• Title/Summary/Keyword: 상호연관성 시험

Search Result 55, Processing Time 0.02 seconds

Comparison of EEC-4 Plate Test and Charm II Test in Residual drug Screening Methods on Meats (식육 중 잔류물질 스크리닝법인 EEC-4 Plate Test와 Charm II Test 비교)

  • Ham Hee-jin;Kim Doo-whan;Kweon Taek-boo;Lee Jung-hark
    • Journal of Food Hygiene and Safety
    • /
    • v.19 no.4
    • /
    • pp.198-202
    • /
    • 2004
  • It was carried out to compare the relationship of EEC 4-plate test method and Charm II test method by HPLC. 46 only tetracyclines, 4 only sulfonamides, 4 sulfonamides+tetracyclines, one amphenicols+tetracyclines, and one amphenicols+sulfonarnides+tetracyclines, it was detected on 71 porks of EEC 4-plate positive or Charm II positive by HPLC. In case of sulfonamides and chloramphenicols, two test methods had related with each other, but had no relation in tetracyclines. Also, it was $10.5\%(6/57)$ tetracyclines, $81.8\%(9/11)$ chloramphenicols that were EEC 4 plate positive or Charm II positive, but not detectrd by HPLC. Consequently, EEC 4-plate test method and Charm II test method were suitable by screening test on antibiotics and sulfonamides etc.

Self-Diagnosis Property of Fracture in Carbon Fiber Composite Mortar (탄소섬유 분말 혼입 모르타르 복합 구조체의 파괴예측 자가진단 특성)

  • Park, Seok-Kyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.1
    • /
    • pp.113-120
    • /
    • 2007
  • A new material was tested and its applicability was investigated so as to give the capability of self-diagnosis of fracture in composite mortar. In the research for giving self-diagnosis capability, conductive mortar intermixed with cokes and carbon fiber powder(milled carbon fiber) was developed and its using for self-diagnosis material was proposed. Then after examining change in the value of electric resistance and AE characteristics before and after the occurrence of cracks at each weight-stage, the relationships of each factors were analyzed. As the results, it can be recognized that a new composite material with cokes and carbon fiber powder(milled carbon fiber) can be applied for self-diagnosis of fracture in mortar specimen.

Self-Diagnosis Properties of Fracture in Reinforced Concrete Intermixed with Conductive Materials (전도성 재료 혼입 철근콘크리트 구조체의 파괴예측 자기진단 특성)

  • Park, Seok-Kyun;Cho, Sung-Dong
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.369-374
    • /
    • 2008
  • Two types of conductive materials are selected and their applicable properties are investigated so as to give the capability of self-diagnosis of fracture in composite mortar, concrete and reinforced concrete. In this study, for giving selfdiagnosis capability, the powder of cokes and milled carbon fiber as conductive materials are selected and intermixed with mortar, concrete and reinforced concrete. After examining change in the value of electric resistance before and after the occurrence of cracks at each flexural load-stage in composite mortar, concrete or reinforced concrete, the relationships of each factors (electric resistance, crack and flexural load) are analyzed. As the results, it can be recognized that conductive materials with powder of cokes and milled carbon fiber can be applied for self-diagnosis of flexural fracture in composite mortar, concrete and reinforced concrete specimen.

Development of Thermal-Hydro Pipe Element for Ground Heat Exchange System (지중 열교환 시스템을 위한 열-수리 파이프 요소의 개발)

  • Shin, Ho-Sung;Lee, Seung-Rae
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.8
    • /
    • pp.65-73
    • /
    • 2013
  • Ground-coupled heat pump system has attracted attention as a promising renewable energy technology due to its improving energy efficiency and eco-friendly mechanism for space cooling and heating. Pipes buried in the ground play a role of direct thermal interaction between circulating fluid inside the pipe and surrounding soils in the geothermal exchange system. However, both complexities of turbulent flow coupling thermal-hydraulic phenomena and very long aspect ratio of the pipe make it difficult to model the heat exchange system directly. Energy balance for fluid flow inside the pipe was derived to model thermal-hydraulic phenomena, and one-dimensional pipe element was proposed through Galerkin formation and time integration of the equation. Developed element is combined to pre-developed FEM code for THM phenomena in porous media. Numerical results of Thermal Response Test showed that line-source model overestimates equivalent thermal conductivity of surrounding soils due to thermal interaction between adjacent pipes and finite length of the pipe. Thus, inverse analysis for the TRT simulation was conducted to present optimal transformation matrix with utmost convergence.

