• Title/Summary/Keyword: 설비개수

Search Result 82, Processing Time 0.028 seconds

Experimental Research of Window Air Tightness and Opening Force with Respect to Mohair Number, Clearance and Shortened Length (모헤어 개수, 틈새 길이 및 축소된 길이의 창문 기밀성 및 개폐력에 대한 실험적 연구)

  • Kim, Seung Jae;Park, Jong Jun;Kim, Young Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.4
    • /
    • pp.195-203
    • /
    • 2018
  • Mohair is widely used as an airtight material for filling the gap between a window frame and sash. The purpose of this study is to investigate infiltration rate and opening force of sliding windows according to the mohair installation conditions. Infiltration experimental apparatus was set up, and the experimental results were applied to windows to find a correlation between infiltration rates and opening forces. When 4 rows of mohair were installed, the infiltration rate increase became 27.1% per clearance length increase of 1 mm, and the infiltration rate decrease became 5.7% per shortened length increase of 0.1 mm. For 4 rows of mohair, the opening force decreased by 28.2% as the clearance increased by 1 mm, and it increased by 9.3% as the shortened length increased by 0.1 mm.

A High Effeciency Functional Water Generation Characteristics by Corona Discharge and Space Charge Control (코로나방전과 공간전하제어에 의한 고효율 기능수 발생특성)

  • 김진규
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.101-107
    • /
    • 2002
  • A novel oxidant generation and ion precipitation cell with slits on parallel plate electrodes was proposed instead of the conventional parallel plate type. An investigation was carried out on the effect of the number and size of slits on ion precipitation and oxidant generation characteristics, evidenced by eliminated space charge limiting action and by elevated electric fields in active interelectrode sparing. Consequently, very high ion precipitation and dense oxidant generation characteristics can be realized by having slits un the electrodes of conventional cells as these slits increase the electric fields and decrease the space charge limiting actions in interelectrode spacing.

Luminous Environment and Light Pollution in Gas Stations with Non-cutoff Luminaires (Non-cutoff 조명기구가 설치된 주유소의 조명환경 및 빛공해 평가)

  • Kong, Hyo-Joo;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.7-16
    • /
    • 2008
  • Lighting for gas station should be carefully designed with safety and visually attraction. Recent studies have shown that non-cutoff luminaires should not be used for gas station. duo to light pollution and energy waste. This paper aims to evaluate the luminous environment in gas station with non-cutoff luminaires. The CS-100 and Radiant Imaging Prometric-1400 were used to measure the luminance of building surface, canopy, ceiling and ground surface. The result shows that the whole luminance of various combination elements in gas station increases by rising the total luminaires of the canopy. All of the gas stations with non-cutoff luminaries produce light pollution. Some guidelines for outdoor lighting in gas station is necessary.

Effects of Thermoelectric Module Arrangement on the Performance of a Thermoelectric Air-Cooling System (열전모듈 냉방기에서 열전모듈의 개수 및 전원배열이 시스템의 성능에 미치는 영향)

  • Hwang, Jun;Kang, Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.2
    • /
    • pp.162-168
    • /
    • 2007
  • This paper presents the effects of thermoelectric module arrangement on the cooling performance of an air conditioner using thermoelectric module. A prototype of air cooling system, employing several thermoelectric modules, has been designed and built. The evaporative cooling technique is adopted for hot side of the module. The number of thermoelectric module in the system has been varied in the range of $2{\sim}8$. The optimal operation conditions, such as input power to the thermoelectric module, fans and pump, have been determined for each arrangement of the system and the cooling performance has been compared under the optimal operation. It is found that both cooling capacity and COP are increased as the number of thermoelectric module increased. It is also found that cooling capacity can be improved by connecting the thermoelectric modules in series than in parallel, while the COP is little affected.

Separation of Partial Discharge Signals and Noise (부분방전 신호와 잡음의 분리)

  • 이승환;유치형;정찬수;김재철;이상철;정양웅
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.21-30
    • /
    • 1999
  • The research for retecting of insulating deterioration in transforrrer has been studied from long ago and the analysis rrethod of combustible gas which is included in insulating oil has been used Recently the spreading effect of the accident is larger than before because of high voltage and large capacity, so on-line detecting system is needed and the study for the estimation of partial discharge signals location has begun. This thesis is the study for the sermating noise signal that is the greatest problem in ultrasonic signal measurement which is one of the method of estimation of partial discharge signals location. Because we can measure the number and location of signal, it is rossible to distinguish between the signal of partial discharge and the external noise. Therefore, we can devolop the credibility of detecting of insulating deterioration in transformer.former.

  • PDF

Autoencoder-based MCT Anomaly Detection Algorithm (오토인코더를 활용한 MCT 이상탐지 알고리즘 개발)

  • Kim, Min-hee;Jin, Kyo-hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.89-92
    • /
    • 2021
  • In a manufacturing fields, an abnormality or breakdown of equipment is a factor that causes product defects. Recently, with the spread of smart factory services, a lot of research to predict and prevent machine's failures is actively ongoing. However, there is a big difficulty in developing a classification model because the number of abnormal or failure data of the machine is severely smaller than normal data. In this paper, we present an algorithm for detecting abnormalities in an MCT at manufacturing work site depending on the differences between inputs and outputs of Autoencoder model and analyze its performance. The algorithm detects abnormalities using only features of normal data from manufacturing data of the MCT in which abnormal data does not exist.

