• 제목/요약/키워드: 석면 농도

검색결과 42건 처리시간 0.034초

슬레이트 지붕의 설치년도와 면적에 따른 공기 및 유출 빗물 중의 석면 농도 (Asbestos Concentrations in Ambient Air and Drained Rainwater from Slate Roofing by Construction Year and Roof Area)

  • 장봉기;류제영;탁현욱;송수진;이종화;이강호;최재호
    • 한국산업보건학회지
    • /
    • 제23권3호
    • /
    • pp.196-204
    • /
    • 2013
  • Objectives: The purpose of this study is to analyze the number and influence factors of asbestos fibers in the air of farmhouses with asbestos cement slate roofing, as well as in rainwater per unit area of the asbestos cement slate roofing. Methods: At a distance of 1 m from the end of asbestos cement slate roofing in 20 farmhouses, the asbestos fiber in the air was collected three times on a clear day downwind from the prevailing wind. Rainwater falling from the slate roofing was collected four times with a 1.05-m rainwater pipe on a rainy day at the 20 farmhouses, filtered with a MCE filter, and analyzed with a phase contrast microscope. Results: The geometric mean of the number of asbestos fibers in the air of farmhouses with slate roofing was 0.11 fiber/L, and no samples exceeded the recommended standard of 10 fiber/L. As a result of multiple regression analysis, a factor which gave a significant influence to the asbestos fiber content in the air was the gross area of slate roofing at the target farmhouses. The number of asbestos fibers included in rainwater collected per 1 m2 of slate roofing was 1,753 fiber/$L{\cdot}m2$. As a result of multiple regression analysis, the number of asbestos fibers contained in rainwater per 1 m2 of slate showed a significantly higher tendency as the year of slate roofing installation at the target farmhouses receded. Conclusions: It was confirmed for the first time in Korea that asbestos from asbestos cement slate roofing scatters into the air.

석면함유 건축물의 관찰조사를 통한 실내공기 중 섬유 농도 변화 요인 추정 (Estimation of Factors Influencing Airborne Fiber Concentrations through an Observation Survey of Asbestos-containing Materials in Buildings)

  • 이승철;김부욱;이광용;신용철
    • 한국산업보건학회지
    • /
    • 제25권2호
    • /
    • pp.174-183
    • /
    • 2015
  • Objectives: The objective of this study is the estimation of factors influencing airborne fiber concentrations by means of an observation survey of asbestos-containing materials in buildings. Methods: Forty-five samples were collected from four commercial buildings by NIOSH Method 7400 and classified according to current condition, potential activity, construction year, and operations and maintenance(O&M). Results: Airborne fiber concentrations by current condition(classified as good, fair and poor) were significantly different(p<0.05). Concentrations by potential activity were significantly different among groups(p<0.05), and those from the low activity group were higher than those from the middle activity group. Based on construction year, airborne fiber concentrations from the decade of the 1990's were higher than those from the 1960's. When O&M status was considered, airborne fiber concentrations from 1960's buildings were lower than those buildings not operated and maintained(p<0.01), because dust generation was influenced by O&M status. It was found that airborne fiber concentrations were related to current condition and potential activity via regression analysis, but the coefficient of determination was low. Also, correlation analysis showed that the higher the potential activity, the more current condition is worsened, but the relationship was not significant(r=-0.455, p>0.05). Conclusions: Airborne fiber concentrations in asbestos-containing buildings had weak relationships with current condition and potential activity.

국내 공기 중 섬유상 분진 숙련도 시험용 표준시료 제조 및 평가 (Preparation and assessment of airborne fibrous reference sample for a proficiency test)

  • 임호주;유재혁;최성호;최아름;정현성;류정민;김현욱;장성기
    • 분석과학
    • /
    • 제22권5호
    • /
    • pp.369-375
    • /
    • 2009
  • 저농도 섬유상 분진 표준시료를 제조하여 균질도와 정확성을 조사하고, 모의 숙련도 시험을 통해 최적의 숙련도 시험 방안을 평가하였다. 분석 결과 표준시료 농도와 석면밀도의 상관성이 0.9863~0.9968으로 매우 높게 나타났고, 표준시료를 이용한 모의 숙련도 시험을 통해서, 국내에서의 숙련도 시험 결과 평가 기준은 표준시료 분석결과의 Z값이 ${\mid}Z{\mid}{\leq}2$를 만족하는 것이 타당한 것으로 나타났다.

