• Title/Summary/Keyword: 선량 확인

Search Result 1,101, Processing Time 0.027 seconds

Clinical Implementation of a Virtual-Micro MLC for Smoothing MLC Field Edge (다엽콜리메이터에 의한 조사경계면에서의 요동현상을 완화시켜주는 가상미세다엽콜리메이터의 임상 적용)

  • Cho Byung-Chul;Park Hee-Chul;Bae Hoonsik
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.167-172
    • /
    • 2004
  • A Siemens HD-270 MLC$^{TM}$, a virtual-micro MLC, allows to the application of a smooth field edge method due to the finite leaf-width of MLC. This technique was implemented into a Pinnacle planning system in order to evaluate the dose distributions during the planning stage. The necessary dosimetric aspects, such as undulation and effective penumbra, were investigated with variations in the resolutions of a virtual-micro MLC and field edge angle. The positional accuracy of the couch movement was also assessed for clinical implementation. The overhead time for planning and treatment was confirmed as negligible.e.

  • PDF

Pulse Radiation Dose Measurement using the Peak Detector (Peak Detector를 이용한 펄스방사선 선량 측정)

  • Jeong, Sang-hun;Lee, Nam-ho;Oh, Seong-chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.1020-1022
    • /
    • 2013
  • In this paper, proposed peak detector for the measurement of pulse radiation dose. The speed of the pulse radiation signal is the between a few ns and tens ns. Therefore, it is difficult to measure peak voltage. Peak Detector maintains the peak voltage generated from the sensor for a few ms and the converted signals can be easily measured using the ADC. The peak detector simulation results peak value remained of more than 1ms. Pulse radiation irradiation test results, a dose of $1.95{\times}10^6rad/s$ was measured.

  • PDF

Study of Histochemical Changes of Mouse Ovary Under X-ray Irradiation (방사선 조사선량에 따른 생쥐 난소의 조직화학적 변화)

  • Yoon, Chul-Ho
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.275-284
    • /
    • 2006
  • This research investigated the morphological changes of folliculus ovary according to the dose of the X-rays when mice were exposed to X-rays, in terms of histochemical reaction. Dyeing methods such as Masson's trichrome method and reticular fiber method were used. The morphological changes of growing folliculus ovary got distinct as the dose of X-rays increased. Especially, the nuclei of granular cells showed manifest condensation and the changes of the transparent zone were distinct. As a result of histochemical reaction according to Masson's trichrome method and reticular fiber method, the changed granular cells, the deformed basilar membrane of folliculus ovary and the abnormal arrangement of the reticular fiber were observed.

  • PDF

The Usefulness Assessment of Verifying Daily Output by Using CHECKMATE$^{TM}$ (CHECKMATE$^{TM}$를 이용한 일일 출력 검증의 유용성 평가)

  • Cho, Han-Sang;Nam, Sang-Soo;Park, Hae-Jin;Kim, Mi-Hwa;Park, An-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • Purpose: In this study, we tried to check the usefulness of two Linear Accelerators, Clinac IX and 21EX (Varian, Palo Alto, CA), which are equipped in Ajou Medical Center. From 2008 to 2010, we evaluated the error range of Absolute Dose based on the daily output, which was measured by CHECKMATE$^{TM}$ (Sun Nuclear, Melbourne, FL). Materials and Methods: For Daily Q.A, photon beams of two linear accelerators, 21EX and IX (6 MV and 10 MV, respectively) were measured daily by using CHECKMATE$^{TM}$ just before the treatment began, while the absolute dose was measured biweekly by using water phantom. We analyzed the data of measured values from the daily Q.A and the absolute dose from 2008 to 2010 for 21EX, and from 2009 to 2010 for IX. We utilized Excel 2007 (Microsoft, USA) to evaluate Average, Standard deviation and Confidence level of the data. Furthermore, in order to check the measured values of CHECKMATE$^{TM}$ and the significance of absolute dose, each error value was compared and analyzed. Results: During the observation period, the output of two equipment's absolute dose increased in process of time and in both 6 MV and 10 MV, there was a similar increasing trend. In addition, the error rate of the measured value of CHECKMATE$^{TM}$ and the value of absolute dose were under 0.34, which means that there is a similarity relationship between the two measured values. After checking that the measured value of CHECKMATE$^{TM}$ increased, We measured the absolute dose to adjust that. When the error range was close to 2~3%, the number of changing the output was four for 21EX and three for IX. Conclusion: As a result of measuring and analyzing the daily output changes for two years by using CHECKMATE$^{TM}$, we could find that there is a significance between the output which we should obey during Q.A, and the measured value of absolute dose within the error tolerance of 2~3%. Thus, the use of CHECKMATE$^{TM}$ can be positively considered for more efficient and reliable daily output verification of linear accelerator. It can also be a good standard for other medical centers to understand the trends of linear accelerator and to refer to for the correction of each output.

