영향)

  • Kim, Mi-Ji
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.7
    • /
    • pp.936-942
    • /
    • 2012
  • In the present study, the effects of green tea catechin on microsomal phospholipase $A_2$ ($PLA_2$) activity and the arachidonic acid (AA) cascade in the lungs of microwave exposed rats were investigated. One Sprague-Dawley male rats weighting $100{\pm}10$ g was randomly assigned to the normal group and three were assigned to the microwave exposed groups. The microwave exposed groups were subdivided into three groups according to the levels of dietary catechin supplementation: catechin free diet (MW) group, 0.25% catechin (MW-0.25C) group and 0.5% catechin (MW-0.5C) group. Rats were sacrificed on the 6th day after microwave irradiation (2.45 GHz, 15 min). The lung microsomal $PLA_2$ activity in the MW and MW-0.25C groups was 30% and 15% greater than that of the normal group, respectively, whereas no significant difference between the normal group and MW-0.5C group was observed. The percentage of phosphatidylethanolamine (PE) hydrolyzed in the lung microsome in the MW, MW-0.25C and MW-0.5C group increased by 47%, 18% and 20%, respectively, due to microwave irradiation. The formation of thromboxane $A_2$ ($TXA_2$) in the lung microsome was 50% greater in the MW group than in the normal group. However, the levels of $TXA_2$ in the MW-0.25C and MW-0.5C group were normal. The formation of prostacyclin ($PGI_2$) in the lung microsome was 31% lower in the MW group than in the normal group, while the levels of $PGI_2$ in the MW-0.25C and MW-0.5C group were similar to the normal group. The lung microsomal thiobarbituric acid reactive substances (TBARS) concentration, which can be used as an index of lipid peroxide was 34% greater in the MW group, when compared with the normal group. However, there was no difference between the MW-0.25C, MW-0.5C and normal groups. In conclusion, lung function appeared to be improved by green tea catechin supplementation due to its antithrombus action, which in turn controls the AA cascade system.

Dual Codec Based Joint Bit Rate Control Scheme for Terrestrial Stereoscopic 3DTV Broadcast (지상파 스테레오스코픽 3DTV 방송을 위한 이종 부호화기 기반 합동 비트율 제어 연구)

  • Chang, Yong-Jun;Kim, Mun-Churl
    • Journal of Broadcast Engineering
    • /
    • v.16 no.2
    • /
    • pp.216-225
    • /
    • 2011
  • Following the proliferation of three-dimensional video contents and displays, many terrestrial broadcasting companies have been preparing for stereoscopic 3DTV service. In terrestrial stereoscopic broadcast, it is a difficult task to code and transmit two video sequences while sustaining as high quality as 2DTV broadcast due to the limited bandwidth defined by the existing digital TV standards such as ATSC. Thus, a terrestrial 3DTV broadcasting with a heterogeneous video codec system, where the left image and right images are based on MPEG-2 and H.264/AVC, respectively, is considered in order to achieve both high quality broadcasting service and compatibility for the existing 2DTV viewers. Without significant change in the current terrestrial broadcasting systems, we propose a joint rate control scheme for stereoscopic 3DTV service based on the heterogeneous dual codec systems. The proposed joint rate control scheme applies to the MPEG-2 encoder a quadratic rate-quantization model which is adopted in the H.264/AVC. Then the controller is designed for the sum of the left and right bitstreams to meet the bandwidth requirement of broadcasting standards while the sum of image distortions is minimized by adjusting quantization parameter obtained from the proposed optimization scheme. Besides, we consider a condition on maintaining quality difference between the left and right images around a desired level in the optimization in order to mitigate negative effects on human visual system. Experimental results demonstrate that the proposed bit rate control scheme outperforms the rate control method where each video coding standard uses its own bit rate control algorithm independently in terms of the increase in PSNR by 2.02%, the decrease in the average absolute quality difference by 77.6% and the reduction in the variance of the quality difference by 74.38%.