지상과 지하역사의 실내공기질 특성과 외기영향 평가 (Characteristics of indoor air quality in the overground and underground railway stations)

  • 남궁형규;송지한;김수연;김희만;권순박
    • 한국산학기술학회논문지
    • /
    • 제17권5호
    • /
    • pp.17-25
    • /
    • 2016
  • 본 연구에서는 지하역사와 지상역사에서의 실내공기질을 측정하고, 외부 공기에 의한 영향 정도를 확인하고자 하였다. 측정된 물질은 '실내공기질 관리법'상에서 유지기준과 권고기준으로 지정된 항목 중, 농도가 검출되지 않은 석면을 제외한 미세먼지($PM_{10}$), 이산화탄소($CO_2$), 일산화탄소(CO), 이산화질소($NO_2$), 폼알데하이드(HCHO), 오존($O_3$), 총부유세균(TAB), 총휘발성유기화합물(TVOC), 라돈 등 9종이다. 또한 미세먼지, 이산화질소, 오존 등 세 가지 물질은 I/O ratio를 통해 외기에의한 영향을 확인하였다. 공기질 측정결과 지상역사에 비해 지하역사에서 미세먼지, 폼알데하이드, 총휘발성유기화합물, 이산화질소, 라돈 등이 높은 농도로 검출되었으며, 이는 지하역사 내부에 그 오염물질의 발생요소가 존재하기 때문으로 판단된다. 오존 농도는 지상역사에서 지하역사보다 높은 농도로 검출되었으며, 특히 외부로 노출되어있는 지상역사 승강장에서 높은 농도를 보임으로써 외기 유입에 의한 영향이 있는 것으로 확인되었다. 따라서, 외기에 의한 영향을 받는 오염물질은 역사의 기계환기시 제거 과정을 거쳐 오염물질의 실내유입을 차단하고, 지하역사에서 기인한 미세먼지 등의 물질들은 실내에서 그 발생원에 따른 별도의 처리가 필요할 것으로 판단된다.

석면방직업 근로자의 석면노출 실태와 과거농도 추정에 관한 연구 (A Study on Exposure Among Asbestos Textile Workers and Estimation of their Historical Exposures)

  • 박정임;윤충식;백남원
    • 한국산업보건학회지
    • /
    • 제5권1호
    • /
    • pp.16-39
    • /
    • 1995
  • From July 8 to September 2 1994, asbestos exposure level among asbestos textile workers was surveyed. Six plants out of plants in Korea were selected for this study. In addition to the exposure level, the relationship between the level of exposure and some factors affecting exposure were studied. Also, using historical data of asbestos concentrations in asbestos textile plants plus current data, trend of asbestos exposure level could be introduced. Historical exposure level was estimated on the basis of these data. The main results of this study are follows. 1. Average concentration of all six plants surveyed was 1.54 f/cc, and range of those concentrations was 0.03 - 11.58 f/cc. The minimum average concentration was 0.32 f/cc and the maximum was 8.04 f/cc which is four times higher than the Korean standard. A wide difference of exposure level among the workers of different plants was observed. In three plants, the half of all the plants surveyed, their average concentrations exceeded the Korean standard, and those in all the plants exceeded the ACGIH TLV. 2. Among total 56 samples, 22 samples(39%) were in excess of the Korean standard, and 53 samples(95%) were above the ACGIH TLV. Among 32 personal samples, 15 samples(47%) exceeded the Korean standard, and 30 samples(94%) exceeded the ACGIH TLV. Among 24 area samples excluding a few samples collected in office area, seven samples exceeded the Korean standard, and 23 samples( 96%) exceeded the ACGIH TLV. 3. Distributions of concentrations were observed by processes. In weaving, the highest, average concentration was 4.29 f/cc, and range was 2.61 - 11.58 f/cc. In spinning, average concentration was 2.22 f/cc, and range was 0.41 - 8.93 f/cc. In carding, average concentration was 1.98 f/cc, and range was 0.23 - 10.93 f/cc, In twisting, average concentration was 1.65 f/cc, and range was 0.21 - 9.83 f/cc. In mixing, the lowest, average concentration was 0.48 f/cc, and range was 0.22 - 1.20 f/cc. 4. All the samples from basic processes of asbestos textile plants were above the ACGIH TLV. Nineteen samples(45%) out of all these 42 samples exceeded Korean standard. Fourteen samples(58%) of total 24 personal samples, and five samples(28%) of total 18 area samples exceeded the Korean standard. Considering processes, all the samples in weaving process exceeded the Korean standard and 50 did 54% of those in spinning, 40% in carding, and 27% in twisting. 5. Trend of decreasing asbestos concentrations in asbestos textile plants was observed by time. 6. Asbestos concentrations in asbestos textile plant in 1975 were estimated to be 11.0 - 92.4 f/cc.

