유닛모듈러 기반 도시형 생활주택의 BIM 모델링 프로세스 개발 연구 (The Study on the Developing Process of BIM Modeling for Urban-life-housing Based on Unit Modular)

  • 이창재;임석호
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.77-84
    • /
    • 2012
  • The current architectural design of unit modular has been based on 2D of CAD program, so unit modular character which needs unit information management, as a dried-member system, has no effect on design process. The purpose of this study is We have developed a suitable BIM design process, according to various works of construction, then tried to contribute to supply and activation of the urban-life-housing based on unit modular. The BIM modeling process based on unit modular has been in order of unit combination with preparing manual classification, and, it has been constructed, at construction site, from housing foundation to roof finish by Bottom-up method. At a manufacturing factory, it has been produced in order of 1) grouping materials and parts, 2) fabricating unit boxes, and 3) interference examination of unit boxes, and each order has been classified as housing structure, architecture, plumbing process separately. At a construction site, the fabrication has been done in order of, like as a real housing construction scenario, 1) RC foundation work 2) unit module job-site-fabrication work, 3) roof truss work, 4) plumbing and HVAC work, and 5) housing interior finish work. After modeling process, the interference examination on each work of construction has finally completed modeling. The Unit modular utilizing BIM modeling can make easy housing maintenance through systematic control with preparing manual of unit module information, and securing accurate and speedy construction information. And it will promote design credibility and create maximum effect of unit modular construction method, such as construction period reduction and upgrade of construction quality, etc., through the computer simulation as real as construction environment in cyber space, and with the interfering examination.

공공임대주택 단위 수선비용 특성 분석 (The Characteristics of the Repair Unit Cost in Public Rental Housing)

  • 이강희;채창우
    • KIEAE Journal
    • /
    • 제14권5호
    • /
    • pp.103-109
    • /
    • 2014
  • Apartment housing should require the systematic maintenance to provide the decent living condition during its life. Each household should participate the maintenance activities and pay for the repair. Therefore, the required cost for repair would be needed to plan in the repair schedule because each household could not pay the much repair money at a time. After apartment constructed, a long term repair plan would be prepared in repair time, repair scope and a required cost. A few studies are said that the repair cost depends on the building deterioration, elapsed year and management factors. The above factors are not be certain to affect the repair management while it may be important to prepare the required money and the repair time. In this paper, it aimed at analyzing the correlation between the repair management and the management factors, especially total area, number of household. This would educe the unit cost per number of household and management area in the individual boiler and elevator with full change and full repair. The unit cost per number of household and area for full change are about 199,000 won/household and $1,954won/m^2$ in the individual boiler respectively. The unit cost of the elevator for full change is 94,000 won/household and $5,429won/m^2$ respectively. Second, this study shows that the elapsed year after construction would not be related the repair unit cost.

기존 공동 주택의 벽체 열성능 현장 측정법에 관한 연구 (The study of in-situ measurement method for wall thermal performance diagnosis of existing apartment)

  • 김서훈;김종훈;류승환;정학근;송규동
    • KIEAE Journal
    • /
    • 제16권4호
    • /
    • pp.71-77
    • /
    • 2016
  • Purpose : The energy saving in a residential building (apartment) sector is known as one of the effective solution of energy reduction. In South Korea, the government has recently reinforced regulations associated with the energy performance of buildings. However, there is a lack of research on the methods for the energy performance diagnosis that is used to analyze the wall thermal performance of the existing apartments. Because a reliable diagnosis is necessary to save the building energy, this study analyzed wall thermal performance of an existing apartment in Seoul. Method : This paper applied two methods for analysis of the thermal insulation performance; HFM(Heat Flow Meter) method and ASTR(Air-Surface Temperature Ratio) method. The HFM method is suggested by ISO9869-1 code to measure the thermal performance. The ASTR method is proposed by this study for the simplified In-situ measurement and it uses three temperature data (interior wall surface, interior and exterior air) and the overall heat transfer coefficient. This study conducted the experiment of an existing apartment in Seoul using these methods and analyzed the results. Furthermore, the energy simulation tool of the building was used to suggest retrofit of the building based on the results of measurements. Result : The error rate of HFM method and ASTR method was analyzed in about 17 to 20%. As the results of comparison between the initial design values of the wall and the measured values, the 26% degradation of insulation thermal performance was measured. Lastly, the energy simulation tool of the building shows 10.8% energy savings in accordance with the construction of suggested retrofit.

