• 제목/요약/키워드: 생체 임피던스

검색결과 122건 처리시간 0.023초

생체 임피던스 신호를 이용한 하지동작 모니터링 (Leg Motion Monitoring using Bio-impedance Signal)

  • 송철규;변용훈;윤대영;김거식;임정모;전희천;권승범;이정훈;이명권
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2891-2894
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the variation of the lower leg electrical impedance. This impedance is measured by the four-electrode method. Two current electrodes are applied to the thigh and foot., and two potential electrodes are applied to the lateral aspect. medial aspect, and posterior position of lower leg. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least Interference, and maximum magnitude of impedance change. From such features of the lower leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level.

  • PDF

생체 임피던스 측정을 위한 새로운 네가티브 커패시턴스 프론트 엔드 (New negative capacitance front-end for bioimpedance measurements)

  • 권석영;김영필;황인덕
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2753-2756
    • /
    • 2003
  • A convenient, tunable loop-gain negative impedance circuit that increases input impedance of a front-end in a bioimpedance measurement has been proposed. Since the proposed circuit comprises wide-band operational amplifiers, selecting operational amplifiers is easy, while an operational amplifier of proper bandwidth should be chosen to use conventional circuit. Also, since loop-gain can be controlled by a feedback resistor connected serially with a feedback capacitor, loop-gain is tunable with a potentiometer. The input impedance of the proposed circuit is two times larger than that of the conventional circuit. Furthermore, closed loop phase response of the proposed circuit is better than that of the conventional circuit or without a negative capacitance circuit. The implemeted, proposed circuit showed stable operation and a zero input capacitance.

  • PDF

생체임피던스 측정을 위한 새로운 부트스트래핑 회로와 전송선로 모델링 (New bootstrapping circuit and transmission line modeling for bioimpedance measurement)

  • 김영필;권석영;황인덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 A
    • /
    • pp.179-182
    • /
    • 2003
  • A simulation on bootstrapping circuit has been performed by modelling a coaxial cable as a transmission line. It is shown that the bootstrapping circuit could be unstable due to the transmission line effect though an ideal amplifier is used. While the conventional bootstrapping circuit does not cancel the input capacitance of the input buffer, a new bootstrapping circuit that cancels input capacitance of the input buffer has been proposed. The proposed bootstrapping circuit consists of the input buffer of which gam is larger than 1 and a feedback resistor to control the loop gain. The proposed bootstrapping circuit has higher input impedance than that of the conventional circuit.

  • PDF

비침습적 복압 측정을 위한 생체 임피던스 전극의 최적 위치 선정 (Optimum electrode selection for measuring the abdominal pressure using bio-impedance method)

  • 안양수;김거식;송철규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.46-48
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2$+0.0620x+0.6958, respectively. It demonstrated that the abdominal pressure could be measured non-invasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

  • PDF

생체 임피던스 계측 방법의 구현에 관한 연구 (A Study on an Implementation of Bioelectric Impedance Instrumentation)

  • 김홍석;박세화
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.247-247
    • /
    • 2000
  • A new bioelectric impedance measurement method is proposed for the precise measurement of the bioelectric impedance. To obtain the impedance from the known applied a.c. current and the measured voltage signals, a frequency conversion circuit, like the mixer in heterodyne receivers, is introduced to reduce the frequency of the original current. It can be observed from several lines of derivation that the impedance is independent on the amplitude and phase of the mixing signals. This makes it possible to use low-speed analog-to-digital converters and thus utilize cheaper electronic parts in the implementation. The possibility of the method is shown by simulations, and a generic structure applicable to bioelectric impedance measurement devices is also proposed.

  • PDF

한국인 앉은 자세에 대한 수직 진동 -응답특성의 실험적 연구 : (II) Mechanical Impedances (Experimental Investigation of the Response Characteristics of Korean -seated Subjects under Vertical Vibration: (II) Mechanical Impedances)

  • 정완섭;김영태;권휴상;홍동표
    • 한국소음진동공학회논문집
    • /
    • 제13권9호
    • /
    • pp.713-719
    • /
    • 2003
  • This paper introduces attempts to obtain the ‘representative’ characteristics of the mechanical impedance of seated Korean subjects under vertical vibration. Individual responses of driving-point mechanical impedance obtained from forty one Korean subjects are illustrated. Four kinds of vibration levels and three different sitting postures are selected to collect the responses of each subject. Those individual responses are used to estimate the ‘mean’ mechanical impedance, which may be expected to be a representative model to Korean subjects. Several interesting features of the estimated mechanical impedance are suggested and compared to those of ISO/DIS 5982.

저 유전율 고분자 튜브 내부의 유전체 장벽 방전 연구 (Dielectric barrier discharge of the inner wall of polymer tubes)

  • 조용기;반원진;정동근
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2014년도 추계학술대회 논문집
    • /
    • pp.199-199
    • /
    • 2014
  • 좁은 관경을 갖는 상대 유전율 3 이하인 PTFE와 PE 고분자 튜브 내부에 플라즈마 방전을 일으켜 고분자 튜브 표면 그래프팅 기술을 개발 하고자 하였다. 스텐트 및 인공혈관 등에 적용이 가능한 내부지름 3 mm 이하의 원통형 고분자 생체 식립체 내부 표면을 그래프팅하는 기술이다. 좁은 고분자 튜브 내부에 생성되는 방전은 고분자의 관경에 의해 방전개시 전압이 결정되었다. 방전개시 이후 DC glow discharge 에서 나타나는 전압과 전류의 특징들이 나타났다. 전압과 전류의 파형 분석에서는 고분자 표면과 가스 간의 새로운 용량성 임피던스가 형성되는 것을 관찰하였다. 고분자 내부 표면에 플라즈마의 방전 형태는 면 방전 (surface discharge)의 형태로 나타났다.

