• Title/Summary/Keyword: 색수차

Search Result 54, Processing Time 0.028 seconds

Relationship between Reading Speed and Blinking Rate according to Longitudinal Chromatic Aberration during Book Reading (종이책 독서 시 종색수차에 따른 읽기속도와 순목횟수의 상관관계)

  • Kim, Se-il;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.369-375
    • /
    • 2015
  • Purpose: The current study was performed to estimate the changes in reading speed and blinking rate according to different background colors when reading paper book and further investigate their correlation. Methods: Twenty-nine adults (10 males, 19 females) who consented to the present study and had no ocular disease, ocular surgery history showing normal binocular vision were participated into the study. The subjects were asked to read the novels with black letter printed on white, red, green and blue background for 15 min, respectively. Then, the reading speed per page and blinking rate per page were measured during reading and analyzed according to background colors. Results: Reading speed per page according to the background color showed a tendency to accelerate in the white and green background as the reading time increased however, it was almost unchanged in the blue background and rather decelerated in the red background. On the other hand, the blinking rate per page tended to decrease in all background as the reading time was increased however, the smallest reduction was shown in the red background. There was a correlation that the reading speed increased as the blinking rate decreased in all backgrounds and the best correlation was shown in the green background. Conclusions: From the results, a correlation between the increasing reading speed and the reducing blinking rate while reading paper book with same demand on accommodation and convergence was confirmed however, the change in blinking rate and reading speed was varied depending on the main wavelength of light. It might mean that the working speed and visual fatigue can be varied depending on the difference of main wavelength when doing near work. Thus, it can be suggested that the adjustment of working environment and conditions should be made according to the kind of required perception.

Limitations of time resolution and spatial overlap caused by group velocity mismatch in experiments using ultrashort UV and visible optical pulses. (자외선과 가시광선 극초단 펄스 실험의 군속도 차이에 의한 시간 분해능 및 공간 겹침의 제한)

  • 김성규
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.252-259
    • /
    • 1994
  • The method of calculating overlap dispersion caused by group velocity mismatch between uv and visible pulses in ultrafast pump-probe experiments is presented to discuss limitations of the time resolution and signal intensity. The calculations show arrangements using a single focusing lens shall result in undesirable time resolution and low signal intensity. Achromatic doublets result in unrealistic solutions. However, dramatic improvement in the time resolution and signal intensity is expected in the optical arrangements using separate lens for each pulse and in the arrangements using a cutoff secondary lens with a main lens. lens.

  • PDF

Development of Focused Ion Beam Column Using Ga Source (갈륨 소스를 이용한 집속이온빔 컬럼 개발)

  • Gim, Tzang-Jo;Lee, Jae-Seung;Choi, Yoon;Choi, Eun-Ha;Park, Chul-Woo;Kim, Jong-Kuk;Kim, Young-Gweon;Um, Chang-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.3
    • /
    • pp.185-189
    • /
    • 2009
  • Focused ion beam system was designed, which includes LMIS, electrostatic lens and high voltage power supply. Control program is updated for high speed image processing. The details of vibration-free vacuum system and other important electrical parts were trouble-shooted for appropriately controlling high acceleration voltages.

Design of Imaging Optical System with 24mm Focal length for MWIR (MWIR용 24mm 초점거리를 가지는 결상광학계의 설계)

  • Lee, Sang-Kil;Lee, Dong-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.6
    • /
    • pp.203-207
    • /
    • 2018
  • This paper deals with the design and development of a lens system capable of imaging an infrared image of $3{\sim}5{\mu}m$ wavelength bands with a focal length of 24mm and good atmospheric transmission characteristics. The design used CodeV, a commercial design program, and the optimization is carried out with weighting to eliminate chromatic aberration, spherical aberration and distortion. The designed lens system consists of two lenses consisting of Si and Ge. Each lens has an aspherical surface on one side. And this optical system has the resolution of the characteristics that the MTF value is 0.40 at the line width of 29lp/mm and the MTF value is 0.25 at the line width of 20lp/mm. This optical system is considered to have the capability to be applied to the thermal imaging camera for MWIR using the $206{\times}156$ array infrared detector of $25{\mu}m$ pixels and the $320{\times}240$ array infrared detector of $17{\mu}m$ pixels.

Lens system design for head mounted display using schematic eyes (정밀모형안을 이용한 Head Mounted Display용 렌즈계 설계)

  • 박성찬;안현경
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.236-243
    • /
    • 2003
  • We discussed the design of lens module schematic eyes equivalent to finite model eyes, which are used to model the human eye based on spherical aberration and Stiles-Crowford effect. The optical system for head mounted display (HMD) is designed and evaluated using lens module schematic eyes. In addition to a compact HMD system, an optical system with high Performance is required. To satisfy these requirements, we used diffractive optical elements and aspheric surfaces so that the color and mono-chromatic aberrations were corrected. The optical system for HMD is composed of 0.47 inch micro-display of SVGA grade with 480,000 pixels, a plastic hybrid lens for the virtual image, and the lens module schematic eyes. The designed optical system fulfills the current specifications of HMD: such as, EFL of 31.25 mm, FOV of 24H$\times$18V$\times$30D degrees, and overall length of 59.1 mm. As a result, we could design an optical system useful for HMD; the system is expected to be comfortable while the user wears it.

