• Title/Summary/Keyword: 선풍기 선정

Search Result 5, Processing Time 0.019 seconds

Development of a Low Pressure Auxiliary Fan for Local Large-opening Limestone Mines (대단면국내석회석광산용저풍압국부선풍기개발연구)

  • Lee, Chang Woo;Nguyen, Van Duc
    • Tunnel and Underground Space
    • /
    • v.25 no.6
    • /
    • pp.543-555
    • /
    • 2015
  • At present, local limestone mines with large opening employ auxiliary fans for workplace ventilation which have been used in coal mines with much smaller airways. Considering the low static pressure loss in the large-opening mines, high pressure auxiliary fans face serious economical limitations mainly due to their excessive capacity. The optimal fan selected for the ventilation in large-opening working places should supply air quantity enough for maintaining safe environment and keep its operating cost as low as possible. This study focuses on the development of a low pressure auxiliary fan designed to have smaller range of the static head but to have more potential for higher ventilation and energy efficiency. The flow characteristics of high and low pressure auxiliary fans were theoretical as well as experimentally investigated to assess the ventilation efficiency in term of environmental and economical aspects. Moreover, the low pressure fan was tested in two limestone mine sites with small and large cross-sectional areas for evaluating its ventilation efficiency. Results from this study can be applied to improve the economy and efficiency of auxiliary fan for ensuring better air quality and work environment management.

User-friendly adjustable table fan with selective rotation angles (사용 편의성 향상을 위한 선풍기의 효율적 회전구간 선정)

  • Kim, Sang-Hyun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.2
    • /
    • pp.53-58
    • /
    • 2022
  • Since a general household fan has only one left/right turning stage, the rotation angle cannot be adjusted leading to cases whether the wind reaches to an unnecessary area or vice versa. In this paper, we propose a method to efficiently control the turning section to selectively send wind to a necessary space while reducing energy waste. The minimum rotation angle was obtained by experimentally measured the stationary wind direction angle of the fan, and the optimal number of turning stages was selected by appropriately dividing the space where the wind reaches. Through this, it was confirmed that if the fan has a minimum rotation angle of 45°, a turning section of 3 stages and its rotation angle is increased by twice the stationary wind direction angle at each stage, the wind is distributed efficiently. Therefore, it is considered that the selective turning stage control proposed in this paper can minimize energy waste without significant change of the fan structure.

A Study on the Optimal Installation of Ducted Fan Ventilation System in Long Mine Airways - Focused on the Wall Separation Distance and the Gap Length between Ducts (장대 광산갱도내 풍관 접속 통기선풍기 최적 설치 방안연구 - 벽면과 풍관간의 이격거리 중심으로)

  • Lee, Chang Woo;Nguyen, Van Duc
    • Tunnel and Underground Space
    • /
    • v.27 no.1
    • /
    • pp.12-25
    • /
    • 2017
  • In local underground mines heavily depending on the natural ventilation, ducted fan auxiliary ventilation system is strongly recommended instead of the total mine ventilation system requiring large capital and operating costs. Optimizing the installation of ducted fans in series in long large-opening mines is required to assure the economy and efficiency of the ventilation system. The two most critical design parameters for optimization are the wall separation distance and gap length between adjoining ducts. This study aims at deriving the optimal values for those two parameters concerning the economic and environmental aspects through the extensive CFD analysis, which minimizes pressure loss, leakage and entrainment of the contaminated air in the gap space. The ranges of the wall separation distance and gap length for study are selected by taking into consideration the existing recommendations and guidelines. The ultimate goal is to optimize the auxiliary ventilation system using ducted fans in series to provide a reliable and efficient solution to maintain clean and safe workplace environment in local long underground mines.

Optimal Nozzle Design of Bladeless Fan Using Design of Experiments (실험계획법을 이용한 날개 없는 선풍기의 노즐 형상 최적 설계)

  • Jeong, Siyoung;Lee, Jongsoo;Yoon, Jaehyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.711-719
    • /
    • 2017
  • Bladeless fan is becoming increasingly popular owing to its advantages, such as improved safety, easy to clean, and attractive shape. However, many people are reluctant to purchase it because of several disadvantages, such as noise and moderate wind; therefore, research on how improve wind generation without increasing the motor speed is required. This study investigates the optimization of the shape of the nozzle and nearby surface using CFD (Computational Fluid Dynamics) simulation, ANSYS fluent. The results are analyzed by ANOM (analysis of mean) and interaction analysis; therefore this study suggests the variables of affecting Coanda effect and satisfy the govern equation, the conservation of momentum. The optimal combination was found through a predictive equation. In this study, factors and levels that affect the mass flow rate were selected and experimental points were arranged using the orthogonal array table. The value of the mass flow rate was confirmed by ANSYS fluent, which is a CFD program. Through the ANOM, it was confirmed that the nozzle distance is the most influential parameter affecting the mass flow rate. Furthermore, the mass flow rate obtained from the predictive equation and the mass flow rate from the CFD correspond to the largest values. Results from this study confirmed that the mass flow rate is increased by a change in the shape, even if the motor speed did not increase.

A Study on Ventilation System of Underground Low-Intermediate Radioactive Waste Repository (지하 동굴식 중-저준위 방사성 폐기물 처분장의 환기시스템 고찰)

  • Kim, Young-Min;Kwon, O-Sang;Yoon, Chan-Hoon;Kwon, Sang-Ki;Kim, Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.1
    • /
    • pp.65-78
    • /
    • 2007
  • The pollutants (Rn, CH, CO, HS, radioactive gas from radiolysis) were generated from the process of construction and operation of underground repository, and after disposal of low-intermediate radioactive waste inside there must be controlled by a ventilation system to distribute them in area where enough air is supported. Therefore, a suitable technical approach is needed especially at an underground repository that is equipped with many entry tunnels, storage tunnels, exhaust-blowing tunnels, and vertical shafts in complicated network form. For the technical approach of such a ventilation system, WIPP (Waste Isolation Pilot Plant) in U. S and SFR (Slutforvar for Reaktorafall) low-intermediate radioactive waste repository in Sweden were selected as the models, for calculating the required air quantity, organizing a ventilation network considering cross section, length, surface roughness of the air passage, and describing a calculation of resistance of each circuit. Based on these procedures, a best suited ventilation system was completed with designing proper capacity of fans and operating plan of vertical shafts. As a result of comparing the two repositories based on the geometry dimensions and ventilation facility equipment operation, more parallel circuit as in WIPP, brought decrease in resistance for entire system leading to reduce of operating costs, and the larger cross-sectional area of the SFR, the greater the percentage of disposal capacity. Accordingly, the mixture of parallel circuit of WIPP repository for reducing resistance and SFR repository formation for enlargement of disposal capacity would be the most rational and efficient ventilation system.

  • PDF