Heating Performance of Hot Water Supplying System in Greenhouse (온수배관을 이용한 온실의 난방성능)

  • Yoon, Yong-Cheol;Shin, Yik-Soo;Kim, Hyeon-Tae;Bae, Seoung-Beom;Choi, Jin-Sik;Suh, Won-Myung
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.79-87
    • /
    • 2012
  • This research was conducted to obtain basic data with regard to the heating performance that would be produced by installing an aluminum hot water pipe inside the greenhouse with the goal of reducing the heating energy in greenhouse. The research results are summarized as follows. The degree of difference in relation to the temperature by height within the greenhouse during the entire experiment was significant - within the range of 4.0~$7.0^{\circ}C$. The temperature difference between incoming and outgoing water was about $3.3^{\circ}C$ greater when FCU was activated compared to when it was not activated. Meanwhile, the amount of energy consumed increased about 36.2~40.1%. The amount of pyrexia per hour also increased by 44.6~52.0%. During the experiment period, circulated flux was within the range of 0.48~$0.49L{\cdot}s^{-1}$ while average fluid speed was 1.53~$1.56m{\cdot}s^{-1}$. The average temperature difference between incoming and outgoing water was 6.24~$11.50^{\circ}C$. The amount of heating value by each set temperature within the minimum outdoor temperature range of -14.0~$-0.6^{\circ}C$ was 135,930~307,150 kcal, and the range was within the 9,610~$19,630kcal{\cdot}h^{-1}$ per hour. This demonstrated that about 23~53% heating energy of the maximum heating load could be supplied. Total radiating value and amount of energy consumed were 2,548,306 kcal and 3,075.7 kWh, respectively. When heating takes place using oil, which is a fossil fuel, the total amount of light oil consumed was 281.6 L while the cost was 321,000 won. When the electricity cost for farms is applied, the total cost was about 110,730 won, which is about 33.5% of the cost required compared to oil consumption. The temperature at in the experiment area was about 8.3~$14.6^{\circ}C$ higher compared to that of the control area.

Development of Two-dimensional Prompt-gamma Measurement System for Verification of Proton Dose Distribution (이차원 양성자 선량 분포 확인을 위한 즉발감마선 이차원분포 측정 장치 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Chan Hyeong;Kim, Sung Hun;Kim, Seonghoon;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.42-51
    • /
    • 2015
  • In proton therapy, verification of proton dose distribution is important to treat cancer precisely and to enhance patients' safety. To verify proton dose distribution, in a previous study, our team incorporated a vertically-aligned one-dimensional array detection system. We measured 2D prompt-gamma distribution moving the developed detection system in the longitudinal direction and verified similarity between 2D prompt-gamma distribution and 2D proton dose distribution. In the present, we have developed two-dimension prompt-gamma measurement system consisted of a 2D parallel-hole collimator, 2D array-type NaI(Tl) scintillators, and multi-anode PMT (MA-PMT) to measure 2D prompt-gamma distribution in real time. The developed measurement system was tested with $^{22}Na$ (0.511 and 1.275 MeV) and $^{137}Cs$ (0.662 MeV) gamma sources, and the energy resolutions of 0.511, 0.662 and 1.275 MeV were $10.9%{\pm}0.23p%$, $9.8%{\pm}0.18p%$ and $6.4%{\pm}0.24p%$, respectively. Further, the energy resolution of the high gamma energy (3.416 MeV) of double escape peak from Am-Be source was $11.4%{\pm}3.6p%$. To estimate the performance of the developed measurement system, we measured 2D prompt-gamma distribution generated by PMMA phantom irradiated with 45 MeV proton beam of 0.5 nA. As a result of comparing a EBT film result, 2D prompt-gamma distribution measured for $9{\times}10^9$ protons is similar to 2D proton dose distribution. In addition, the 45 MeV estimated beam range by profile distribution of 2D prompt gamma distribution was $17.0{\pm}0.4mm$ and was intimately related with the proton beam range of 17.4 mm.