Assessment of Ultrasonic Pulse Velocity Method for Early Detection of Frost Damage in Concrete (콘크리트의 초기동해 진단을 위한 초음파 속도법의 적용 가능성 평가)

  • Moon, Sohee;Lee, Taegyu;Choi, Heesup;Choi, Hyeonggil
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.2
    • /
    • pp.193-202
    • /
    • 2024
  • This research delves into the evaluation of the suitability of ultrasonic pulse velocity as a diagnostic tool for early detection of frost damage in concrete. The investigation involves the measurement of compressive strength and ultrasonic pulse velocity concerning the depth of freezing for individual mortar specimens, followed by an analysis of their microstructure and their interrelation. The findings indicate a consistent decrease in both compressive strength and ultrasonic pulse velocity with increasing freezing depth. Furthermore, a correlation between compressive strength and ultrasonic pulse velocity concerning the depth of early frost damage is established. Consequently, the study asserts the potential of utilizing the ultrasonic pulse velocity method for early detection of frost damage in concrete, with prospects for quantifying the depth of damage through further research endeavors.

AN EMPIRICAL STUDY ON DREAM, DAYDREAM AND HOPE IN CHILDREN(1):FROM DEVELOPMENTAL PERSPECTIVE (어린이의 꿈, 공상 및 희망에 대한 경험적 연구(1) : 발달학적 관점에서 고찰)

  • Kim, Soo-Jeong;Shin, Min-Sup;Nam, Min;Hong, Kang-E
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.8 no.1
    • /
    • pp.3-21
    • /
    • 1997
  • We examined the developmental characteristics of dream, daydream, and hope of elementary school students in their 1st, 3rd, and 5th grades, and studied the correlation between three variables. We summarized the results of this study as follows. 1) The contents of dream developed with the cognitive development and socialization process. In detail, appearance of animals, family members, and known persons gradually decreased, and appearance of self, same-sex peers, and strangers gradually increased. These results are comparable with the previous studies of dream. 2) Daydream, hope, and current state also developed with age. In detail, frequency of daydream increased, and the contents of daydream and hope changed toward more self-centered and more realistic. The changes of current state are thought to reflect the specific situation of Korea. 3) There are some correlation among dream, daydream, and hope. Especially happy mood and fearful mood had positive correlation with the relevant contents of dream, daydream, and hope. Also the contents of dream showed positive correlation with the same contents of daydream. This study is the first trial which investigate the developmental characteristics of dream, daydream, and hope of normal children in Korea. We verified that dream and daydream are on the continuous line of ‘reality-imitation-play-daydream-dream’ Finally, considering the facts that dream developed with age;responded to meaningful emotional experiences;and had the correlation with daydream, hope, and current state, the results of this study support the psychological meaning of dream.

  • PDF

Effects of Systematic Variation Application of Fe, Mn, Cu, and Zn on These Relative Contents, Uptake Amounts, and Mutual Ratios in Orchardgrass and White Clover (Fe, Mn, Cu, Zn의 Systematic Variation 시비가 Orchardgrass 및 White Clover중 이들의 상대 함량, 탈취량 및 상호비율에 미치는 영향)

  • Jung, Yeun-Kyu
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.24 no.4
    • /
    • pp.281-292
    • /
    • 2004
  • This pot experiment was conducted to investigate the effects of systematic variation appling of Fe, Mn, Cu, and Zn on forage performance of orchardgrass and white clover, The treatments of systematic variation were 0/100. 25/75, 50/50. 75/25, and $100/0\%$ in the Fe/Cu, Mn/Zn, and Fe+Cu/Mn+Zn trials, respectively. The treatments of Fe/Mn/Cu/Zn trial were $70\%$ in main-element and $10\%$ in other 3sub-elements. 1 . General differences had been showed in the relative contents, uptake amounts, and mutual ratios of Fe, Mn, Cu, and Zn between orchardgrass and white clover. The effects of Fe application on the all traits were generally insignificant. The Mn and Cu applications, however, showed consistent differences in the all traits. At the high relative content of Mn in the forages influenced by the Mn application, the relative contents of Fe, Cu and Zn were greatly decreased without the significant differences in common content. 2. The increase of uptake amount of each micronutrient was not positively correspond to the yield increase. In some cases, the uptake amount of micronutrient was greatly increased without the significant increase of yield. At the Mn application, the Mn uptake amount was relatively much more increased than increase of the yield. The uptake amount of each element was significantly increased by the application with Mn and Cu. However, it was not in the case of Fe and Zn. 3. The mutual ratios of micronutrients were more influenced by the applications of Mn and Cu, especially Mn, than those by the applications of Fe and Zn. In the Fe/cu trial, the ratios of Fe/Cu showed 6.0~ 10.5 in orchardgrass and 10.2~ $16.4\%$ level of difference in white clover. In the Fe+Cu/Mn+Zn trial, the ratios of Mn/Cu, Mn/Zn, and Fe/Mn were greatly influenced by the treatments. It has been also found that the poor growth of white clover was caused by the unbalanced ratios of Fe/Mn, and it tended to be enhanced by the good applications and mutual ratios of other elements.

