• Title/Summary/Keyword: 생각 기록

Search Result 745, Processing Time 0.024 seconds

Effects of Ambient Particulate Matter($PM_{10}$) on Peak Expiratory Flow and Respiratory Symptoms in Subjects with Bronchial Asthma During Yellow Sand Period (황사기간 중 천식 환자에서 대기 중 미세먼지($PM_{10}$)가 최대호기 유속과 호흡기 증상에 미치는 영향)

  • Park, Jeong Woong;Lim, Young Hee;Kyung, Ssun Young;An, Chang Hyeok;Lee, Sang Pyo;Jeong, Seong Hwan;Ju, Young-Su
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.6
    • /
    • pp.570-578
    • /
    • 2003
  • Background : Ambient particles during Asian dust events are usually sized less than $10{\mu}m$, known to be associated with the adverse effects on the general populations. But, there has been no considerable evidence linking these particles to the adverse effects on airways. The objectives of this study was to investigate the possible adverse effects of Asian dust events on respiratory function and symptoms in subjects with bronchial asthma. Patients and Methods : From march to June 2002, Asthmatic patients who were diagnosed with bronchial challenge test or bronchodilator response were enrolled. We divided them into three groups; mild, moderate, and severe, according to the severity. Subjects with other organ insufficiency such as heart, kidney, liver, and malignancy were excluded. All patients completed twice daily diaries and recorded peak flow rate, respiratory symptom, and daily activity. Daily and hourly mean pollutant levels of particulate matter < $10{\mu}m$ in diameter($PM_{10}$), nitrogen dioxide($NO_2$), sulphur dioxide($SO_2$), ozone($O_3$) and carbon monoxide(CO) were measured at the 10 different monitoring sites. Results : Dust events occured 14 times during the study period. Daily averages of 4 air pollutant were measured with an increased level of $PM_{10}$, decreased level of $NO_2$ and $SO_2$, and no change in CO during dust days compared to those during control days. An increase in $PM_{10}$ concentration was associated with an increase of subjects with PEF variability of >20% (p<0.05), night time symptom(p<0.05), and a decrease in mean PEF (p<0.05), which were calculated by the longitudinal data analysis. Otherwise, there was no association between $PM_{10}$ level and bronchodialtor inhaler, and daytime respiratory symptoms. Conclusion : This study shows evidence that ambient air pollution, especially $PM_{10}$, during Asian dust events, could be one of the many aggravating factors at least in patients with airway diseases. This data can be used as a primary source to set up a new policy on air environmental control and to evaluate the safety of air pollution index. We also expect that this research will help identify precise components of dust, which are more linked to the adverse effects.

Hepatotoxicity of Rifampicin and Pyrazinamide Treatment Excluding Isoniazid (Isoniazid를 제외한 Rifampicin과 Pyrazinamide 병합치료의 간독성 빈도)

  • Choi, Ik Su;Park, I-Nae;Hong, Sang-Bum;Oh, Yeon-Mok;Lim, Chae-Man;Lee, Sang Do;Koh, Younsuck;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong;Shim, Tae Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.1
    • /
    • pp.38-43
    • /
    • 2006
  • Background : Even though two-month rifampicin (RMP, R) and pyrazinamide (PZA, P) treatment has some advantages over isoniazid (INH, H) treatment for latent tuberculosis infection (LTBI), it was withdrawn from the list of treatment regimens for LTBI because of reported cases of severe hepatotoxicity. The purpose of this study was to estimate the frequency of hepatotoxicity of RMP and PZA treatment excluding INH in a Korean population. Method : TIn order to recruit patients who were prescribed RMP and PZA excluding INH, 256 INH-resistant tuberculosis patients were investigated through retrospective medical record analysis. A standard four-drug regimen was changed to a RMP/PZA-containing regimen excluding INH in 64 patients (RZ+ group). In the same study period, 146 patients who were prescribed an INH/RMP/PZA-containing standard regimen were randomly selected as a control (HRZ+ group). Clinical characteristics including liver diseases and the frequency of drug-induced hepatitis were compared between the RZ+ and HRZ+ groups. Result : The mean age of patients in the RZ+ group was 50.2 (${\pm}16.2$) and the male-to-female ratio was 36:28. The frequency of underlying liver diseases was 10.9% (7/64), which was not significantly different from that of the HRZ+ group (4.1%, 6/146). Even though the treatment duration of RZ+ ($5.5{\pm}4.8months$) was longer that than that of HRZ+ ($2.7{\pm}2.3months$), the frequency of toxic hepatitis was not significantly different between RZ+ and HRZ+ groups, 3.5% (2/57) and 7.1% (10/140), respectively. Conclusion : Hepatotoxicity was mild and occurred in a minor proportion of patients in a Korean population prescribed an RMP/PZA-containing regimen. A future prospective study including more patients is needed.

