• Title/Summary/Keyword: 선량계산

Search Result 721, Processing Time 0.037 seconds

Neutron Dose Measurements Using TLDs in a 252Cf Neutron Field (252Cf 중성자장에서 열형광선량계(TLD)를 이용한 중성자 방사선량 측정)

  • Chang, Insu;Kim, Sang In;Lee, Jung Il;Kim, Jang Lyurl;Kim, Bong Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.37-43
    • /
    • 2013
  • In case of neutron dose measurement using TLDs (thermo-luminescence dosimeters), because the neutron energy dependence of the TLD is very high, the calibration of the energy response according to the characteristics of the neutron spectrum of workplace is required. In the present study, the ambient dose equivalent rates inside and around the Long-Counter (neutron detector) with narrow and complex inside in the neutron field of $^{252}Cf$ were evaluated. The calibration factors to account for the neutron energy dependence of TLDs were established for both the bare and $D_2O$ modulated $^{252}Cf$ neutron beams, respectively. The values of the TLD's measurement were compared with the computational results of the MCNPX (Monte Carlo N-Particles transport code). When using the two calibration factors of the TLD than a single calibration factor, the measured and the calculated values at the point of verification outside and inside the Long-Counter were in more good agreement. This results show that TLD should be calibrated in the reference neutron field similar to workplace situation.

Development and Evaluation of Quality Assurance Worksheet for the Radiation Treatment Planning System (방사선치료계획 시스템의 정도관리 절차서 개발 및 유용성 평가)

  • Cho Kwang Hwan;Choi Jinho;Shin Dong Oh;Kwon Soo Il;Choi Doo Ho;Kim Yong Ho;Lee Sang Hoon
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.186-191
    • /
    • 2004
  • The periodic Quality Assurance (QA) of each radiation treatment related equipments is important one, but quality assurance of the radiation treatment planning system (RTPS) is still not sufficient rather than other related equipments in clinics. Therefore, this study will present and test the periodic QA program to compare, evaluation the efficiency of the treatment planning systems. This QA program is divided to terms for the input, output devices and dosimetric data and categorized to the weekly, monthly, yearly and non-periodically with respect to the job time, frequency of error, priority of importance. CT images of the water equivalent solid phantom with a heterogeneity condition are input into the RTPS to proceed the test. The actual measurement data are obtained by using the ion chamber for the 6 MV, 10 MV photon beam, then compared a calculation data with a measurement data to evaluate the accuracy of the RTPS. Most of results for the accuracy of geometry and beam data are agreed within the error criteria which is recommended from the various advanced country and related societies. This result can be applied to the periodic QA program to improve the treatment outcome as a proper model in Korea and used to evaluate the accuracy of the RTPS.

  • PDF

Effect of Low Magnetic Field on Dose Distribution in the Partial-Breast Irradiation (부분유방 방사선조사 시 저자기장이 선량분포에 미치는 영향)

  • Kim, Jung-in;Park, So-Yeon;Lee, Yang Hoon;Shin, Kyung Hwan;Wu, Hong-Gyun;Park, Jong Min
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.208-214
    • /
    • 2015
  • The aim of this study is to investigate the effect of low magnetic field on dose distribution in the partial-breast irradiation (PBI). Eleven patients with an invasive early-stage breast carcinoma were treated prospectively with PBI using 38.5 Gy delivered in 10 fractions using the $ViewRay^{(R)}$ system. For each of the treatment plans, dose distribution was calculated with magnetic field and without magnetic field, and the difference between dose and volume for each organ were evaluated. For planning target volume (PTV), the analysis included the point minimum ($D_{min}$), maximum, mean dose ($D_{mean}$) and volume receiving at least 90% ($V_{90%}$), 95% ($V_{95%}$) and 107% ($V_{107%}$) of the prescribed dose, respectively. For organs at risk (OARs), the ipsilateral lung was analyzed with $D_{mean}$ and the volume receiving 20 Gy ($V_{20\;Gy}$), and the contralateral lung was analyzed with only $D_{mean}$. The heart was analyzed with $D_{mean}$, $D_{max}$, and $V_{20\;Gy}$, and both inner and outer shells were analyzed with the point $D_{min}$, $D_{max}$ and $D_{mean}$, respectively. For PTV, the effect of low magnetic field on dose distribution showed a difference of up to 2% for volume change and 4 Gy for dose. In OARs analysis, the significant effect of the magnetic field was not observed. Despite small deviation values, the average difference of mean dose values showed significant difference (p<0.001), but there was no difference of point minimum dose values in both sehll structures. The largest deviation for the average difference of $D_{max}$ in the outer shell structure was $5.0{\pm}10.5Gy$ (p=0.148). The effect of low magnetic field of 0.35 T on dose deposition by a Co-60 beam was not significantly observed within the body for PBI IMRT plans. The dose deposition was only appreciable outside the body, where a dose build-up due to contaminated electrons generated in the treatment head and scattered electrons formed near the body surface.

