• Title/Summary/Keyword: 설정압

Search Result 189, Processing Time 0.027 seconds

Energy Balance Analysis of 30 t Thrust Level Liquid Rocket Engine (추력 30톤급 액체로켓엔진의 에너지 밸런스 해석)

  • Cho, Won-Kook;Park, Soon-Young;Kim, Chul-Woong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.5
    • /
    • pp.563-569
    • /
    • 2012
  • An energy balance analysis is conducted for a 30 t thrust level liquid rocket engine. The relations between thrust and combustion pressure, between thrust and propellant flow rate, and between combustion pressure and fuel pump pressure rise are compared against those indicated by a published database of the existing rocket engines. A combustion pressure higher than the old design value is obtained, implying that the present design is high-performance oriented. The thrust to propellant flow rate ratio is the same as that of the existing engines, indicating that the specific impulse performance is at the usual level. The fuel pump pressure rise is found to be slightly high when the combustion pressure is considered, and it is attributed to the pressure budget of the present ground test engine not being optimized.

Numerical Study on Cavitation Reduction in Velocity-Control Trim of Valve with High Pressure Drop (고차압 밸브의 속도제어형 트림에서 케이테이션 억제에 관한 수치적 연구)

  • Kim, Dae Kwon;Sohn, Chae Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.9
    • /
    • pp.863-871
    • /
    • 2013
  • Flow characteristics of velocity-control trim in a valve is investigated numerically with high pressure drop. A basic trim widely used for a valve in domestic powerplants is selected and designed for a baseline of velocity-control trim. The numerical analysis is focused on flow rate and cavitation with the basic trim. For a condition of high-pressure drop, pressure drop between inlet and outlet and fluid temperature are selected to be 18.1 MPa and $160^{\circ}C$, respectively, which are typical ones considering operating conditions adopted in powerplants. With this baseline model and condition, design changes are made for improvement of flow rate and cavitation phenomenon. For re-design, trim is divided into three zones in radial direction and design parameters of flow area, stage, and flow direction are considered in each zone. With these combined parameters applied to each zone, 4 models with design changes are proposed and their flow rates and cavitation areas are investigated. From comparison with those in the baseline model of a basic trim, proposed models show better performance in both flow rate and cavitation.

A Study on Safety Management Inspection of Diagnostic X-ray System (진단용 엑스선 장치의 안전관리 검사에 관한 연구)

  • Lee, Hoo min;Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.887-893
    • /
    • 2018
  • The purpose of this study is to compare the performance of X-ray generators installed in hospitals and universities and apply the quality control items of diagnostic X-ray generators to recognize the importance of periodic performance management. First, the reproducibility and linearity test results showed that the PAE of the reproducibility evaluation was high for the GX-650 devices that met the acceptance criteria in all the experimental conditions and lacked the periodic quality control. In the linearity evaluation, when the tube voltage was set to 100 kVp, It was measured to deviate from the error. In addition, it was found that the PAE in the low-accuracy evaluation results relative to an X-ray tube voltage and tube current of the device low occurrence frequency. The HVL experiment was included in all of the devices at the HVL by tube voltage. Therefore, it is necessary to recognize the importance of quality control of all devices rather than hospital and laboratory, and to manage the device performance by actively managing the device, and to establish a short - term quality control system like special medical devices.

Influences of Grouting Pressure of Microcement to Upper Structures (지반보강용 마이크로시멘트의 주입압이 상부구조물에 미치는 영향)

  • Hwang, Chul-Sung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.70-77
    • /
    • 2010
  • Microcement grouting and micro pile are frequently used for ground modification during tunnel construction. The influence of grouting pressure of microcement grouting and micro pile to the existing bridge which is directly over the constructing tunnel is investigated. Three dimensional seepage flow-structure interactive analysis considering firm water pressure with full stages of construction including the construction of upper bridge, microcement grouting, micro pile and tunnel is performed. The settlement and tilting of the pier of existing bridge violate the design code and the reaction of the bridge are highly increased after grouting. The stress of tunnel bracings such as rockbolt and shotcrete also exceed the limit of the code. The pressure of microcement grouting is confined by bedrock and transmit to the surrounded soil and the upper bridge. Microcement grouting needs mid-high pressure to penetrate through weak fault plane and the pressure greatly influence the safety of the upper structure. It is important to decide and care the grouting pressure to improve weak fault plane directly under the existing structures and the pressure of microcement grouting should be considered in underground analysis.