Malfunction Measures and Susceptibility test of Elevator Based on EMS(Electromagnetic Susceptibility) Standard (EMS 규정에 따른 승강기 내성시험 및 오동작 대책에 관한 연구)

  • Kim, Gi-Hyun;Bae, Suk-Myong;Lee, Joo-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.78-85
    • /
    • 2007
  • The malfunction accidents such as kept within elevator, sudden rise, sudden stop, error of level indication which can bring about uneasiness of elevator passenger and be related with life accident are occurring. However, as there is not field recurrence for this portion and they are accidents that occur and then disappear, it is actually difficult to confirm the reason of accident. Therefore, we made an experiment for tolerance in three models which is being built recently according to EN12016(2004) standard and analyzed the movement characteristics of elevator to study the reason which can bring about confine and malfunction. Furthermore after supplementing measures for malfunction, Finally this paper will be used as reference to suggest methods for malfunction of elevator facility and the analysis for mutual relation between Power Quality and malfunction and fault of elevator.

Fundamentals of Ecotoxicity Evaluation Methods Using Domestic Aquatic Organisms in Korea: (KII) Green Algae (국내 생물종을 이용한 생태독성평가 기반연구: (III) 녹조류)

  • An, Youn-Joo;Nam, Sun-Hwa;Baek, Yong-Wook
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.2
    • /
    • pp.117-127
    • /
    • 2008
  • Green algae are important primary producers in aquatic ecosystem, and they are sensitive test species in bioassay. Green algae are broadly used to assess the adverse effects of various chemicals by measuring the inhibition of metabolism, reproduction and survival. In this study, we extensively gathered domestic and foreign toxicity test methods conducted using green algae, which are distributed in Korean water environment. Selected eight domestic green algae were Chlamydomonas reinhardtii, Desmodesmus subspicatus (=Scenedesmus subspicatus), Scenedesmus abundans, Scenedesmus acutus, Scenedesmus quadricauda, Podohedriella falcata (=Ankistrodesmus falcatus), Pseudokirchneriella subcapitata (=Selenastrum capricornutum), and Chlorella vulgaris. Forty four test methods were collected from the standard test ones, government reports, SCI papers and Korean research papers. P. subcapitata and D. subspicatus are the most common test species recommended by the standard test methods. Initial cell density and dilution water were the main differences among the test methods we collected. We proposed the suitable ecotoxicity test methods based on domestic green algae in Korea. This study could be a fundamental basis to establish the ecotoxicity test methods by green algae distributed in Korea.

The Cause Analysis and Research of Malfunction for Elevator Equipment of the Apartment House (공동주택의 승강기 설비에 대한 오동작 원인 조사 및 고찰)

  • Kim, Gi-Hyun;Bang, Sun-Bae;Kim, Chong-Min;Bae, Suk-Myong;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.65-71
    • /
    • 2006
  • The number of elevator installation increases every year about 15,000. The number of confine-disease of elevator increases every year and then sudden in, sudden stop, error of level indication, stand; those can bring to uneasiness of elevator passenger and malfunction related life accident is increasing. Therefore we researched elevator repair diary of elevator repairing company, APT management office and 119 life rescue for elevator confine-disease during 2004. 1. 1.${\sim}$12. 31. we analyzed the content and the time type and cause of the malfunction and fault for APT elevator. Form the result of 119 life rescue, only power reset is 24[%] and only power failure is 8.2[%] by cause of confine-disease. This paper will be used data of the analysis for mutual relation between Power Quality and malfunction and fault of elevator.