• Title/Summary/Keyword: 설계 특성

Search Result 20,153, Processing Time 0.05 seconds

An exploratory study on practice-oriented reconceptualization of self-sufficiency : Service providers' reflections on their own experiences from the field (현장의 시각으로부터 구조화된 자활 개념 탐색 연구 : 자활사업 실무자의 이해를 중심으로)

  • Choi, Sangmi;Hong, Song-Iee
    • Korean Journal of Social Welfare Studies
    • /
    • v.49 no.3
    • /
    • pp.5-33
    • /
    • 2018
  • A self-sufficiency service has worked as a typical workfare policy combined with public assistance in Korea since 2000. Despite of its long history, three core pillars in administrating the self-sufficiency service, policy, research, and practice, have respectively understood the meaning of self-sufficiency in terms of their own interests. As a result, the self-sufficiency service has recently faced with its own identity issues by showing failures to its environmental changes. The current situation makes it necessary to reconceptualize the definition of self-sufficiency by exploring its in-depth understanding perceived by service providers. Specifically, we analyzed practical reflections on 35 service providers' experiences which were collected via focus group interviews for two hours. The study findings presented that service providers had two antithetical approaches towards self-sufficiency. While a dominant approach to self-sufficiency has been concentrated on improving clients' economic outcomes such as employment, job retention, the escape from welfare trap, and increasing earnings and assets, the other approach has been extended to empower clients and achieve their well-being and quality of life. Yet, these contrary perspectives have led to suffer from their role confusions and identity crisis between the work-ready process and the employment-oriented outcomes. Specifically, they described self-sufficiency in terms of psychological, social, and integrated aspects. The psychological aspect included a process of developing inner strengths, intensifying job motivation, and coping with barriers of employment. The social aspect meant a path toward social integration through recovering human relationships. The integrated aspect covered more comprehensive support for their recovery of daily life and autonomy to make a decision for their own life. In conclusion, the study findings suggest that self-sufficiency should be more extensively considered as a stepwise process towards work-ready preparations beyond ultimate economic outcomes. Such an extended concept of self-sufficiency could contribute to restructuring the whole practice of self-sufficiency including organizational and program changes in the fields.

A study on drainage characteristics and load amount evaluation by crop type in a hydroponic cultivation facility of horticultural complex (수경재배 시설원예단지 작물 유형별 배액 특성 및 부하량 평가 연구)

  • Jin, Yujeong;Kang, Taegyoung;Lim, Ryugab;Kim, Hyunwoo;Kang, Donghyeon;Park, Minjung;Son, Jinkwan
    • Journal of Wetlands Research
    • /
    • v.23 no.4
    • /
    • pp.352-363
    • /
    • 2021
  • The purpose of this study was to evaluate the load of nutrients contained in the drainage discharged from the facility horticultural complex and to use them for re-use of fluids and design for introduction of water treatment plants. Representative hydroponic cultivation crops were selected as tomato, paprika, cucumber, and strawberry, and the total number of samples analyzed for water quality was 80. As a result of the analysis, since various fertilizer components such as N, P, K+, Na+, Mg2+, Ca2+, Si4+, HCO3-, Cl-, S2-, Fe, Mn, Cu, Zn, Mo and B are contained at very high concentrations in the drainage, the need for water treatment was confirmed. Through statistical analysis, it was analyzed that the drainage concentration of strawberries was lower than that of tomatoes, paprika, and cucumbers. In the case of tomatoes, these essential ion concentrations are the highest, so it was confirmed that they are subject to valuable resources in terms of reuse of fertilizers. The load of N and P of the drainage discharged from the facility horticultural complex 1m2 was analyzed. For N, the daily processing capacity of 4.0 kg of tomatoes, 3.3 kg of paprika, 3.0 kg of cucumbers, and 1.5 kg of strawberries was calculated based on 1 ha. It was suggested that the P concentration needs a scale and capacity that can handle 0.5 kg of tomatoes, 0.6 kg of paprika, 0.4 kg of cucumber, and 0.2 kg of strawberries per day. Through this study, the amount of nitrogen and phosphorus contained in the drainage discharged from the greenhouse of each crop was evaluated to analyze the economy. In addition, it was expected to be used as basic data that can be used to calculate the treatment capacity to be reflected when introducing water treatment facilities in facility horticultural complexes for sustainable agriculture.

