• Title/Summary/Keyword: 선원전

Search Result 105, Processing Time 0.029 seconds

Evaluation of Contrast and Resolution on the SPECT of Pre and Post Scatter Correction (산란보정 전, 후의 SPECT 대조도 및 분해능 평가)

  • Seo, Myeong-Deok;Kim, Yeong-Seon;Jeong, Yo-Cheon;Lee, Wan-Kyu;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.127-132
    • /
    • 2010
  • Purpose: Because of limitation of image acquisition method and acquisition time, scatter correction cannot perform easily in SPECT study. But in our hospital, could provide to clinic doctor of scatter corrected images, through introduction of new generation gamma camera has function of simple scatter correction. Taking this opportunity, we will compare scatter corrected and non-scatter corrected image from image quality of point of view. Materials and Methods: We acquisite the 'Hoffman brain phantom' SPECT image and '1mm line phantom' SPECT image, each 18 times, with GE Infinia Hawkeye 4, SPECT-CT gamma camera. At first, we calculated each contrast from axial slice of scatter corrected and non-scatter corrected SPECT image of 'Hoffman brain phantom'. and next, calculated each FWHM of horizontal and vertical from axial slice of scatter corrected and non-scatter corrected SPECT image of '1mm line phantom'. After then, we attempted T test analysis with SAS program on data, contrast and resolution value of scatter corrected and non-scatter corrected image. Results: The contrast of scatter corrected image, elevated from 0.3979 to 0.3509. And the resolution of scatter corrected image, elevated from 3.4822 to 3.6375. p value were 0.0097 in contrast and <0.0001 in resolution. We knew the fact that do improve of contrast and resolution through scatter correction. Conclusion: We got the improved SPECT image through simple and easy way, scatter correct. We will expect to provide improved images, from contrast and resolution point of view. to our clinic doctor.

  • PDF

The Study of Radiation Reducing Method during Injection Radiopharmaceuticals (방사성의약품 투여 시 피폭선량 저감에 대한 연구)

  • Cho, Seok-Won;Jung, Seok;Park, June-Young;Oh, Shin-Hyun;NamKoong, Hyuk;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.80-85
    • /
    • 2012
  • Purpose: The whole body bone scan is an examination that visualizing physiological change of bones and using bone-congenial radiopharmaceutical. The patients are intravenous injected radiopharmaceutical which labeled with radioactive isotope ($^{99m}Tc$) emitting 140 keV gammarays and scanned after injection. The 3 principles of radiation protection from external exposureare time, distance and shielding. On the 3 principles of radiation protection basis, radiopharmaceutical might just as well be injected rapidly for reducing radiation because it might be the unopened radiation source. However the radiopharmaceuticals are injected into patient directly and there is a limitation of distance control. This study confirmed the change of radiation exposure as change of distance from radiopharmaceutical and observed the change of radiation exposure afte rsetting a shelter for help to control radio-technician's exposure. Materials & methods: For calculate the average of injection time, the trained injector measured the injection time for 50 times and calculated the average (2 minutes). We made a source as filled the 99mTc-HDP 925 MBq 0.2 mL in a 1 mL syringe and measured the radiation exposure from 50 cm,100 cm,150 cm and 200 cm by using Geiger-Mueller counter (FH-40, Thermo Scientific, USA). Then we settled a lead shielding (lead equivalent 6 mm) from the source 25 cm distance and measured the radiation exposure from 50 cm distance. For verify the reproducibility, the measurement was done among 20 times. The correlation between before and after shielding was verified by using SPSS (ver. 18) as paired t-test. Results: The radiation doses according to distance during 2 minutes from the source without shielding were $1.986{\pm}0.052{\mu}$ Sv in 50 cm, $0.515{\pm}0.022{\mu}$ Sv in 100 cm, $0.251{\pm}0.012{\mu}$ Sv in 150 cm, $0.148{\pm}0.006{\mu}$ Sv in 200 cm. After setting the shielding, the radiation dose was $0.035{\pm}0.003{\mu}$ Sv. Therefore, there was a statistical significant difference between the radiation doses with shielding and without shielding ($p$<0.001). Conclusion: Because the great importance of whole body bone scan in the nuclear medicine, we should make an effort to reduce radiation exposure during radiopharmaceutical injections by referring the principles of radiation protection from external exposure. However there is a limitation of distance for direct injection and time for patients having attenuated tubules. We confirmed the reduction of radiation exposure by increasing distance. In case of setting shield from source 25 cm away, we confirmed reducing of radiation exposure. Therefore it would be better for reducing of radiation exposure to using shield during radiopharmaceutical injection.

