• Title/Summary/Keyword: 선로사용

Search Result 741, Processing Time 0.024 seconds

Stepped Impedance LPF Using MCS Line with Ground (접지가 있는 MCS 선로를 이용한 스텝 임피던스 저역 필터)

  • Rhee, Seung-Yeop;Lee, Yong-Kook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.11
    • /
    • pp.1248-1253
    • /
    • 2008
  • The MCS(Micro-Coplanar Strip) line with ground has been analyzed. The conformal mapping method is used to calculate the quasi-static effective dielectric constant and characteristic impedance of this MCS line. The computed results of the present work are found to be in good agreement when compared with the results obtained using commercial S/W, IE3D. And in this paper, the stepped-impedance low pass filter is designed and fabricated with MCS lines for improving the frequency responses. The LPF proposed structure has been also designed and implemented to have the sharp attenuation characteristics in stop band. The agreement between simulation and measurement results verify the implemented LPF.

Analysis of Characteristics of Residential Distribution Line for Design of Power Line Communication Systems (전력선 통신 시스템 설계를 위한 주택배선의 선로특성 분석)

  • Hong, Ducpyo;Choi, Jaeho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.99-104
    • /
    • 2005
  • This paper describes the measurement and analysis of the basic line constants in PLC(Power Line Communication) in the residential building. An apartment is considered as one of the conventional residences to get the line constants in this paper, Agilent 4263B LCR Meter is used to measure the detailed values each area and the specific results and averaged analysis data are shown in the tables. The measured results are a little bit different from the calculated values using conventional formula due to the line arrangement, neglected factors, complex permittivity, and etc. This paper describes many kinds of lines and wiring figures of domestic construction. It can be utilized with the analyzed line characteristics in frequency domain as a planning reference of PLC.

A Study on Wideband Microstrip Array Antennas Using the Parallel Coupled Lines (펑행 결합 선로를 이용한 광대역 마이크로스트립 배열 안테나에 관한 연구)

  • 김정일;한만군;윤영중
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.12B
    • /
    • pp.1724-1732
    • /
    • 2001
  • In this paper, a technique for increasing the bandwidth of microstrip array antennas using the parallel coupled lines on a single layer is presented. Four types of wideband microstrip array antenna are designed and the characteristics of each type are analyzed. In addition, an iterative method using a distributed network is proposed to design the parallel coupled lines as a wideband impedance matching network. Measurements show that the proposed antennas provide wider bandwidths ∼1.7 times those of conventional microstirp array antennas, while the sizes of proposed antennal are the same as that of a conventional array. And low cross-polarization level can be obtained through symmetrical locations of the parallel coupled lines section

  • PDF

Estimation for the Transfer Function of Transmission Line using the Temination and Input Impedances at Activated/Deactivated states (활성/비활성 상태에서의 종단과 입력 임피던스 변화를 이용한 전송선로의 전달함수 추정)

  • 이종헌;진용옥
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.1
    • /
    • pp.90-97
    • /
    • 1992
  • An estimation method for the amplitude and phase response of transmission line is discussed. and applied to narrow band ISDN subscriber line. The ABCD parameters of line are evaluated from four impedance values: the standard termination impedence at activated and deactivated stares, and the input impedances of line which can be estimated at each state. Estimating input impedence, the “chirp” signal is used as incident signal and noise effect can be reduced by ensemble averaging. These ABCD parameter estimations might be applicable to ether uniform or nonuniform line. Cleary the magnitude and phase response can be obtained from estimated ABCD parameters. The numerical simulation results for N ISDN subscriber line model are included, and the estimation error introduced by deviation in load impedence is also anlyzed.

  • PDF

Propagation Characteristics of Picosecond Gaussian Pulses in Coplanar Waveguides using Time Domain Measurement (시간영역 측정을 이용한 CPW에서 가우시안 펄스 전송 특성)

  • 이승엽;신용섭
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.11
    • /
    • pp.1143-1148
    • /
    • 2003
  • The distortion of picosecond pulses caused by dispersion as it propagates along microstripline and CPW(Coplanar waveguide) is investigated and measured using time domain measurement. Especially, this study presents that the distortion of these lines is analyzed and compared considering the relation between the dispersion effect and cut-off frequency(f$\_$TE/) of fundamental TE mode for the substrate of line. To verify theoretical results, several samples of 50 $\Omega$ lines are fabricated on the two kind of substrates with the different values of f$\_$TE/. The propagation characteristics of picosecond Gaussian pulse on thess lines are simply measured using VNA(Vector Network Analyzer) with the time-domain analysis function.