Water Treatment Application of a Large Pore Micro-Filtration Membrane and Its Problems (대기공 정밀여과막의 수처리 응용 및 문제점)

  • Yun, Chang-Han;Kim, Jeong-Hak;Lee, Kang Won;Park, Sung Ho
    • Membrane Journal
    • /
    • v.24 no.3
    • /
    • pp.194-200
    • /
    • 2014
  • The purpose of this study was to evaluate the performance of newly developed Large Pore Micro-Filtration (LPMF) membrane in Lab size for the application of water treatment, and to find its problems with solutions. The out-to-inside filtration hollow fiber LPMF membrane of which average pore size was $5{\mu}m$ was used at this study and its material was the PET braid reinforced PVDF. Filtration tests were done through gravity with 30 cm water head difference or pressure below 1.5 bar, and the backwash was done instantaneously with the filtrate after pressurizing it to about 4 bar. The water flux of the LPMF membrane with 0.2 bar TMP (Trans Membrane Pressure) was 2 times higher than $0.4{\mu}m$ MF membrane with $0.05{\mu}m$ UF filtrate of the tap water and it was measured also with 20~30 cm water head difference which showed over 800 LMH at 30 cm water head difference. And Time-To-Filter (TTF) was performed by using $5{\mu}m$ filter paper to optimize coagulants and dosage which enhanced filtrate's turbidity and stabilized filtration flux. When the LPMF was operated with 30 cm gravity with very high dose of inorganic coagulants, the flux was maintained over 80 LMH with 93.5~99.5% turbidity removal. Especially, the filtration was maintained stably in the flux and about 97% of the recovery rate by instantaneous pressurized backwash with about 4 bar of the filtrate when the packing density was about 19%. But there was instability in filtration, since the TMP was continuously going up by inefficient backwash when the packing density was 43%.

The New Design Concept Paradigm for the 21st Korea Optical Industry (21세기 한국 안경 산업에 있어서 새로운 Design Concept의 전환)

  • Park, S.O.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.45-50
    • /
    • 2002
  • The 'hands-on' craftsmanship of the 20th century has came and gone. Today, we are dealing with whole new, 'cerebral approach,' to concept and design with this new approach, design and function are very much dependant upon planning, sales, promotion, and the formative technique of the design industry. The innovative process of design constantly change as it reflects the needs and wants of society. It is and industry that constantly change as it reflects the needs and wants of society. It is and industry that constantly remakes and reshapes itself to suit current trend and outlook. The current idea being that consumers are looking for quality over quantity. Due to the 20th centuries dominant philosophy of functionalism, production intended to standardize the individual's purchasing choice. Aesthetic, or philosophic qualities played a second fiddle to the functional bias of a product, With production, Marketing, and research and development are integrated into the management process. This translates as good which include efficiency, quality, durability, and credibility an trademark and style. There is a definite 'post-modernist' movement and style in 21st century. Every possibility is available as the old boundaries of the 20th century are laid aside. There is a new, transformative quality to the current paradigm of design. The old "should" and "should not" of design no longerapplies. The integrated rative of design solves the usual disparity between aesthetic qualities and production. Design and profirability need not be stranger to one another. It can differentiate the image perceived of both enterprises and consumers by making use of integrated goods services. With an integrated system. both producers and designers win. While design gets full access to design in turn. All consumers make decisions based upon the evaluation of quality, service, and image ; even though it may not be a conscious decision to do so. Consumers are fully integrated human beings ; therefore producers who apply the new, integrated paradigmatic approach to concept, design, and production will reap the harvest of making a true relationship with individual buyer.

  • PDF

Processing of Ready-to-Cook Food Materials with Dark Fleshed Fish 1, Processing of Ready-to-Cook Sardine Meat "Surimi" (일시다획성 적색육어류를 이용한 중간식품소재 개발에 관한 연구 1. 정어리 연육의 가공)