Estimation of Allowable Bearing Capacity and Settlement of Deep Cement Mixing Method for Reinforcing the Greenhouse Foundation on Reclaimed Land (간척지 온실기초 보강을 위한 심층혼합처리공법의 허용지내력 및 침하량 산정)

  • Lee, Haksung;Kang, Bang Hun;Lee, Kwang-seung;Lee, Su Hwan
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.287-294
    • /
    • 2021
  • In order to expand facility agriculture and reduce greenhouse construction costs in reclaimed land, a greenhouse foundation method that satisfies economic feasibility and structural safety at the same time is required. As an alternative, the allowable bearing capacity and settlement were reviewed when the DCM(Deep cement mixing) method was applied among the soft ground reinforcement methods. To examine the applicability of the greenhouse foundation, the allowable bearing capacity and settlement were calculated by applying the theory of Terzaghi, Meyerhof, Hansen, and Schmertmann. In case of the diameter of 800mm and the width and length of the foundation of 4m, the allowable bearing capacity was 179kN/m2 and the settlement was 7.25mm, which satisfies the required bearing capacity and settlement standards. The calculation results were verified through FEM(Finite element method) analysis using the Mohr-Coulomb material model. The allowable bearing capacity was 169kN/m2 and the settlement was 2.52mm. The bearing capacity showed an error of 5.6% compared to calculated value, and the settlement showed and error of 65.4%. Through theoretical calculations and FEM analysis, it was confirmed that the allowable bearing capacity and settlement satisfies the design criteria as a greenhouse foundation when the width and length of the foundation were 4m. Based on the verified design values, it is expected to be able to present the foundation design criteria for greenhouses through empirical tests such as bearing capacity tests and long-term settlement monitoring.

A Study on the Effect of Applying Water Seepage Lowering Method Using Swelling Waterstop for Expansion Joint in the Concrete Dam (콘크리트 댐에서 수축이음부의 수팽창성 차수재를 이용한 침투저감 공법 적용효과 연구)

  • Han, Kiseung;Lee, Seungho;Kim, Sanghoon;Kim, Sejin;Pai, Sungjin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.10
    • /
    • pp.21-29
    • /
    • 2021
  • Most concrete gravity-type dams in and out of the country were constructed by column method to control cracks caused by concrete hydration heat generated during construction, resulting in a certain level of leakage after impoundment through various causes, such as contraction joints and construction joints. However, due to the characteristics of concrete structures that shrink and expand according to temperature, concrete dams have vertical joints and drains to allow penetration. PVC waterproof shows excellent effects in completion of the dam, which however increases the possibility of interfacial failure due to different thermal expansion. Other causes of penetration may include problems with quality control during installation, generation of cracks due to heat of hydration of concrete, waterproofing methods, etc. In the case of Bohyunsan Dam in Yeongcheon, North Gyeongsang Province, the amount of drainage in the gallery was checked and underwater, and it was confirmed that there are many penetrations from drainage holes connected to vertical joints, and that some of the PVC waterproofs are not fully operated. As a new method to prevent penetration through vertical joints, D.S.I.M. (Dam Sealing Innovation Method) developed by World E&C was applied to Bohyunsan Dam and checked the amount of drainage in the gallery. As a result of first testing three most leaking vertical joints, the drain in the gallery was reduced by 87% on the average and then applied to the remaining 13 locations, which showed a 83% reduction effect based on the total drain in the gallery. Summing up these results, it was found that D.S.I.M. preventing water leakage from the upstream face is a valid construction method to reduce the water see-through and penetration quantity seen in downstream faces of concrete dams. If D.S.I.M. is applied to other concrete dams at domestic and abroad, it is expected that it will be very effective to prevent water leakage through vertical joints that are visible from downstream faces.