Effect of NMDA Receptor Antagonist on Local Cerebral Glucose Metabolic Rate in Focal Cerebral Ischemia (국소뇌허혈에서 NMDA 수용체 길항제가 국소 뇌포도당 대사율에 미치는 영향)

  • Kim, Sang-Eun;Hong, Seung-Bong;Yoon, Byung-Woo;Bae, Sang-Kyun;Choi, Chang-Woon;Lee, Dong-Soo;Chung, June-Key;Roh, Jae-Kyu;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.3
    • /
    • pp.294-306
    • /
    • 1995
  • There has recently been increasing interest in the use of NMDA receptor antagonists as potential neuroprotective agents for the treatment of ischemic stroke. To evaluate the neuroprotective effect of the selective non-competitive NMDA receptor antagonist MK-801 in focal cerebral ischemia, local cerebral glucose utilization (ICGU) was examined in 15 neuroanatomically discrete regions of the conscious rat brain using the 2-deoxy-D[$^{14}C$] glucose quantitative autoradiographic technique 24 hr after left middle cerebral artery occlusion (MCAO). Animals received MK-801 (5 mg/kg i.v.) or saline vehicle before (20-30 min) or after (30 min) MCAO. Both pretreatment and posttreatment of MK-801 increased occluded/non-occluded ICGU ratio in 7 and 5 of the 15 regions measured, respectively (most notably in cortical structures). Following MK-801 pretreatment, there was evidence of widespread increases in ICGU not only in the non-occluded hemisphere (12 of the 15 areas studied) but also in the occluded hemisphere (13 of the 15 areas studied), while MK-801 postreatment did not significantly increase ICGU both in the normal and occluded hemispheres. These data indicate that MK-801 has a neuroprotective effect in focal cerebral ischemia and demonstrate that MK-801 provides widespread alterations of glucose utilization in conscious animals.

  • PDF

Negative apparent resistivity in dipole-dipole electrical surveys (쌍극자-쌍극자 전기비저항 탐사에서 나타나는 음의 겉보기 비저항)

  • Jung, Hyun-Key;Min, Dong-Joo;Lee, Hyo-Sun;Oh, Seok-Hoon;Chung, Ho-Joon
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.33-40
    • /
    • 2009
  • In field surveys using the dipole-dipole electrical resistivity method, we often encounter negative apparent resistivity. The term 'negative apparent resistivity' refers to apparent resistivity values with the opposite sign to surrounding data in a pseudosection. Because these negative apparent resistivity values have been regarded as measurement errors, we have discarded the negative apparent resistivity data. Some people have even used negative apparent resistivity data in an inversion process, by taking absolute values of the data. Our field experiments lead us to believe that the main cause for negative apparent resistivity is neither measurement errors nor the influence of self potentials. Furthermore, we also believe that it is not caused by the effects of induced polarization. One possible cause for negative apparent resistivity is the subsurface geological structure. In this study, we provide some numerical examples showing that negative apparent resistivity can arise from geological structures. In numerical examples, we simulate field data using a 3D numerical modelling algorithm, and then extract 2D sections. Our numerical experiments demonstrate that the negative apparent resistivity can be caused by geological structures modelled by U-shaped and crescent-shaped conductive models. Negative apparent resistivity usually occurs when potentials increase with distance from the current electrodes. By plotting the voltage-electrode position curves, we could confirm that when the voltage curves intersect each other, negative apparent resistivity appears. These numerical examples suggest that when we observe negative apparent resistivity in field surveys, we should consider the possibility that the negative apparent resistivity has been caused by geological structure.