  • PDF

관제영어의 특성 및 교육발전 방안에 대한 고찰

  • Jeong, Byeong-U;Park, Jong-Ik
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.10a
    • /
    • pp.190-193
    • /
    • 2010
  • 최근 해상교통관제사의 자격제도 및 평가제 제도의 도입이 활발하게 논의되고 있다. 전 세계의 상선대가 비영어상용국 출신의 다국적 선원으로 채워진 현실에서 관제사의 영어 구술능력 배양은 시급한 과제이다. 본 연구에서는 실제 현장에서의 선박항해자와 관제사간의 영어구사 현황을 중점적으로 살펴보고, SMCP에 규정된 표준관제영어와의 괴리를 지적하였다. 관제영어 학습 커리큘럼을 현장의 상황위주로 재구성할 것을 제안하였으며 항공분야에서 실시하고 있는 항공영어구술능력 평가 제도를 참고하여 해상교통관제 영어구술능력 평가 제도를 모색하여 보았다.

  • PDF

선박조종시뮬레이터를 이용한 해적 대응훈련에 대하여

  • Lee, Dong-Seop
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.10a
    • /
    • pp.105-106
    • /
    • 2013
  • 2011년 1월 21일 새벽 대한민국 해군 청해부두는 "아던만의 여명"이라는 작전명으로 소말리아 해적에 납치되었던 M/T "삼호주얼리"호를 구출하였으며, 이 작전결과 피납선박 및 선원 21명을 구조하였으며 작전 중 선장이 부상을 입었으며 해적 8명을 사살하고 5명을 생포하는 전과를 올렸다. 한국해양수산연수원은 2011년도 도입한 Full-mission Shiphandling Simulaor(다기능 선박조종시뮬레이터)를 설치하면서 항행, 조종훈련 및 비상, 선교조직훈련 뿐 만 아니라 Offshore훈련과 Dynamic Positioning System Operator훈련, Ice Navigation훈련, 테러방지 훈련(Anti-Terror Training) 및 해적대항 훈련(Anti-Piracy Training) 등 Crisis Management훈련을 할 수 있는 기능을 추가하였으며, 특히, 테러방지 훈련(Anti-Terror Training) 및 해적대항 훈련(Anti-Piracy Training)에 대한 훈련과정을 소개하고자 한다.

  • PDF

여성해기사의 해상진출을 위한 국제기구의 역량강화 연구

  • Jo, So-Hyeon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.06a
    • /
    • pp.457-458
    • /
    • 2013
  • 전 세계 1내지 2 퍼센트에 해당하는 여성선원 중 상선에 종사하는 여성해기사는 그 중 6 퍼센트에 해당한다. 해운 산업의 구성 인력 중 소수라고 할 수 있으나 여성의 원활한 해상 진출을 위해 국제해사기구를 비롯하여 정부, 교육단체, 노조 및 해운선사들의 지원과 관심이 필요한 시점이다. 이에 그 동안 국제해사기구를 비롯하여 여성해기사를 위한 현존 지원 정책을 살펴 보고, 향후 여성해기사의 역량강화 및 해상진출을 위한 제도적, 정책적 요소들을 식별하였다.

  • PDF

Slab Thickness Calculations on Hot Cell

  • Ha, Yung-Joon;Kim, Seong-Yun;Kim, Dong-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.26-36
    • /
    • 1978
  • Numerical computations of radioactivities and decay energies in a spent fuel have been carried out for designing of a hot cell. Optimum wall and window thicknesses that can preserve spent fuel rods for experimental purposes are estimated with burnup rate of 33,000 MWD/T(U) which is nearly maximum from a pressurized water reactor such as the Go-Ri Unit 1. Before putting the spent fuels into a hot cell, it is assumed for thickness estimates of shield materials that they are cooled in a storage tay for several lime intervals. Considered are various types of shield materials through which changing the distances from a source to an observation point is also made.

  • PDF

A Study on Construction of Giroso Youngsugak in the Joseon Dynasty (조선시대 기로소 영수각 조영에 관한 연구)

  • Kim, Suk-Hyun
    • Journal of architectural history
    • /
    • v.32 no.4
    • /
    • pp.35-50
    • /
    • 2023
  • This study aims to investigate the history of Giroso during the early Joseon Dynasty, examine the authenticity of the history regarding Taejo's admission to Giroso, and identify the background and architectural form of Giroso Youngsugak. Research confirms that Taejo joined Giroso in 1394 at the age of 60, but there is no evidence of his name being recorded in the Giroso Seoru. Giyeonghoe(耆英會) has been frequently suspended since the 16th century, and after the Japanese Invasion of Joseon in 1592, the king's permission for Giyeonghoe was not readily granted. Taejo's admission to Giroso and the story of Giroso Seoru started emerging as a justification for resuming Giyeonghoe. When King Sukjong joined Giroso, a new building called Youngsugak was required to enshrine Eochup(royal writings), and it was modeled after Jongbushi Seonwongak. Although Youngsugak no longer exists, the form of Giroso Youngsugak from the past can be observed through Uiseong Gounsa Yeonsujeon, which was constructed in 1904 based on the model of Giroso Youngsugak.

