• Title/Summary/Keyword: 선량 감소

Search Result 1,219, Processing Time 0.026 seconds

Skin Dose Distribution with Spoiler of 6 MV X-ray for Head and Neck Tumor (두경부암 치료를 위한 6 MV X-선 산란판의 제작과 산란분포 측정)

  • Lee Kyung-Ja;Chu Sung Sil
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.339-345
    • /
    • 1996
  • Purpose : This study was performed for adequate irradiating tumor area when 6 MV linear accerelator photon was used to treat the head and neck tumor. The skin surface dose and maximum build-up region was measured by using a spoiler which was located between skin surface and collimator. Methods : A spoiler was made of tissue equivalent material and the skin surface dose and maximum build-up region was measured varing with field size, thickness of spoiler and interval between skin and collimator. The results of skin surface dose and maximum build-up dose was represented as a build-up ratio and it was compared with dose distribution by using a bolus. Results : The skin surface dose was increased with appling spoiler and decreased by distance of the skin-spoiler separation. The maxium build-up region was 1.5 cm below the skin surface and it was markedly decreased near the skin surface. By using a 1.0-cm thickness spoiler, Dmax moved to 5, 10.2, 12.3 13.9 and 14.8 mm from the skin surface by separation of the spoiler from the skin 0, 5, 10, 15. 20 cm, respectively. Conclusion : The skin surface dose was increased and maximum build-up region was moved to the surface by using a spoiler. Therefore spoiler was useful in treating by high energy photon in the head and neck tumor.

  • PDF

THE EFFECTS OF X-RAY IRRADIATION ON THE GERMINATION AND GROWTH OF SEEDLING IN GinKgo biloba L.

  • You, Young-Soo;Kim, Yong-Kwan
    • Journal of Korean Society of Forest Science
    • /
    • v.8 no.1
    • /
    • pp.140-148
    • /
    • 1968
  • Ginkgo biloba L., which was distributed in Korea, was x-rayed with 100, 250, 500, 1000, 2000, 6000R. The results of responses about germination, morphological variations in seedling and early stage growth may be summarized as follows : 1. The germination percent was decreased with X-ray increasing dose from 500R except the slight stimulation of 100R. 2. The germination $LD_{50}$ seemed to be 765R. 3. The seedling height was depressed significantly but only slightly in 100R. 4. The loaf index was increased proportionally to high dose but T/R ratio was reduced apparently. 5. The dry or fresh weight decreased from 250R. It was highly significant except 100R. 6. Many morphological variations were indicated in plants.

  • PDF

Physicochemical Properties of Gamma-Irradiated Soybeans (감마선 조사된 대두의 이화학적 품질 특성)

  • Lee, Hyun-Ja;Kim, Jung-Ok;Yook, Hong-Sun;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.558-565
    • /
    • 1996
  • Some physicochemical properties of gamma-irradiated soybeans (0-20 kCy) were investigated. Proximate components, fatty acid compositions and minerals of the soybeans irradiated at 2.5 - 20 kGy shrived no difference from the nonirradiated control. Irradiation doses above 10 kGy and long term storage caused decrease in extractable phenols and phytate content, whereas increases in acid value and organic acid content. The total amino acids content of the soybeans irradiated up to 10 kGy was not changed as compared with the nonirradiated control. Sulfur-containing amino acids, however, were changed by 10 and 20 kGy irradiaton. Gamma irradiation and long term storage caused minor changes in the color attributes of soybeans. Hunter's 'L' (lightness) and 'b' (yellowness) values were decreased whereas 'a' (redness) value was increased with increasing dose levels and the elapse of the storage period.

  • PDF

Effect of Gamma Irradiation on Microbial Growth, Electron Donating Ability, and Lipid Oxidation of Marinated Beef Rib (Galbi) with Different Packaging Methods (포장방법에 따른 양념갈비의 저장 중 총균수, 전자공여능 및 지방산화의 감마선 조사효과)

  • 강호진;조철훈;이나영;김정옥;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.5
    • /
    • pp.888-893
    • /
    • 2004
  • The effect of irradiation and packaging methods (vacuum vs aerobic) on microbial growth, electron donating ability, and lipid oxidation in marinated beef rib (Galbi) was investigated. The total aerobic bacteria in Gazlbi reduced significantly with the increase of irradiation dose, and the effect was more significant in the Galbi with vacuum packaging, The pH showed a decreasing trend during storage and this change was more significant in the Galbi with aerobic packaging. Electron donating ability of Galbi was reduced by irradiation in aerobic packaging but no difference was found in vacuum packaging except 7 days. The 2-thiobarbituric acid reactive substances (TBARS) value of Galbi increased by irradiation in aerobic packaging during storage time, but that of vacuum packaging was maintained an initial value. Results indicated that irradiation coupled with vacuum packaging may enhance the microbial safety of Korean traditional meat products, Galbi, with minimum quality changes during storage.

