• Title/Summary/Keyword: 선원

Search Result 1,482, Processing Time 0.023 seconds

Coded Aperture Gamma Camera for Thyroid Imaging: Monte Carlo Simulation (갑상선 영상 획득을 위한 부호화 구경 감마카메라: 몬테칼로 시뮬레이션 연구)

  • Beak, Cheol-Ha;Lee, Seung-Jae;Chung, Yong-Hyun
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.247-255
    • /
    • 2008
  • A coded aperture camera has been developed to improve the signal-to-noise ratio (SNR) while keeping the spatial resolution of a pinhole gamma camera. The purpose of this study was to optimize a coded aperture camera and to evaluate its possibility for thyroid imaging by Monte Carlo simulation. A clinical gamma camera, a pinhole collimator with 1.0 mm hole diameter, and a $79{\times}79$ modified uniformly redundant array (MURA) mask were designed using GATE (Geant4 Application for Tomographic Emission). The penetration ratio, spatial resolution, integral uniformity and signal-to-noise ratio (SNR) were simulated and evaluated as a function of the mask thickness. The spatial resolution of the coded aperture camera was consistent with the various mask thickness, SNR showed a maximum value at 1.2 mm mask thickness and integral uniformity was improved by increasing mask thickness. Compare to the pinhole gamma camera, the coded aperture camera showed improved SNR by a factor of 30 while keeping almost the same spatial resolution. In this simulation study, the results indicated that high spatial resolution and ultra-high SNR of the thyroid imaging are feasible using a coded aperture camera.

  • PDF

A Study on the Selection of the Main Factors of Radiation Risk Index Model for assessing risk in Nondestructive Test workplace (방사선투과검사작업장 위험성 평가를 위한 방사선 위해도 지수 모델 주요인자 선정에 관한 연구)

  • Gwon, Da Yeong;Han, Ji young;Bae, Yu-Jung;Kim, Byeong-soo;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.459-466
    • /
    • 2018
  • Risk of radiation worker and radiation workplace are being mainly assessed by exposure dose. But, the radiation used in radiation workplace and the work environment are different. Because the nondestructive work environment varies depending on the work subject, the existence and nonexistence of shielding board, and so on. So, we need to consider the various factors in effective radiation protection aspect. We conducted a survey of radiation workers with over two years' experience in NDT workplace and heared the thoughts of experts. As a result, radiation source, exposure dose, current status of workplace management, workers with personel dosimetry problem and status of periodic regulatory inspection were chosen as main factors of radiation risk index model. Also, we primarily set weighting factors in order of importance based on questionnaires. Finally, we determined weighting factor for details of main factors through the professional advice. Therefore, we will be able to develop the radiation risk index model for assessing the risk of nondestructive test workplace based on main factors that are selected through this study.

Study of Radiation dose Evaluation using Monte Carlo Simulation while Treating Extrahepatic Bile Duct Cancer with High Dose Rate Intraluminal Brachytherapy (간외 담도암 고선량률 관내근접방사선치료 시 몬테카를로 시뮬레이션을 통한 주변장기의 선량평가 연구)

  • Park, Ju-Kyeong;Lee, Seung-Hoon;Cha, Seok-Yong;Lee, Sun-Young
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.2
    • /
    • pp.467-474
    • /
    • 2014
  • The relative dose calculated by MCNPX and the relative dose measured by ionization chamber and solid phantoms evaluated the accuracy comparing with Monte Carlo simulation. In order to apply Monte Carlo simulation the intraluminal brachytherapy of extrahepatic bile duct cancer, 192Ir sealed radioactive source replicate, Bile duct and surrounding organs were made using KMIRD phantom based on a South Korea standard man. To check the absorbed dose of normal organs around bile duct, we set the specific effective energy and initial radioactivity to 1 Ci using MCNPX. Evaluation of the accuracy of the Monte Carlo simulation, the difference of the relative dose is the most 1.96% that satisfy the criteria that is the relative error less than 2% suggested by MCNPX code. In addition, The specific effective energy and absorbed dose of normal organs that were relatively adjacent to bile duct such as right side of kidney, liver, pancreas, transverse colon, spinal cord, stomach and small intestine were relatively high. on the contrary, the organs that were relatively distant to bile duct such as left side of kidney, spleen, ascending colon, descending colon and sigmoid colon were relatively low.