  • PDF

초염기성 사문암 토양 중 세균군집의 계통학적 특성 (Phylogenetic Characteristics of Bacterial Populations Found in Serpentinite Soil)

  • 이종화;;황경숙
    • 미생물학회지
    • /
    • 제39권1호
    • /
    • pp.16-20
    • /
    • 2003
  • 충남 홍성군 광천 사문암 토양지역의 석면폐광석(KS1)과 인근 토양(KG, KS2)은 pH8.5-9.2를 나타내어 초염기성 토양임이 확인되었다. KSI과 KS2 토양으로부터 통상농도의 alkaline 배지(AL)와 AL 배지를 $10^{-2}$로 희석한 DAL배지를 사용하여 평판법으로 세균수를 측정한 결과 AL 배지에서보다 DAL배지에서 10-100배 이상 높은 계수치를 나타내었다. 초염기성 사문암 토양으로부터 분리된 75균주에대해 통상농도의 AL 배지에서의 중식 유무를 확인한 결과, 통상농도의 AL배지에서 증식 가능한 [AL세균군]과 AL배지에서는 증식이 저해되고 DAL 배지에서만 증식 가능한 [DAL세균군으로 크게 나누었다. DAL세균(42균주)은 $10^{-3}$ AL 배지(약 6mg C/L)에서도 증식 가능한 저영양성세균(oligotrophic bacteria)으로 사문암 토양 중 50% 이상 분포해 있음이 확인되었다. 분리된 75 균주의 16S rDNA 염기서열을 결정하여 계통해석한 결과 proteobacteria $\alpha$-subdivision (3균주), $\beta$-subdivision (7균주), $\gamma$-subdivision (2균주), high G+C gram-positive bacteria (19균주)와 low G+C gram-positive bacteria (14 strains)의 계통군을 나타내었다. 이들 세균중 AL세균군(34균주)은 high G+C gram positive bacteria 에 속하는 streptomyces과 low G+C gram positive bacteria에 속하는 Bacillus로 구성되었다. 한편, DAL세균군(42균주)은 high G+C 및 low G+C gram positive 계통군 이외에도 proteobacteria -subdivision에 속하는 Afipia와 Ralstonia, proteobacteria -subdivision에 속하는 Variovorax, proteobacteria $\beta$-subdivision에 속하는Pseudomonas로 구성되어 계통학적으로 다양한 세균임이 확인되었다.