공동주택 외피의 열교영향을 고려한 상당열관류율 및 연간 에너지소비성능 평가 연구 (A study on the annual energy performance of apartment building with the equivalent U-value of envelope considering the effect of thermal bridges)

  • 김동수;윤종호;신우철;곽희열
    • KIEAE Journal
    • /
    • 제12권3호
    • /
    • pp.41-46
    • /
    • 2012
  • The building envelope is important specially for saving energy consumption of residential buildings. but Apartment houses in Korea commonly have inside insulation system which have constantly arisen thermal bridges, the risk of heat loss, as a necessity. This study aims to evaluate integrated insulation performance according to the different shapes of external walls, adjacent to windows. The thermal performance analysis was carried out by Equivalent U-value and using the three-dimensional heat transfer computer simulation (TRISCO-RADCON), under nine different cases of comparing among three each of different bases(current standard model, 30percent energy saving model and 60percent energy saving model). The heating and the cooling load were also compared between two cases (standard U-value and Equivalent U-value) of three each of different bases, using the Building energy simulation which is based on DOE-2.1 analysis. As results, it turns out that if the Equivalent U-value is considered on the envelope analysis, the heat flow loss will be increasing more than the standard U-value, and if heat insulation property of the residential building reinforced rather than current, the rate of influences on the thermal bridges would be extremely expanded. In addition, it is shown that annual heating loads of the apartment house with applied Equivalent U-value substantially increased by more than 15 percent compared to those with the existing U-value, but annual cooling loads were negligibly affected.

공동주택단지배치의 간극비와 바람장의 상관관계에 관한 연구 (A Study on Correlations of the Gap Ratio of Apartment Houses Arrangement and the Wind Field)

  • 문출성;오세규;조성우
    • KIEAE Journal
    • /
    • 제11권2호
    • /
    • pp.75-82
    • /
    • 2011
  • In Korea, the ratio of population in urban areas used to be only 50.1% in 1970, but with the value risen to 90.8% in 2009, urbanization is going on rapidly. Urbanization, which occurs by the rampantly planted buildings, has become major source of raising building density, changing wind direction and reducing wind amount, and such reductions are affecting even inside the building. In each year, among the total energy consumption in Korea, residential portion takes up significant ratio, and specifically the ratio of apartment house is shown to be highest. In order to solve such problem, many studies are being conducted for the improvement of natural ventilation performance. The natural ventilation performance of apartment house are significantly determined by the characteristics of external and internal structure, but in macroscopic perspective, the performance is established fundamentally by the layout characteristics of the main building of the apartment house in preparation for wind conditions. So far researches on raising the thermal comfort through elevation of ventilation performance have been conducted actively, but many of them propose only theoretical concepts deduced through wind path analysis, and do not include any indicator to measure ventilation performance simply only with area data from layout planning stage. Therefore, in this study, gap ratio a wind field measuring indicator was developed, and after the ventilation characteristics by layout types and main building uniformity were identified, the scope of gap ratio efficient for ventilation and that of uniformity were clarified, followed by verification through simulation.

창호의 성능 및 건물의 창면적비에 따른 기존 단독주택의 창호 리모델링 방안 연구 (Optimum Method of Windows Remodeling of Existing Residential according to the Window Properties and Window Wall Ratio)

  • 이나은;안병립;정학근;김종훈;장철용
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.71-78
    • /
    • 2013
  • A need for building energy efficiency is on the issue since energy demand in the building stock in Korea represents about 24% of the final energy consumption. As a way of improving the thermal performance of buildings for reducing maintenance costs and environmental conservation, a lot of effort is shown to improve the building energy efficiency by applying improvement of envelope insulation performance for buildings whose energy efficiency is low relatively through the remodeling. The windows of building envelopes are areas that lead to the biggest heat loss in the building. So windows are considered to be the primary target of energy efficiency in remodeling and various studies for windows have been done. Currently, however, only U-factor and airtightness of windows performance are regulated. Window wall ratio(WWR) and solar heat gain coefficient(SHGC) of windows are not considered when conducting the remodeling. In this study appropriate performance of windows(U-factor and SHGC) for existing residential is proposed according to the window wall ratio by using EnergyPlus. As the results of this study, the U-factor of windows representing the maximum energy savings is $1.0W/m^2K$ but in case of SHGC, the values that indicate the maximum energy savings are different depending on the window wall ratio. Therefore, when conducting the remodeling of windows, to determine energy efficiency by considering only the U-factor is inadequate so it is necessary that appropriate windows are applied to buildings by considering window wall ratio and windows properties(U-factor and SHGC).