  • PDF

The Improvement Plan on Unifying from Law and Regulations Related to Radiation (방사선관계법 개정 시 용어 적용에 관한 개선 방안)

  • Jeong, Dong-Kyong;Lee, Jong-Back;Park, Myeong-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.7-12
    • /
    • 2006
  • Purpose: This is for the purpose to help the bill related to technologists be systematic and unitary by carefully analyzing a legislation, an enforcement ordinance, and enforcement regulations in the connection with the radiological worker and the radiation workers from the law and regulations related to technologists. Materials and Methods: Concerning technologists, a legislation, an enforcement ordinance, and enforcement regulations for a sort of medical technician, regarding the radiological worker, the rules of diagnosis radiation equipment safety management, and concerning the radiation workers, atomic energy law, an enforcement ordinance and enforcement regulations were gathered, compared with one another, and analyzed. Results: Among technologists, in the case of working in the department of diagnosis radiation, the title 'Radiological Worker' is used by the Medical Service Law, and in the case of working in the department of radiation tumors or the one of nucleus medicine, the title 'Radiation Workers' is used by the Atomic Energy Law. Conclusion: Besides the technical term that is used by characteristic tasks, unification of the terms that can be used in common is necessary for sure. And when a legislation, an enforcement ordinance, enforcement regulations, and notification, things like that in the radiation field are amended, certainly they should be done by mutual agreement through negotiation between the organization related to radiation and the governmental organization.

  • PDF

Analysis on Longitudinal Dose according to Change of Field Width (선속 폭(Field Width) 변화에 따른 종축선량 분석)

  • Jung, Won-Seok;Back, Jong-Geal;Shin, Ryung-Mi;Oh, Byung-Cheon;Jo, Jun-Young;Kim, Gi-Chul;Choi, Tae-Gu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.109-117
    • /
    • 2011
  • Purpose: To analyze the accuracy of tumor volume dose following field width change, to check the difference of dose change by using self-made moving car, and to evaluate practical delivery tumor dose when tomotherapy in the treatment of organ influenced by breathing. Materials and Methods: By using self-made moving car, the difference of longitudinal movement (0.0 cm, 1.0 cm, 1.5 cm, 2.0 cm) was applied and compared calculated dose with measured dose according to change of field width (1.05 cm, 2.50 cm, 5.02 cm) and apprehended margin of error. Then done comparative analysis in degree of photosensitivity of DQA film measured by using Gafchromic EBT film. Dose profile and Gamma histogram were used to measure degree of photosensitivity of DQA film. Results: When field width were 1.05 cm, 2.50 cm, 5.02 cm, margin of error of dose delivery coefficient was -2.00%, -0.39%, -2.55%. In dose profile of Gafchromic EBT film's analysis, the movement of moving car had greater motion toward longitudinal direction and as field width was narrower, big error increased considerably at high dose part compared to calculated dose. The more field width was narrowed, gamma index had a large considerable influence of moving at gamma histogram. Conclusion: We could check the difference of longitudinal dose of moving organ. In order to small field width and minimize organ moving due to breathing, it is thought to be needed to develop breathing control unit and fixation tool.

  • PDF

Effect of the Dose Reduction Applied Low Dose for PET/CT According to CT Attenuation Correction Method (PET/CT 저선량 적용 시 CT 감쇠보정법에 따른 피폭선량 저감효과)

  • Jung, Seung Woo;Kim, Hong Kyun;Kwon, Jae Beom;Park, Sung Wook;Kim, Myeong Jun;Sin, Yeong Man;Kim, Yeong Heon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.127-133
    • /
    • 2014
  • Purpose: Low dose of PET/CT is important because of Patient's X-ray exposure. The aim of this study was to evaluate the effectiveness of low-dose PET/ CT image through the CTAC and QAC of patient study and phantom study. Materials and Methods: We used the discovery 710 PET/CT (GE). We used the NEMA IEC body phantom for evaluating the PET data corrected by ultra-low dose CT attenuation correction method and NU2-94 phantom for uniformity. After injection of 70.78 MBq and 22.2 MBq of 18 F-FDG were done to each of phantom, PET/CT scans were obtained. PET data were reconstructed by using of CTAC of which dose was for the diagnosis CT and Q. AC of which was only for attenuation correction. Quantitative analysis was performed by use of horizontal profile and vertical profile. Reference data which were corrected by CTAC were compared to PET data which was corrected by the ultra-low dose. The relative error was assessed. Patients with over weighted and normal weight also underwent a PET/CT scans according to low dose protocol and standard dose protocol. Relative error and signal to noise ratio of SUV were analyzed. Results: In the results of phantom test, phantom PET data were corrected by CTAC and Q.AC and they were compared each other. The relative error of Q.AC profile was been calculated, and it was shown in graph. In patient studies, PET data for overweight patient and normal weight patient were reconstructed by CTAC and Q.AC under routine dose and ultra-low dose. When routine dose was used, the relative error was small. When high dose was used, the result of overweight patient was effectively corrected by Q.AC. Conclusion: In phantom study, CTAC method with 80 kVp and 10 mA was resulted in bead hardening artifact. PET data corrected by ultra- low dose CTAC was not quantified, but those by the same dose were quantified properly. In patients' cases, PET data of over weighted patient could be quantified by Q.AC method. Its relative difference was not significant. Q.AC method was proper attenuation correction method when ultra-low dose was used. As a result, it is expected that Q.AC is a good method in order to reduce patient's exposure dose.