Investigation of Tube Voltage Range using Dose Comparison based on Effective Detector Exposure Index in Chest Radiography (흉부 X-ray 검사 시 선량 비교를 활용한 유효 Detector Exposure Index 기반의 적절한 관전압 범위 제안)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.139-145
    • /
    • 2021
  • This study is to confirm the range of tube voltage for Chest X-ray in DR system by comparing with dose area product (DAP) and effective dose in efficient detector exposure index (DEI) range. GE definium 8000 was used to for the phantom study. The range of tube voltage is 60~130 kVp and of mAs is 2.5~40 mAs. The acquired images were classified into efficient DEI groups, then calculated effective dose with DAP by using a PC-Based Monte Carlo Program 2.0. The signal to noise ratio (SNR) was measured at 4 regions, including the thoracic spine, the lung area with the ribs, the lung area without the ribs, and the liver by using Picture Archiving and Communication System. The significance of the group for each tube voltage was verified by performing the kruskal-wallis test and the mann-whitney test as a post-test. When set to 4 groups dependned on the tube voltage, DAP showed significant differences; 60 kVp and 80 kVp, and 60 kVp and 90 kVp (p= 0.034, 0.021). Effective dose exhibited no statistically significant differences from the all of the group (p>0.05). SNR exhibited statistically significant differences from the all of the group in the liver except compared to 80 kVp and 90 kVp (p<0.05). Therefore, high tube voltages of 100 kVp or more need to be reconsidered in terms of patient dose and imaging in order to represent an appropriate chest X-ray image in a digital system.

Swelling behavior Simulation Study of KJ-II Bentonite Buffer Blocks under Various Experimental Conditions (다양한 실험조건에 따른 경주 벤토나이트 완충재 블록의 팽윤 거동 해석)

  • Lee, Deuk-Hwan;Go, Gyu-Hyun;Lee, Gi-Jun;Yoon, Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.2
    • /
    • pp.29-40
    • /
    • 2024
  • This study aimed to evaluate the swelling behavior characteristics of KJ-II buffer blocks by performing numerical analysis of swelling pressure measurement experiments using the nonlinear elasticity model of COMSOL Multiphysics. The analysis was conducted under boundary conditions that included isotropic constraints and water injection pressure, mirroring the experimental settings. Validation of the numerical model was achieved by comparing its outputs with experimental results. The validated model was then used to simulate swelling deformations under unconfined conditions and to analyze swelling pressure as influenced by dry density and the geometric shape of the buffer material. The results accurately represented the swelling deformation observed during the saturation process and demonstrated that swelling pressure increases with higher dry density. Moreover, simulations concerning the geometric shape of the buffer material indicated a markedly faster rate of pressure increase in U-shaped samples compared to cylindrical ones. Analysis suggested that stress manifested preemptively near the internal edges of U-shaped samples during saturation. To enhance the simulation's fidelity to actual buffer material behavior, further refinement of the analysis model using a nonlinear elasticity model is recommended.

노출평가를 위한 TLV 근거 - PHOSPHORUS(YELLOW)

  • Kim, Chi-Nyeon
    • 월간산업보건
    • /
    • s.380
    • /
    • pp.8-15
    • /
    • 2019
  • 황색인(Yellow phosphorus)에 대한 직업적 노출기준 TLV-TWA는 0.1 mg/㎥(0.02ppm)으로 권고하였다. 이 수준은 보고된 간경변증을 포함하여 호흡기 자극, 급성 중독인 전해질 불균형, 심근 붕괴 및 신장 피질 괴사의 가능성을 최소화하기 위한 것이다. 그러나 제한된 자료로 인중독성괴저(phossy jaw)와 같은 만성적 영향에 대한 보호 한계 수준을 설정하기에는 불확실하다. 입자 상태의 인(phosphorus)에 대한 노출은 예상되지만 증기압 수준을 감안할 때 증기에 대한 직업적 노출의 유해성을 내포하고 있다. 황색인은 가장 독성이 강한 무기 물질 중에 하나이다. 또한, 결정체 고체(crystalline solid)는 30℃ 이상의 온도에서 공기 중에 자발적으로 발화될 수 있으며, 독성이 높은 흄도 방출될 수 있다.

