• Title/Summary/Keyword: 서지발생기

Search Result 69, Processing Time 0.034 seconds

Degradation Properties of ZnO Surge Arresters Due to Lightning Impulse Currents (뇌임펄스전류에 의한 ZnO 피뢰기의 열화특성)

  • Lee, Su-Bong;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.79-85
    • /
    • 2009
  • This paper describes the degradation properties of ZnO surge arresters impressed by lightning impulse currents. To investigate the deterioration behaviors of ZnO surge arresters due to lightning surges, the 8/20[${\mu}s$], 2.5[kA] standard lightning impulse currents were injected to the ZnO surge arrester under test. The power frequency AC and DC leakage currents flowing through the ZnO surge arresters with and without the injection of lightning impulse currents were measured. As a result, the leakage currents are increased and the asymmetry of the AC leakage current is pronounced as the number of injection of the impulse current increases. The ZnO grain of the surge arrester without the injection of lightning surges are uniform but the ZnO grain of the ZnO surge arrester with the injection of lightning impulse currents are deformed. Also, it was found that the decrease of the $Bi_2O_3$ due to the lightning impulse current leads to the lack of grain boundary layer and the current concentrated by the lack of grain boundary layer play an important role to degrade nonlinear property of ZnO surge arrester blocks.

Flow Instability Assessment Occurring in Low Flow Rate Region According to the Change of a Centrifugal Compressor Impeller Shape (원심압축기 임펠러의 형상 변화에 따른 저유량 영역에서 발생하는 불안정 유동 평가)

  • Jo, Seong Hwi;Kim, Hong Jip;Lee, Myong Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.2
    • /
    • pp.21-26
    • /
    • 2016
  • The objective of present study is to assess the performance of the first stage compressor in a total 3-stage 5000 HP-level turbo compressor. CFD commercial code, CFX has been used to predict three-dimensional flow characteristics inside of the impeller. Shear Stress Transport (SST) model has been used to simulate turbulent flows through Reynolds-averaged Navier-Stokes (RANS) equations. Grid dependency has been also checked to get optimal grid distribution. Numerical results have been compared with the experimental test results to elucidate performance characteristics of the present compressor. In addition, flow characteristics of the impeller only have been studied for various blade configurations. Angular offset in leading edge of the blade has been selected for the optimal blade design. Performance characteristics in region of low mass flow rate and high pressure ratio between the impeller entrance and exit have been investigated for the selection of optimal blade design. Also, flow instability such as stall phenomena has been studied and anti-stall characteristics have been checked for various blade configurations in the operational window.

Three-phase Current-fed Active Clamped DC-DC converter for Fuel cells (연료전지용 3상 전류형 능동클램프 DC-DC 컨버터)

  • Cha, Han-Ju;Choi, Jung-Wan
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.71-73
    • /
    • 2007
  • 본 논문에서는 새로운 연료전지용 3상 전류형 능동 클램프 DC-DC 컨버터를 제안한다. 전류형 컨버터 구조에 능동 클램프 회로를 채용하여 과도기에 발생하는 서지전압을 저감하였고 모든 스위치에서 영전압 스위칭을 하며, 그 장점으로 : 연속적인 입력전류, 전압 오버슈트 제거, 영전압 턴 온 스위칭, 고주파 변압기 1차/2차 측에 부가적인 스너버 회로의 필요성 제거, 소프트 스위칭에 의한 저속 다이오드 적용 등이 있다. 더구나 대용량 발전 시스템에 적합하도록 전류형 컨버터 구조와 3상 전력변환 회로를 결합하였다. 3상 전력변환 적용의 장점은 : 입력전류 및 출력전압 주파수의 3배 증가, 스위치에 흐르는 RMS 전류 저감, 필터소자 용량 및 부피 감소, 고주파 변압기 이용률 증가, 전력회로의 단순화에 따른 전체 사이즈 축소 및 신뢰성 향상 등이 있다. 제안하는 3상 전류형 능동 클램프 DC-DC 컨버터는 이러한 장점들 때문에 발전용 연료전지 시스템의 승압형 DC-DC 컨버터에 적합하며 대용량 태양전지 발전 시스템 및 배터리 충전기 등에도 적용할 수 있다. 새로운 3상 DC-DC 컨버터와 함께 3상 PWM 알고리즘을 제안하며, 시뮬레이션과 프로토타입 제작, 실험을 통하여 그 성능을 평가, 확인한다.

  • PDF

A Vibration Mode Analysis of Cable-type Winding for Distribution Power Transformer by using Transfer Matrix Method (변환행렬법을 이용한 케이블 권선형 배전용 변압기 귄선의 진동모드 해석)

  • Shin, Pan-Seok;Chung, Hyun-Koo;Yoon, Koo-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.85-91
    • /
    • 2009
  • This paper proposes a simulation method of the internal winding fault to calculate the short-circuit current, electromagnetic force and vibration mode in a distribution power transformer by using FEM program(FLUX2D) and analytic algorithm. A usage of the Transfer matrix method is also presented for the vibration mode analysis of the cable-type winding of power transformer. The equations of the winding are approximated by the series expansions of the distributed mass mode and Timoshenko's beam theory. The simulation examples are provided for the cable type winding of the transformer(22.9[kV]/220[V], 1,000[kVA]) to verify the method. The proposed Transfer Matrix Method is also verified by the ANSYS program for the vibration mode of the transformer winding. The method presented may serve as one of the useful tools in the electromagnetic force and vibration analysis of the transformer winding under the short circuit condition.