NOx Emission Characteristics with Operating Conditions of SNCR in SRF Usage Facilities (고형연료제품 사용시설에서의 SNCR의 운전조건에 따른 NOx 배출특성)

  • Seo, Je-Woo;Kim, Younghee
    • Clean Technology
    • /
    • v.27 no.4
    • /
    • pp.350-358
    • /
    • 2021
  • The results of this study shows that the combustor temperature ranged from 848.27 to 1,026.80 ℃, averaging about 976.61 ℃, and the NOx concentration increased as the temperature increased. The urea usage ranged from 291.00 to 693.00 kg d-1, averaging about 542.34 kg d-1, and the NOx concentration decreased as the urea usage increased. Residence time was about 3.38 to 9.17 s, averaging about 5.22 s, about 2.61 times larger than the 2 s of the design details. This is 1,086 kg h-1, averaging about 55.71%, compared to the 1,950 kg h-1 SRF input permission standard. The combustion chamber area is constant, but the residence time is shown to increase with the decrease of exhaust gas. The O2/CO ratio was 847.05 to 14,877.34, averaging about 3,111.30, and the NOx concentration slightly increased as the O2/CO ratio increased. As the combustor temperature and O2/CO ratio increased, the combustion reaction with nitrogen in the air increased and the NOx concentration slightly increased. As the urea usage and residence time increased, the NOx concentration decreased slightly with an increase in reactivity with NOx. The NOx concentration at the stack ranged from 7.88 to 34.02 ppm with an average of 19.92 ppm, and was discharged within the 60 ppm emission limit value. The NOhx emission factor was 1.058 to 1.795 kg ton-1, averaging about 1.450 kg ton-1. This value was about 24.87% of the maximum emission factor of 5.830 kg ton-1 of other solid fuels. Other synthetic resins and industrial wastes were 79.80% and 43.65% compared to 1.817 kg ton-1 and 3.322 kg ton-1, respectively. This value was similar to 1.400 kg ton-1 of RDF in the NIER notice (2005-9), 10.98% compared to the maximum SRF of 13.210 kg ton-1. Therefore, the NOx emission factor had a large deviation.

A Study on the Hipped-and-Gable-Roof Framework of Muryangsujeon of Buseoksa Temple (부석사 무량수전 측면 지붕부 결구의 구성방식에 관한 재고(再考) - 중국 원대(元代) 이전 목조건축과의 비교를 중심으로 -)

  • Cha, Ju-hwan
    • Korean Journal of Heritage: History & Science
    • /
    • v.49 no.3
    • /
    • pp.78-103
    • /
    • 2016
  • This research is a study on the side framework structure of the hipped and gable roof of Muryangsujeon at Buseoksa Temple. There is a record that Muryangsujeon was deconstructed and repaired in the period of Japanese Occupancy, and its authenticity has continuously been called into question because the structure of the hipped and gable side roofs, and the bonding of the rafters and eaves were not in good order and very different from those of Joseon Dynasty. Scholars date it differently. It is either dated at 13th century or 12th century. This study compares the non-planar configuration of the middle and front proportions of Muryangsujeon's hipped-and-gable-roof framework with those of the Tang(唐) and Song(宋) Dynasties in China. It concludes that the hipped-and-gable-roof framework of those architecture were built with the same technique. The style of architecture that side rafters directly touch the internal security (梁), like in Muryangsujeon, is not usual even among the hipped and garble roofs of the Tang(唐) and Song(宋) Dynasties. The technique of constructing the hipped roofs developed much further after the Tang Dynasty because they began to use garble eaves to build the side structure. The technique seems to have developed greatly by the period of Ming and Qing Dynasties. It also seems that the parallel-flat (平行輻射椽) rafter, which is the form of rafters used between the parallelrafter period and the half-flat-rafter period is very similar to the construction style of the current rafters of Muryangsujeon. However, the Muryangsujeon's eaves do not touch the corner rafter from the middle part. This seems to be a unique style, which is not common in China. In conclusion, the style of the side roof framework of Muryangsujeon at Buseoksa Temple is not of the China's southern regions, but of the northern regions of Tang(唐), Song(宋) and Liao(遼) Dynasties. And when considering the construction year and proportions of the middle front and side front on the same flat, this must be an ancient technique of the northeastern regions of Asia. Since it is likely that the structure of the side roof framework of Muryangsujeon at Buseoksa Temple has not been altered but is a unique style of hipped and gable roofs, this roof can serve as a good guide to restoring the hipped and garble roofs of the pre-Goyreo Dynasty period.