  • PDF

Analysis of Battery Charge and Discharge Algorithms for EV/PHEV (PHEV/EV 용 배터리 충방전 알고리즘 비교분석)

  • Jeon, Joon-Young;Choe, Gyu-Yeong;Lee, Byoung-Kuk;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.198-199
    • /
    • 2010
  • 본 논문에서는 전기자동차의 구동에 핵심적인 역할을 하는 이차전지의 충전 방식 중 간단히 구현가능하며 성능이 뛰어난 정전류 정전압 알고리즘과 펄스 충전 알고리즘을 이론적으로 자세히 분석하였으며, 각각의 경우의 충전전류, 충전전압의 특성을 분석하였다. 또한 충전 시퀀스를 정리하였고 배터리 사고방지를 위한 $V_{th}$의 최대 설정치를 분석하였다.

  • PDF

Analysis of dynamic downpull force on the underflow type floating gate with its shape (부력식 수문의 형상에 따른 동적 하향력 분석)

  • Lee, Ji Haeng;Choi, Jong Geun;Choi, Heung Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.42-42
    • /
    • 2019
  • 유량조절을 위한 자동수문은 설정된 관리수위 이하에서는 수문이 개방되지 않으며, 유량이 증가하여 관리수위 이상이 되면 수문이 개방되어 방류를 시작하여 일정 수위를 유지하는 것을 의미한다. 자동수문의 운영 중 수문의 거동과 자동 개폐 시점을 예측하는 것은 정밀한 수문 설계를 위해 매우 중요하다. 수문 하단으로 흐름이 발생하면 수문 선단을 포함한 주변에서의 압력 차이로 인한 동수압 하중이 발생하고 진동을 유발, 수문 개방을 억제하는 하향력 등의 효과로 수문 운영에 큰 영향을 미친다. 본 연구에서는 부력식 수문의 모형실험을 통하여 정수압 상태의 부력 이론에 의한 수문 개방률과 측정에 의한 수문 개방률을 비교하였으며, 이론과 측정 수문 개방고의 차이를 하향력에 의한 효과임을 확인하였다. 부력식 수문의 하향력을 검토하기 위해 기존 이론식을 이용한 결과, 이론식은 부력식 수문에 적용하기 어려운 것으로 나타났다. 따라서, 기존 이론식을 이용하여 부력식 수문의 하향계수 산정을 위한 매개변수 관계식을 개방률을 이용하여 제시하였다. 제시된 매개변수 관계식의 결정계수는 0.721, 수정된 결졍계수는 0.690으로 나타났다. 부력식 수문의 형상비에 따른 하향력을 검토하기 위해서 수치모의를 수행하였다. 모형실험에서 측정된 자료와 수치모형 ANSYS-Fluent의 사용성을 검증하였고, 부력식 수문의 형상비를 0.24, 0.49, 0.69, 0.89, 1.09로 총 5가지로 설정하여 하향계수와 하향력을 분석하였다. 부력식 수문의 하향계수와 하향력 검토는 부력체, 스커트로 구분하여 분석을 수행하였다. 하향계수 분석결과, 하향계수는 개방률이 증가함에 따라 감소하였으며 하향계수가 부력체 부분에서는 0.465~1.542, 스커트 부분에서는 0.058~1.148의 범위로 나타났다. 하향력 분석결과, 하향력은 개방률 0.300 이하에서는 개방률이 증가함에 따라 하향력은 증가하였나 개방율 0.300 초과하면서부터 개방률이 증가함에 따라 하향력이 감소하는 것으로 나타났다. 또한 부력체 부분에서는 형상비가 증가함에 따라 하향력이 감소하였으나, 스커트 부분에서는 형상비가 증가함에 따라 하향력이 증가하였다. 이는 형상비가 증가함에 따라 스커트 부분의 면적이 증가하기 때문이다. 부력식 수문의 전체적인 하향력을 계산한 결과, 부력식 수문의 하향력은 0.002~0.015 kN의 범위를 가지며 형상비가 증가함에 따라 부력식 수문에 발생하는 하향력은 증가하는 것으로 나타났다.