  • LEE Byeong-Ho;LEE Kang-Ho;YOU Byeong-Jin;SUH Jae-Soo;JEONG In-Hak;JUNG Woo-Jin;KANG Jeong-Oak
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.5
    • /
    • pp.401-408
    • /
    • 1985
  • In order to develop new types of product which can offer a sanitary and preservative duality, and convenience to consumers in marketing and cooking particularly in urban area, two processing methods of ready-to-cook food materials with dark fleshed fishes like sardine and mackerel were investigated. A method applied, in this work, is processing of ready-to-cook sardine meat "surimi" in which sardine meat is treated with alkaline solution to stabilize myofibrillar proteins, washed thoroughly with water to remove soluble components, and added with a proper amount of polyphosphate and sorbitol to enforce the functional property of meat such as water holding capasity, elasticity, and gel strength. The textural properties of fish meat paste made from the "surimi" meat were greatly dependent upon the stability of myofibrillar proteins and the elimination of water soluble components. The salt soluble proteins of sardine meat were so unstable in post-mortem stage that the gel forming ability was lost within 3 days at $5^{\circ}C$ storage and 2 to 3 weeks even at $-20^{\circ}C$ although the freshness was well kept for a week at $5^{\circ}C$ and several months of storage at $-20^{\circ}C$. A proper way of treatment to keep the proteins stable was that fish meat must be washed with $0.4\%$ sodium bicarbonate solution followed by 3 to 4 times washing with water. This resulted in removal of $80\%$ water soluble proteins and 50 to $60\%$ lipids. The addition of polyphosphate and sorbitol affected the stability of proteins during the storage of "surimi" meat. When phosphate and sorbitol were added in the ratio of $0.3\%:\;0.3\%,\;0.6\%:\;3\%,\;0.6\%:\;6\%,\;0:\,0.3\%\;and\;0.3\%:\;0$, the gel forming ability terminated in 35 days, 21 days, 14 days, 14 days, and 14 days of storage at $-30^{\circ}C$, respectively, while that of the control was 7 days. And it was also noteworthy that at least 8.0 mg/g of salt soluble protein nitrogen content was required for gel formation.

  • PDF

Effect of Added NH$_3$ to AMP on Absorption Rate for Simultaneous Removal of CO$_2$/NO$_2$ in Composite Absorption Process (복합흡수공정에서 CO$_2$/NO$_2$ 동시제거 시 AMP(2-amino-2-methyl-1-propanol)에 Ammonia 첨가가 흡수속도에 미치는 영향)

  • Seo, Jong-Beom;Choi, Won-Joon;Moon, Seung-Jae;Lee, Gou-Hong;Oh, Kwang-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.12
    • /
    • pp.1287-1293
    • /
    • 2008
  • In this study, a blend of 2-amino-2-methyl-1-propanol (AMP) and ammonia (NH$_3$) was used to achieve high absorption rates for carbon dioxide (CO$_2$) as suggested at several literatures. The absorption rates of aqueous AMP and blended AMP+NH$_3$ solutions with CO$_2$ and nitrogen dioxide (NO$_2$) were measured using a stirred-cell reactor at 303 K. The effect of the added NH$_3$ to enhance absorption characteristics of AMP was studied. The performances were evaluated under various operating conditions. The absorption rates increased following the increase of the concentration of NH$_3$. The absorption rate of NH$_3$ blended into 30 wt.% AMP solution with NO$_2$ at 303 K was 12.6$\sim$32.6% higher than that of aqueous AMP solution without NH3. Also, the addition of 3 wt.% NH$_3$ to 30 wt.% AMP increased 48.2$\sim$41.6% values for the reactions with CO$_2$ and NO$_2$ at 303 K. Therefore, it clearly shows that the reaction rate of AMP with CO$_2$ and NO$_2$ can be increased by the addition of NH$_3$.

A Study on the Necessity of Verification and Certification System of Inspection and Diagnostic Equipment for Infrastructure using Advanced Technologies (첨단 시설물 점검 및 진단장비 검·인증제도 도입 필요성에 대한 연구)