An essay on appraisal method over official administration records ill-balanced. -For development of appraisal process and method over chosun government-general office records- (불균형 잔존 행정기록의 평가방법 시론 - 조선총독부 공문서의 평가절차론 수립을 위하여 -)

  • Kim, Ik-Han
    • The Korean Journal of Archival Studies
    • /
    • no.13
    • /
    • pp.179-203
    • /
    • 2006
  • This study develops the process and method of official administration documents which have remained ill-balanced like the official documents of the government-general of Chosun(the pro-Japanese colonial government (1910-1945)). At first, the existing Appraisal-theories are recomposed. The Appraisal-Theories of Schellenberg is focused valuation about value of records itself, but fuction-Appraisal theory is attached importance to operational activities which take the record into action. But given that the record is a re-presentation of operational activities, the both are the same on the philosophy aspect. Therefore, in the case that the process - method is properly designed, it can be possible to use a composite type between operational activities and records. Also, a method of the Curve has its strong points in the macro and balanced aspect while the Absolute has it's strength in the micro aspect, so that chances are that both alternate methodologies are applied to the study. Hereby, the existing Appraisal theories are concluded to be the mutually-complemented things that can be easily put together into various forms according to the characteristics of an object and its situation, in the terms of the specific Appraisal methodology. Especially, in the case of this article dealing with the imbalance remains official-documents, it is necessary to compromise more properly process with a indicated useful method than establishing a method and process by choosing the only one theory. In order to appraise the official-documents of the pro-Japanese colonial government (1910-1945), a macro appraisal of value has to be appraised about them by understanding a system, functions and using the historical-cultural evolution, after analysing Disposal Authority. From this, map the record so that organization function maps are constructed regarding the value rank of functions and detailed-functions. After this, establish the appraisal strategy considering the internal environment of archival agencies and based on micro appraisal to a great quantity of records remained and supplying other meaning to a small quantity of records remained for example, the oral resources production are accomplished. The study has not yet reached the following aspects ; a function analysis, historical decoding techniques, a curve valuation of the record, the official gazette of the government general of Chosun( the pro-Japanese government for 1910-1945), an analysis method of the other historical materials and it's process, presentation of appraisal output image. As the result, that's just simply a proposal and we should fill in the above-mentioned shortages of the study through development of all the up-coming studies.

Study on Korean SMEs' Brand Luxuriousness Building (마케팅 믹스를 활용한 한국 중소기업의 브랜드 명품성 구축에 대한 연구)

  • Koh, InKo
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.13 no.6
    • /
    • pp.1-14
    • /
    • 2018
  • As interest and consumption of luxury goods have become more popular, luxury goods market is growing rapidly. Consumers can acquire psychological satisfaction with material abundance by purchasing and using luxury goods. Also, from the view of corporations, luxury goods have price inelastic characteristics, so they can enjoy price premium and it is good to produce good performance. That is the reason why they should pay much attention to securing luxuriousness. This study examined the establishment of brands luxuriousness in Korean SMEs. First, it examined the world market of luxury goods industry and the present condition of Korean market. Then it identified the constituents of luxuriousness by examining the prior studies and related literatures, and designed a research model based on the theoretical grounds to suggest the methods of brand luxuriousness building of Korean SMEs. Luxuriousness can be defined as the attribute of product that distinguishes luxury goods from other products by consumers' perceptions, and the factor that provides situational benefits that motivate consumers' purchasing behavior. In this study, I identified the sub-dimensions of luxuriousness according to whether there are product related attributes and consumers' benefit in consideration of the problems of existing studies. Product related luxuriousness are classified into superiority(functional benefit) and scarcity(experiential benefit), while non-product related luxuriousness are classified into differentiation(symbolic benefit) and traditionality(exclusive benefit). The following are the ways to build brand luxuriousness. First, company can use product factors. High quality, excellent design, high recognized brand with strong, favorable and unique images can enhance the luxuriousness of brand. Second, company can use price factors. Consumers tend to perceive luxury goods as high-priced items, so lowering the price of product can undermine the luxuriousness of product. Third, company can use distribution factors. It is effective for making consumers to perceive the differentiation and scarcity of luxuriousness through limited distribution channel. In addition, store atmosphere suitable for luxury brands should be created. Fourth, company can use promotion factors. The more consumers are exposed to advertisements, the more positive attitudes toward luxury brands are made, and consumers recognize luxuriousness higher. Price promotion negatively affects consumers' perception of luxuriousness. Fifth, company can use corporate factors. Consumer evaluations of products are influenced not only by the product attributes but also by the corporate association and corporate image surrounding the product. Considering the existing researches, it is possible to enhance the brand luxuriousness through high corporate competence and good corporate reputation. In order to increase the competence of the enterprise, it is useful to approach multidimensionally in relation with the knowledge creation capability. In corporate reputation, the external stakeholders' reputation is important, but the internal members' reputation is also important. Korean SMEs will be able to build brand luxuriousness by establishing marketing strategies as above and/or mix(integrate) them according to the situation.

