• Title/Summary/Keyword: 성능기반 규정

Search Result 119, Processing Time 0.023 seconds

Frame Synchronization Algorithm based on Differential Correlation for Burst OFDM System (Burst OFDM 시스템을 위한 차동 상관 기반의 프레임 동기 알고리즘)

  • Um Jung-Sun;Do Joo-Hyun;Kim Min-Gu;Choi Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.10C
    • /
    • pp.1017-1026
    • /
    • 2005
  • In burst OFDM system, the frame synchronization should be performed first for the acquisition of received frame and the estimation of the correct FFT-window position. The conventional frame synchronization algorithms using design features of the preamble symbol, the repetition pattern of the OFDM symbol by pilot sub-carrier allocation rule and Cyclic Prefix(CP), has difficulty in the detection of precise frame timing because its correlation characteristics would increase and decrease gradually. Also, the algorithm based on the correlation between the reference signal and the received signal has performance degradation due to frequency offset. Therefore, we adopt a differential correlation method that is robust to frequency offset and has the clear peak value at the correct frame timing for frame synchronization. However, performance improvement is essential for differential correlation methods, since it usually shows multiple peak values due to the repetition pattern. In this paper, we propose an enhanced frame synchronization algorithm based on the differential correlation method that shows a clear single peak value by using differential correlation between samples of identical repeating pattern. We also introduce a normalization scheme which normalizes the result of differential correlation with signal power to reduce the frame timing error in the high speed mobile channel environments.

Accuracy Analysis of FKP for Public Surveying and Cadastral Resurvey (공공측량 및 지적재조사 사업 적용을 위한 FKP 정밀도 분석)

  • Park, Jin Sol;Han, Joong-Hee;Kwon, Jay Hyoun;Shin, Han Sup
    • Spatial Information Research
    • /
    • v.22 no.3
    • /
    • pp.23-24
    • /
    • 2014
  • NGII (National Geographic Information Institute) has been providing VRS (Virtual Reference Station) service so that could determine precise positioning in real time since 2007. However, since the VRS service has to maintain the connected status with VRS server, the number of users who can use VRS service are limited by capacity of VRS server. To solve this problem, NGII has been providing FKP (Virtual Reference Station) service using one way telecommunication from November 1, 2012. Therefore, it is predicted that the usage of FKP service will increase in public surveying and cadastral resurveying in the future. However, the studies with respect to analysis of FKP precision for applying to public surveying and cadastral resurveying is not conducted enough. In this study, to analyse the application possibility of FKP on the public surveying and cadastral resurveying, the two kind analysis were performed. First is the analysis of accuracy according to the configuration of reference station of FKP and VRS. One is consisted of same reference stations, another is consisted of different reference stations. Second is the accuracy anlalysis of horizontal and vertical positioning acquiring VRS and FKP data in various measurement environment based on VRS regulation. Result of first study, Positioning accuracy according to the configuration of the reference stations satisfies related regulation. However, accuracy of FKP in case of different reference stations is worse than in case of same reference stations.. The result of second test shows that the horizontal precision of FKP and VRS in good measurement environment satisfy the allowed precision. However, in some case, horizontal precision of FKP and VRS in poor measurement environment exceed the allowed precision. In addition, the number of exceeding the allowed precision in the FKP is more than the VRS. The vertical precision of the VRS satisfy related work provision. In conclusion, the result of this study shows that the FKP only in open area should be used for public survey and cadastral resurvey. Therefore the additional studies with respect to the improvement of FKP precision should be conducted.

MAC Schemes for Best Effort Service in Wireless MAN: Design and Performance Analysis (무선 MAN에서 Best Effort 서비스를 위한 MAC 방식의 설계 및 성능 분석)