  • Hong, Sung-Ho;Kim, Jung-Gon;Cho, Jae-Young;Kim, Twae-Hwan
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.163-177
    • /
    • 2020
  • Purpose: While it is very important to maintain facilities recently, the introduction and its application of high technology in the facility maintenance industry has increased. It is necessary for high technology to secure reliability through the verification and certification system of diagnostic equipment to have an effective impact in the field, but there is difference between the industry's perspective and realistic level of technology apart from social demand for the system of the system. This paper dealt with the introduction of a verification and certification system for rational facility diagnostic equipment with the opinion survey on managers about the current situation. Method: Survey is carried out targeting managers in the maintenance and construction regarding the necessity and urgency of introducing a verification and certification system to promote the introduction and its application of high technology of diagnostic equipment and facility inspection. Also, the introduction to a verification and certification system was reviewed for advanced facility diagnostic equipment through foreign research about similar systems and comparative analysis of similar systems related to the certification of 21 domestic equipment. Result: It showed that, regarding the application of high technology, it is necessary for most managers to introduce high technology such as drones, robots, etc., in the maintenance industry, and when high technology is introduced, it will have a considerable effect in the field. On the other hand, the current technology level in Korea is relatively low, so it turned out to take a certain amount of time for the application of technology. Also, it was found that the management of reliable facility diagnostic equipment will be possible through the introduction of the verification and certification system for facility diagnosis equipment. Meanwhile, the survey is conducted on similar systems about foreign and domestic diagnosis and measuring equipment, etc., but there is no system to verify and certify equipment applied with high technology directly to facility diagnosis maintenance. However, because Japan has a system of verifying the performance of diagnostic equipment and South Korea has 21 similar inspection and diagnostic equipment certification systems among 186 certification systems, it is considered to be possible to design systems which utilize them. Conclusion: According to the managers' opinion, it seems that the introduction of the system supporting the application of 4th industrial technology for the equipment and the use of the equipment with high reliability has sufficient validity. However, because our high technology level is undervalued compared to the urgency, the system for checking high technology facilities and certifying diagnostic equipment should be to be implemented in form of escalation considering technical use and verification level. Apart from the introduction of the verification and certification system, it is necessary for special investment, support and efforts to promote advanced facility diagnostic equipment.

Comparison of Human Sodium/Iodide Symporter (hNIS) Gene Expressions between Lentiviral and Adenoviral Vectors in Rat Mesenchymal Stem Cells (렌티바이러스와 아데노바이러스를 통하여 쥐의 중간엽줄기세포에 사람 나트륨/옥소 공동수송체 유전자를 전달하였을 때의 발현성능 비교)

  • Park, So-Yeon;Kim, Sung-Jin;Lee, Won-Woo;Lee, Heui-Ran;Kim, Hyun-Joo;Chung, June-Key;Kim, Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.394-400
    • /
    • 2008
  • Purpose: Quantitative comparison of transgene expression within stem cells between lentivirus and adenovirus-mediated delivery systems has not been reported. Here, we evaluated the human sodium iodide symporter (hNIS) gene expression in rat mesenchymal stem cell (rMSC) transduced by lentivirus or adenovirus, and compared the hNIS expression quantitatively between the two delivery systems. Materials and Methods: Lentiviral-mediated hNIS expressing rMSC (lenti-hNIS-rMSC) was constructed by cloning hNIS gene into pLenti6/UbC/V5-DEST (Invitrogen) to obtain pLenti-hNIS, transducing rMSC with the pLenti-hNIS, and selecting with blasticidin for 3 weeks. Recombinant adenovirus expressing hNIS gene (Rad-hNIS) was produced by homologous recombination and transduction efficiency of Rad-hNIS into rMSC evaluated by Rad-GFP was $19.1{\pm}4.7%$, $54.0{\pm}6.4%$, $85.7{\pm}8.7%$, and $98.4{\pm}1.3%$ at MOI 1, 5, 20, and 100, respectively. The hNIS expressions in lenti-hNIS-rMSC or adeno-hNIS-rMSC were assessed by immunocytochemistry, western blot, and 1-125 uptake. Results: Immunocytochemistry and western blot analyses revealed that hNIS expressions in lenti-hNIS-rMSC were greater than those in adeno-hNIS-rMSC at MOI 20 but lower than at MOI 50. However in vitro 1-125 uptake test demonstrated that iodide uptake in lenti-hNIS-rMSC ($29,704{\pm}6,659\; picomole/10^6\;cells$) was greater than that in adeno-hNIS-rMSC at MOI 100 ($6,168{\pm}2,134\;picomole/10^6\;cells$). Conclusion: Despite lower amount of expressed protein, hNIS function in rMSC was greater by lentivirus than by adenovirus mediated expression. Stem cell tracking using hNIS as a reporter gene should be conducted in consideration of relative vector efficiency for transgene expression.