Evaluation of Composting Characteristics According to the Air Supply Change in Farm-Sized Swine Manure (농가규모 양돈분뇨 퇴비화시 공기공급량 변화에 따른 퇴비 특성 평가)

  • Lee, Sunghyoun;Jeong, Gwanghwa;Lee, Dongjun;Lee, Donghyeon;Jang, Yuna;Kwag, Junghoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.3
    • /
    • pp.49-61
    • /
    • 2019
  • Swine manure has been recognized as a organic sources for composting and many research was conducted to efficiently utilize and treat. This study was to evaluate a feasibility for producing swine manure compost under various treatment with mixture of swine manure and saw dust. Treatments were designed as follows; non aerated composting pile(REF), aerated composting pile of $100L/m^3$(EXP1), and aerated composting pile of $150L/m^3$(EXP2). The total days of fermentation were 28 days and each samples were collected at every 7 days from starting of composting. Temperature sensors were installed under 30~40cm from the surface of composting pile. Inner temperature in composting piles of EXP1 and EXP2 was rapidly increased to $67{\sim}75^{\circ}C$ within 1~2 days. The elevated temperatures found during the thermophilic phase are essential for rapid degradation of organic materials. While swine manure composted, moisture content, total nitrogen, EC of EXP1, EXP2 in sample at 28 days were lower than those of REF. But, pH and organic matter of EXP1, EXP2 in sample at 28 days were higher than those of REF. After finishing fermentation experiment, maturity was evaluated with germination test. Calculated germination index(GI) at REF, EXP1 and EXP2 were 23.49, 68.50 and 51.81, respectively. The values of germination index were higher at EXP1 and EXP2 which is aerated composting piles than REF which is non aerated composting pile. According to the results, composting process by aerated static pile compost had significant effect on the reduction of required period for composting. Supplying adequate amount of air to compost swine manure will greatly reduce composting period.

A study on the fire characteristics according to the installation type of large smoke exhaust port in a small cross sectional tunnel fire (소단면 대심도 터널 화재시 대배기구의 설치형태에 따른 화재특성 연구)

  • Choi, Pan-Gyu;Baek, Doo-San;Yoo, Ji-Oh;Kim, Chang-Yong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.201-210
    • /
    • 2019
  • Recently, due to the efforts to mitigate traffic congestion and expansion of space efficiency, the construction of underground roads has been increased in big-scale cities. Since tunnels in the city have a higher chance for a fire leading to a great tragedy during a severe traffic jam than mountain tunnels, it is highly likely that it will be constructed as a tunnel, having a small cross section, for small vehicles. However, if they are constructed as such small-vehicle tunnels, it would be possible to reduce the design fire intensity while the concentration of harmful gases would increase due to a reduction in the small cross sectional area, led by a decrease in the tunnel height. In this study, behaviors of fire smoke by the installation interval and format of large-scale exhaust-gas ports were examined and compared in the analysis of temperatures and CO concentrations of a tunnel and its results were as the following. Although there were no significant differences in the smoke spreading distance between installation intervals, but in this study, 100 m was found to be the most effective installation interval. The smoke exhaustion performance was found to be excellent in the order of $4m{\times}3m$, $6m{\times}2m$, and $3m{\times}2m$ (2 lane) of the smoke spreading distance. Although there was no significant difference in the smoke spreading distance between formats of large-scale exhaust-gas ports, it was found that the smoke spreading distance was larger than other cases when it was $3m{\times}2m$ in the fire growing process. The analysis of smoke spreading distances by the aspect ratio showed that a smoke spreading distance was shorted when its the smoke spreading distance was found to be shorter when its traverse distance was relatively longer than its longitudinal distance.