Abstract
By applying an ergonomically developed Bismuth shield to the endovascular treatment of cerebral aneurysm the radiation dose of the scalp and lens from the medical radiation exposure was reduced. The enrtance surface dose was analyzed by measuring the occipital parts, bilateral temporal parts, bilateral quadriceps, and nasal tip of the developed bismuth shield using a photostimulable fluorescence dosimeter before (Group A) before use (Group B). Signal to noise ratio (SNR) and contrast to noise ratio (CNR) analysis were used to evaluate the image quality when Bismuth shielding was used. The mean entrance surface dose of A group and B group was 26.92% lower than that of A group. The analysis of CNR and SNR was the same for both Roadmap and DSA. The use of Bismuth shielding is an alternative that can reduce the radiation impairment due to temporary hair loss and other stochastic effects that may occur after cerebrovascular intervention.
Keywords
Cerebrovascular intervention; Bismuth shield; Radiation exposure; Radiation protection;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 J. S. Kim, J. H. Kim, and T. I. Kim, "Usefulness of Lens and Thyroid Screening Device for Hepatic Artery Embolization," Korean Society of Cardio-Vascular Interventional Technology, vol. 19, no. 1, pp. 157-163, 2016.
2 C. M. Quinn, M. S. Cosette, P. A. Michael, B. K. Thomas, and G. N. Isabel, "Radiation protection for the fluoroscopy operator and staff " American roentgen ray society, vol. 207, pp. 745-754, 2016.   DOI
3 E. Aytugar, T. E. Kose, B. Gumru, T. B. Aytugar, D. Yasar, E. Cene, and A. Mihmanli, "Are Bismuth Shields Useful in Dentomaxillofacial Radiology Practicefor the Protection of Eyes and Thyroid Glands from Ionizing Radiation?" Iran Journal of radiology, vol. 15, no. 3, pp. 1-6, 2017.
4 S. Balter, and D. L. Miller, "Patient skin reactions from interventional fluoroscopy procedures," American Journal of Roentgenology, vol. 202, no. 4, pp. 335-342, 2014.   DOI
5 J. H. Wang and S. J. Kang, "Radiation protection guidelines for patient dose reduction in interventional procedures," Radiation Safety Management Series, Technical Report, vol. 36, Seoul, pp. 18-24, 2014.
6 D. J. McLaughlin, and R. B. Mooney, "Dose reduction to radiosensitive tissues in CT. do commercially available shields meet the users' needs?," Clinical Radiology Northern Ireland, UK, vol. 59, Issue 5, pp. 446-450, 2004.
7 C. P. Shortt, N. F. Fanning, L. Malone, J. Thornton, P. Brennan, and M. J. Lee, "Thyroid dose during neurointerventional procedure: does lead shielding reduces the dose?," Cardiovascular & Interventional Radiology, vol. 30, no. 5, pp. 922-927, 2007.   DOI
8 J. S. Kim, Y. K. Kim, and J. H. Choi, "Effects of self-made bismuth shield installation on entrance surface dose reduction during endovascular treatment of cerebral aneurysms," Journal of Korean Society of Radiology, vol. 13, no. 2, pp. 175-183, 2019.   DOI
9 S. C. Han, and S. C. Kwon, "Radiation dose reduction to the critical organ with bismuth shielding during endovascular coil embolization for cerebral aneurysm," Radiation Protection Dosimetry, Published by Oxford University Press, vol. 156, no. 3, pp. 364-371, 2013.   DOI