• Title/Summary/Keyword: 선형 곡률

Search Result 144, Processing Time 0.027 seconds

Spacing of Intermediate Diaphragms Horizontally Curved Steel Box Girder Bridges considering Bending-distortional Warping Normal Stress Ratio (곡선 강박스 거더의 휨-뒤틀림 응력비에 따른 중간 다이아프램 간격)

  • Lee, Jeong-Hwa;Lee, Kee-Sei;Lim, Jeong-Hyun;Choi, Jun-Ho;Kang, Young-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6325-6332
    • /
    • 2015
  • Although distortions of horizontally curved box girder are more susceptible than which of the straight girder due to curvature effect, current domestic design standards does not present spacing of intermediate diaphragms for the curved box girder. In this study, parametric studies for straight and curved box girder considering distortional warping normal stresses based on linear finite element analysis were carried out. Single span curved girders were chosen for analysis based on current domestic bridge data with 1-6 of solid intermediate diaphragms, 0-30 degree of subtended angle, 30m and 60m of span length and 2-3m of flange width and web height. The adequate spacing of diaphragms for the box girder were suggested considering subtended angles and bending and distortional warping normal stress ratios with 5%, 10%, 15% and 20%. The analysis results were also compared to a current design standard and suggested spacing of diaphragm were evaluated.

Control Effectiveness of Shear Walls Connected by Beams with Friction Dampers (인방보에 마찰형 감쇠기가 설치된 전단벽의 제진효과)

  • Chung, Hee-San;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.1
    • /
    • pp.105-115
    • /
    • 2009
  • Numerical analysis of shear walls governed by flexural behavior is conducted for the seismic control performance of proposed friction dampers installed at the center of coupling beams. Control effectiveness of shear walls connected by beams with the proposed dampers are compared for single shear wall with same flexural rigidity. Average responses of the shear walls with the dampers are found with seven scaled-downed earthquakes based on KEC 2005 design spectrum. Slip load is the most important design parameter. It is designed to be 5, 10, 20, 30, 60, 90% of total vertical shear force at damper location to prevent damper slip in specific stories. Nonlinear time-history analysis is conducted by using SeismoStruct analysis program. Seismic control performance of the dampers is evaluated for base shear, energy dissipation, curvature and top-floor displacement. Results show that the dampers are the most effective in reducing the responses when their total slip load is 30% of total vertical shear force.

Ultimate Strength Interaction of Steel/Concrete Composite Trapezoidal Box Girders Subjected to Concurrent Action of Bending and Torsion (휨과 비틀림을 동시에 받는 강/콘크리트 합성 제형 박스거더의 극한강도 상호작용)

  • Kim, Kyung-Sik
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.5
    • /
    • pp.465-475
    • /
    • 2010
  • In the horizontally curved bridges, girders are subjected to the combined action of vertical bending and torsion due to their curvatures without any eccentric loads. As subjected to bending and torsion, the ultimate strength of steel/concrete composite box girders are limited by the diagonal tensile stress in the deck concrete induced by the St. Venant torsion. To determine the ultimate strength of composite box girders in bending and torsion and their interactions, this study conducted a 3-dimensional FEA and classical strength of materials investigation. Using ABAQUS, the FEA fully utilized advanced nonlinear analysis techniques simulating material/geometrical nonlinearity and post-cracking behaviors. The ultimate strength from numerical data were compared with theoretically derived values. Concurrent compressive stresses in the concrete deck improve the shear-resisting capacity of concrete, thereby resulting in an increased torsional resistance of the composite box girder in positive bending. The proposed interaction equation is very simple yet it provides a rational lower bound in determining the ultimate strength of concrete/steel composite box girders.

The Prediction of Temperature in Composite Box Girder Bridges (합성 박스형 교량의 온도 예측)

  • Chang, Sung Pil;Im, Chang Kyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.431-440
    • /
    • 1997
  • The paper describes a theoretical model for the prediction of bridge temperatures from meteorological data measured at bridge site and local meteorological center together with existing finite element heat transfer theory and solar radiation transfer theory to determine the time dependent temperature distribution of bridge. In this analytical model, the most adequate equation for the calculation of solar radiation on the bridge surface, which is dominant in day time is described based on the results of several experimental studies for the solar energy. The validity of this model is tested against field data obtained from long term experimental program on Sadang Viaduct in Seoul. Also, this paper describes the linear correlation between design variables and meteorological data to establish analytical criteria for the prediction of the average temperature, which are responsible for the longitudinal deformation of the bridges and of the vertical differential temperature profiles. which are responsible for the bending deformations from the long term experimental results.

  • PDF

Evaluation of Structural Performance of Reinforced Concrete Beams According to Water Absorption of Recycled Coarse Aggregate (순환굵은골재 흡수율에 따른 철근콘크리트 보의 구조 성능 평가)

  • Kim, Sang Woo;Han, Dong Seok;Lee, Hyun Ah;Ko, Man Young;Kim, Kil Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.5
    • /
    • pp.49-58
    • /
    • 2012
  • This study estimates the flexural behavior of reinforced recycled aggregate concrete beams. Three specimens with different types and water absorption of coarse aggregates were constructed and tested. Not only all specimens were designed to be subjected to 4-point concentrated loads, but also the shear span-to-depth ratio of 2.5 was adjusted to all specimens to increase the effect of shear. A nonlinear flexural analysis considering the tension stiffening effect of concrete was performed to predict the moment versus curvature relationships of the specimens. Furthermore, a nonlinear finite element analysis considering the effect of shear was carried out to estimate the behavior of the specimens. It can be found from experimental results that the flexural strength and the crack properties of the specimens with recycled coarse aggregate having a water absorption of 6% were similar to those of the specimen with natural aggregates. The comparison between the experimental and analytical results showed that existing analytical methods can be successfully used to predict the behavior of reinforced recycled aggregate concrete beams.