The Microleakage in Class V Cavity Based on Different Kinds of Several Dentin Adhesive and Composite Resin (5급 와동에서 수종의 상아질 접착제와 복합레진의 종류에 따른 미세누출)

  • Choi, Yoo-Seok;Jeong, Soon-Jeong;Jeong, Moon-Jin;Ahn, Yong-Soon;Park, Seon-Nyeo;Lim, Do-Seon
    • Journal of dental hygiene science
    • /
    • v.13 no.3
    • /
    • pp.330-338
    • /
    • 2013
  • In order to explore microleakage in class V cavity based on different kinds of several dentin adhesive and composite resin, 2 kinds of composite resin was restored and exposed after applying 4 kinds of dentin adhesives. Deposited in methylene blue solution for 4 hours and cut in parallel with tooth longitudinal axis. By observing dye penetration level of enamel and dentin margins of each restored resin following conclusion was obtained. 1. In composite resin Filtek Z350XT Universal (3M/ESPE Dental Products, USA) in enamel margin, Easy Bond (3M/ESPE Dental Products) showed the lowest microleakage and this leakage was represented to be high in the order of Single Bond 2 (3M/ESPE Dental Products), Scotchbond Multi-Purpose (3M/ESPE Dental Products) and Cearfil SE Bond (Kuraray Medical Inc., Japan). In case of Filtek Z350XT Flowable (3M/ESPE Dental Products), Scotchbond Multi-Purpose showed the lowest microleakage and this leakage was represented to be high in the order of Single Bond 2, Clearfil SE Bond and Easy Bond. 2. In case of Filtek Z350XT Universal in dentin margin, Easy Bond showed the lowest microleakage and this leakage was represented to be high in the order of Scotchbond Multi-Purpose, Single Bond 2 and Clearfil SE Bond. In case of Filtek Z350XT Flowable, Scotchbond Multi-Purpose and Single Bond showed the lowest microleakage and this leakage was represented to be high in the order of Clearfil SE Bond and Easy Bond. 3. In all the groups excepting S-U group (Single Bond 2+Filtek Z350XT Universal), enamel margin showed more higher microleakage than that of dentin margin. 4. There was a difference between enamel and dentin margin among each group but it was not significant statistically (p>0.05). When summarizing this result, it is considered that composite resin and dentin adhesive could be applied selectively and particularly in case of applying 1-step self-etching dentin adhesive, this method would be advantageous for manipulation convenience and shortening of operation time.

Oxygen and Hydrogen Isotope Studies of Fluid-Rock Interaction of the Radons-Sancheong Anorthositic Rocks (하동-산청 회장암질암의 유체-암석 상호반응에 대한 산소와 수소 동위원소 연구)