Pulmonary carcinoid tumor presented with recurrent pneumonia in adolescence (반복되는 폐렴으로 내원한 청소년기 폐 칼시노이드 종양)

  • Park, Eun Sil;Park, Ji Suk;Seo, Ji-Hyeon;Lim, Jae Young;Lee, Joung Hee;Ko, Gyung Hyuck
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.7
    • /
    • pp.805-809
    • /
    • 2006
  • The incidence of endobronchial tumor in the pediatric period is very rare and the symptoms are very close to those of respiratory tract infection. Diagnosis can be delayed because of low clinical suspicion and the many ways in which these tumors can present. We report the first case, in Korea, of a pulmonary carcinoid tumor that presented with recurrent pneumonia at the same location in adolescence. Treatment is surgical and geared towards complete resection while sparing healthy lung parenchyma. Long-term and careful follow up is recommended to detect local and distant metastasis.

The Protective Countermeasure of Water Purifier PCB according to Abnormal Voltage (이상전압에 따른 정수기 PCB의 보호대책)

  • Kim, Dong-Ook;Moon, Hyun-Wook;Lee, Ki-Yeon;Kim, Hyang-Kon;Choi, Chung-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.64-70
    • /
    • 2007
  • The electrical accident results from an insulation blackdown by over-voltage, an overheating by the excess of allowable current, a deterioration performance by the passage of time, and so on. This paper discusses how to improve the power control system of PCB in water purifier. The protecting device of present power supply control system in water purifier is composed of the varistor device which acts only for impulse-type surges. So the present system can not be protected others except the surge of impulse-type. The newly-suggested power control system in this paper is designed to protect the system by disconnecting power supply through SSR(Solid State Relay) if the value of input voltage is exceeded the setting value.

A New Active Lossless Snubber for Half-Bridge Dual Converter (하프 브릿지 듀얼 컨버터를 위한 새로운 능동형 무손실 스너버)

  • 한상규;윤현기;문건우;윤명중;김윤호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.5
    • /
    • pp.419-426
    • /
    • 2002
  • A new active lossless snubber for half-bridge dual converter(that is called'dual converter') is proposed in this paper It features soft switching(ZVS) as well as turn-off snubbing in both main and auxiliary switches. Therefore, it helps the dual converter to operate at the higher frequency with a higher efficiency and smaller-sized reactive components. Moreover, since it uses parasitic components, such as leakage inductances and switch output capacitances etc, to achieve the ZVS of power switches, it has simpler structure and lower cost of production. The operational principle, theoretical analysis, and design consideration are presented. To confirm the operation, features, and validity of the proposed circuit, experimental results from a 200w, 24V/DC-200V/DC proto-type are presented.

Effect of Surface cover on Runoff Residue - An Indoor Rainfall Simulation - (지표 피복의 유출율 감소 효과 - 실내 인공강우 시험 -)

  • Choi, Yong-Hun;Shin, Min-Hwan;Kim, Ki-Chul;Seo, Ji-Yeon;Lim, Kyoung-Jae;Choi, Jung-Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1036-1040
    • /
    • 2008
  • 수질 개선을 위한 많은 노력과 투자를 하고 있다. 하지만 농경지의 부적절한 관리로 인한 토양유실로 발생하는 오염은 여전히 큰 비중을 차지하고 있다. 특히 강원도는 산이 많아 농경지의 대부분이 경사지에 위치하고 있다. 경사진 농경지는 그 특성상 토양유실이 일어나기 쉬운 조건에 있다. 경사지의 토양 유실은 지력을 저하시킨다. 또한 토양과 함께 유실되는 유기물 및 양분은 농경지의 손실이며 주변 수역으로 유입되어 수질 오염의 원인이 된다. 이런 토양 유실은 직접유출량과 큰 연관이 있다. 본 연구에서는 강우강도, 경사도, 피복도를 동일하게 조정할 수 있는 실내 인공강우 시험기를 사용하여 직접유출율을 산출하였다. 피복재료는 볏짚거적을 사용하였다. 강우강도는 30 mm/h와 60 mm/h 그리고 경사도는 10 %와 20 %를 사용하였다. 볏짚거적 피복처리는 0 kg/ha (나지), 3,000 kg/ha (볏짚 1겹), 6,000 kg/ha (볏짚 2겹), 10,000 kg/ha (볏짚 3겹) 이었다. 강우강도 30 mm/h, 경사도 10 % 인 시험포는 볏짚 1겹으로만 피복하여도 직접유출율이 0.77 %로 유출이 거의 발생하지 않았다. 강우강도 30 mm/h, 경사도 20 % 인 시험포의 직접유출율은 피복이 볏짚 1겹인 경우 16.9 %, 볏짚 2겹인 경우는 0 %로 매우 낮았다. 강우강도 60 mm/h, 경사도 10 % 인 시험포는 피복이 볏짚 2겹인 경우 3.4 % 로 매우 낮았다. 강우강도 60 mm/h, 경사도 20 % 인 시험포는 피복이 볏짚3겹인 경우 16.58 % 로 나타났으며, 볏짚 피복을 4겹 이상으로 할 경우 더 큰 저감 효과를 가져 올 수 있을 것으로 판단된다. 따라서 본 연구의 결과로 경사진 농경지의 직접유출량을 저감시켜 토양유실과 탁수를 줄이기 위한 방법으로 볏짚 피복을 선택하면 효과적인 것으로 사료된다.