  • PDF

A finite element analysis of implant-supported overdenture on the effect of anterior cantilever (임플랜트 bar overdenture에서 bar의 cantilever양이 임플랜트에 미치는 영향에 관한 삼차원 유한요소분석적 연구)

  • Jung, Tae-Wook;Kim, Young-Soo;Kim, Chang-Whe;Ling, Booi-Cie
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.1-17
    • /
    • 1998
  • 두개의 임플랜트로 지지되는 overdenture를 이용한 하악무치악환자의 치료법은 경제적이면서, 실용적인 치료로 인정을 받고 있다. 하지만 해부학적인 조건으로 임플랜트를 설측 혹은 후방에 식립해야 되는 경우에는 일반적인 bar설계는 bar가 구강저 상방을 지나게 되어 혀운동, 발음, 위생관리 등에 많은 문제점을 부여한다. 이에 대한 해결방법으로 전방부 치조제 상에 보철물의 회전을 허용하는 angular bar를 설계할 수 있다. 하지만 이 설계는 임플랜트에 불리한 moment를 유발한다. 그럼에도 불구하고 뛰어난 유지력과 지지능력, 경제적인 면 때문에 angular bar는 임상에서 많이 사용되고 있다. 이에 본 연구는 angular bar의 전방 cantilever양을 달리하여 임플랜트 및 주변조직에 미치는 영향을 삼차원 유한요소분석법을 통해서 알아보고자 하였다. 이공사이의 하악골을 단순화시킨 준하악골모형에 직경 3.75mm인 브로네마르크 임플랜트 2개를 길이가 13,15mm인 경우로 설정하여 제 1소구치 부위에 식립하였다. 두 임플랜트를 연결하는 bar는 전방부 cantilever양을 0-5mm, 1mm씩 하여 6가지 경우를 가정하고 제작하였다. 각각 bar 중앙부에 수직압 (90도) 35N, 경사압(120도) 70N, 수평압(0도) 10N을 가하였으며 이때 나타나는 응력 분산형태와 임플랜트의 골유착에 불리하게 작용하는 최대주응력(인장력)과 변위량을 살펴보았다. 연구결과 다음과 같은 결론을 얻었다. 1. Cantilever양이 증가할수록 주변피질골과 임플랜트로 응력이 집중되었으며 상부 보철물의 변위량도 커졌다. 2. Cantilever양에 대한 수평압의 영향은 크지 않았으며 임플랜트 길이가 긴 것이 변위량과 응력이 작았다. 3. 경사압에 대한 응력의 변화는 cantilever양의 증가에 따라 급격히 증가하는 양상을 띠었으며 임플랜트길이가 응력 및 변위의 양에 미치는 영향은 없었다. 4. 수직압에 대한 응력의 변화는 초기에는 완만한 증가를 보이다가 일정 시점 지난 후에는 증가율이 커지는 경향을 띠었다. 증가현상이 두드러지기 전에는 길이의 증가가 응력의 분산효과는 가져왔으나 이후에는 길이의 응력분산 효과는 없었다. 5. 응력분포양상은 cantilever양이 증가할수록 골조직을 통한 분산정도는 작아지고 특정부위의 피질골과 임플랜트, 상부보철물에 집중되는 경향을 보였다. 6. 임플랜트와 주변 골조직으로의 응력분산능력이 예후를 좌우한다는 점에서 angular bar는 적합치 못하며 부득이한 경우는 임플랜트 길이를 길게 하고 최대한 3mm이내로 cantilever양을 제한하는 것이 추천된다.

  • PDF