A Study on Fujian Ships and Fujian Maritime Merchants ("복선(福船)"과 복건해상(福建海商)에 관한 연구(硏究))

  • Cui, Yun-Feng;Yu, Yao-Dong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.13 no.4
    • /
    • pp.101-105
    • /
    • 2007
  • The people who lived in Fujian district along the south-eastern coast of China long ago began to construct ships and go fishing. For this reason, they grasped sound navigation skills and gained rich navigation experience. These skills and experience laid basis for the following large-scale overseas trade. In the Tang dynasty, with the development of economy, the people who lived in Fujian district started to leave home town and engage in overseas trade. In the Song dynasty and the Yuan dynasty, with the fast development of overseas communication, more and more Fujian maritime merchants, navigating the Fujian ships which were safe, fast and could arrive at destination on time, engaged in overseas trade. The Fujian ships made it possible for the Fujian maritime merchants to shorten trade time, catch business opportunity, level up the chance of success in trade and make full use of capital. As a result of this, Fujian maritime merchants gained fast development and they reached far areas such as eastern Asia, south-eastern Asia, southern Asia, and eastern Africa. This study deals with the issues such as the reasons for the development of Fujian maritime merchants, the trade engaged in by Fujian maritime merchants, the Fujian ships which played a decisive role in the overseas trade of Fujian maritime merchants.

  • PDF

Concrete Degradation Comparison of Computer Programs for Post-Closure Safety Assessment of Wolsong Low-and Intermediate-Level Radioactive Waste Disposal Facility (월성원자력환경관리센터 폐쇄 후 안전평가 컴퓨터프로그램의 콘크리트 열화현상에 대한 상호비교)

  • Jung, Kang-Il;Bang, Je-Heon;Park, Jin Beak;Yoon, Jeong Hyoun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.4
    • /
    • pp.311-324
    • /
    • 2013
  • To ensure the reliability of computer programs used for the post-closure safety assessment in the Wolsong LILW Center, the results from MASCOT, SAFE-ROCK and GOLDSIM programs are compared with a problem for degradation. Advantages and disadvantages of each computer programs are individually analyzed. Effects on the individual dose are assessed with each computer programs. MASCOT and SAFE-ROCK showed similar results for $^{129}I$ and $^3H$. However, GOLDSIM represented different results for $^{129}I$ and $^3H$. It is analyzed further and compared with the fluxes in each barrier of the disposal system. Througout the benchmarking testing of the computer program, the limitation of computer program can be continuously found out for the mature post-closure safety of Korean radwaste disposal system.

A Study on the Assessment of Source-term for PWR Primary System Using MonteCarlo Code (MonteCarlo 코드를 이용한 PWR 일차 계통 선원항 평가에 관한 연구)

  • Song, Jong Soon;Lee, Sang Heon;Shin, Seung Su
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.331-337
    • /
    • 2018
  • The decommissioning of nuclear power plants is generally executed in five steps, including preparation, decontamination, cutting/demolition, waste disposal and environmental restoration. So, for efficient decommissioning of nuclear power plants, worker safety, effects compared to cost, minimization of waste, possibility of reuse, etc., shall be considered. Worker safety and measurement technology shall be secured to exert optimal efficiency of nuclear power plant decommissioning work, for which accurate measurement technology for systems and devices is necessary. Typical In-Situ methods for decommissioning of nuclear plants are CZT, Gamma Camera and ISOCS. This study used ISOCS, which can be applied during the decommissioning of a nuclear power plant site without collecting representative samples, to take measurements of the S/G Water Chamber. To validate the measurement values, Microshield and the GEANT4 code was used as the actual method were used for modeling, respectively. The comparison showed a difference of $1.0{\times}10^1Bq$, which indicates that it will be possible to reduce errors due to the influence of radiation in the natural environment and the precision of modeling. Based on the research results of this paper, accuracy and reliability of measurement values will be analyzed and the applicability of the direct measurement method during the decommissioning of NPPs will be assessed.