위상차 현미경법을 이용한 공기중 석면농도 분석에서의 정도관리 (Quality Control of Asbestos Fiber Counting for Airborne Samples Using Phase Contrast Microscopy)

  • 강보영;신용철;백남원
    • 한국산업보건학회지
    • /
    • 제1권2호
    • /
    • pp.221-237
    • /
    • 1991
  • This study was conducted to evaluate the accuracy and the precision of asbestos counting data produced by the Division of Industrial Health, School of Public Health, Seoul National Universitys (SNU). The study was performed from July 18 to October 4, 1991, and the results are summarized as follows. 1. Intracounter Relative Standard Deviations (Sr) in the category of 5-50.5 fibers as total fibers counted ranged from 0.27 to 0.37, which were greater than 0.10-0.17 which were reported by the NIOSH. The reasons are supposed to be as follows. First, inexperience of counters in asbestos fiber counting was considered to be a main reason. Second, poor quality of samples due to sampling and mounting error increased variation of counting. Third, fiber density of many samples were less than $100fibers/mm^2$. But Intracounter Relative Standard Deviations (Sr) in samples with >50.5 fibers ranged from 0.l6 to 0.20, approaching the value 01 NIOSH. 2. Intralaboratory Relative Standard Deviations (Sr) in categories of 5-20.5, >20.5-50.5 and >50.5 fibers were 0.54, 0.37 and 0.26, respectively. Intralaboratory Sr in samples with fiber density greater than $100fibers/mm^2$ was 0.26. This was similar to the values reported by other foreign experienced laboratories. 3. Comparing results of three counters, Counter C, a beginner, overestimated asbestos fiber concentrations. 4. Since our SNU laboratory has participated in two quality control programs, IOMA-F.R.I.C.A., U.K. and NIOSH PAT Program, U.S.A., this laboratory has been evaluated as " Rating 1" and "Proficient" laboratory, by IOM and NIOSH, respectively.

  • PDF

경남지역의 실내외 공기 중 총섬유 입자의 농도특성 및 석면 입자의 확인 (Concentration Characteristics of Indoor and Outdoor Airborne Total Fiber Particles and Identification of Asbestos in Gyeongnam Provinces)

  • 박희은;박정호;김형갑
    • 한국산업보건학회지
    • /
    • 제22권2호
    • /
    • pp.119-127
    • /
    • 2012
  • Objectives: The aim of this study is to identify concentration characteristics of indoor and outdoor airborne total fiber particles and asbestos in Gyeongnam Provinces. Methods: This study investigated concentration characteristics of indoor fiber particles from 748 schools and 38 public facilities as well as outdoor particles from 11 sites through PCM (phase contrast microscope). SEM/EDX (scanning electron microscope/energy dispersive using X-ray analysis) was used to obtain physicochemical information of asbestos fiber particles. The study identified asbestos rate in the 15 samples from indoor and outdoor airborne total fiber particles. Results: 1. The average indoor airborne concentrations of total fiber particles were $0.0011{\pm}0007$ f/cc in schools and $0.0015{\pm}0007$ f/cc in public facilities by PCM. Over 90% of the fiber particles were identified as single fibers. 2. The average outdoor airborne concentrations of total fiber particles were $0.0007{\pm}0002$ f/cc, and they were lower than those of indoor airborne concentrations. 3. The results showed that the form of asbestiform was diverse as skein of thread like form and long needle, which was relatively narrower than that of glass fiber and rock wool. 4. The results of SEM/EDX analysis of 15 areas where total fiber particle was relatively high showed that the form was rather similar to that of asbestos, but chemical composition was proven to be non-asbestos. Conclusions: The concentration of indoor and outdoor airborne total fiber particles of Gyeongnam Provinces satisfied the IAQ (Indoor air quality) level of 0.01 f/cc and asbestos was not found in most of the samples by SEM/EDX.

서울시내 석면함유 건축물 철거 현장 등에서의 효과적인 공기 중 석면농도 측정을 위한 연구 (A Study on the Efficient Measurement of Airborne Asbestos Concentrations at Demolition Sites of Asbestos Containing Buildings, etc. in Seoul)