  • Park, Jin-Kyung;Shin, Woo-Cheol;Ha, Jun;Choi, Cheon-Won
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.11 s.353
    • /
    • pp.128-140
    • /
    • 2006
  • In the IEEE 802.16 Wireless MAN standard specifies the air interface of fixed point-to-multipoint broadband wireless access systems providing multiple services. Among the service classes supported between the base station and subscriber stations in the wireless MAN, the best effort service class is ranked on the lowest position in priority and is assisted by a MAC scheme based on reservation ALOHA. The wireless MAN standard, however, does not reveal every detail of the MAC scheme but only describes the skeleton of the MAC scheme. Focusing on the amount of resource that a subscriber demands by a request and the amount of resource that the base grants to a request we thus present a number of resource demand rules and resource grant rules. Also, we construct a candidate MAC scheme by implanting a pair of resource demand and grant rules into the skeleton of the MAC scheme. Meanwhile a difficult situation for the best effort service is expected wherein only scarce resource is available after most of the resource is already preempted by other services. Perceiving such a situation, we evaluate the throughput and delay performance of each candidate MAC scheme. Especially we develop an analytical method to approximately calculate the throughput in the saturated environment. From the numerical results, we observe that the candidate MAC scheme which adopts the non-gated exhaustive demand rule paired with the full grant rule attains superior performance at the expense of the fairness.

Limited Cost-Based Competition and the Cost Distortion Factor - How Real Variable Costs are Reported in Cost-Base Pool of Korean Power Market - (원가기반 제한경쟁과 비용왜곡 요인 -변동비 반영 전력시장에서의 실제변동비 반영사례를 중심으로-)

  • Kim, Myung-Seok;Cho, Sung Bong
    • Environmental and Resource Economics Review
    • /
    • v.23 no.3
    • /
    • pp.497-513
    • /
    • 2014
  • Rate-of-return regulation where a regulator compensates the utilities based upon the cost incurred the regulated companies have the incentive to over-report cost level. However, in case of cost-based competition where a regulator knows the cost of each plant involved and induce the competition among them, one can encounter prisoner's dilemma situation in the short run where the regulated firms under-report cost level. For instance, in case of cost-based pool, a generator may have a strategic behavior to keep its registered variable cost higher than the actual level to maintain its operation rate and generation amounts higher. Eventually, however, such behavior decrease the profitability of a generator and discourage new entry jeopardizing required level of capacity reserves. This is a typical Prisoner's Dilemma situation. The power market operating rule should be revised so that generators' registered variable cost reflect actual level of variable cost.

FPGA Modem Platform Design for eHSPA and Its Regularized Verification Methodology (eHSPA 규격을 만족하는 FPGA모뎀 플랫폼 설계 및 검증기법)

  • Kwon, Hyun-Il;Kim, Kyung-Ho;Lee, Chung-Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.2
    • /
    • pp.24-30
    • /
    • 2009
  • In this paper, the FPGA modem platform complying with 3GPP Release 7 eHSPA specifications and its regularized verification flow are proposed. The FFGA platform consists of modem board supporting physical layer requirements, MCU and DSP core embedded control board to drive the modem board, and peripheral boards for RF interfacing and various equipment interfaces. On the other hand, the proposed verification flow has been regularized into three categories according to the correlation degrees of hardware-software inter-operation, such as simple function test, scenario test call processing and system-level performance test. When it comes to real implementations, the emulation verification strategy for low power mobile SoC is also introduced.

A 3D visualization method for mobile interface based on user's menu preference (사용자 메뉴 선호도 기반 모바일 인터페이스 3D 시각화 기법)

  • Yu, Seok-Jong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.7
    • /
    • pp.49-55
    • /
    • 2010
  • The analysis of menu preference by different users is one of the important issues in mobile interface design. Current mobile phones do not provide any functionalities to customize the user interface based on use history after they are released by manufacturers or mobile carriers. Though a number of functions are loaded into mobile devices, all the menus are uniformly presented to users regardless of menu preference, and it becomes a reason to decrease the usability of mobile interface. To improve this limitation, this paper suggests how to apply 3D visualization methods to mobile interface, depending on menu use history. In addition, for performance evaluation, 3D mobile interface system was implemented using 3D visualization methods such as depth, transparency, and animation. Finally, experiments for performance evaluation were performed in order to measure and compare menu search times.

A Study on Certification System for Aircraft Engines and Auxiliary Power Units (항공기 엔진 및 보조동력장치 인증제도 현황)

  • Lee, Eunhee;Lee, Kang-Yi;Kim, Jinhee
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.194-197
    • /
    • 2017
  • Aircraft engine and auxiliary power units are certified in processes of design, production according to airworthiness requirements. The aircraft engines shall demonstrate compliance with the design and production through the Type Certificate and the auxiliary power unit shall demonstrate compliance with the design and production through the Technical Standards Order Approval. MOLIT(Ministry of Land, Infrastructure and Transport) established the law and the airworthiness requirements for aircraft engines such as KAS Part 33 but didn't issue the Technical Standards Order for auxiliary power unit. In this paper, we proposed and explained the plan for improvement of our aircraft engines industry through building and expanding the certification infra-structure for aircraft engines and auxiliary power unit.