연접개발제한 폐지 이후 개발행위허가 심의제도 개선방안 (Improvement on Development Permit System after the Abolition of the Regulation against Continuous and Adjacent Development)

  • 김영우;윤정중
    • 토지주택연구
    • /
    • 제3권2호
    • /
    • pp.159-167
    • /
    • 2012
  • 기반시설이 부족한 녹지지역 및 관리지역 농림지역 자연환경보전지역에서 난개발을 방지하고 환경을 보호하기 위하여 도입된 연접개발제한 제도는 이들 지역의 난개발 방지에는 기여하였지만 연접개발여부의 판단이 모호하고 소규모의 분산개발을 초래하거나 개발행위허가를 피해 산지전용허가를 통한 개발행위가 야기되는 등의 문제가 유발되어 폐지되기에 이르렀다. 그러나 난개발 방지를 위해 도시계획위원회의 심의를 받도록 하고 있으나 여전히 위원구성이나 재량권 남용 등의 문제를 안고 있으며, 녹지축 보전대책의 미흡, 공간정보체계의 활용 부족, 법률별 경관관리기준의 불일치, 그리고 물리적 환경규제의 획일화 등 여러 가지 문제들이 나타나고 있다. 따라서 심의제도 운영을 위한 개선방안으로, 도시계획위원회의 구성 및 기능재편과 전문분야 집중심의제 도입, 동일 녹지축 상의 지자체들의 경우 개발행위허가 통합조정위원회를 두어 녹지축 보전방안과 개발행위허가기준 마련, 도시계획정보시스템의 조기구축 및 활용, 개발행위허가 경관관리기준을 지역 실정에 맞게 세부적으로 구축, 개발행위허가 시 재량행위 최소화를 위해 경사도, 표고, 임목본수도 이외에 생태자연도와 국토환경성평가지도 등을 추가하여 개발행위허가 판단의 기초자료로 활용하는 방안 등을 제안하였다.

피해산정형 전과정평가 기법을 적용한 콘크리트 압축강도별 환경영향 비교 분석 연구 (A Comparative Study on the Environmental Impacts by Concrete Strength Using End-point LCA methodology)

  • 김성희;태성호;채창우
    • 콘크리트학회논문집
    • /
    • 제26권4호
    • /
    • pp.465-474
    • /
    • 2014
  • 콘크리트 구조물이 전생애주기 동안 발생시키는 오염물질의 종류와 발생강도를 정량적으로 분석하고 이로 인한 인간과 생태계, 지구환경 및 자원 고갈 측면에 미치는 피해를 고려하기 위하여 피해산정형 전과정평가 기법을 적용한 콘크리트 구조물의 환경영향평가를 실시하였다. 평가대상은 25층 공동주택의 벽체 구조물이며, 동일한 기능을 수행하기 위한 콘크리트 구조물의 압축강도를 일반강도에서 고강도까지 24 MPa, 40 MPa, 60 MPa로 각각 변화시켜 평가하였다. 평가기간은 50년으로 제한하였고, 생애주기는 원료 채취부터 투입원료의 생산, 구조물의 시공, 사용 및 폐기 단계를 포함시켰다. 피해산정형 전과정평가는 전과정 영향평가(LCIA) 단계 중 정규화와 가중화 단계에서 실시되는데, 특성화 단계에서 산출된 환경영향범주 결과를 인체건강, 생태계의 질, 기후변화 및 자원고갈 관점에서 단일지수화 시킬 수 있는 모델을 제시한다. 평가 결과, 콘크리트 구조물의 환경영향은 여러 영향범주 중 지구온난화, 호흡계 무기물질, 및 비재생 에너지원의 사용으로 인한 영향이 전체 환경부하의 99% 이상을 차지하는 것으로 나타났으며, 압축강도의 변화에 따라 모든 환경영향범주의 값이 일괄적으로 증가 또는 감소하는 것이 아니기 때문에 전체적인 환경영향을 살펴보기 위해서는 종말점 수준의 피해산정형 평가모델을 적용하여 모든 환경영향범주를 종합적으로 고려할 필요가 있다.

