• Title/Summary/Keyword: 서리 성장

Search Result 29, Processing Time 0.026 seconds

A Study of Frost Formation on Different Hydrophilic Surfaces (다른 친수성능을 가진 두 표면에서의 착상에 관한 연구)

  • 김철환;신종민;하삼철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.519-524
    • /
    • 2002
  • An experimental study has been conducted to investigate the effects of surface energy on frost formation. Test samples with two different surfaces are installed in a wind tunnel and exposed to a humid airflow. Dynamic contact angles (DCA) for these surfaces are $23^{\circ}\;and\;88^{\circ}$, respectively. The thickness and the mass of frost layer are measured and used to calculate the frost density while frost formation is visualized simultaneously with their measurements. Results show that frost density increases as time increases at specific test conditions. The air Reynolds number, the airflow humidity and the cold plate temperature are maintained at 12,000, 0.0042 kg/kg and $-21^{\circ}C$, respectively. The surface with a lower DCA shows a higher frost density during two-hour test, but no differences in the frost density have been found after two hours of frost generation. Empirical correlations for thickness, mass and density are assumed to be the functions of the test time and DCA.

Effects of Humidity and Velocity on Frost Distribution Characteristics of Humid Air Flow on Cold Surfaces (차가운 표면위에서의 습공기 유동의 습도 및 속도가 착상분포 특성에 미치는 영향)

  • Kwon Jeong-Tae;Rew Keun-Ho;Lim Hyo-Jae;Han Ji-Won;Kwon Young Chul
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.213-218
    • /
    • 2005
  • In order to understand the heat and mass transfer characteristics of humid airflow in frosting conditions, a flat plate of aluminum with cooling modules located in the central part of the plate was used. A microscope system (resolution of 0.05 mm) was used for the measurement of local thickness of frost at seven points along the plate in the flow direction. For the total mass of frost at each test operation, an electronic balance (resolution of 1 mg) was used. The local frost thickness distributions far various test conditions were presented along with the frost mass data measured at the given operating times. The effect of humidity and velocity of humid air on frosting were analyzed.

Behaviors of Frost Formation on a Plate Fin Considering Fin Heat Conduction (휜의 열전도를 고려한 평판 휜에서의 착상 거동)

  • Kim, Jeong-Su
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.38 no.12
    • /
    • pp.51-60
    • /
    • 2009
  • 본 연구에서는 착상 조건 하에서 열교환기 휜의 열전도를 고려하여 휜 표면에서의 착상 거동을 예측하기 위하여 수학적 모델을 제시한다. 이 때, 공기측은 착상 현상에 대한 3차원 유동 변화의 영향을 고려한다. 서리층 두께에 대한 해석 결과는 실험 결과를 최대 10% 오차 내에서 잘 예측한다. 유동에 수직한 방향(z-dir.)의 서리층 두께 성장은 휜의 열전도에 의해 휜 바탕 근처에서 활발하고, 휜 끝으로 갈수록 지수함수적으로 둔화된다. 휜의 열전도를 고려한 경우에 비해 휜의 표면온도가 일정한 조건에서 서리층 두께는 최대 2배, 열전달량은 평군 10% 정도 과대 예측한다. 따라서, 열교환기 휜에서의 착상 거동을 정확하게 예측하기 위해 착상 모델 해석 시 휜의 열전도를 고려해야 한다. 휜의 열전도 고려 유무에 따른 착상 거동의 차이를 보완하기 위해 열전달량에 대한 등가온도를 산출하며, 이를 근거로 무차원 등가 온도 상관식을 도출한다.

  • PDF

The Leadership Competition of Smart Platforms in the ICT Ecosystem: Comparative Analysis of Samsung Electronics and SK Telecom in the Appcessory Market (ICT생태계에서의 스마트폰 플랫폼 주도권 경쟁: 앱세서리 시장을 중심으로 본 삼성전자와 SK텔레콤 전략분석)

  • Cho, Hye Jin;Park, Chanhi
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.10 no.6
    • /
    • pp.187-202
    • /
    • 2015
  • The continued development of smart devices representing smart phones and tablet PC has made significant changes to the ICT ecosystem. Along the development of smart devices, consumers' needs are also becoming increasingly diversified in addition to their rising expectations. Thus, in order to fulfill the changing customer needs, corporations in the ICT ecosystem have recently focused on appcessory products that are interlinked and utilized in existing smart devices. This study particularly analyzes the two corporations, Samsung Electronics and SK Telecom, which recently plunged into appcessory business. By the case study of these two companies based on the theories of ecosystem and platforms, this study analyzes the current status of the appcessory market, the potentials and significances of the business, business background of the two corporations, and the status of leadership competition in the appcessory market. In the case of Samsung Electronics and SK Telecom, the study shows that both corporations acquired new growth powers in the appcessory market with their entry into existing or other relating markets. Also, since the appcessory business is highly related to their existing businesses, each company was able to take advantages based on the capability that they already possessed and this relationship had positive effects on their overall businesses. In addition, the two corporations had common strategies in increasing their competitiveness by identifying internal weaknesses and building external cooperations. On the other hand, since the two companies have different business areas, their business background, business strategies, and the effects of expectations varied to each other. Thus, this study identifies commonalities and differences between recent smart platforms and corporations' engagement in the fierce leadership competition in the appcessory market.