Measuring external Radiation dose Ratio by Traits of Patients during Positron Emission Tomography(PET) (양전자단층촬영(PET)시 환자의 특성에 따른 외부 방사선량률 측정)

  • Cho, Yong-Gwi;Kim, Sung-Chul;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.860-868
    • /
    • 2013
  • The purpose of this study is to ensure safety by measuring External radiation dose ratio (ERDR) by traits of patients in many ways after administering radiopharmaceutical($^{18}F$-FDG) for PET Torso scan, and to decrease ERDR of those to RI technologist, caretakers, and those who frequently exposed to radiation by arousing attention to radiation dose. Radiopharmaceutical was administered to 80 patients who conducted PET Torso from January to June, 2013. Radiation dose emitted from the patients was measured according to body shape(BMI), water hydration, height, amount of radiation administration. From the moment immediately after the radiopharmaceutical was administered, ERDR was measured by personal traits of patients. The radiation dose increased in proportion to the administered amount of the radiopharmaceutical, and there was no significant difference depending on the body shape of the patients. When water was supplied and the height was normal, the radiation dose was lower compared with the cases where water was not supplied and height was not normal. There is a need for making efforts to minimize the working time through sufficient education and mock training before those who RI technologist with sources of radiation for complying the radiation safety management rule. And they should minimize the ERDR by wearing a protective gear.

Analysis of Satisfaction and Effectiveness of On-board Medical Education - For Crew and Medical Managers before Boarding - (선상 의료교육의 만족도와 효과에 대한 분석 - 승선 전 선원 및 의료관리자를 대상으로 -)

  • Lee, Chang-Min;Park, Tae-Hyun;Choi, Byung-Kwan
    • Journal of Navigation and Port Research
    • /
    • v.42 no.4
    • /
    • pp.291-298
    • /
    • 2018
  • The purpose of this study was to analyze the effectiveness of on-board medical education for crew and medical managers. The satisfaction of the crew and the medical managers after undergoing the medical education was selected as a measure of effectiveness. The data collection period extended from October 2015 to March 2018 for about 2 years and 6 months, and a total of 310 questionnaires were collected and sampled. However, in this study, regression analysis was performed with only 96 samples because of the addition and modification of questionnaire items in the regression analysis. This study investigated the effect of on-board medical educational assistance (trauma education, nursing care, CPR, and overall educational content) and control variables (total boarding career, age, final education, and education year) on satisfaction. The important findings were as follows: i) Higher the degree of trauma education, higher was the satisfaction, ii) higher the degree of overall educational content, higher was the satisfaction, iii) higher the degree of CPR education, higher was the satisfaction, iv) increased total boarding career reduced the satisfaction level, v) and higher the final education, higher was the satisfaction.

Preliminary Post-closure Safety Assessment of Disposal Options for Disused Sealed Radioactive Source (폐밀봉선원 처분방식별 폐쇄후 예비안전성평가)

  • Lee, Seunghee;Kim, Juyoul;Kim, Sukhoon
    • Economic and Environmental Geology
    • /
    • v.49 no.4
    • /
    • pp.301-314
    • /
    • 2016
  • Disused Sealed Radioactive Sources (DSRSs) are stored temporally in the centralized storage facility of Korea Radioactive Waste Agency (KORAD) and planned to be disposed in the low- and intermediate-level radioactive waste (LILW) disposal facility in Gyeongju city. In this study, preliminary post-closure safety assessment was performed for DSRSs in order to draw up an optimum disposal plan. Two types of disposal options were considered, i.e. engineered vault type disposal and rock cavern type disposal which were planned to be constructed and operated respectively in LILW disposal facility in Gyeongju city. Assessment end-point was individual effective dose of critical group and calculated by using GoldSim code. In normal scenario, the maximum dose was estimated to be approximately $1{\times}10^{-7}mSv/yr$ for both disposal options. It meant that both options had sufficient safety margin when compared with regulatory limit (0.1 mSv/yr). Otherwise, in well scenario, the maximum dose exceeded regulatory limit of 1 mSv/yr in engineered vault type disposal and the exposure dose was mainly contributed by $^{226}Ra$, $^{210}Pb$ (daughter nuclide of $^{226}Ra$) and $^{237}Np$ (daughter nuclide of $^{241}Am$). For rock cavern type disposal, even though the peak dose satisfied regulatory limit, the exposure doses by $^{14}C$ and $^{237}Np$ were relatively high above 10% of regulatory limit. Therefore, it is necessary to exclude $^{14}C$, $^{226}Ra$ and $^{241}Am$ for two type of disposal options and additional management such as long-term storage and development of disposal container for those radionuclides should be performed before permanent disposal for conservative safety and security.