Evaluation of entrance surface dose and image quality according to the installation of Bismuth shield in the case of endovascular treatment of cerebral aneurysm (뇌동맥류 코일 색전술 시 Bismuth 차폐체 설치에 따른 입사 표면 선량 평가 및 화질 평가)

  • Kim, Jae-Seok;Kim, Young-Kil;Choi, Jae-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.7
    • /
    • pp.779-785
    • /
    • 2019
  • By applying an ergonomically developed Bismuth shield to the endovascular treatment of cerebral aneurysm the radiation dose of the scalp and lens from the medical radiation exposure was reduced. The enrtance surface dose was analyzed by measuring the occipital parts, bilateral temporal parts, bilateral quadriceps, and nasal tip of the developed bismuth shield using a photostimulable fluorescence dosimeter before (Group A) before use (Group B). Signal to noise ratio (SNR) and contrast to noise ratio (CNR) analysis were used to evaluate the image quality when Bismuth shielding was used. The mean entrance surface dose of A group and B group was 26.92% lower than that of A group. The analysis of CNR and SNR was the same for both Roadmap and DSA. The use of Bismuth shielding is an alternative that can reduce the radiation impairment due to temporary hair loss and other stochastic effects that may occur after cerebrovascular intervention.

Discrimination Energy Range Analysis of Contrast Agents and Calcification using by VNC Application of DECT (DECT의 VNC 적용으로 조영제와 석회화의 식별 에너지 영역 분석)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.179-185
    • /
    • 2024
  • By applying the various energy spectrum imaging functions of DECT, To quantitatively distinguish between contrast agent and calcification, changes in image quality are analyzed by comparing CNR and SNR. We investigated the level of dose reduction during two scans and one VNC scan. As a result, contrast agent and calcification were best distinguished in the 70 keV area, CNR and SNR were excellent, and scan dose was reduced by about 26.5%. Therefore, by applying DECT, meaningful results were obtained that could visually and quantitatively distinguish between the intravascular contrast agent and the shade of calcification. If clinical research is conducted in the future considering the patient's age, gender, and body type, quantitative analysis of calcification will be possible even with intravascular contrast agent flowing in, which will have a significant effect in reducing the patient's scan dose and the burden of multiple scans.

Occupational Radiation Exposure to Hospital Workers: On the Effect of Hematological Change (병원 내 방사선 작업종사자의 만성적 방사선 피폭에 의한 혈액학적 성분 변화에 관한 연구)

  • Ryu, Jae-Kwang;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man;Dong, Kyung-Rae;Kim, Hyun-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.157-170
    • /
    • 2008
  • Purpose: This prospective study was conducted to reveal the haematological index change by low level radiation exposure in radiological environment our hospital workers. Materials and Method: We gathered the cumulative dose by Thermoluminenscent Dosimeters (TLD) over 9-yr period and examined hematological index counts change (RBC, Hb, Platelet, WBC, Monocyte, Lymphocyte, Neutrophilic, Basophilic, Eosinophilic) both occupational workers and controls. Of a total 370 occupational workers and 335 controls were compared. Results: This analysis has led to the following general observations 1) The average cumulative dose in male and female were $9.65{\pm}15.2\;mSv$, $4.82{\pm}5.55\;mSv$ respectively. 2) In both male and female, there were very low relationship between occupation period and cumulative dose (r< ${\pm}0.25$). 3) Occupation period was more increased, in male, WBC counts decreased and increased workers, RBC counts decreased workers were more than controls group (p<0.05). In female, WBC counts decreased and increased workers and W-eosino counts decreased workers were more than controls group (p<0.01). 4) Cumulative dose was more increased, in male, W-Lympho counts decreased workers and Platelet counts deceased workers were more than controls group (p<0.05). In female, W-lympho counts decreased workers and RBC counts decreased workers were more than controls group (p<0.05). Conclusions: We can find some kinds of blood index abnormal distribution in occupational radiation workers by comparing with controls. Occupational workers cannot avoid radiation exposure, in spite of the control it. Actually low level radiation adverse effect occurred not dose but probability. So workers must always try to reduce exposure by ourselves, furthermore as long as possible the government should provide rapidly that national system on radiation control for worker's health.