QA/QC for 222Rn analysis in groundwater (지하수 중 222Rn 분석을 위한 정도관리)

  • Jeong, Do Hwan;Kim, Moon Su;Kim, Hyun Koo;Kim, Hye Jin;Park, Sun Hwa;Han, Jin Seok;Ju, Byoung Kyu;Jeon, Sang Ho;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.86-90
    • /
    • 2013
  • $^{222}Rn$ concentrations in the groundwater samples without standard material due to the short half-life (3.82 day) were measured through the establishment of the counting efficiency of LSC (Liquid Scintillation Counter) using a standard source of $^{226}Ra$. This study for Quality Assurance/Quality Control (QA/QC) of $^{222}Rn$ analysis was performed to analyze blank samples, duplicate samples, samples of groundwater sampling before and after. In-situ blank samples collected were in the range of 0.44~6.28 pCi/L and laboratory samples were in the range of 1.66~4.95 pCi/L. Their correlation coefficient was 0.9691 and the source contamination from sampling, migration and keeping of samples were not identified. The correlation coefficient between original and duplicate samples from 65 areas was 0.9987. Because radon is an inert gas, in case of groundwater sampling, it is considered to affect the radon concentration. We analyzed samples separately by groundwater sampling before and after using distilled water, but there is no significant difference for $^{222}Rn$ concentrations in distilled waters of two types.

Calculation of depth dose for irregularly shaped electron fields (부정형 전자선 조사면의 심부선량과 출력비의 계산)

  • Lee, Byoung-Koo;Lee, Sang-Rok;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.79-84
    • /
    • 2002
  • The main cause factor for effective the output, especially in small & irregular shaped field of electron beam therapy, are collimation system, insert block diameter and energy. In the absorption deose of treatment fields, we should consider the lateral build-up ratio (LBR), which the ratio of dose at a point at depth for a given circular field to the dose at the same point for a 'broad-field', for the same incident fluence and profile. The LBR data for a small circular field are used to extract radial spread of the pencil beam, ${\sigma}$, as a function of depth and energy. It's based on elementary pencil beam. We consider availability of the factor, ${\sigma}$, in the small & irregular fields electron beam treatment.

  • PDF

Practicability Assessment of Spherical Type Mechanical Check Device (SMCD) (Mechanical Check용 Spherical Device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Kim, Gun-Oh;Kweon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.55-62
    • /
    • 2007
  • Purpose: Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and medical treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation therapy area. In order to accommodate the current trend of digital from analog, a spherical type mechanical check device (SMCD) that is form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. Materials and Methods: If the distance maintains constant between source(target) and image detector with constant distance to the center of spherical type mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. Results: It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. Conclusion: It has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF

Investigation into Occupational Disease of Merchant Crew (상선승무원들의 질병실태 조사)

  • Kim Jae-Ho;Chang Seong-Rok;Moon Serng-Bae;Ha Hae-Dong;Yang Won-Jae;Lee Sang-Woo
    • Journal of Navigation and Port Research
    • /
    • v.30 no.6 s.112
    • /
    • pp.551-559
    • /
    • 2006
  • The purpose of this study was to find out morbidity rate and pattern of disease and affect of variables related disease and medical management of seafares'. The subjects this study were 1049 seafares' were took education in Korea Institute of Maritime and Fisheries Technology. This questionnaire was focused on finding the basic data for prevention of disease and promotion health for the seafares'. The collected data were analyzed by using descriptive statistics, Chi-square, cross tab, linear regression by SPSS 10.1 package. The result of this study are as follow. 1)The morbidity rate within recent 12 months was 69.0%. 2)there were significant differences qf occurred disease in age(p<0.05), income(p<0.01), career of ship on board(p<0.01), rank(p<.01), perceived health status(p<0.01), worry of health(p<0.01), fatigue symptoms(0.01), satisfy of job(p<0.05), rest time(p<0.05) 3) Considering disease unable to work more than 4 hour, the number of those who had oral disease 7.3%> tinea 6.6%> gastric ulcer 6.4, and musculoskeletal disease group were 20.9%, which revealed the highest rate oral disease 13.6%> skin disease> 12.4%, digestive disease> 12.1%. 4) As refer to medical management, The pain above 31days 35.7%, hospitalization and treatment below 7days were each 50.2%, 42.8%, medical service were doctor's office 27.9, which revealed the highest rate.