A Systematic Review and Meta-Analysis of the Effects of Simultaneous Dual-Task Training on Executive Function in Older Adults (동시적 이중과제 훈련이 노인의 실행기능에 미치는 효과: 체계적 고찰 및 메타분석)

  • Jeun, Yu-Jin;Park, Jin-Hyuck
    • Therapeutic Science for Rehabilitation
    • /
    • v.10 no.3
    • /
    • pp.23-41
    • /
    • 2021
  • Objective : The purpose of this study was to analyze the effects of simultaneous dual-task training to assess executive function in older adults. Methods : We searched the PubMed, EMBASE, Cochrane, Web of Science, and RISS databases of publicated studies in the past decade. Seven studies were selected based on the inclusion and exclusion criteria. Qualitative assessment and meta-analysis were performed for the seven studies. Results : A randomized controlled trial design was used in the selected studies, and PEDro Scores above seven were obtained. The Trial Making Test (TMT) evaluated the effects of dual-task training on executive function in four studies. The Color Trail Test (CTT) was used in two studies, and Stroop test was used in three studies. The effect size for total executive function was 0.38, which was small. The effect sizes for TMT and CTT were 0.37. Stroop Test was 0.34, demonstrating that their effect sizes were also small. Only significant effects in total executive function, TMT, and CTT showed significant effects (all p<0.05). Conclusion : This study confirmed that dual-task training was effective in improving executive function in older adults. To improve the effectiveness of dual-task training, the difficulty of the dual-task training should be considered. It is also necessary to implement assessments that can evaluate performance under dual-task conditions as well as conventional test tools for executive function. In the future, dual-task training could be used as an appropriate intervention for executive function in older adults to delay the onset of dementia.

The Site Installation Test of Single-Phase MJ81 Switch Point Machine Localization (단상 MJ81 전기선로전환기 국산품의 현장설치시험)

  • Baek, Jong-Hyen;Kim, Yong-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3632-3637
    • /
    • 2009
  • In this paper, we describe the performance results of the field installation test which is required to practicalize the single-phase MJ81 Switch Point Machine. This product has passed the certified test through performance improvement of driving parts in order to use 3 phase MJ81 Switch Point Machine, which is localized by taking over technology from Alstom and Cogifer when constructing Seoul-Busan rapid-transit railway, without change of the electrical equipment at track-side in domestic existing lines which single-phase 220V is used. KRRI and Samsung SDS have localized the single-phase MJ81 Switch Point Machine to improve the speed and safety of the conventional lines through the existing railway technology development project. For practicalization of this, we should, however, verify the performance through not only field installation test in real lines but also interface test with the interlocking. In this paper we verify the practicality of the domestic single-phase MJ81 Switch Point Machine through analysis on the performance result of the field installation test as well as the research contents for this test. Thereby, in Feb 2009 we have received an order from the Korea Rail Network Authority and are currently installing the single-phase MJ81 Switch Point Machine.

Analysis and improvement of transfer power capability considering movable load charging of EV (전기자동차 충전부하의 이동성을 고려한 전송 전력량의 해석 및 개선)

  • Kim, Deok Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.762-767
    • /
    • 2017
  • This paper presents an analysis for improving the power transfer capability in transmission lines caused by the movable load charging of electric vehicles (EVs). EVs are expected to be used more widely and replace gas fuel vehicles in the near future due to the shortage of fossil fuels and for environmental preservation. Movable load charging of EVs could lead to the convergence of transferred power flow and overloading conditions in transmission lines in a specific area of a power system, which is conventionally based on estimated fixed load capability. To analyze these conditions, the New England Test System was divided into four regions based on the load characteristics, and different charging scenarios were considered. In these scenarios, the regional power load was highly increased to 31% based on the standard charging capacity of an EV. As a solution to the overloading problem of transmission lines, a TCSC was installed serially on the overloaded line to directly control the transferred power under limited line capability (100% load capability). The simulation showed that the application of a few TCSCs could efficiently and economically control the line capability problem caused by movable load charging of EVs.

The Improvement of Electrical Point Machine Wiring Set (선로전환기(NS)의 배선세트 개선)

  • Jeong, Rag-Gyo;Park, Gun-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.351-358
    • /
    • 2016
  • An Electrical Point Machine (NS:New-type Switch), which is equipped and operated at railways in Korea, has been used since the 1960s after being imported from Japan. On the other hand, although the mechanical configuration has improved the position motor control circuit, the electrical connection has not been improved, so NS may have a problem, such as the interlocking system of automatic train operation. In addition, NS is the most vulnerable part in the railway system and a huge train accident may occur due to minor defects. The existing NS wiring set of the circuit controller should be checked only if fixed. Therefore, an excessive inspection time only by a Railroad Signal expert is required. In this paper, the improvement of electrical connection in a NS wiring set, such as the position motor control circuit, was developed and the prototype was installed at Seoul Metro in the distance to go section. The results can be used to help make appropriate adjustments. The improvement of the NS wiring set enhance the maintenance efficiency, passenger service and the stability of the signal system as well as reducing the maintenance cost.

Insertion Loss Characteristics of a Parallel Two-Wire Transmission Line with Equal Line Length Due to a Rectangular Aperture Sizes in Dual Ground Planes (두 개의 접지 평판 사각형 개구의 변화에 따른 평행 2선 전송 선로의 삽입 손실 특성)

  • Jung, Sung-Woo;Lim, Sung-Min;Jin, Jung-Hi;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.7
    • /
    • pp.675-682
    • /
    • 2011
  • This paper presents two ground plane effects due to the size of two rectangular apertures for two-wire transmission line with equal line length crossing the changeable rectangular apertures in infinite ground planes. The CST MWS is used to determine the characteristics of the insertion loss of the transmission line from the load section in accordance with the ground plane aperture size. The results show that the insertion gain and the insertion loss are periodically observed for the multiple frequency of the half wavelength resonance by the wire length when the transmission line is nearby to horizontal side or vertical side of the aperture. The measurements of the insertion loss are performed to verify the theoretical analysis.