  • Park Young-Rok;Ko Bokyun;Lee Kwang-Sik
    • The Journal of the Petrological Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.224-237
    • /
    • 2004
  • The anorthositic rocks of the study area are divided into the northern Sancheong and southern Hadong anorthositic rocks depending on the different distribution patterns and lithologies. In order to evaluate the characteristics of the hydrothermal systems developed in the study area, oxygen and hydrogen isotopic compositions of the anorthositic rocks were measured. Oxygen isotopic values of the plagioclase exhibit an interesting spatial distribution. Plagioclase collected from the Sancheong anorthositic rocks in the northern part tends to have a relatively restricted range of $\delta$$^{18/0}$ values between 7.3 and 8.8$\textperthousand$, which are heavier than 'normal' $\delta$$^{18/O}$ value (6-6.5$\textperthousand$) typical for plagioclase of the fresh mantle-derived anorthosite, whereas plagioclase from the southern part is characterized by a wide range of $\delta$$^{18/O}$ values between -4.4 and 8.2$\textperthousand$ and much lighter values than 'normal' value for plagioclase of the fresh mantle-derived anorthosite. Plagioclase from the middle part has $\delta$$^{18/O}$ values heavier than the plagioclase from the southern part, but lighter than that from the northern part. The spatial distribution of $\delta$$^{18/O}$ values suggests that the decoupled hydrothermal flow systems might have been developed in the study area. Meteoric water dominated in the hydrothermal flow systems developed in the southern area, whereas magmatic fluid dominated in the northern area. The relationship between water content and hydrogen isotopic composition of anorthosites shows a positive correlation. The positive correlation indicates that fluids exsolved from magma during magmatic differentiation caused deuteric alteration of anorthositic rocks involving replacement of pyroxenes to amphiboles. After the deuteric alteration, hydrothermal system developed by meteoric water dominated the southern area, and erased record of the hydrothermal system developed by magmatic fluid at earlier stage. However, the development of meteoric hydrothermal system has been limited in the southern area only, and could not affect the Sancheong anorthositic rocks in the northern area. The abundant occurrences of secondary alteration minerals such as sericite, calcite, and chlorite in the southern Hadong anorthosite relative to the northern Sancheong anorthositc seem to be related to the overlapping of two distinct hydrothermal systems in the southern area.

Epidemiology of central venous catheter related blood stream infections in pediatric patients (중심정맥 도관 관련 감염의 역학 고찰)

  • Kim, Jung Hyun;Eun, Ho Sun;Choi, Kyung Min;Kim, Dong Soo;Young, Dong Eun
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.2
    • /
    • pp.157-161
    • /
    • 2006
  • Purpose : The purpose of this study is to investigate the pathogens of central venous catheter-related blood stream infections and search for the association among the insertion site, the duration and the underlying conditions with the prevalence of central venous catheter-related blood stream infections under 15 years old. Methods : A retrospective study was performed from Jan, 2003 to Dec, 2003 in Severance Hospital on 112 patients who undertook central venous catheter insertions. Results : We examined 112 patients who undertook central venous catheter insertion. The mean age of patients was $4.77{\pm}4.12$ years old. Coagulase negative Staphylococci was the most common organism of central venous catheter-related blood stream infections accounting for 33.9 percent, followed by Eenterococcus faecium(9.3 percent), and Staphylococcus aureus(7.5 percent), The most common insertion site was the right femoral vein, followed by the right jugular vein and the left femoral vein. The mean insertion period was $14.17{\pm}12.00$ days. Conclusion : Central venous catheter-related blood stream infections were not only related to the underlying conditions, but also to the insertion site. We need to study the clinical importance of coagulase negative Staphylococci as it is part of the normal flora of the skin. In future, more studies are needed to take preventive measures and improve treatment methods.

A Survey on the Understanding of Breast-feeding in Pregnant Woman (임신시 모유수유에 대한 인식조사)

  • Seo, Jeong Wan;Kim, Yong Joo;Lee, Kee Hyoung;Kim, Jae Young;Sim, Jay G;Kim, Hae Soon;Ko, Jae Sung;Bae, Sun Hwan;Park, Hye Sook;Park, Beom Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.5
    • /
    • pp.575-587
    • /
    • 2002
  • Objective : To investigate the understanding of breast-feeding in pregnant woman and the proper way of encouraging breast-feeding. Methods : Each questionnaire included items about demographic characteristics and the understanding of breast-feeding. The questionnaires were filled up by pregnant women visiting obstetric clinics in Seoul and its vicinities, Busan, Choongjoo and Chungjoo from July 2001 to August 2001. One thousand, two hundred ninety questionnaires were analysed by Chi square tests and multiple logistic regressions. Results : The majority of pregnant women(87.4%) planned breast-feeding. Forty three percent of them had plans to breast-feed for 4-6 months. There were no differences in the level of education, the family size and the source of information about breast-feeding in planning to breast-feed (P>0.05). The main reasons for not choosing to breast-feed were returns to work(41.3%), previous failures of breast-feeding(17.4%), concerns about insufficient amount of breast milk(10.9%), breast and nipple problems(10.3%) and maternal illness(9.4%). The average score on the test of the understanding about breast-feeding was 59.7/100. The average scores on the understanding about the methods and advantages of breast-feeding were 45.3/100 and 86.1/100, respectively. The maternal status of employment, previous history of breast-feeding, the time of decision to breastfeed, person advocating breast-feeding and the understanding on the advantages of breast-feeding were significant determinant factors in planning to breast-feed(P<0.05). Conclusion : Pediatricians should take steps to make an effort to increase the breast-feeding rate and to encourage breast-feeding by timely education. Beyond the medical field, political and social supports for breast-feeding are urgently needed.