  • PDF

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.

고선량율 근접치료에서 기존의 필름 방법과 CT 재구성 방법의 정확성 비교 연구

  • 장지나;서태석;허순녕;윤세철;김회남;이형구;최보영
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.58-58
    • /
    • 2003
  • 목적 : 본 연구에서는 C-arm과 CT에 사용 가능한 자궁경부암용 팬톰을 개발하고 이를 이용하여 기존의 필름 방법에 기반한 위치 확인 방법과 CT 재구성 방법의 정확성을 비교 연구하고자 한다. 정확성이 검증된 후에는 두 방법의 장점을 이용하기 위해 CT로 재구성된 좌표를 필름의 좌표로 변환시켜 현재 사용되고 있는 필름에 기반한 근접 치료 계획 시행에 도움을 주고자 한다. 방법 : 자체 제작한 자궁경부암용 팬톰은 인체 등가 물질인 물과 아크릴을 사용하였고, 크게 localizer 부분과 팬톰 부분으로 구성되어 있다. 또한, 실제 자궁경부암 환자의 임상적인 구조를 모사하여 제작하였다. 자궁경부암 치료시 중요 장기인 방광과 직장을 구와 원기둥으로 설계하였고, 고선량율 applicator는 아크릴 판의 흠으로 고정시켜 제작하였기 때문에 CT 촬영시 applicator를 제거한 영상에서도 applicator의 구조가 정확하게 묘사될 수 있도록 제작하였다. 두 시스템에서 재구성된 좌표를 비교하기 위해 각각의 시스템에서의 얻은 재구성 좌표와 팬톰 자체의 localizer와 재구성 알고리즘을 바탕으로 개발된 프로그램을 이용하여 얻은 좌표로 두 재구성 좌표의 비교 연구를 수행하였다. 정확성이 검증되고 장기의 정보가 담긴 CT의 좌표는 자체 개발된 프로그램으로 2 차원의 필름 좌표로 변환되었다. 본 연구에 사용된 모든 프로그램은 ILD 5.5를 사용하여 개발되었다. 결과 : 두 시스템의 좌표 비교 결과 x, y 축은 차이가 2mm 이내로 비교적 정확한 실험 결과를 얻을 수 있었고, z 축의 경우 CT 슬라이드의 굵기에 따라 2mm-3mm 이내의 차이가 있음을 관찰할 수 있었다. z 축을 제외한 좌표의 차이는 획득한 영상에서 컴퓨터로 좌표를 옮기는 localizer 좌표 선택 과정에 발생했을 것으로 예상된다. 또한, 이 검증된 좌표와 개발된 프로그램을 이용하여 우리는 CT의 좌표를 2차원의 필름 좌표로 정확하게 변환할 수 있었다. 결론 : 이 연구로부터 기존의 C-arm 재구성 방법과 CT 재구성 방법의 비교를 통해 각 치료 기기의 신뢰성을 직접 확인할 수 있었으며, 비교를 통해 검증된 CT의 좌표를 필름 좌표로 변환시킴으로서, 각 시스템의 장점만을 결합한 효과적인 치료 계획을 세울 수 있는 가능성을 제시하였다. 또한 물과 아크릴을 사용한 비교적 간단하고 경제적인 방법으로 C-arm, CT 그리고 MRI에 모두 이용 가능한 팬톰을 제작하여 쉽고 정확하게 위치를 확인할 수 있었다. 더 나아가, 본 연구에서 제작된 자궁경부암 팬톰은 근접치료를 포함하여 관련 팬톰 개발에 도움을 줄 수 있을 것으로 예상된다.

  • PDF

Comparison of Practical Usefulness of Respirational Radiation Treatment Using Geant 4 Simulation Code (Geant 4 시뮬레이션 코드를 이용한 호흡 동조 방사선치료의 유용성 비교)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.637-643
    • /
    • 2019
  • To verify internal movements of the body, a DICOM file obtained from CT and a Geant4 code were used to simulate lung cancer patients. In addition, the method is applied to measure the movement of tumor when the movement of t he tumor is located inhale and exhale by creating a virtual tumor in the self-produced moving phantom, and to check the distribution of dose in the treatment plan and the accuracy of tumor in PTV for respiratory and lung cancer patients. It was confirmed that 97% or more respiratory control radiation therapy was effective even if the moving area was more than 3cm, in the 40% to 70% range. Dose distribution with respiratory radiation therapy applied to moving targets, measured by film in the actuation phantom, was shown to be within a 3mm margin of error for dose distribution containing 90%. It was confirmed that for actual patient breathing curves, the treatment time may be shorter than that due to the longer expiratory time.