External Exposure Due to Natural Radionuclides in Building Materials in Korean Dwellings (건축자재내 포함된 천연방사성핵종에 의한 실내 공간의 방사선량 평가)

  • Cho, Yoon Hae;Kim, Chang Jong;Yun, Ju Yong;Cho, Dae-Hyung;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.181-190
    • /
    • 2012
  • Naturally occurring radioactive materials (NORM) in building materials are main sources of external radiation exposure to the general public. The objective of this study was to assess external radiation dose in Korean dwellings due to NORM in concrete walls. Reference room model for dose assessment was made by analyzing room structure and housing scale of Korean dwellings. In addition, dose assessments were made for varying room sizes. Absorbed doses to air and effective dose rates were calculated using radiation transport code MCNPX. Assuming a reference room of $3{\times}4{\times}2.8m^3$, absorbed dose rates in air were 0.80, 0.97, 0.08 nGy $h^{-1}$ per Bq $kg^{-1}$ for uranium series, thorium series, and $^{40}K$, respectively. Effective dose rates were 0.57, 0.69, 0.058 nSv $h^{-1}$ per Bq $kg^{-1}$, respectively. Radiation dose resulting from concrete of ceiling and floor increased with room area while radiation dose from concrete of walls decreased with room area. Therefore, total radiation doses were almost the same for the varying room area from 5 to $30m^2$. Effective dose in Korean dwellings was calculated based on measurement data of NORM concentration in concrete and occupancy fraction of Korean population by location. Annual effective dose was 0.59 mSv assuming that indoor occupancy fraction was 0.89 and concentrations of uranium series, thorium series and $^{40}K$ were 26, 39, 596 Bq $kg^{-1}$, respectively. Finally, annual effective dose in Korean dwellings can be calculated by the following equation: Effective dose=indoor occupancy fraction${\times}8760\;h\;y^{-1}{\times}(0.57C_U+0.69C_{Th}+0.058C_K)$.

Application of an imaging plate to relative dosimetry of clinical x-ray beams (Imaging Plate를 이용한 의료용 광자선의 선량측정)

  • 임상욱;여인환;김대용;안용찬;허승재;윤병수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2000
  • The IP(imaging plate) has been widely used to measure the two-dimensional distribution of incident radiation since it has a high sensitivity, reusability, a wide dynamic range, a high position resolution. Particularly, the easiness of acquiring digitized image using IP poses a strong merit because recent trend of data handling prefers image digitization. In order to test its usefulness in photon beam dosimetry, we measured the off-axis ratio(OAR) on portal planes and percent depth dose(PDD) within a phantom using IP, and compared the results with the data based on EGS4 Monte Carlo particle transport code, ion-chambers, conventional films. For the measurement, we used 6 MV X-rays, various field sizes. As a result, IP showed significant deviation from ion-chamber measurement: a significant overresponse, 100% greater than that of ion-chamber measurement at deep part of the phantom. Filtration of low-energy scattered photons at deep part of the phantom using 0.5 mm thick lead sheets did improve the result, only to the unacceptable extent. However, portal dose measurement showed possibilities of If as a dosimeter by showing errors less than 5%, as compared with film measurement.