  • 이진효;이수현;김정연;김지희;정숙녀;김진아;오석률;김익수;신진호;어수미;정권;이진숙
    • 한국산업보건학회지
    • /
    • 제24권2호
    • /
    • pp.113-121
    • /
    • 2014
  • Objectives: This study is intended to seek credible and efficient measurements on airborne asbestos concentrations that allow immediate action by establishing complementary data through comparative analysis with existing PCM and KF-100 method real-time monitoring equipment in working areas in Seoul where asbestos-containing buildings are being demolished, including living environment surroundings. Materials: We measured airborne asbestos concentrations using PCM and KF-100 at research institutes, monitoring networks, subway stations and demolition sites of asbestos-containing buildings. Through this measurement data and KF-100 performance testing, we drew a conversion factor and applied it via KF-100. Finally we verified the relationship between PCM and KF-100 with statistical methods. Results: The airborne asbestos concentrations by PCM for the objects of study were less than the detection limit(7 fiber/$mm^2$) in three (20%) out of 15 samples. The highest concentration was 0.009 f/cc. The airborne asbestos concentrations by PCM in laboratories, monitoring networks, subway stations and demolition sites of asbestos-containing buildings were respectively $0.002{\pm}0.000$ f/cc, $0.004{\pm}0.001$ f/cc, $0.009{\pm}0.001$ f/cc, and $0.002{\pm}0.000$ f/cc. As a result of KF-100 performance testson rooftops, the conversion factor was 0.1958. Applying the conversion factor to KF-100 for laboratories, the airborne asbestos concentrations ratio of the two ways was nearly 1:1.5($R^2$=0.8852). Also,the airborne asbestos concentration ratio of the two ways was nearly 1:1($R^2$=0.9071) for monitoring networks, subway stations, and demolition sites of asbestos-containing buildings. As a result of independent sample t-tests, there was no distinction between airborne asbestos concentrations monitored in the two ways. Conclusions: In working areas where asbestos-containing buildings are being demolished, including living environment surroundings, quickly and accurately monitoring airborne asbestos scattered in the air around the working area is highly important. For this, we believea mutual interface of existing PCM and a real-time monitoring equipment method is possible.

공기 중 석면농도 분석시 관상어용 기포발생기를 개조한 장치와 기존의 상업용 시료 채취기와의 성능 비교 (Comparison of the Efficiency between a Remodeled Bubble Generating Pumps for an Aquarium Fish and the Existed Commercial Air Sampler for the Sampling of Ambient Air Asbestos)

  • 장봉기;탁현욱;송수진;조봉현;김영지;손부순;이종화
    • 한국산업보건학회지
    • /
    • 제24권4호
    • /
    • pp.492-500
    • /
    • 2014
  • Objectives: The purpose of this study is to estimate the applicability of regional sample collection of environmental samples. The concentration of asbestos fibers were analyzed with two devices. One was an existing commercial air sampling pump that has been proved to be accurate and exact, and the other is a remodeled pump for sample collection which was made from an electric bubble generator originally designed for aquarium fish. Samples were collected with the two devices under the same environmental conditions and collection equipment. A comparative analysis of the concentration of ambient asbestos fiber was then performed. Methods: Based on previous research, six farmhouses with asbestos fiber slate roofs known to have high concentrations of asbestos fiber were selected. Using the existing commercial air sampling pump and the remodeled electric bubble generator, four to seven samples were collected each day one meter downwind from the edge of the slate roof at high volume (about 4 L/min) and low volume (about 1.4 L/min). The analyzer responsible for sample quality control of asbestos fibers counted the number of asbestos fibers with a phase microscope. Results: The rates of flow change of the existed sampler and the remodeled pump at high volume were 0.82% and 0.17%, respectively. The rates of flow change at low volume were 3.83% and 1.09%, but there was not significant difference. The rates of flow change are within the error range (${\pm}5%$) of OSHA analyzing methods. For the high volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 6.270 fibers/L and for the remodeled one 5.527 fibers/L, not a significant difference. For the low volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 7.755 fibers/L and for the remodeled one 7.706 fibers/L, not a significant difference. The total area of the slate roof of the targeted farmhouse has an effect on the concentration of asbestos fibers in the air from the existing pump and the remodeled one (p<0.01). Conclusions: The sampling function between the existing commercial pump and the remodeled one shows little difference. Therefore, the remodeled pump is considered a pump with a good availability for collecting ambient air asbestos samples.