Birth weight for gestational age patterns by sex, plurality, and parity in Korean population (한국의 성별, 태아수별, 출산수별 임신주수에 따른 출생체중)

  • Lee, Jung Ju
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.8
    • /
    • pp.732-739
    • /
    • 2007
  • Purpose : A universal standard of the birth weight for gestational age cannot be made since birth weight distribution varies with races, nations and eras. This report aims to establish the birth weight for gestational age patterns by sex, plurality, and parity, specific for Korean live births. Methods : The national birth certificate data of all live births in Korea from January 2000 to December 2004 were used: for live births with gestational age 24 weeks to 42 weeks (n=2,585,5160), mean birth weight, standard deviation and 10th, 25th, 75th and 90th percentile values were obtained for each gestational age group by one week increment. To establish final standard values of Korean birth weight distribution by gestational age, the finite mixture model to eliminated erroneous birth weights was used for respective gestational age. Same as above method the birth weight for gestational age standard by sex, plurality, and parity were completed. Results : The male newborns are more heavier than female during the entire gestational age. The singletons are more heavier than twin during the entire gestational age. The para 2 are more heavier than the para 1 during the entire gestational age. Korean standard was more heavier in 10th and 50th percentile than Lubchenco's standard. Alexander's standard was more heavier in 50th and 90th percentile than Korean standard. Conclusion : These birth weight for gestational age patterns by sex, plurality, and parity are similar to the other standards. I hope that for Korean infants, this curve will help clinicians in defining and managing the large for gestational age infants and also for infants with intrauterine growth retardation.

The influence of implant diameter, length and design changes on implant stability quotient (ISQ) value in artificial bone (임플란트의 직경, 길이 및 디자인변화가 임플란트 안정성지수(ISQ)에 미치는 영향)

  • Lee, Jeong-Yol;Lee, Won-Chang;Kim, Min-Soo;Kim, Jong-Eun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.292-298
    • /
    • 2012
  • Purpose: The purpose of this study is to ascertain the stability of the implant by comparing the effects of the change of implant diameter, length and design on implant stability quotient. Materials and methods: To remove the variable due to the difference of bone quality, the uniform density (0.48 g/$cm^3$) Polyuretane foam blocks (Sawbones$^{(R)}$, Pacific Research Laboratories Inc, Vashon, Washington) were used. Implants (Implantium$^{(R)}$, Dentium, Seoul, Korea) were placed with varying diameters (${\phi}3.8$, ${\phi}4.3$ and ${\phi}4.8$) and length (8 mm, 10 mm and 12 mm), to assess the effect on implant stability index (ISQ). Also the influence of the design of the submerged and the non-submerged (SimplelineII$^{(R)}$, Dentium, Seoul, Korea) on ISQ was evaluated. To exclude the influence of insertion torque, a total of 60 implants (n = 10) were placed with same torque to 35 N. Using Osstell$^{TM}$ mentor (Integration Diagnostic AB, Sweden) ISQ values were recorded after measuring the resonant frequency, one-way ANOVA and Tukey HSD test results were analyzed. (${\alpha}$=0.05). Results: 1. The change of the diameter of the implant did not affect the ISQ (P>.05), but the increase of implant length increased the ISQ(P<.001). 2. The change in implant design were correlated with the ISQ, and the ISQ of submerged design was significantly higher than that of the non-submerged design(P<.05). Conclusion: In order to increase implant stability, the longer implant is better to be selected, and on the same length of implant, submerged design is thought to be able to get a higher ISQ than the non-submerged.