  • PDF

Effect of Carbon Couch Side Rail and Vac-lok In case of Lung RPO irradiation (Lung RPO 선량전달시, Carbon Couch Side Rail과 Vac-lok이 미치는 영향)

  • Kim, Seok Min;Gwak, Geun Tak;Lee, Seung Hun;Kim, Jung Soo;Kwon, Hyoung Cheol;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.27-34
    • /
    • 2018
  • Purpose : To evaluate the effect of carbon couch side rail and vacuum immobilization device in case of lung RPO irradiation. Materials and Methods : The 10, 20, 30 mm thickness of vac-lok's right side were obtained. To measure of doses, glass dosimeters were used and measured reference point is left lung center at the phantom. A, B, C, and D points are left, right, down, and up directions based on the center point. In the state of Side-Rail-Out, place the without vac-lok, with the thickness of 10, 20, and 30 mm vac-lok. After the glass dosimeters was inserted in center, A, B, C, and D points, 100 MU of 6 MV X-ray were irradiated to the referenced center point in the condition of $10{\times}10cm^2$ field size, SAD 100 cm, gantry angle 225, 300 MU/min dose rate. Five measurements were made for each point. In the state of Side-Rail-In, five measurement were made for each point under the same conditions. The average is measured on each of the five Side-Rail-Out and Side-Rail-In measurements. Results : In the presence of side rail, the dose reduction ratio was -11.8 %, -12.3 %, -4.1 %, -12.3 %, -7.3 % for each A, B, C, and D points. In the state of Side-Rail-Out, the dose reduction ratio for the using 10 mm thickness of vac-lok was -0.9 % than without vac-lok. The dose reduction ratio for the using 20 mm thickness of vac-lok was -2.0 %, for the using 30 mm thickness of the vac-lok was -3.0 % than without vac-lok. In the state of Side-Rail-In, the dose reduction ratio for the using 10 mm thickness of vac-lok was -1.0 % than without vac-lok. The dose reduction ratio for the using 20 mm vac-lok was -2.1 %, for the using 30 mm vac-lok was -3.0 % than without vac-lok. Based on the value of no vac-lok dose in the Side-Rail-In state, The dose reduction ratios for the using 10 mm, 20 mm and 30 mm thickness of vac-loks In the Side-Rail-Out that the center point were -12.7 %, -13.7 %, -14.2 % and -12.8 %, -13.8 %, -14.5 % respectively at point A. The dose reduction ratios for the same conditions to the B point were -4.9 %, -6.1 %, -7.1 % and -13.4 %, -14.4 %, -15.5 % respectively at point C. The dose reduction ratios for the same conditions to the D point were -8.4 %, -9.0 %, -10.4 % respectively. Conclusion : The attenuation was caused by presence of side rails and thickness of vac-lok. Pay attention to these attenuation factors, making it a more effective radiation therapy.

  • PDF

Basic Principles of CT Dose Index and Understanding of CT Parameter for Dose Reduction Technique (CT선량지표의 원리와 선량감소 방안에 관한 연구)

  • Kim, Jung-Su;Kwon, Soon-Mu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.51-61
    • /
    • 2015
  • Computed tomography(CT) using radiation have potential risks. All medical radiographic examinations should require the justification of medical imaging examinations and optimization of the image quality and radiation exposure. The CT examination was higher radiation dose then general radiography. Especially pediatric CT examinations need to great caution of radiation risk. Because of pediatric patient was more sensitive of radiation exposure. Therefore, physician should consider the knowledge of CT radiation exposure indicator information for reduce a needless radiation exposure. This article was aim to understanding of CT exposure indicator, size-specific dose estimates by American Association of Physicists in Medicine (AAPM) report 204, XR 25 and understanding of CT dose reduction technique.

Effects of Low Dose ${\gamma}$ Radiation on the Radiosensitivity of Soybean(Glycine max L.) Plant (저선량 ${\gamma}$선 조사가 대두 식물체의 방사선 감수성에 미치는 영향)

  • Kim, Jae-Sung;Chae, Sung-Ki;Back, Myung-Hwa;Kim, Dong-Hee
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.4
    • /
    • pp.324-327
    • /
    • 2000
  • Soybean (Glycine max L. cv. Hwangkeum) seeds were irradiated with the dose of $0{\sim}20$ Gy to investigate the effect of the low dose ${\gamma}-ray$ radiation on the early growth and resistance to subsequent high dose of radiation. Germination rate was not enhanced in the seeds irradiated with low dos ${\gamma}-ray$ but plant height and fresh weight increased in the low dose irradiation group. The optimal radiation dose for the growth increasing was 8 Gy in soybean plant. Growth inhibition of soybean plants by high dose radiation was noticeably reduced by pre-irradiation of low dose radiation, Resistance to subsequent high dose of radiation was effective in 8 Gy and 20 Gy irradiation group.

  • PDF