  • PDF

Development of Ozone Generation Technology Using Gaseous Electrical Discharge for Environment Improvement (환경개선용 기체전기방전을 이용한 오존발생기술 개발)

  • 이동헌;송현직;구건효
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.25-34
    • /
    • 2001
  • In this paper, discharge lamp ozonizer(DLO) of a new discharge type using superposition of gaseous electrical discharge for environment improvement was designed and manufactured. DLO is equipped with 3 electrodes(central ground electrode of discharge lamp type internal high voltage electrode of mesh type and external high voltage electrode of spiral type), and it is composed of double gap(gap between discharge lamp and internal electrode, gap between discharge lamp and external electrode). Internal and external electrodes are respectively applied AC high voltage which has 180[$^{\circ}$] phase difference. Ozone is generated by overlaying of each silent discharge which is respectively came from two gaps. At the moment discharge characteristics and ozone generation characteristics of DLO were investigated in accordance with quantity of supplied gas, discharge power and the number of DLO. When ozone generated by DLO was in contact with NO gas, removal characteristics was excellent, so it confirmed that DLO could be used as air environment improvement facility.

  • PDF

A Study on the Improvement of Technical Regulations in the Customer Cabling Systems for FTTH (FTTH를 위한 구내선로설비 기술기준개선 연구)

  • Choi, Mun-Hwan;Kang, Young-Heung;Cho, Pyoung-Dong;Yang, Jun-Kyu;Lee, Sang-Mu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.9
    • /
    • pp.1729-1733
    • /
    • 2007
  • In this paper, we have carried out some tests for analyzing the effects of optical fiber characteristics and piping structures in designing a Customer Cabling System with optical fibers. In this tests, the loss characteristics due to the number of curvatures and the radius of curvature with bending to establish an optical fiber have analyzed particularly. We can confirm that the test results satisfy the current technical regulations in both cases of the number of curvatures and the radius of curvatures. Also, in particular, since there is no loss in an optical cable under the current radius of curvature, that is 30mm, the radius criteria of curvature needs to be revised. These tests results will be so useful to revise and establish a customer cabling system for FTTH.

Discharge Coefficient of Triangular Side Weir (삼각형 횡월류위어의 유량계수)

  • Park Sung Sik;Seo Geun Soon;Kim Young Ho;Song Jai Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1016-1020
    • /
    • 2005
  • 횡월류위어(side weir 또는 lateral weir)는 인공수로 또는 자연하천에서 흐름방향에 평행하게 수로측면에 설치되어 에너지 소산, 수위의 안정, 일정 유량의 취수 및 분배, 초과 홍수량 전환 등의 목적으로 이용되는 수공구조물로서 댐의 여수로, off-line 저류지, 관개배수를 위한 수로. 하수도 설비 등에서 폭넓게 사용되고 있다. 지금까지의 국내외 연구는 대부분 직사각형 횡월류위어에 제한되어 수행되었으며, 삼각형 횡월류위어의 흐름특성 및 유량계수 산정에 관한 연구는 거의 없는 실정이다. 본 연구에서는 수리실험을 통하여 본류의 흐름조건과 삼각형 횡월류위어각 등을 변화시켜 유량계수를 산정$\cdot$분석하였다. 수리실험은 길이 20m, 폭 0.8m, 높이 0.9m이고 벽면이 아크릴로 된 직사각형 가변 경사 개수로 실험장치를 이용하였다. 삼각형 횡월류위어는 예연이고 위어각은 90, 120, $150^{\circ}$였으며, 본류 Froude 수는 0.45-0.56였다. 삼각형 횡월류위어의 월류량에 큰 영향을 미치는 변수인 Froude 수와 위어각 등을 고려한 유량계수 산정식을 제시하였으며, Kumar와 Pathak(1987)의 공식과 비교 분석하였다.

  • PDF

Characteristics of Discharge Lamp Type Ozonizer for NO Gas Removal (NO 가스 제거용 방전관형 오존발생기의 특성)

  • Song, Hyun-Jig;Lee, Dong-Heong;Oh, Jin-Hun;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1762-1764
    • /
    • 2001
  • 대기환경오염물질인 NO가스의 제거를 위하여 방전관을 채용한 3전극-2갭 방식의 새로운 형태의 오존발생기를 설계 제작하였다. 본 논문에서는 원료가스의 유량, 방전전력 및 오존발생기의 사용 개수 변화에 따른 방전특성과 오존생성특성을 연구검토하였으며, 오존발생기로부터 생성된 오존을 NO가스에 접촉시켰을 때 NO 제거특성이 우수하여 방전관형 오존발생기가 대기환경개선 설비로 적용가능함을 확인하였다.

  • PDF