  • PDF

체성분 측정용 스마트 의류 개발의 가능성 탐색 (An Exploratory Study on the Development of a Healthcare Smart Clothing for Measurement of Body Composition)

  • 문희성;조현승;박선형;이주현;차기철;신선영;정효일
    • 감성과학
    • /
    • 제10권3호
    • /
    • pp.383-391
    • /
    • 2007
  • 본 연구에서는 체성분 측정용 스마트 의류의 프로토타입을 개발하고 평가함으로써 헬스케어 의류로써의 개발 가능성을 탐색하고자 하였다. 직물 전극을 사용하여 개발된 두 가지 타입의 실험의복을 피험자에게 착용하도록 한 후 자세의 변화 및 1차 착용, 탈의 후 2차 착용에 따른 체성분을 측정한 결과, 동일 자세 내에서와 탈의 후 재착용 시에도 비교적 일관성 있는 측정치를 얻을 수 있었으며, 동일 자세에서는 의복 유형 및 반복 착용에 관계 없이 비교적 일관된 임피던스 측정치를 얻을 수 있었다. 또한 착용자의 신체 부위별 측정도 가능한 것으로 분석되어 향후 본 연구를 바탕으로 체성분 측정용 스마트 의류 개발이 가능할 것이라 판단된다.

  • PDF

음향 자극에 의한 인체 경락의 반응분석 (Analysis of Meridian Response by Sound Stimulus in Body)

  • 김용진;정동명
    • 전자공학회논문지SC
    • /
    • 제38권3호
    • /
    • pp.47-54
    • /
    • 2001
  • 본 논문에서는 경락의 실체를 객관화하기 위한 방법으로서, 경락과 비경락을 음향 자극하고 인체의 임피던스 변화를 분석하였으며, 인체 에너지에 대한 고전 동양의학 이론인 경락순행통로 학설의 타당성을 입증하기 위하여 경락지하수 학설을 제안하였다. 현대의학의 주장과 같이 경락은 그 존재를 증명할 만한 채널이나 파이프 형태의 해부학적 실체를 가지고 있지 않다. 그러나 생체에너지는 인체 안에서 관상구조없이 지하를 흐르는 지하수 흐름과 유사하게 경락을 따라 흐른다. 이러한 모델의 반응특성을 확인하기 위하여, 인체의 경락을 지하수가 흐르는 관로로 보고 지하수를 탐지하는 산업용 음향탐사기법을 적용하기 위하여, 피부와 청각을 구분하여 음향자극하고 경혈과 대조적인 비경혈에서의 인체 임피던스 반응을 분석하였다. 특히 자극 음향과 12경락과의 주파수 상관성을 추출하기 위하여, 5개의 특정 음으로 자극하고 측정전류의 평균치와 변화율을 처리하였다. 분석결과 전류 변화율은 족궐음간경(宮), 수소음심경(商) 30.6%, 족소음신경(角) 33.1%, 족태음비경(徵) 33.9%, 수태음폐경(羽) 30.7%로 대조점과 구별되는 특성을 가지고 있어서, 경락은 비경락과 구별되는 채널 특성을 나타내고 있으며 5개 경락은 5개의 특정 음과 상관성이 있음을 확인하였다.

  • PDF

대전 시내 초등학생의 생체 전기 임피던스치와 신체계측치에 의한 체지방율 비교 연구 (Comparison of the Estimations of Body Fat by Bioelectrical Impedence Analysis(BIA) and Anthropometric Measurements of Elementary School Students in Daejeon)

  • 왕수경;이나영
    • 한국생활과학회지
    • /
    • 제16권4호
    • /
    • pp.849-854
    • /
    • 2007
  • Body fat proportion is a major issue in health. The prevalence of obesity in childhood has been increasing on thesedays. A series of indirect estimates of body fat have been developed. There are hydrodensitometry, BIA and anthropometry equation for body fat. Hydrodensitometry has been regarded as a common criterion method. BIA made it possible to analyze body fat mass more related to hydrodensitometry than anthropometry. The purpose of this unvestigation were to compare body fat and other body composition between boys & girls and to know which anthropometry equation for body fat was most closely associated with BIA in boys & girls respectively. The subjects were 148 4th grade elementary school students(male:70, female:78). They underwent BIA(InBody 3.0, Biospace Korea)to determine body fat and other body composition. Anthropometric measurements were taken of height, weight, skinfolds and circumferences. The results obtained are summarized as follow: 1) Weight, BMI and Rohrer index were $39.9{\pm}7.2kg$, $20.5{\pm}8.0$, $138.2{\pm}17.0$ for boys and $35.9{\pm}6.7kg$, $18.2{\pm}2.6$, $96.6{\pm}13.6$ for girls. 2) Total body fat and percent body fat determined by BIA were $10.3{\pm}4.3kg$, $25.4{\pm}6.6%$ for the boys group and $9.3{\pm}3.8kg$, $25.1{\pm}6.0%$ for girls. 3) Mean triceps skinfold thickness was $20.5{\pm}6.1mm$ in boys, $17.0{\pm}5.1mm$ in girls and mean WHR was $0.88{\pm}0.4$ in bodys, $0.82{\pm}0.4$ in female and the values were significantly different by sex. 4) Correlational nanlyses showed that estimation of body fat by BIA measurement seemed to be closely associated with Rohere index(boys r=0.854, girls r=0.909). Kim's equation was highly correlated with the body fat in girls(r=0.910) but less correlated in boys(r=0.710). We need to develop specific anthropometric equations based on age and sex to determine body fat for children.