Browse > Article
http://dx.doi.org/10.5806/AST.2009.22.5.369

Preparation and assessment of airborne fibrous reference sample for a proficiency test  

Lim, Hoju (Indoor Environmental Research Team, National Institute of Environmental Research)
Ryu, Jaihyuk (Indoor Environmental Research Team, National Institute of Environmental Research)
Choi, Sungho (Indoor Environmental Research Team, National Institute of Environmental Research)
Choi, Arum (Indoor Environmental Research Team, National Institute of Environmental Research)
Jung, Hyunsung (Indoor Environmental Research Team, National Institute of Environmental Research)
Ryu, Jungmin (Indoor Environmental Research Team, National Institute of Environmental Research)
Kim, Hyunwook (Dept. of Preventive Medicine, Coll. of Medicine, The Catholic University of Korea)
Jang, Seongki (Indoor Environmental Research Team, National Institute of Environmental Research)
Publication Information
Analytical Science and Technology / v.22, no.5, 2009 , pp. 369-375 More about this Journal
Abstract
We evaluated the homogeneity and accuracy of low level airborne fibrous standard, and accomplished the proper proficiency test. We had found that the correlation of concentration of standard solution and asbestos density was 0.9863~0.9968, and concluded that the proper guideline of the analysis result was ${\mid}Z{\mid}{\leq}2$ interval of Z-score.
Keywords
airborne fibrous reference sample; proficiency test;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 IARC Monographs, Sup. 7(1977)
2 이종한, 이광용, 정시정, 석면분석 정도관리용 표준 시료 개발연구, 한국산업안전공단 산업안전보건연구원 (2008)
3 실내공기질공정시험방법, 환경부 (2004)
4 C. Ilsabe and Lois L. Niemeyer, Gerchman, Preparation of asbestos filter samples for reference standard using a wet generation technique, Am, Ind, Assoc, J. 42, 757-759(1981)   DOI   ScienceOn
5 J. Cherrie, A. Jones and A. Johnston, The Influence of Fiber Density on the Assessment of Fiber Concentration Using the Membrane Filter Method. Am. Ind. Hyg. Assoc. J., 474(1986)
6 C. S. Paul and A. S. Stanley, Performance of asbestos fiber counting laboratories in the NIOSH proficiency analytical testing (PAT) program, am. IND. HYG. ASSOC. J., 47(5), 259-269(1986)   DOI   PUBMED   ScienceOn
7 L. W. Ortiz and Harry J. Ettinger, Charles I. Fairchild, Calibration standard for counting asbestos, Am, Ind, Assoc, J. 36, 104-112(1975)   DOI   ScienceOn
8 V. Timbell and R. E. G. Rendall, Preparation of the UICC Standard reference samples of asbestos powder technology, 5, 279-287(1970)   DOI   ScienceOn
9 A. Skogstad, W. Eduard and P. O. Huser, A laboratory method for generation of replicate filter samples of asbestos fibers in air, AIHA J., 57, 741-745(1996)   DOI   PUBMED   ScienceOn
10 강보영, 신용철, 백남원, 위상차 현미경법을 이용한 공기 중 석면농도 분석에서의 정도관리, 서울대학교 보건대학원, 한국위생학회지, 제 1권, 제 2호, 221-237 (1991)