  • PDF

A Framework to Evaluate Communication Quality of Operators in Nuclear Power Plants Using Cosine Similarity (코사인 유사도를 이용한 원자력발전소 운전원 커뮤니케이션 품질 평가 프레임워크)

  • Kim, Seung-Hwan;Park, Jin-Kyun;Han, Sang-Yong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.9
    • /
    • pp.165-172
    • /
    • 2010
  • Communication problems have been regarded as one of the biggest causes in trouble in many industries. This led to extensive research on communication as a part of human error analysis. The results of existing researches have revealed that maintaining a good quality of communication is essential to secure the safety of a large and complex process system. In this paper, we suggested a method to measure the quality of communication during off-normal situation in main control room of nuclear power plants. It evaluates the cosine similarity that is a measure of sentence similarity between two operators by finding the cosine of the angle between them. To check the applicability of the method to evaluate communication quality, we compared the result of communication quality analysis with the result of operation performance that was performed by operators under simulated environment.

Effects of the Recycled Waste Rope Fibers on the Strength and Carbonation Resistance of Cementitious Composites (폐로프 재활용 섬유보강 시멘트 복합체의 탄산화가 강도에 미치는 영향)

  • Sanghwan Cho;Taek Hee Han;Min Ook Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.407-415
    • /
    • 2023
  • In this study, a carbonation test was conducted on cementitious composites reinforced with recycled waste rope fibers (W series) according to EN 12390-12 standards. The test results were compared to those of commercially available polypropylene fibers (P series). In the carbonation test, both the carbonation depth and area were significantly influenced by the water-to-cement ratio. Notably, the carbonation resistance performance of cementitious composites containing waste rope fibers surpassed that of commercially available PP fibers under equivalent conditions. Throughout the 250-day test period, the W series exhibited higher compressive strength values than the P series, while both series displayed a similar trend of strength increase during the same duration. During the initial stage, the W series exhibited flexural strength levels similar to those of the P series. However, in the later stages, the P series showed a higher mean flexural strength by 1.0 MPa.

A Study on the Introduction of Performance Certification System of Inspection and Diagnostic Equipment for Infrastructure (시설물 진단장비의 성능인증제 도입에 관한 연구)

  • Hong, Sung-Ho;Kim, Jung-Gon;Cho, Jae-Young;Kim, Do-Hyoung;Kim, Jung-Yeol;Kim, Young-Min
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.104-115
    • /
    • 2022
  • Purpose: Infrastructure inspection and its diagnostics technique have been rapidly developing recently. Therefore, it is important to secure the reliability of diagnostic equipment, and this paper deals with inspection of diagnostic equipment, introduction to a certification system and development plans for infrastructure. Method: Several certification systems are established and introduction plans are reviewed through experts by synthesizing the contents of certification research for existing infrastructure diagnosis equipment. In addition, the revision of the law for introduction of the system is reviewed, detailed operation regulations are prepared and phased development plans are reviewed, which are based on the operation scenario. Result: Inspection and certification plans were constructed through four routes in order to consider infrastructure inspection and diagnostic equipment in use, and new diagnostic equipment using state-of-the-art technology. Furthermore, market confusion depending on the introduction of a new certification system is minimized and reliability is secured by transforming a simple inspection system in the short term into a formal certification system in the long term. The law amendments according to the introduction of the system were reviewed and detailed operation regulations were developed. Also, phased development plans, which are based on the long-term development scenario including manpower, infrastructure and specifications, were presented. Conclusion: It is important to secure reliability through the distribution and certification of diagnostic equipment using 4th industrial technology to strengthen the safety management of infrastructure at the national level since the infrastructure is various in type and increasingly large in size. It is also essential to train human resources who can use new technology with inspection and diagnosis system in order to enhance the safety management of all infrastructures. Moreover, it is necessary to introduce a regular inspection system for infrastructure that combines loT technology in the long-term point of view and to promote the introduction by giving active incentives to institutions that actively accept it.