SWMM을 이용한 남천의 연유출량 추정 (The Annual Runoff Estimation of Namchun Using SWMM)

  • 김남욱;류시완
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.1109-1113
    • /
    • 2010
  • 창원시는 경제성장에 따른 도시화 현상으로 경작지나 녹지와 같은 투수지표면이 대단위 주택단지나 도로, 상업지구, 공장시설과 같은 불투수지표면으로 변화되어 전형적인 도시 유역특성을 띠고 있어 SWMM 모형의 적용에 적합하다. 적용대상인 남천은 창원시를 관류하는 유로연장 14.7 km의 하천으로 지류인 창원천을 포함하고 있으며, 2007년부터 환경부 지원 시범사업으로 생태하천복원사업이 계획되어 실시설계 완료 후 공사가 진행 중이나, 복원 후 하천관리를 위한 유지유량 산정 등의 타당성과 관련한 문제가 지역사회에서의 화두로 대두되고 있다. 따라서 본 연구에서는 남천 유역의 특성을 적절히 고려한 유지유량 산정을 통해 향후 복원된 남천의 하천관리기준을 제시하고자 하였다. 본 연구에서는 2008년 실측된 남천과 창원천의 유량자료와 SWMM 유출량 모의결과를 비교, 분석하였다. 남천의 유량자료는 2008년 5월 6일부터 8월 20일까지 실측하였으며, 남천의 지류인 창원천은 유량자료 취득구간이었던 창원천교 지점에서 생태하천복원사업이 진행됨에 따라 유량자료를 취득할 수 없었으므로 남천의 유량자료를 이용하여 비유량법으로 추정하였다. 유출량 산정을 위한 강우자료는 기상청 자료를 사용하는 것이 일반적이나 마산과 창원의 강우자료를 이용한 분석 결과 강우 패턴에 차이가 있음을 발견하고 마산기상대의 자료 대신, 창원시에서 제공한 5년간 (2005년~2009년)의 자료를 사용하였다. SWAT을 이용하여 남천 유역을 39개의 소유역으로 분할하고 Arc View를 이용하여 지형인자들을 추출하여 SWMM 입력자료로 사용하였다. 입력자료 중 유출량 추정에 큰 영향을 끼치는 매개변수들은 민감도 분석을 통하여 최적의 매개변수들을 결정하고 연유출량 추정을 위한 모의를 수행하였다. 이상의 과정을 통하여 남천의 연유출량을 추정함으로써 하천관리를 위한 유지유량 산정의 기초로 활용할 수 있었다.

  • PDF

도시형생활주택의 범죄예방환경설계 측면에서 본 주거환경 실태조사에 관한 연구 - 서울시 관악구 원룸형 주택 1인가구 5개를 중심으로- (The Actual Condition investigation of Residental Environment of Urban Life-Type Housing Regarding Crime Prevention Through Environmental Design -Focused on Five Single Households in studio-type housings in Gwanak-gu, Seoul Urban Life-Type Housing-)

  • 정윤혜;이유미;이윤재
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.39-50
    • /
    • 2016
  • Purpose: The purpose of this study is to be performed with studio-type housings among urban life-type housings to investigate the physical characteristic and crime-related factors of studios from the viewpoint of the basic principles of crime prevention through environmental design (CPTED). Method: Eight CPTED guidelines available in Korea were reviewed to select 20 planing factors for actual condition investigation. Five single households in studio-type housings in Gwanak-gu, Seoul, were chosen according to the subject screening criteria to perform the actual condition investigation. Results: First, a lighting plan around a building for natural surveillance should consider the building location, relation with the front road, and surrounding facilities. In a building of a piloti structure, the parking lot and the building gate should be arranged in a manner that enables natural surveillance. Second, the shape of the corridors in studio-type housings should be considered to plan the installation of a lighting at the door of each household, the installation of a viewer window at the door of each household, and the arrangement of the elevator. Third, to support access control, an access control system having the function of video and voice communication is recommended to be installed at the building gate. Criteria for the type of security windows and the floors on which security windows should be installed, and the regulations about the CCTV installation inside and outside the building should be prepared. Fourth, to enhance territoriality in parking lots, ground patterns, parking lot gate, and signs may be installed. Fifth, in view of effective utilization and maintenance, lighting facilities should be installed to increase the usability of ground parking lots, and relevant installation criteria should be prepared regarding the type, number, and brightness of the lightings.