  • PDF

Study on Development of Patient Effective Dose Calculation Program of Nuclear Medicine Examination (핵의학검사의 환자 유효선량 계산 프로그램 제작에 관한 연구)

  • Seon, Jong-Ryul;Gil, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.657-665
    • /
    • 2017
  • The aim of this study was to develop and distribute a dedicated program that can easily calculate the effective dose of a patient undergoing nuclear medicine examinations, and assist in the study of dose of nuclear medicine examinations and information disclosure. The program produced a database of the effective dose per unit activity administered (mSv/MBq) of the radiopharmaceuticals listed in ICRP 80, 106 Report and the fourth addendum, was designed through Microsoft Visual Basic (In Excel) to take the effect of 5 different (Area, Clark, Solomon(=Fried), Webster, Young) of pediatric dose calculation methods and 7 different body surface area calculation methods. The program calculates the effective dose (mSv) when the age, radionuclide, substance, and amount injected in the human body is inputted. In pediatric cases, when the age is entered, the pediatric method is activated and the pediatric method to be applied can be selected. When the BSA (Body Surface Area) formula is selected in the pediatric calculation method, a selection window for selecting the body surface area calculation method is activated. When the adult dose is input, the infant dose and the effective dose (mSv) are calculated automatically. The patient effective dose calculation program of the nuclear medicine examinations produced in this study is meaningful as a tool for calculating the internal exposure dose of the human body that is most likely to be obtained in nuclear medicine examinations, even though it is not the actual measurement dose. In the future, to increase the utilization of the program, it will be produced as an application that can be used in mobile devices, so that the public can access it easily.

A Study on Photon Dose Calculation in 6 MV Linear Accelerator Based on Monte Carlo Method (몬테카를로 방법에 의한 6 MV 선형가속기의 광자 흡수선량 분포 평가에 관한 연구)

  • Kang, Sang-Koo;Ahn, Sung-Hwan;Kim, Chong-Yeal
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.43-50
    • /
    • 2011
  • In this study we modeled the varian 2100C/D linear accelerator head and multi-leaf collimator by simulation with the GEANT4 Monte Carlo toolkit. Then central axis percentage depth dose profiles and lateral dose profiles within homogeneous water phantom($50{\times}50{\times}50\;cm^3$) were evaluated with 6 MV photon beam. The simulations were performed in two stages. In the first stage, photon energy spectrum at the target were computed were computed. Then spectra data was directly irradiated in the water phantom using sampling techniques. The simulation data were compared with experimental data to evaluate the accuracy of the model. Results showed that two data were matched within 2% error boundary. The proposed method will be applied for simulation of dose calculation and dose distribution study.

A Study on Dose Distribution around Fletcher-Suit Colpostat Containing Cs-137 Source by a Computer (컴퓨터 의한 Fletcher-Suit Colpostat 주변의 Cs-137의 선량분포에 관한 연구)

  • Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.305-311
    • /
    • 1989
  • Fletcher-Suit colpostat has an internal structure to reduce dose to bladder and rectum. Some programs were developed to calculate dose at any point in water in three dimension around the colpostat containing Cs-137 tube, to find the shielding effect to dose by the internal structure, and to draw isodose curves and iso-shielding effect curves. Computer was an IBM compatible AT with EGA card and language was MS-Basic V6.0, Material, shape and geometry of the strucure, tube and colpostat were considered in algorithm for calculation of dose. Dose rates per unit mg. Ra. eq. in water calculated by a program were stored in auxiliary memory devices and retrieved in another programs. Isodose curves on medial side shrinked. Dose distribution was not symmetric about a transverse axis bisecting the colpostat. Reduction of dose was more excessive on top side than on bottom. Iso-shielding effect curve showed that the shielding effect was higher on top side than on bottom, and that there was shielding effect over almost all area of medial side. Such results were related to both shifted position of tube in the colpostat and asymmetric distribution of active source in the tube. Maximum of shielding effect was $49\%$ on top side and $44\%$ on bottom side. The direction of iso-shielding effect curve was generally radial from the center of active source. In treatment planning using Fletcher-Suit colpostat, the internal structure should be considered to find precise doses to bladder and rectum, etc.