  • PDF

Prediction of Frost Layer Growth on a Cold Plate (저온 평판에서의 서리층 성장 예측)

  • Jhee, Sung;Lee, Kwan-Soo;Yeo, Moon-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.9
    • /
    • pp.1325-1331
    • /
    • 2002
  • This study presents a numerical model to predict the behavior of frost layer growth. The characteristics of the heat and mass transfer inside the frost layer are analyzed by coupling the air flow with the frost layer. The present model is validated by comparing with the several other analytical models. It has been known that most of the previous models cause considerable errors depending on the working conditions or correlations used in predicting the frost thickness growth, whereas the model in this work estimates the thickness of the frost layer more accurately within an error of 10% in comparison with the experimental data. Simulation results are presented for variations of heat and mass transfer during the frost formation and for the behavior of frost layer growth along the direction of air flow.

The numerical model for predicting frost layer growth (서리층 성장 예측을 위한 수치적 모델)

  • Lee, K.S.;Jhee, S.;Lee, T.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.249-258
    • /
    • 1997
  • In this study, a numerical model for analyzing frost formation phenomena on a cold flat plate has been developed. Both regions of air flow and frost layer have been coupled to calculate the amount of the heat and mass transfer between air flow and frost layer. Experiments have been also conducted to validate the numerical model. The present numerical results show a good agreement with the experimental data. The present numerical model also provides some useful data such as the temperature distribution inside the frost layer which could not be obtained through the experiments.

  • PDF

Growth of frost formed on heat exchanger fins (열교환기 휜에서의 서리 성장)

  • An, Won-Jun;Kim, Jung-Soo;Lee, Kwan-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.256-261
    • /
    • 2008
  • In this study, frost behavior on two dimensional fins of a heat exchanger was experimentally investigated. Temperature distribution on a 2-D fin surface and frost properties were measured in the directions perpendicular to and parallel to airflow. The results indicated that the temperature gradient in the direction perpendicular to airflow was large because of fin heat conduction, while that in the direction parallel to airflow was very small. Frost thickness in the airflow direction decreased from the leading edge towards the trailing edge of the fin due to leading edge effect. The reduction rate of frost thickness in the airflow direction, however, was very small compared with that in the direction perpendicular to the airflow, as affected by the temperature distribution.

  • PDF

Performance Comparison of Fin-Tube Type Evaporator using R134a and R1234yf under the Frost Condition (착상조건에서 R134a와 R1234yf를 적용한 핀-관 형태의 증발기 성능 비교)

  • Shin, Yunchan;Kim, Jinhyun;Cho, Honghuyn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.5795-5801
    • /
    • 2015
  • The low temperature distribution of the refrigerated and frozen food has been increased gradually. Refrigeration industry is using R134a refrigerant, which GWP is 1300. R1234yf is an alternative refrigerant of R134a because GWP of R1234yf refrigerant is just 4. Evaporator used in refrigeration truck refrigeration system is operated on low temperature condition. Accordingly, evaporator is formed frost and the formation of frost is rapidly decreased performance of evaporator. In this study, the performance of evaporator using R134a and R1234yf refrigerant was analyzed with operating conditions under frost condition. As a result, the performance of R134a evaporator according to air inlet temperature, relative humidity and evaporating temperature was more sensitive than R1234yf evaporator. Besides, the frost growth of R134a evaporator is steeper than that of R1234yf one.

Effects of fin pitch and array of the frost laver growth on extended surface of a heat exchanger (열교환기 표면에서의 서리층 성장에 대한 휜 피치와 배열의 영향)

  • Yang, Dong-Keun;Lee, Kwan-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1461-1466
    • /
    • 2003
  • This paper presents the effects of the fin array and pitch on the frost layer growth of a heat exchanger. The numerical results are compared with experimental data of a cold plate to validate the present model, and agree well with experimental data within a maximum error of 8%. The characteristics of the frost formation on staggered fin array are somewhat different from those of in-line array. The frost layer at the first fin of the in-line array grows rapidly, compared to second fin, whereas the difference of the frost layer growth between the fins of the staggered array is small. For fin pitch below 10 mm, the frost layer growth of second fin in the staggered array is affected by that of first fin. The frost layer growth and heat transfer of single fin deteriorate with decreasing fin pitch regardless of fin array, however, the thermal performance of a heat exchanger, considering increase of heat surface area, becomes better.

  • PDF

Effects of Fin Pitch and Array on the Frost Layer Growth on the Extended Surface of a Heat Exchanger (열교환기 표면에서의 서리층 성장에 대한 휜 피치와 배열의 영향)

  • 양동근;이관수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.711-717
    • /
    • 2003
  • This paper presents the effects of the fin array and pitch on the frost layer growth of a heat exchanger. The numerical results are compared with experimental data of a cold plate to validate the present model, and agree well with experimental data within a maximum error of 8%. The frost behaviors of the staggered fin array are somewhat different from those of in-line array. The frost layer formed on the first fin of the in-line array grows rapidly, compared to second fin, whereas the difference of the frost layer growth between the fins of the staggered array is small. For fin pitch below 10 m, the frost layer growth of second fin in the staggered array is affected by that of first fin. The thickness of the frost layer and heat transfer of single fin are reduced with decreasing fin pitch regardless of fin array. However, the thermal performance of a heat exchanger is enhanced due to the increase of heat transfer surface area.