  • PDF

A Study on Power Conversion System for Fuel Cell Controlled by Micro-Processor (마이크로프로세서에 의해 제어되는 연료전지용 전력변환장치에 관한 연구)

  • Kim, Ju-Yong;Jung, Sang-Hwa;Mun, Sang-Pil;Ryu, Jae-Yup;Suh, Ki-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.10-24
    • /
    • 2007
  • In the dissertation, a power conversion system for fuel cell is composed of a PWM inverter with LC filter in order to convert fuel cell voltage to a single phase 220[V]. In addition, new insulated DC-DC converters are proposed in order that fuel cell voltage is boosted to 380[V]. In this paper, it requires smaller components than existing converters, which makes easy control. The proposed DC-DC converter controls output power by the adjustment of phase-shift width using switch $S_5\;and\;S_6$ in the secondary switch which provides 93-97[%] efficiency in the wide range of output voltage. Fuel cell simulator is implemented to show similar output characteristics to actual fuel cell. Appropriate dead time td enables soft switching to the range where the peak value of excitation current in a high frequency transformer is in accordance with current in the primary circuit. Moreover, appropriate setting to serial inductance La reduces communication loss arisen at light-load generator and serge voltage arisen at a secondary switch and serial diode. Finally, TMS320C31 board and EPLD using PWM switching technique to act a single phase full-bridge inverter which is planed to make alternating current suitable for household

Characteristics of Hydaulic Conductivity in Middle-Jeju watershed (제주도 중제주유역의 수리전도도 특성)

  • Kim, Min-Chul;Yang, Sung-Kee;Lee, Jun-Ho;Yang, Won-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.386-386
    • /
    • 2017
  • 지하수 해석을 위해 3차원 수치해석 모형이 적용되고 있으나, 다양한 매개변수를 명확히 적용하기에는 한계가 있다. 특히, 수리전도도는 지층의 투수성정도를 나타내는 계수로 지하수 분석에 매우 중요한 매개변수이다. 신뢰성의 확보를 위해 양수시험을 통해 산출된 결과를 이용하고 있으나 소수관정의 시험결과를 유역의 대푯값으로 적용하기에 불확실도가 매우 높고, 수위변화가 독특한 지역의 정확한 수리특성을 적용하기에 한계가 있다. 이 연구에서는 수리전도도 특성을 해석하기 위하여 3차원 수치해석모형을 적용하였으며, 모델보정 방법 중 Regularization(정규화)라고 불리는 Pilot point 기법을 사용하였다. 제주도와 같이 수리전도도 값이 지역별로 차이가 크고 동일 유역 내에도 다른 지질구조를 보이는 등 동일 매질에서 동일 투수성을 보이지 않는 다양함으로 실측값들을 적용하기에 어려운 곳에서 정규화라는 보정방법은 최적화된 방법이다. 지하수위는 중제주유역 내 위치한 12개소 수위관측정의 2016년 연평균수위를 적용하였다. 미계측지역은 제주도 등수위선자료를 이용하여 DEM을 구축하였으며, 임의지점 17개소를 선정하여 대표수위로 적용하였다. 중제주유역의 평균 수리전도도는 82.90 m/day로 분석되었으며, 유역의 동측 하류부는 최대 1,745 m/day로 비교적 큰 결과가 산출되었다. 유역의 중앙에 위치하는 OR관측정을 기준으로 동 서지역의 지하수위를 검토한 결과 서측은 지형구배에 따라 지하수위가 형성하고 있으나, 동측의 경우 상 하류의 표고차가 30m이상 발생되지만 지하수위는 유사한 형태를 보이고 있다. 지하수 흐름에 해석되는 Darcy의 방정식은 수리전도도와 동수경사는 반비례관계를 나타내며, 이 이론에 의해 상 하류 지하수위가 유사하게 형성되는 동측지역은 국부적으로 수리전도도가 높게 형성되는 것으로 확인되었다. 실무에서는 유역경계에 따라 평균화된 매개변수가 적용되므로 명확한 지하수 해석이 어렵고, 수리전도도와 같이 지역적 편차가 심한 매개변수는 다양한 연구를 통해 적용성검토가 수행되어야 한다.

  • PDF