  • PDF

Influence of Total Laryngectomy on Spinal Cord Dose in Advanced Laryngeal Cancers (진행된 후두암 환자에서 후두전절제술에 의한 척수선량 변화)

  • Kim, Jae-Cheol;Kim, Sung-Hwan;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.167-173
    • /
    • 1996
  • Purpose : This analysis was to evaluate the radiation dose around a tracheostoma and spinal cord in the case of advanced laryngeal cancers in which a total laryngectomy was done before radiotherapy. Materials and Methods : The radiation dose around a tracheostoma and spinal cord was measured by thermoluminescence and film dosimetry in the phantom, Radiotherapy treatment planning was done in 12 cases of advanced laryngeal cancer and compared with the measured dose in the phantom. Results : Mean spinal cord doses in the phantom by thermoluminescence dosimetry were $86.4\%$ (with a tracheostoma), $80.1\%$ (without a tracheostoma), and the difference was $6.3\%$. Mean spinal cord doses in the phantom by film dosimetry were $84.7\%$ (with a tracheostoma), $79.0\%$ (without a tracheostoma). and the difference were $5.7\%$. Calculated spinal cord doses in the phantom were $84.0\%$ (with a tracheostoma), $78.0\%$ (without a tracheostoma), and the difference was $6.0\%$. Mean calculated spinal cord doses in 12 patients were $83.1\%$ (with a tracheostoma), $76.9\%$ (without a tracheostoma). and the difference was $6.2\%$. Measured dose of lateral and posterior wall of the tracheostoma by film was low (depth of maximum dose = 12 mm). Conclusion : In the treatment planning of the advanced laryngeal cancers, the radiation dose of the tracheostoma and spinal cord should be evaluated and be followed by an appropriate management such as a bouls or a brachytherapy boost if the dose around the tracheostoma is low.

  • PDF

Consideration of Surface Dose and Depth of Maximum Dose Using Various Detectors for High Energy X-rays (측정기에 따른 고에너지 X-선의 표면 선량 및 최대 선량 지점 고찰)

  • Lee Yong Ha;Park Kyung Ran;Lee Jong Young;Lee Ik Jae;Park Young Woo;Lee Kang Kyoo
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.322-329
    • /
    • 2003
  • Purpose: It is difficult to exactly determine the surface dose and the dose distribution In buildup region of high energy X-rays by using the conventional ion chamber. The aim of this study Is to evaluate the accuracy of widely used dosimetry systems to measure the surface dose and the depth of maximum dose (d$_{max}$). Materials and Methods: We measured the percent depth dose (PDD) from the surface to the d$_{max}$ in either a water phantom or in a solid water phantom using TLD-100 chips, thimble type ion chamber, diode detector, diamond detector and Markus parallel plate ion chamber for 6 MV and 15 MV X-rays, 10$\times$10 cm$^{2}$, at SSD=100cm. We analysed the surface dose and the d$_{max}$. In order to verify the accuracy of the TLD data, we executed the Monte Carlo simulation for 5 MV X-ray beams. Results: The surface doses In 6 MV and IS MV X-rays were 29.31% and 23.36% ior Markus parallel plate ion chamber, 37.17$\%$ and 24.01$\%$ for TLD, 34.87$\%$ and 24.06$\%$ for diamond detector, 38.13$\%$ and 27.8$\%$ for diode detector, and 47.92$\%$ and 35.01$\%$ for thimble type ion chamber, respectively. in Monte Carlo simulation for 6 MV X-rays, the surface dose was 36.22$\%$, which Is similar to the 37.17$\%$ of the TLD measurement data. The d$_{max}$ In 6 WV and 15 MV X-rays was 14$\~$16 mm and 27$\~$29 mm, respectively. There was no significant difference in the d$_{max}$ among the detectors. Conclusion: There was a remarkable difference in the surface dose among the detectors. The Markus parallel plate chamber showed the most accurate result. The surface dose of the thimble ion chamber was 10$\%$ higher than that of other detectors. We suggest that the correction should be made when the surface dose of the thimble ion chamber Is used for the treatment planning ion the supeficial tumors. All the detectors used In our study showed no difference in the d$_{max}$.