Optical Design of a Lister Objective Stable Against Chromatic Variation for 405-nm Wavelength (파장 405 nm에서 파장변화에 안정화된 Lister 대물렌즈 설계)

  • Kim, Jin-Hyung;Lee, Jong-Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.6
    • /
    • pp.295-303
    • /
    • 2020
  • A Lister objective of NA 0.25 and 10×, stabilized against chromatic variation for a wavelength of 405 nm is designed. We develop a new solution for stabilizing a cemented doublet that has specified axial thicknesses. Using the new method, we can easily obtain a useful design for some practical purpose. At the initial design stage, two cemented doublets corrected independently are used. The stabilizing conditions for the whole system are maintained during optimization. The final design of the Lister objective shows that the chromatic variation of EFL, BFL, and RMS wavefront errors are very small at the 405-nm wavelength, as expected.

Hygienic Quality of Drinking Water Served in Restaurants and Quality Characteristics of Drinking Water Boiled with Various Plant Materials (외식업소 음용수의 위생실태와 침출재료에 따른 기호성과 저장성)

  • Ahan, Yu-Bok;Jeong, Eun-Ju;Lee, Shin-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.3
    • /
    • pp.159-164
    • /
    • 2007
  • The viable cell of 60% drinking water among 25 drinking water served in restaurant of Daegu district showed above 100 CFU/mL which is sanitary standard of drinking water. The 50 CEO of restaurant considered drinking water served in their own restaurant as just safe and were very deficient in aware of sanitation about drinking water. Sensory quality of drinking water boiled with plant materials, such as barley, Cassia semen, corn, Buckwheat, Korean solomon's seal, Chamomile, Brown rice-green and peppermint was improved in color, taste, flavor and overall acceptability compare to marketed drinking water, respectively. Especially drinking water boiled with Korean solomon's seal was the best In overall acceptability. The number of total bacteria reached above $10^2 CFU/mL$ in marketed drinking water after 4 days storage at 10. But the growth of microorganism did not occur in boiled drinking water with Brown rice-green tea, Korean solomon's seal, barley, Cassia semen and com during storage for 10 days at $10^{\circ}C$, respectively. The number of total bacteria reached above $10^2 CFU/mL$ in marketed drinking water after storage for 1 days at $25^{\circ}C$. The growth of microorganism was accelerated in boiled drinking water with corn, Korean solomon's seal, barley, Cassia semen except Brown rice-green tea during storage far 10 days at $25^{\circ}C$, respectively.

Change of Contrast Sensitivity Induced by Tinted Spectacle Lens (칼라필터 렌즈에 따른 대비감도의 변화)

  • Seo, Jae-Myoung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.47-51
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the change of contrast sensitivity by prescribing tinted lenses and to provide the clinical manual. Methods: Contrast sensitivity was measured for twenty adults with normal vision while they wore yellow, orange and green tinted lenses. To measure contrast sensitivity, the 5 spatial frequencies (2, 4, 6, 8 and 10 cpd) were used for 33 ms and 233 ms, respectively. Results: The contrast sensitivity was overall higher with 233 ms than 33 ms (p<0.05). The peaks of contrast sensitivity with 33 ms and 233 ms were 1.75 log unit with the yellow lens and 1. 85 log unit without the color respectively. However, there was no significance between the yellow and orange tinted lens (p>0.64) Conclusions: Yellowish tinted lens that reduces chromatic aberration and the scattering is prescribed for the various purposes to improve visual functions. Before prescribing tinted lens, identifying characteristic of user and tinted lens for cut off wavelengths is recommended.

Development of an Optical System for Iris Photographing (홍채 촬영용 광학계 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.177-183
    • /
    • 2003
  • We tried to design and manufacture an iris photographing optical-system which is used in the Oriental medicine or medical diagnostics. The whole system consists of a light source part, an image focusing part, a CCD transfer part and a diagnosis S/W. We designed the image focusing part to the reduction optical-system with 0.58X magnification of which the chromatic aberration is removed by using materials of FD60 and BACD5. The image focusing part's localization did big contribution in coot reduction of products. The manufactured iris photographing optical-system had superior performance in aspect that has stereoscopic effects of images in comparison with the foreigner's.

  • PDF

서프레서를 적용한 집속이온빔 장치 액체금속이온원의 각분포 특성연구

  • Min, Bu-Gi;O, Hyeon-Ju;Gang, Seung-Eon;Choe, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.545-545
    • /
    • 2012
  • 집속이온빔장치(FIB: Focused Ion Beam System)에 사용하는 액체금속이온원(LMIS: Liquid Metal Ion Source)은 고 전류밀도, 고 휘도, 낮은 에너지퍼짐 등 많은 장점이 있다. 집속이온빔장치는 주로 표면 분석, 집적 회로의 수정, 마스크 교정(Repair) 및 잘못된 부분의 분석(Failure Analysis) 등에 사용되고 있는데 최근에는 고 분해능의 이온빔 리소그래피와 이온 주입의 기술 및 미세가공 기술 등의 분야에 집중되고 있으며 이를 위해서는 집속이온빔장치의 수렴성(Convergence)을 개선해 나가는 것이 중요하다. 집속이온빔장치의 수렴성은 이온빔의 에너지 퍼짐(Energy Spread)과 각 분포(Angular Distribution)에 많은 영향을 받으며 에너지퍼짐 특성은 색수차에 직접적인 영향을 준다. 수렴성을 개선하기 위해 기존의 에미터(Emitter), 저장소(Reservoir), 추출극(Extractor)으로 제작된 액체금속이온원에 서프레서(Suppressor)라는 새로운 전극을 사용하여 이 전극의 유 무에 따른 각 분포의 변화에 대해 연구하였다.

  • PDF