The Strain Corrections for Accuracy Improvement to Predict Large Deformation of Wings (날개 대변형 예측의 정확성 향상을 위한 변형률 보정)

  • Lee, Hansol;Kim, In-Gul;Park, Sunghyun;Kim, Min-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • The information about the deformations of high-aspect-ratio wings is needed for the real-time monitoring of structural responses. Wing deformation in flight can be predicted by using relationship between the curvatures and the strains on the wing skin. It is also necessary to consider geometric nonlinearity when the large deformation of wing is occurred. The strain distribution on fixed-end is complex in the chordwise direction because of the geometric shape of fixed-wings on fuselages. Hence, the wing displacement can be diversely predicted by the location of the strain sensing lines in the chordwise direction. We conducted a study about prediction method of displacements regardless of the chordwise strain sensing locations. To correct spanwise strains, the ratio of spanwise strain to chordwise strain, Poisson's ratio, and the ratio of the plate strain to the beam strain were used. The predicted displacements using the strain correction were consistent with those calculated by the FEA and verified through the bending testing.

Analysis and Experiment on the Tape Spring Hinges for CubeSat Missions (큐브위성 임무를 위한 테이프 스프링 힌지의 비선형 거동 분석 및 실험)

  • Yoo, JeongUk;Im, Byeong-Uk;Shin, SangJoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.10
    • /
    • pp.712-719
    • /
    • 2019
  • This paper explores an implementation of finite element analysis and experiment in the design process of a tape spring hinge used for various CubeSat missions. Tape spring hinges consist of short-length hardened-steel strips with one-sided curvature, and thus the behavior is subject to large deformation with unpredicted non-linearity. Precise dimensions of a commercial tape spring are traced by the use of high-resolution digital camera, and thin-shell FEM analysis is conducted using ABAQUS program. Based on the rotation-moment analysis suggested in previous studies, parametric analysis is conducted by adjusting the contributing factors such as strip thickness and the subtended angle of the cross section. Finally the behaviors are investigated by both analytical and non-linear finite element methods, and the results are compared with the simple measurements. Further studies suggest a possible application in dynamic characteristics of hinges during CubeSat operations.

Design of Magnetic Systems for SNUT-79 Tokamak (SNUT-79 토카막의 자장 계통 설계)

  • Cheol Hee Nam;Sang Hee Hong;Kie Hyung Chung;Sang Ryul In
    • Nuclear Engineering and Technology
    • /
    • v.16 no.2
    • /
    • pp.89-96
    • /
    • 1984
  • A toroidal-field (TF) coil with a pure tension D-shape curve is designed for the confinement of high-temperature plasmas in the SNUT-79, which is a tokamak being built at Seoul National University. A toroidal assembly of 16 D-shape TF coils is designed to produce the magnetic field of up to 3T, of which ripples appear to be below 4% of the average toroidal field in the plasma region. Exact positions and currents in six equilibrium coils distributed symmetrically in the z=0 plane are found by the solution of a set of linear equations which is transformed from a Fredholm integral equation of the first kind. The decay indices resulted from equilibrium field indicate that the stability condition for vertical and horizontal displacements is satisfied.

  • PDF

Seismic Performance Evaluation of Curved Bridges by Gyeong-Ju Earthquakes (경주지진에 의한 곡선교량의 내진 안전성 평가)

  • Jeon, Jun-Tai
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.1
    • /
    • pp.43-50
    • /
    • 2018
  • This study presented 3D Finite Element (FE) analysis of curved beam structures subjected to static and dynamic loading conditions, which is particularly strong ground motions. It was shown that the results obtained from 3D FE analyses was similar to the theoretical solution within 1% convergency error, in order to validate the 3D solid FE models in this study. In particular, it was focusing on development of dynamic characteristics of curved beam structures subjected to three-different seismic ground motions: GyeongJu, Lomaprieta and Northridge earthquakes. Consequently, It was interesting to find that the results obtained from GyeongJu earthquake was detuned due to high frequency effect, but the Von-Mises of the curved beam structure under Lomaprieta earthquake was 647.824 MPa at 45 curvature degree.

A Study on the Ductility of Concrete-Filled Composite Columns under Cyclic Loading (반복하중을 받는 콘크리트충전 강합성 기둥의 연성에 관한 연구)

  • 송준엽;권영봉;김성곤
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.6
    • /
    • pp.11-19
    • /
    • 2001
  • A series of test on concrete-filled composite columns was preformed to evaluate structural performance under axial compression and cyclic lateral loading. It was presented that concrete-filled composite columns had high strength, high stiffness and large energy-absorption capacity on account of mutual confinement between the steel plate and filled-in concrete. A cross section analysis procedure developed to predict the moment-curvature relation of composite columns was proven to be on accurate and effective method. The ductility factor and the response modification factor were evaluated for the seismic design of concrete-filled composite columns. It was shown that concrete-filled composite columns could be used as a very efficient earthquake-resistant structural member.

  • PDF